<subtitle num="20" heading="Board of Plumbing" title_num="09" title_heading="Maryland Department of Labor">
  <chapter num="01" heading="State Plumbing Code">
    <regulation prefix="Regulation" num=".01" heading="Incorporation by Reference.">
      <paragraph num="A.">
        <text>In this chapter, the documents set forth in §B of this regulation are incorporated by reference.</text>
      </paragraph>
      <paragraph num="B.">
        <text>In compliance with Business Occupations and Professions Article, §§12-101(p) and 12-205(a), Annotated Code of Maryland, the Board adopts the most recent version of the following Codes as they may be amended, modified, or updated from time to time.</text>
        <paragraph num="(1)">
          <text>The International Plumbing Code (International Code Council, 500 New Jersey Avenue, N.W., 6th Floor, Washington, DC 20001), which has been incorporated by reference in COMAR 09.12.50.02-1B(2).</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The International Residential Code, (International Code Council, 500 New Jersey Avenue, N.W., 6th Floor, Washington, DC 20001), which has been incorporated by reference in COMAR 09.12.50.02-1B(4) and 09.12.51.04A(2).</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The International Fuel Gas Code (International Code Council, 500 New Jersey Avenue, N.W., 6th Floor, Washington, DC 20001).</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The most recent version of the National Fuel Gas Code, NFPA 54.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>The Liquefied Petroleum Gas Code, NFPA 58.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Modifications to the International Plumbing Code. — Repealed." />
    <regulation prefix="Regulation" num=".03" heading="Modifications to the International Residential Code. — Repealed." />
    <regulation prefix="Regulation" num=".04" heading="Modifications to the National Fuel Gas Code, ANSI Z223.1, NFPA 54. — Repealed." />
    <regulation prefix="Regulation" num=".05" heading="Limit on Lead Content.">
      <paragraph num="A.">
        <text>Definitions.</text>
        <paragraph num="(1)">
          <text>In this regulation, the following terms have the meanings indicated.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Terms Defined.</text>
          <paragraph num="(a)">
            <text>“Lead-free” means:</text>
            <paragraph num="(i)">
              <text>Containing not more than a weighted average of 0.25 percent lead when used with respect to the wetted surface of pipes, pipe fitting, plumbing fittings, and fixtures; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Not containing more than 0.2 percent lead when used with respect to solder and flux.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>“NSF” means the standards of the National Sanitation Foundation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Weighted Average Lead Content Formula.</text>
        <paragraph num="(1)">
          <text>The weighted average lead content of a lead-free pipe, pipe fitting, plumbing fitting, or fixture shall be calculated by using the following formula: For each wetted component, the percentage of lead in the component shall be multiplied by the ratio of the wetted surface area of that component to the total wetted surface area of the entire product to arrive at the weighted percentage of lead of the component. The weighted percentage of lead of each wetted component shall be added together, and the sum of these weighted percentages shall constitute the weighted average lead content of the product. The lead content of the material used to produce wetted components shall be used to determine compliance with lead-free requirements. For lead content of materials that are provided as a range, the maximum content of the range shall be used.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The use of platings, coatings, or acid wash treatments may not be used to meet the 0.25 percent weighted average lead content requirements set forth in Business Occupations and Professions Article, §§12-101(h-1)(4) and 12-101(q)(4) and(5), Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Materials used to dispense water intended for human consumption through drinking or cooking, including piping, faucets, and valves as set forth in §§F and G of this regulation, shall be lead-free, containing not more than a weighted average of 0.25 percent lead with respect to the wetted surface as defined in §A(2)(a)(ii) of this regulation.</text>
      </paragraph>
      <paragraph num="D.">
        <text>Soldered Joints.</text>
        <paragraph num="(1)">
          <text>Solder and flux for soldered joints in potable water piping shall be lead-free, containing not more than 0.2 percent lead, as defined in §A(2)(a)(ii) of this regulation.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Flux shall be recommended by the manufacturer for making soldered joints in lead-free potable water supply system piping.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Components.</text>
        <paragraph num="(1)">
          <text>Potable water supply components that are within the scope of NSF 61 for drinking water system components and are required to be lead-free shall comply with NSF 61 and NSF 372.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Potable water system components that are not within the scope of NSF 61 for drinking water system components but are required to be lead-free shall comply with NSF 372.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Potable water system components that are not required to be 0.25% lead-free shall be suitable for distributing potable water but may contain up to 8% lead.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>Potable water end-use devices and potable water supply system piping that are intended to dispense water for human consumption through drinking or cooking include, but are not limited to:</text>
        <paragraph num="(1)">
          <text>Kitchen sink faucets;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Bar sink faucets;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Private bathroom sink faucets;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Drinking fountain faucets;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Kitchen hot water dispensers;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Water supply to:</text>
          <paragraph num="(a)">
