<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".02" citation="COMAR 09.12.81.02" title_num="09" subtitle_num="12" chapter_num="81" heading="Safety Standard for Platform Lifts and Stairway Chairlifts.">
  <paragraph num="A.">
    <text>Scope.</text>
    <paragraph num="(1)">
      <text>The following sections set out the dates on which ANSI/ASME codes and supplements for platform lifts and stairway chairlifts, as required by Public Safety Article, §12-805, Annotated Code of Maryland, became effective.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Requirements prescribed at the time of the initial platform lift and stairway chairlift certification remain in effect.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>ASME A18.1-1999 Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference and is effective April 1, 2002.</text>
    </paragraph>
    <paragraph num="(4)">
      <text>ASME A18.1a-2001 Addenda to ASME A18.1-1999 Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference, as amended, and is effective March 4, 2013.</text>
    </paragraph>
    <paragraph num="(5)">
      <text>ASME A18.1b-2001 Addenda to ASME A18.1-1999 Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference, as amended, and is effective March 4, 2013.</text>
    </paragraph>
    <paragraph num="(6)">
      <text>ASME A18.1-2003 (Revision of ASME A18.1-1999) Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference, as amended, and is effective March 4, 2013.</text>
    </paragraph>
    <paragraph num="(7)">
      <text>ASME A18.1-2005 (Revision of ASME A18.1-2003) Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference, as amended, and is effective March 4, 2013.</text>
    </paragraph>
    <paragraph num="(8)">
      <text>ASME A18.1-2008 (Revision of ASME A18.1-2005) Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference, as amended, and is effective March 4, 2013.</text>
    </paragraph>
    <paragraph num="(9)">
      <text>ASME A18.1-2011 (Revision of ASME A18.1-2008) Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference.</text>
    </paragraph>
    <paragraph num="(10)">
      <text>ASME A18.1-2014 (Revision of ASME A18.1-2011) Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference.</text>
    </paragraph>
    <paragraph num="(11)">
      <text>ASME A18.1-2017 (Revision of ASME A18.1-2014) Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference.</text>
    </paragraph>
    <paragraph num="(12)">
      <text>ASME A18.1-2020 (Revision of ASME A18.1-2017) Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference.</text>
    </paragraph>
    <paragraph num="(13)">
      <text>ASME A18.1-2023 (Revision of ASME A18.1-2020) Safety Standard for Platform Lifts and Stairway Chairlifts is incorporated by reference.</text>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>In addition to the requirements of Part XX, Inclined Stairway Chairlifts and Inclined and Vertical Wheelchair Lifts, of the A17.1-Safety Code for Elevators, and the requirements of ASME A18.1-1999 Safety Standard for Platform Lifts and Stairway Chairlifts, and all subsequent amendments, §§CF of this regulation apply.</text>
  </paragraph>
  <paragraph num="C.">
    <text>General Requirements.</text>
    <paragraph num="(1)">
      <text>Vertical and inclined wheelchair lifts and inclined stairway chairlifts may be used only by physically handicapped individuals, and may not be modified from their intended use.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>A sign, indicating that the lift is for use by the physically handicapped only, shall be posted at the top and bottom landings of the lift runway.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Disconnecting Device.</text>
      <paragraph num="(a)">
        <text>A main line disconnecting device lockable only in the “OFF” position shall be provided.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The disconnecting device shall be located within view of the lift motor.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>Vertical Wheelchair Lift.</text>
    <paragraph num="(1)">
      <text>Adequate car illumination shall be provided during lift operation.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>An attendant-operated lift shall be operated by a key-activated continuous-pressure switch.</text>
    </paragraph>
  </paragraph>
  <paragraph num="E.">
    <text>Inclined Wheelchair Lift.</text>
    <paragraph num="(1)">
      <text>The edge of the lift's foot rest, facing the upper landing, may not extend more than 12 inches above a step or landing as measured vertically.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Self-Closing Door.</text>
      <paragraph num="(a)">
        <text>The platform shall be equipped with a self-closing door on the sides of access to the upper and lower landings.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The self-closing door shall be operable within 2 inches of the upper and lower landings.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>A lift shall be provided with a permanently attached folding seat and seatbelt to accommodate a person not in a wheelchair.</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Attendant Operation.</text>
      <paragraph num="(a)">
        <text>An attendant-operated lift shall be operated by a key-activated continuous-pressure switch.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>When the equipment operates on a straight flight of stairs and the platform is within sight during its entire travel, the attendant shall operate the unit from the bottom of the stairs.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="F.">
    <text>Inclined Stairway Chairlift. The edge of the lift's foot rest, facing the upper landing, may not extend more than 12 inches above a step or landing as measured vertically.</text>
  </paragraph>
</regulation>