(a)
Deep percolation tests - minimum drop as a function of hole diameter with four feet of water in the hole.*
DIAMETER INCHESDROP IN 30 MINUTESMINUTES PER INCH DROP
88.03.6
106.05.0
125.06.0
144.56.6
164.07.5
183.58.5
203.010.0
223.010.0
242.512.0
*Equivalent to State standard test. .2077 gallons/square foot in 30 minutes.
(b)
For test holes with more than four feet of water, the minimum drop shall be determined by the following formula:
Minimum Drop = 16H / D
H = Height of water column (feet)