            <text>Ice makers;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Potable water heaters;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Commercial grocer or supermarket misting systems used for produce;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Commercial kitchen cooking equipment; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Production equipment for processed food containing water; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>Any other end-use device or piping that is intended to dispense or convey water for human consumption.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>Piping components that shall be lead-free when used with lead-free end-use devices and piping that are required to be lead-free include, but are not limited to:</text>
        <paragraph num="(1)">
          <text>Main service shut-off valves;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Water service backflow prevention devices;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Water meters;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Pressure booster pumps;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Pressure reducing valves;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Strainers;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Water filters;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Check valves;</text>
        </paragraph>
        <paragraph num="(9)">
          <text>Control valves;</text>
        </paragraph>
        <paragraph num="(10)">
          <text>Vacuum breakers;</text>
        </paragraph>
        <paragraph num="(11)">
          <text>Water hammer arrestors;</text>
        </paragraph>
        <paragraph num="(12)">
          <text>Master hot water mixing valves;</text>
        </paragraph>
        <paragraph num="(13)">
          <text>In-line tempering valves;</text>
        </paragraph>
        <paragraph num="(14)">
          <text>Hot water recirculating pumps;</text>
        </paragraph>
        <paragraph num="(15)">
          <text>Branch piping shut off valves;</text>
        </paragraph>
        <paragraph num="(16)">
          <text>Balancing valves;</text>
        </paragraph>
        <paragraph num="(17)">
          <text>Fixture shut off valves;</text>
        </paragraph>
        <paragraph num="(18)">
          <text>Solenoid valves;</text>
        </paragraph>
        <paragraph num="(19)">
          <text>Tankless water heaters; and</text>
        </paragraph>
        <paragraph num="(20)">
          <text>Any other piping component associated with an end-use device or water supply piping that is required to be lead-free.</text>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>Materials Not Required to Be Lead-Free.</text>
        <paragraph num="(1)">
          <text>Pipes, pipe fittings, plumbing fittings or fixtures, including backflow preventers, that are used exclusively for nonpotable services such as manufacturing, industrial processing, irrigation, outdoor watering, or any other uses where the water is not anticipated to be used for human consumption are not required to be lead-free.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Potable water end-use devices and water supply system components not anticipated to dispense or convey water to be used for human consumption and not required to be lead-free, including the associated supply piping of such devices and components, include, but are not limited to:</text>
          <paragraph num="(a)">
            <text>Tub faucets or fillers;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Shower fixtures, including:</text>
            <paragraph num="(i)">
              <text>Valves;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Heads; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Adapters;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Flush valves for:</text>
            <paragraph num="(i)">
              <text>Water closets;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Urinals; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Bidets;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>Shut off valves for clothes washers;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Lavatory faucets in public restrooms;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Laundry sink faucets;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Service sink faucets;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Faucets for laboratory applications;</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Hose bibbs;</text>
          </paragraph>
          <paragraph num="(j)">
            <text>Trap seal priming devices;</text>
          </paragraph>
          <paragraph num="(k)">
            <text>Backflow prevention devices that supply nonpotable applications;</text>
          </paragraph>
          <paragraph num="(l)">
            <text>Fire hose valves;</text>
          </paragraph>
          <paragraph num="(m)">
            <text>Water hammer arrestors;</text>
          </paragraph>
          <paragraph num="(n)">
            <text>The water supply to:</text>
            <paragraph num="(i)">
              <text>Dishwashers;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Whirlpools;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Spas;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Therapy pools;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Swimming pools;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Boilers;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>Heating hot water generators;</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>Humidifiers; and</text>
            </paragraph>
            <paragraph num="(ix)">
              <text>Irrigation systems;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(o)">
            <text>Food production equipment that does not contact the food; and</text>
          </paragraph>
          <paragraph num="(p)">
            <text>Any other end-use device or water supply piping that is not anticipated to dispense or convey water that is to be used for human consumption.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Business Occupations and Professions Article, §§12-205 and 12-207, Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date:</annotation>
