<?xml version='1.0' encoding='utf-8'?>
<section number="19-122.01" name="Noise level and noise disturbance standards for construction" law="code" slug="sec-19-122.01" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_19PO_DIV2NOCO_S19-122.01NOLENODISTCO">
  <level label="a">
    <text>Maximum allowable noise levels for construction.</text>
    <level label="1">
      <text>A person must not cause or permit noise levels from construction activity that exceed the following levels:</text>
      <level label="A">
        <text>From 7 a.m. to 6 p.m.:</text>
        <level label="i">
          <text>75 dBA if the Department has not approved a noise-suppression plan for the activity; or</text>
        </level>
        <level label="ii">
          <text>85 dBA if the Department has approved a noise-suppression plan for the activity.</text>
        </level>
      </level>
      <level label="B">
        <text>The level specified in Section 19-122(a) at all other times.</text>
      </level>
    </level>
    <level label="2">
      <text>Construction noise levels must be measured at the location, at least 50 feet from the source, on a receiving property where noise from the source is greatest.</text>
    </level>
    <level label="3">
      <text>The Department must establish requirements for noise-suppression plans and adopt procedures for evaluating and approving plans. The requirements must provide that, at least 10 days before approving a noise-suppression plan, the Director must provide public notice reasonably calculated to reach at least a majority of households that might be affected by the construction activity noise levels above 75 dBA.</text>
    </level>
  </level>
  <level label="b">
    <text>Construction noise disturbance. The prohibition on noise disturbance in Section 19-122(b) applies to construction activities, notwithstanding subsection (a).</text>
  </level>