<?xml version='1.0' encoding='utf-8'?>
<section number="4-189.01" name="Soils and Foundations; Section 1809.01, Ground Improvement Foundation" law="code" slug="sec-4-189.01" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_4BU_DIV1BUCO_SD2AMINBUCO_S4-189.01SOFOSE1809.01GRIMFO">
  <text>Section 1809.01 Aggregate Pier or similar Ground Improvement Foundation System is added.</text>
  <level label="a">
    <text>Construction tolerance of the pier installed location shall not be more than 6 inches.</text>
  </level>
  <level label="b">
    <text>For the 3-pier footing, the centroid of the installed piers, the centroid of the footing and the centerlines of the supported column shall be coincided.</text>
  </level>
  <level label="c">
    <text>The capacity of the single-pier-, and 2-pier footings used in supporting column/wall loads shall be reduced due to the eccentricity (allowed construction tolerance) of the pier location.</text>
  </level>
</section>