      <annotation type="History" subtype="Administrative History">COMAR 09.20.01—09.20.25 repealed and new Regulations .01 and .02 adopted under a new chapter, State Plumbing Code, effective October 20, 1997 (24:21 Md. R. 1448)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01B amended effective July 23, 2001 (28:14 Md. R. 1321); May 9, 2005 (32:9 Md. R 848); May 18, 2009 (36:10 Md. R. 716); May 13, 2013 (40:9 Md. R. 789); January 2, 2017 (43:26 Md. R. 1444)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02 amended effective July 23, 2001 (28:14 Md. R. 1321); May 9, 2005 (32:9 Md. R. 848); May 18, 2009 (36:10 Md. R. 716); May 13, 2013 (40:9 Md. R. 789); January 2, 2017 (43:26 Md. R. 1444)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02G, H amended effective January 29, 2000 (27:1 Md. R. 75)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02I amended effective May 12, 2003 (30:9 Md. R. 614)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03 adopted as an emergency provision effective January 1, 2012 (39:2 Md. R. 139); emergency extended at 39:13 Md. R. 785; adopted permanently effective February 4, 2013 (40:2 Md. R. 72)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03E amended effective January 2, 2017 (43:26 Md. R. 1444)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04 adopted effective May 13, 2013 (40:9 Md. R. 789)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04 amended effective January 2, 2017 (43:26 Md. R. 1444)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05 adopted effective January 2, 2017 (43:26 Md. R. 1444)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective December 30, 2019 (46:26 Md. R. 1163)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 amended effective November 24, 2025 (52:23 Md. R. 1138)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .02.—.04, .06, .07 repealed effective November 24, 2025 (52:23 Md. R. 1138)</annotation>
    </annotations>
  </chapter>
  <chapter num="02" heading="Enforcement of the Plumbing Law by the Board">
    <regulation prefix="Regulation" num=".01" heading="Qualifications of Plumbers—How Certificates May Be Issued.">
      <paragraph num="A.">
        <text>All plumbing work shall be performed, or supervised and approved, by a licensed master plumber who is:</text>
        <paragraph num="(1)">
          <text>Familiar with its design and purpose; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Available to direct and control all journey and apprentice plumbers.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The license of a master plumber will be issued in the name of the master plumber.</text>
      </paragraph>
      <paragraph num="C.">
        <text>All plumbing work performed, or supervised and approved, by a licensed master plumber shall be of ordinary worker-like skill and quality and shall conform both to the regulations promulgated by the Board and to applicable local laws and regulations.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Required Training for Apprentice Plumbers.">
      <paragraph num="A.">
        <text>Before an apprentice plumber may be examined for a license as a journey plumber, the apprentice plumber shall:</text>
        <paragraph num="(1)">
          <text>Receive at least 7,500 working hours of instruction and experience in the installation and repair of plumbing material and systems, under the direction and control of a master plumber; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Be registered with the Board for the duration of the apprenticeship training.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>To avoid undue hardship, the Board may give credit for hours worked in the installation and repair of plumbing material and systems by an unregistered apprentice plumber.</text>
      </paragraph>
      <paragraph num="C.">
        <text>It is recommended that the instruction and experience include:</text>
        <paragraph num="(1)">
          <text>Installation of piping for waste, soil, sewerage, vent and rain leader lines in copper,</text>
          <paragraph num="(a)">
            <text>Name and size of sewer fittings, wyes, tees, bend, packing, pouring, caulking joints;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Use of proper fittings in making connections;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Proper pitch in sewer lines;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Regulations on cesspools and septic tanks;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Local codes governing plumbing.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Installation of piping for hot and cold water for domestic purposes:	1,400 hrs.</text>
          <paragraph num="(a)">
            <text>Rough-in water and gas piping for fixtures;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Cut holes in floors and joist;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Measure up piping;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Run pipe in copper, steel, or plastic;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Installation of domestic water boilers and hot water heaters;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Install tankless or tank-type copper coil heaters in boilers;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Automatic gas water heaters with vent to chimney;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Measure up piping and connect to hot and cold water lines;</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Use of pipe cutters and reamers;</text>
          </paragraph>
          <paragraph num="(j)">
            <text>Cut threads with stocks and dies, or with pipe threading machines;</text>
          </paragraph>
          <paragraph num="(k)">
            <text>Use of joint compound on threads and screw up fittings on pipe with pipe wrenches;</text>
          </paragraph>
          <paragraph num="(l)">
            <text>Local codes governing plumbing.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Installation of lead pipe, tin pipe, sheet lead, and solder work: 	180 hrs.</text>
          <paragraph num="(a)">
            <text>Proper use of tools;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Kinds of materials and fluxes;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Correct heating temperatures.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Assembly in position and connection of fixtures and appliances used in the plumbing</text>
          <paragraph num="(a)">
            <text>Rough-in waste, soil, and vent lines for fixtures;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Pack, pour, and caulk fittings and pipe;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Make up fittings, run piping, and hook up main sewer;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Lay out water lines, hot and cold;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Place and connect various plumbing fixtures;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Local codes governing plumbing.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Service work—maintenance and repair of plumbing:	480 hrs.</text>
          <paragraph num="(a)">
            <text>Leaks;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Renewals;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Stoppage of lines;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Alterations;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Trouble shooting plumbing systems.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>Operation, care, safety, and use of all tools and materials connected with the trade:	 850 hrs.</text>
          <paragraph num="(a)">
