<?xml version='1.0' encoding='utf-8'?>
<section number="32-208.04" name="Coastal and Wetland Floodplain Regulations — Accessory Structures" law="code" slug="sec-32-208.04" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_32WAREPRGRCO_DIV4FLOR_S32-208.04COWEFLREACST">
  <level label="a">
    <text>Accessory structures shall be limited to not more than three hundred (300) square feet in total floor area.</text>
  </level>
  <level label="b">
    <text>Accessory structures shall comply with the elevation requirements and other requirements of Section 32-208 of the County Code or, if not elevated, shall:</text>
    <level label="1">
      <text>Be useable only for parking of vehicles or limited storage;</text>
    </level>
    <level label="2">
      <text>Be constructed with flood damage-resistant materials below the base flood elevation;</text>
    </level>
    <level label="3">
      <text>Be constructed and placed to offer the minimum resistance to the flow of floodwaters;</text>
    </level>
    <level label="4">
      <text>Be anchored to prevent flotation;</text>
    </level>
    <level label="5">
      <text>Have electrical service and mechanical equipment elevated to or above the base flood elevation; and</text>
    </level>
    <level label="6">
      <text>If larger than one hundred (100) square feet in size, have walls that meet the requirements of Section 32-208, as applicable for the flood zone; and if located in Coastal A Zones, walls shall have flood openings that meet the requirements of Section 32-207.</text>
    </level>
  </level>
</section>