<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".34" citation="COMAR 09.12.01.34" title_num="09" subtitle_num="12" chapter_num="01" heading="Historic Boilers.">
  <paragraph num="A.">
    <text>Except as provided for in this regulation, a historical boiler shall be installed, inspected, operated, repaired, or altered in accordance with the NBIC.</text>
  </paragraph>
  <paragraph num="B.">
    <text>Inspection.</text>
    <paragraph num="(1)">
      <text>An initial inspection shall be conducted:</text>
      <paragraph num="(a)">
        <text>To determine baseline criteria needed for the operating life of the boiler;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>In accordance with the requirements outlined in the NBIC;</text>
      </paragraph>
      <paragraph num="(c)">
        <text>On any boiler not previously inspected in Maryland; and</text>
      </paragraph>
      <paragraph num="(d)">
        <text>On any boiler which has not received a certificate inspection in Maryland in the previous 2 years.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>Except as provided in this subsection, a historical boiler shall be inspected at the inspection intervals of the NBIC:</text>
      <paragraph num="(a)">
        <text>An internal inspection shall be conducted annually;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>An external inspection shall be conducted annually;</text>
      </paragraph>
      <paragraph num="(c)">
        <text>After a repair or alteration, a historical boiler shall be inspected before operation; and</text>
      </paragraph>
      <paragraph num="(d)">
        <text>If an inspection detects a condition warranting further investigation, an inspector may require further investigation.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>Before an inspection, an owner shall, upon request, provide the inspector with:</text>
      <paragraph num="(a)">
        <text>Stress calculations in accordance with this regulation;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The calculated factor of safety;</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Requested maximum allowable operating pressure;</text>
      </paragraph>
      <paragraph num="(d)">
        <text>The two most recent ultrasonic thickness examination maps; and</text>
      </paragraph>
      <paragraph num="(e)">
        <text>Any other documentation required by the NBIC.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>During an inspection, an inspector may:</text>
      <paragraph num="(a)">
        <text>Examine all documents pertaining to the qualifications of the operator; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Assess an operator’s demonstrated understanding of the operational requirements of the historical boiler.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>Hydrostatic Pressure Test.</text>
    <paragraph num="(1)">
      <text>A historical boiler shall be hydrostatically tested to a pressure of not less than the maximum allowable operating pressure but no more than 1-1/4 times the maximum allowable operating pressure.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>After a repair or alteration, a historical boiler shall be tested hydrostatically to a pressure of not less than 1¼ times the maximum allowable operating pressure but no more than 1½ times the maximum allowable operating pressure.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>An owner shall supply the necessary test equipment required by the inspector for the hydrostatic test including:</text>
      <paragraph num="(a)">
        <text>Water source, pump, pressure lines, and calibrated test gauge; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Plugs, gags, or caps to replace safety valves or other appurtenances if needed to prevent damage from the required test pressure.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>Maximum Allowable Operating Pressure.</text>
    <paragraph num="(1)">
      <text>The maximum allowable operating pressure shall be determined by the inspector in accordance with the NBIC and ASME Code.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>The maximum allowable operating pressure for objects containing wrought iron will be determined by considering the following:</text>
      <paragraph num="(a)">
        <text>For pressures up to 250 psi a temperature allowance is not required; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>For pressures above 250 psi the allowable stress values shall comply with the requirements of the ASME Code, Section I, Part PG-23.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>The maximum allowable operating pressure for objects containing materials other than carbon steel or wrought iron shall be determined in accordance with the ASME Code.</text>
    </paragraph>
  </paragraph>
  <paragraph num="E.">
    <text>Training.</text>
    <paragraph num="(1)">
      <text>A person who operates a historical boiler shall retain a written record of their training.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Upon request, a person who operates a historical boiler shall provide the Chief Boiler Inspector with a copy of their training record.</text>
    </paragraph>
  </paragraph>
  <paragraph num="F.">
    <text>Historical boilers with a certificate of inspection issued by another jurisdiction may operate in Maryland under the following circumstances:</text>
    <paragraph num="(1)">
      <text>An owner of a historical boiler may request that the Chief Boiler Inspector recognize a certificate of inspection issued by another jurisdiction;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>In evaluating a request for recognition of a certification of inspection by the other jurisdiction, the Chief Boiler Inspector may conduct an inspection of a historical boiler to verify:</text>
      <paragraph num="(a)">
        <text>Compliance with the NBIC; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Satisfaction of safety requirements that are equal to or greater than Maryland’s requirements;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>If the Chief Boiler Inspector conducts an inspection to evaluate a historical boiler with a certificate of inspection from the other jurisdiction, the Chief Boiler Inspector shall examine the following:</text>
      <paragraph num="(a)">
        <text>Verification and validation of the certificate of inspection from the other jurisdiction;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Examination of all documents required by this regulation and by the NBIC;</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Examination of all documents pertaining to the qualifications of the operator;</text>
      </paragraph>
      <paragraph num="(d)">
        <text>Demonstrated understanding of the operational requirements by the operator of the historical boiler; and</text>
      </paragraph>
      <paragraph num="(e)">
        <text>Other tests at the discretion of the inspector including but not limited to:</text>
        <paragraph num="(i)">
          <text>An external inspection;</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>A determination of the maximum allowable operating pressure in Maryland; and</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Operation at the maximum allowable operating pressure in Maryland; and</text>
        </paragraph>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>If the Chief Boiler Inspector determines that a historical boiler with a certificate of inspection issued by another jurisdiction is in compliance with safety requirements that are equal to or greater than Maryland, the Chief Boiler Inspector shall issue a certificate of inspection.</text>
    </paragraph>
  </paragraph>
  <paragraph num="G.">
    <text>A historical portable steam boiler shall not be operated at a pressure greater than:</text>
    <paragraph num="(1)">
      <text>15 psig when being moved at a speed of 5 miles per hour or less; and</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Zero psig when being moved at a speed greater than 5 miles per hour.</text>
    </paragraph>