            <text>Pipe and fittings, tees, ells, 45-degree ells and nipples;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Black, galvanized, wrought iron, wrought steel, copper, and plastic pipe;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Use and care of tools;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Pipe cutters, reamers, stocks and dies, size of wrenches, caulking irons, lead pots,</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Types of tubs—corner or recess, left or right;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Lavatories—cast iron, vitreous china, and stainless steel;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Closet combinations—vitreous china, closed couples, siphon action, flushometer types.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>Gas installation: 	750 hrs.</text>
          <paragraph num="(a)">
            <text>Types of gas installations—natural and LPG;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Venting gas systems;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Gas appliances and controls;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Local codes governing gas fitting.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(8)">
          <text>Special purpose installations: 	180 hrs.</text>
          <paragraph num="(a)">
            <text>Swimming pools;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Fountains and planters;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Lawn sprinkling and vacuum systems;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Local codes governing plumbing.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(9)">
          <text>Plan reading:	 375 hrs.</text>
          <paragraph num="(a)">
            <text>Sketching;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Sleeve drawing and deck layout;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Drawing coordination.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(10)">
          <text>Builders level transit: 	275 hrs.</text>
          <paragraph num="(a)">
            <text>Layout of sewer and water lines;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Shoot grades and elevations.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(11)">
          <text>Welding connected with the trade: 	480 hrs.</text>
          <paragraph num="(a)">
            <text>Gas, metallic arc, and heliarc welding;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Use of torch;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Proper flame, fluxes, and solder;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Pipe welding;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Proper welding procedures and techniques;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Identification of welding rods and materials;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Flame cutting;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Brazing.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(12)">
          <text>Rigging: 	375 hrs.</text>
          <paragraph num="(a)">
            <text>Materials;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Equipment.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Examinations for Journey Plumber Certificates.">
      <paragraph num="A.">
        <text>Each applicant for the journey plumber's examination shall provide certification that the applicant has accrued at least 7,500 working hours, that is, 4 years of apprenticeship instruction and experience in the installation and repair of plumbing material and systems, under the direction and control of a master plumber. The following conditions apply:</text>
        <paragraph num="(1)">
          <text>Up to 1,500 hours of accredited, approved school study may be applied towards the 7,500-hours requirement, which may be composed of classroom plumbing work or study under a vocational or technical program accredited by the State Department of Education or under the apprenticeship agreement registered with the Maryland Apprenticeship and Training Council;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The applicant shall furnish the certification, made under penalty of perjury, with the examination application;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Hours accrued may not be credited to an individual serving under an apprenticeship agreement registered with the Maryland Apprenticeship and Training Council unless the individual is also licensed with the Board as an apprentice plumber.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Examinations.</text>
        <paragraph num="(1)">
          <text>The Board shall examine qualified applicants by written examination.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If the applicant satisfactorily documents that the applicant has a disability as defined under The Americans With Disabilities Act (ADA), the Board will make those accommodations necessary for the administration of the examination.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An applicant shall attain a passing grade of 70 to qualify for licensure as a journey plumber.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Out-of-State Applicants.</text>
        <paragraph num="(1)">
          <text>A nonresident applicant or an applicant whose work experience has not been in Maryland shall provide certification that:</text>
          <paragraph num="(a)">
            <text>The applicant has accrued at least 7,500 working hours, that is, 4 years of apprenticeship instruction and experience in the installation and repair of plumbing material and systems, under the direction and control of a licensed master plumber; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The master plumber under whom the applicant trained received a license by passing a written competency examination.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Up to 1,500 hours of accredited, approved school study may be applied towards the 7,500-hour requirement.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The applicant shall furnish the certification as to accrued work experience and the qualifications of the supervisory master plumber, under penalty of perjury, with the examination application.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Examinations for Master Plumber Certificates.">
      <paragraph num="A.">
        <text>Each applicant for the master plumber's examination shall provide certification, under penalty of perjury, that the applicant has accrued at least 2 years, that is, 3,750 working hours of practical experience as a journey plumber, in the installation and repair of plumbing material and systems under the direction and control of a master plumber.</text>
      </paragraph>
      <paragraph num="B.">
        <text>The candidate shall be examined on:</text>
        <paragraph num="(1)">
