Section 1809.01 Aggregate Pier or similar Ground Improvement Foundation System is added.

(a) Construction tolerance of the pier installed location shall not be more than 6 inches.

(b) For the 3-pier footing, the centroid of the installed piers, the centroid of the footing and the centerlines of the supported column shall be coincided.