<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".07" citation="COMAR 09.12.63.07" title_num="09" subtitle_num="12" chapter_num="63" heading="Design Criteria.">
  <paragraph num="A.">
    <text>Scope.</text>
    <paragraph num="(1)">
      <text>The design criteria contained in COMAR 09.12.62.10 apply to all water slides.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>The criteria contained in this regulation shall apply to any slide for which:</text>
      <paragraph num="(a)">
        <text>A construction permit is issued after the effective date of this chapter; or</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Construction or renovation has begun after the effective date of this chapter.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>Overall Design.</text>
    <paragraph num="(1)">
      <text>The slide's structural design and materials shall:</text>
      <paragraph num="(a)">
        <text>Comply with generally accepted structural engineering practices; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Provide a durable frame which shall safely sustain all weights and pressures for the projected operating life of the structure.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>The materials for components and accessories to be used in and around slides shall be such that the operational strength of the entire assembly and its components is not adversely affected by exposure to rain, snow, ice, sunlight, local normal temperature extremes, local normal wind variations, local air pollution products, and the mechanical, electrical, and chemical environment in and around the slides.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Materials selected for components and accessories used in and around slides shall be such that all parts with external surfaces and edges that may come in contact with the slider are assembled, arranged, and finished so that they do not constitute a cutting, pinching, puncturing, or abrasion hazard in casual contact or intended use.</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Surfaces shall be inert, nontoxic, smooth, and easy to clean.</text>
    </paragraph>
    <paragraph num="(5)">
      <text>The flumes shall be designed or ventilated, or both, to prevent concentrations of toxic disinfectant fumes.</text>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>Water Slide Flume.</text>
    <paragraph num="(1)">
      <text>Curves, turns, and tunnels within the path of a slide flume shall be designed so that body impact with the walls of the flume or ceiling of a tunnel does not present a hazard.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>The slide flume shall be banked to keep the slider's body safely inside the flume or curve under all foreseeable circumstances.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Slopes within the path of the slide flume shall be designed so that the slider's speed does not exceed the level when a safe equilibrium of dynamic forces can be maintained on any curve or turn.</text>
    </paragraph>
    <paragraph num="(4)">
      <text>The construction, dimensions, and attachment of slide flume bed components shall be such that the surface of the slide flume is continuous and smooth.</text>
    </paragraph>
    <paragraph num="(5)">
      <text>The walls of the flume shall be designed so that the continuous and combined action of hydrostatic, dynamic, and static loads, and normal environmental deterioration do not cause structural failures which could result in injury or require patching of the original structure.</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>Flume Exit.</text>
    <paragraph num="(1)">
      <text>When the water slide ends in a splash pool, the following requirements apply:</text>
      <paragraph num="(a)">
        <text>The pool shall be of sufficient length and width so as to preclude a slider from contacting the walls, adjacent flume exits, and sliders exiting from multiple exit flumes;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Unless the manufacturer specifies otherwise, the flumes shall terminate:</text>
        <paragraph num="(i)">
          <text>At a depth of at least 6 inches below the splash pool's operating water surface level; or</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>If the flume is level for a distance of at least 10 feet from its exit, at a height not more than 2 inches above the water's surface.</text>
        </paragraph>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>When the water slide ends in a runout, the owner shall ensure that the runout is of a sufficient length to allow for the safe deceleration of sliders.</text>
    </paragraph>
  </paragraph>
  <paragraph num="E.">
    <text>Splash Pool.</text>
    <paragraph num="(1)">
      <text>Unless the manufacturer specifies otherwise, a splash pool depth of at least 3 feet shall be provided at the end of each flume for a distance of at least 20 feet.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Inlets from the water circulation system shall be designed so as to prevent injury to the splash pool user.</text>
    </paragraph>
  </paragraph>
</regulation>