<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".05" citation="COMAR 09.12.63.05" title_num="09" subtitle_num="12" chapter_num="63" heading="Daily Inspections.">
  <paragraph num="A.">
    <text>Inspections and Records.</text>
    <paragraph num="(1)">
      <text>In accordance with COMAR 09.12.62.09, the water slide owner shall ensure that the water slide is inspected on each day of use to determine that:</text>
      <paragraph num="(a)">
        <text>The water slide is in safe operating condition; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Conforms to the requirements in this chapter and COMAR 09.12.62.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>The owner shall ensure that the inspections are conducted in a manner which permits close scrutiny of the slide and all of its parts.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Appropriate records shall be kept.</text>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>The flume shall be inspected before the water is circulated, and in accordance with the manufacturer's specifications.</text>
  </paragraph>
  <paragraph num="C.">
    <text>Before the water is circulated, the water slide shall be inspected for safety hazards, including, but not limited to:</text>
    <paragraph num="(1)">
      <text>Loose railings;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Leaking seals at the butt-joints which affect operational safety;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Rough patching of cracks or joints;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Loose or missing guards on the flume turns;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>Sharp edges on the flume safety rails;</text>
    </paragraph>
    <paragraph num="(6)">
      <text>Projections into the flume troughs;</text>
    </paragraph>
    <paragraph num="(7)">
      <text>Unusual movement of the flume bed;</text>
    </paragraph>
    <paragraph num="(8)">
      <text>Evidence of deterioration of the wooden flume support structures;</text>
    </paragraph>
    <paragraph num="(9)">
      <text>An obstructed view of the splash pool at the exit of the flume.</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>During slide operation the owner or the owner's designee shall periodically:</text>
    <paragraph num="(1)">
      <text>Observe the movement of the sliders, including:</text>
      <paragraph num="(a)">
        <text>The location of the sliders' bodies on side walls during turns;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Sliders' impacts with flume walls; and</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Safety during sliders' exits into the splash pool;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>Determine if any injuries have occurred which indicate a water slide hazard which may require additional inspection;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Ensure that there is a proper and steady flow of water throughout the flume.</text>
    </paragraph>
  </paragraph>
</regulation>