<?xml version='1.0' encoding='utf-8'?>
<section number="22-118" name="Information to be submitted for issuance of a septic permit" law="code" slug="sec-22-118" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_22TESEDISY_DIV3SEDISY_SD1PE_S22-118INBESUISSEPE">
  <level label="a">
    <text>Upon completion of satisfactory percolation tests, applicants for a permit under this Division shall furnish the following information:</text>
    <level label="1">
      <text>A completed Sewage Disposal Permit Application.</text>
    </level>
    <level label="2">
      <text>Six (6) copies of completed site plans of a scale of 1":10' - 1":50' which will include:</text>
      <level label="A">
        <text>Location of the proposed structure to be serviced by the disposal system.</text>
      </level>
      <level label="B">
        <text>A diagram including the house dimensions and number of floors of the proposed structure to be served by the disposal system.</text>
      </level>
      <level label="C">
        <text>Location of utilities entering and crossing the lot.</text>
      </level>
      <level label="D">
        <text>Original and final contours at one (1) or two (2) foot intervals, as may be appropriate, to show the topography and final grading of the lot. On a remodel of a system, the topography shall be furnished if requested by the Health Department.</text>
      </level>
      <level label="E">
        <text>Location of all satisfactory and unsatisfactory percolation tests and water table holes.</text>
      </level>
      <level label="F">
        <text>Location of wells on the property and wells within one hundred (100) feet of the property line.</text>
      </level>
      <level label="G">
        <text>Detailed plan of the proposed disposal system shall include:</text>
        <level label="i">
          <text>Size of septic tank;</text>
        </level>
        <level label="ii">
          <text>Dimensions of disposal trench, seepage pits or seepage bed;</text>
        </level>
        <level label="iii">
          <text>Location of trench to be shown on contour;</text>
        </level>
        <level label="iv">
          <text>Elevation profile of entire disposal system;</text>
        </level>
        <level label="v">
          <text>Location of all components of disposal system.</text>
        </level>
      </level>
      <level label="H">
        <text>Storm water management proposal.</text>
      </level>
    </level>
    <level label="3">
      <text>Any pertinent groundwater and geological data as the Health Officer may require.</text>
    </level>
    <level label="4">
      <text>Evidence to demonstrate to the satisfaction of the Health Officer that there is no part of a community sewerage system legally and economically available to the building to be served.</text>
    </level>
  </level>
  <level label="b">
    <text>A fee designated in the Table of Fees, section 2-253.63, Attachment A shall be charged for a plat review of a private septic system or well.</text>
  </level>
  <level label="c">
    <text>A fee designated in the Table of Fees, section 2-253.63, Attachment A shall be charged for each time plans are required to be resubmitted for additional review because of errors or missing information, and the fee is payable when the plan is resubmitted.</text>
  </level>
</section>
