Regulation .01 Incorporation by Reference.
Regulation .01 Incorporation by Reference.LinkCopy Citation
A.
Purpose. These regulations establish safety standards for the design, construction, installation, operation, inspection, and maintenance of personnel hoists.
B.
The American National Standard Safety Requirements for Personnel Hoists and Employee Elevators for Construction and Demolition Operations, ANSI A10.4—1990, is incorporated by reference, with the following changes:
(1)
On page 1, under Section 2.1, Related American National Standards, delete reference to ANSI/ASME A17.1—1987 and insert in its place the following: American National Standard Safety Code for Elevators, Dumbwaiters, Escalators, and Moving Walks, ASME A17.1, as adopted by the Commissioner of Labor and Industry.
(2)
On page 2, under Section 2.3, Referenced Standards, delete reference to ANSI/ASME A17.1—1988 and insert in its place the following: American National Standard Safety Code for Elevators, Dumbwaiters, Escalators, and Moving Walks, ASME A17.1, as adopted by the Commissioner of Labor and Industry.
(3)
On pages 8 and 9, delete the following definitions:
(4)
On page 11, delete the text under Section 4, Temporary Use of Permanent Elevators for Carrying Workers or Materials, and insert in its place the following: Section 4. Permanent passenger or freight elevators installed in buildings under construction, modification, or demolition may be used for carrying workers or materials, or both, provided the elevators are approved for such use and a temporary permit therefore is issued for the class of service for which approval is granted by the department having jurisdiction. Elevators for handling personnel during construction that operate in permanent hoistways on the permanent guide rails shall conform to the requirements of the current edition of the American National Standard Safety Code for Elevators, Dumbwaiters, Escalators, and Moving Walks, ASME A17.1, as adopted by the Commissioner of Labor and Industry, that apply to this type of operation.
(5)
On page 24, delete the text under Section 14.3.1 and insert the following: When oil buffers are used they shall comply with Part II, Section 201, Rule 201.4 of ASME A17.1, as adopted by the Commissioner of Labor and Industry.
(6)
On page 45, delete Section 24.1.2.1 Automatic Operating Devices.
(7)
On page 45, delete Section 24.1.2.2.
(8)
On page 46, delete the text under Section 24.1.3, Top-of-Car Operation During Inspection, and insert the following:
(9)
On page 46, delete Section 24.1.4. Wireless Control.
(10)
On page 46, delete Section 24.1.5 Design Principle for Wireless Control.
(11)
On page 56, delete the text under Section 26.3, Acceptance Tests of Buffers for Car and Counterweight, and insert the following: No acceptance test shall be required for spring-type buffers. Oil buffers shall be tested in the field in accordance with Part X, Section 1000, Rule 1000.3 of ASME A17.1, as adopted by the Commissioner of Labor and Industry.
(12)
On page 57, delete the text under Section 26.6 Operation and insert the following: Except for requirements relating to automatic operation and wireless control, hoists shall be operated in compliance with the manufacturing specifications, rules, and recommendations, and the same of the governing authority. This shall consist of items, functions and criteria pertaining to the hoist use and shall be a part of an operational maintenance and inspection log.
(13)
On page 57, delete Section 26.6.1.
(14)
On page 59, delete the text under Section 29 Posting of Operating Permits and insert the following: Permits shall be posted in accordance with Regulation .02 of this chapter.
C.
American National Standard ANSI/ASSE A10.4 — 2007 Personnel Hoists and Employee Elevators on Construction and Demolition Sites, is incorporated by reference.
D.
American National Standard ANSI/ASSE A10.4 — 2016 Safety Requirements for Personnel Hoists and Employee Elevators on Construction and Demolition Sites, is incorporated by reference.
E.
Article 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts of the National Electric Code (NFPA 70), which is incorporated by reference in COMAR 09.12.50.02-1B(3).