  <section number="4-256" name="Building Envelope Requirements; C402.2.1.1, Roof Solar Reflective and Thermal Emittance" law="code" slug="sec-4-256" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_4BU_DIV1BUCO_SD5INENCOCO_S4-256BUENREC4ROSORETHEM">
    <text>Section C402.2.1.1. is amended to read as follows: Low sloped roofs, with a slope less than 2 units vertical in 12 horizontal, directly above cooled conditioned spaces in Climate Zones 1, 2, 3 and 4 shall comply with one or more options in Table C402.2.1.1.</text>
  </section>
  <section number="4-257" name="Building Envelope Requirements. Table C402.3. Fenestration" law="code" slug="sec-4-257" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_4BU_DIV1BUCO_SD5INENCOCO_S4-257BUENRETAC4FE">
    <text>Table C402.3 is amended to read as follows: SHGC is Climate Zone 4 is changed from .40 to .35.</text>
  </section>
  <section number="4-258" name="Electrical Power and Lighting Systems (Mandatory); C405.2.1 Occupant Sensor Controls" law="code" slug="sec-4-258" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_4BU_DIV1BUCO_SD5INENCOCO_S4-258ELPOLISYMAC4OCSECO">
    <text>Section C405.2.1 Occupant sensor controls shall be installed in all classrooms, conference/meeting rooms, employee lunch and break rooms, private offices, restrooms, storage rooms, janitorial closets, enclosed stairways, and other spaces 300 square feet (28m2) or less enclosed by floor-to-ceiling height partitions. These automatically turn off lights within 30 minutes of all occupants leaving the space, and shall turn the lighting on to not more than 50 percent power.</text>
  </section>
  <section number="4-259" name="Electrical Power and Lighting Systems (Mandatory); C405.2.4. Specific Application Controls" law="code" slug="sec-4-259" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_4BU_DIV1BUCO_SD5INENCOCO_S4-259ELPOLISYMAC4SPAPCO">
    <text>Section C405.2.4 7. Lighting for parking areas shall have automatic controls so that after 15 minutes of non-activity, lighting power density can be reduced by 30 percent.</text>
  </section>
  <section number="4-260" name="Electrical Power and Lighting Systems (Mandatory); C405.10. Solar Energy Systems" law="code" slug="sec-4-260" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_4BU_DIV1BUCO_SD5INENCOCO_S4-260ELPOLISYMAC4SOENSY">
    <text>Section C405.10. Provide adequate on-site access for solar energy systems and provide interconnection pathways to building distribution. Documentation must be provided through construction documents and the main electrical service panel.</text>
  </section>
  <section number="4-261" name="Additional Efficiency Package Options; C406.5. On-site Renewable Energy" law="code" slug="sec-4-261" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_4BU_DIV1BUCO_SD5INENCOCO_S4-261ADEFPAOPC4TEREEN">
    <text>Section C406.5. Total minimum ratings of on-site renewable energy systems shall comply with one of the following: 1. Provide not less than 1.75 Btu (1850 W), or not less than 0.50 watts per square foot (5.4 W/m2) or conditioned floor area. 2. Provide not less than 5 percent of the energy used within the building for building mechanical and service water heating equipment and lighting regulated in this chapter.</text>
  </section>
  <section number="4-262" name="Additional Efficiency Package Options; C406.5, District Energy Systems" law="code" slug="sec-4-262" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_4BU_DIV1BUCO_SD5INENCOCO_S4-262ADEFPAOPC4DIENSY">
    <text>Section C406.5 is added to read as follows: A minimum of 40 percent of heating and cooling load as calculated in section C403.2.2 must be provided by a district energy system.</text>
  </section>
  <section number="4-263" name="Additional Efficiency Package Options; C406.9. Water Heating Needs" law="code" slug="sec-4-263" node_id="PTIITI17PULOLAPRGECOMA_SUBTITLE_4BU_DIV1BUCO_SD5INENCOCO_S4-263ADEFPAOPC4WAHENE">
    <text>Section C406.9. Hotels, motels, hospitals, restaurants, buildings with residential occupancies, buildings with laundry facilities or other high process service water heating needs or buildings showing a service hot water load of 10 percent or more of total building energy shall provide at least forty percent (40%) of hot water through instantaneous or tankless fuel-fired water heating systems, waste heat recovery from equipment or Combined Heat and Power (CHP), solar water heating systems.</text>
  </section>