<?xml version='1.0' encoding='utf-8'?>
<section number="22-154" name="Table 3" law="code" slug="sec-22-154" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_22TESEDISY_DIV3SEDISY_SD3NUIN_S22-154TA3">
  <level label="a">
    <text>Deep percolation tests - minimum drop as a function of hole diameter with four feet of water in the hole.*</text>
    <table>
      <row>
        <cell>DIAMETER INCHES</cell>
        <cell>DROP IN 30 MINUTES</cell>
        <cell>MINUTES PER INCH DROP</cell>
      </row>
      <row>
        <cell>8</cell>
        <cell>8.0</cell>
        <cell>3.6</cell>
      </row>
      <row>
        <cell>10</cell>
        <cell>6.0</cell>
        <cell>5.0</cell>
      </row>
      <row>
        <cell>12</cell>
        <cell>5.0</cell>
        <cell>6.0</cell>
      </row>
      <row>
        <cell>14</cell>
        <cell>4.5</cell>
        <cell>6.6</cell>
      </row>
      <row>
        <cell>16</cell>
        <cell>4.0</cell>
        <cell>7.5</cell>
      </row>
      <row>
        <cell>18</cell>
        <cell>3.5</cell>
        <cell>8.5</cell>
      </row>
      <row>
        <cell>20</cell>
        <cell>3.0</cell>
        <cell>10.0</cell>
      </row>
      <row>
        <cell>22</cell>
        <cell>3.0</cell>
        <cell>10.0</cell>
      </row>
      <row>
        <cell>24</cell>
        <cell>2.5</cell>
        <cell>12.0</cell>
      </row>
      <row>
        <cell>*Equivalent to State standard test. .2077 gallons/square foot in 30 minutes.</cell>
      </row>
    </table>
  </level>
  <level label="b">
    <text>For test holes with more than four feet of water, the minimum drop shall be determined by the following formula:</text>
    <table>
      <row>
        <cell>Minimum Drop = 16H / D</cell>
      </row>
      <row>
        <cell>H = Height of water column (feet)</cell>
      </row>
      <row>
        <cell>D = Diameter of hole (inches)</cell>
      </row>
    </table>
  </level>
</section>