          <text>General knowledge of the regulations as may be provided by the Board;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Knowledge of physics and hygiene as may deal with the proper and safe methods of supplying water to a building, and of removing water and sewage from it; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Drainage, hydraulics, pneumatics, and hydrostatics insofar as they relate to the proper construction of work required in providing plumbing services.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Applicants shall also be required to demonstrate their ability to comprehend and interpret plans and drawings, showing the arrangements of plumbing fixtures and other related parts of the plumbing system.</text>
      </paragraph>
      <paragraph num="D.">
        <text>Unless specifically provided for, each applicant shall answer all examination questions in writing.</text>
      </paragraph>
      <paragraph num="E.">
        <text>If the applicant satisfactorily documents that the applicant has a disability as defined under The Americans With Disabilities Act (ADA), the Board will make those accommodations necessary for the administration of the examination.</text>
      </paragraph>
      <paragraph num="F.">
        <text>If an applicant successfully completes the examination under §E of this regulation, the Board shall grant to the applicant a license as a master plumber upon a showing that the:</text>
        <paragraph num="(1)">
          <text>Applicant's ability to function as a master plumber is not significantly impaired by the dyslexia or other reading disability; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Applicant is otherwise competent and qualified to become a master plumber.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>Out-of-State Applicants.</text>
        <paragraph num="(1)">
          <text>A nonresident applicant or an applicant whose work experience has not been in Maryland shall accrue a total of at least 11,250 working hours, that is, 6 years of practical experience in the installation and repair of plumbing material and systems.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The applicant shall furnish information about the applicant's work experience, under penalty of perjury, as follows:</text>
          <paragraph num="(a)">
            <text>Certification of at least 4 years of the required total number of years, that is, 7,500 working hours spent in the installation and repair of plumbing material and systems under the direction and control of a licensed master plumber;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Certification of at least 2 years, that is, 3,750 hours of work in the plumbing trade as a journey plumber;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Certification that the journey plumber's license was received by passing a written competency examination; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Certification that the master plumber for whom the applicant worked received a license by passing a written competency examination.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>If the nonresident applicant is from an area that does not require licensure of journeyperson plumbers, and the applicant holds a master plumber's license, the applicant shall provide certification with the application that:</text>
          <paragraph num="(a)">
            <text>The applicant accrued at least 7,500 hours of practical experience in the plumbing trade under the direction and control of a licensed master plumber;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The master plumber for whom the applicant worked received a license by passing a written competency examination;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The applicant's master plumber license was received by passing a written competency examination; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The applicant has accrued at least 2 years, that is, 3,750 working hours in the installation and repair of plumbing material and systems since receiving the master plumber's license.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Passing Grade Required for a Master's License.">
      <text>An applicant shall attain a passing grade of 70 to quality for a license as a master plumber.</text>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Applicants Failed.">
      <paragraph num="A.">
        <text>Any applicant who failed the examination for either a master or journey license may apply and pay the prescribed fee for another examination. A period of 1 month shall elapse before a failed applicant may retake an examination.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Applicants who have failed an examination may review their examination papers upon written request to the Board. This request shall be made within 30 days after the applicant has been notified that the applicant failed to attain the required grade.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Applicants for Renewal of License.">
      <paragraph num="A.">
        <text>All apprentice, journey, and master plumbers eligible for renewal shall renew their licenses every 2 years.</text>
      </paragraph>
      <paragraph num="B.">
        <text>All applicants for renewal, after submitting their written application for renewal accompanied by the required fee, shall be issued a new license by the Board.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Any applicant for renewal who has for 5 consecutive years failed to renew a license is subject to examination before being issued a new license.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Issuing of License on a Reciprocal Basis.">
      <paragraph num="A.">
        <text>The Board shall issue a master or journey plumber license on a reciprocal basis to applicants living in Baltimore County or the Washington Suburban Sanitary District who:</text>
        <paragraph num="(1)">
          <text>Have passed the master or journey plumber examination in either jurisdiction;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Are in good standing in that jurisdiction; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Intend to do business in Maryland outside of Baltimore County or Washington Suburban Sanitary District.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The Board shall give examinations for journey or master plumber licenses to applicants living outside the State who:</text>
        <paragraph num="(1)">
          <text>Demonstrate that they have served an apprenticeship, or had practical experience, under supervision equivalent to that required in Maryland; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Demonstrate the same level of proficiency and study required of applicants serving an apprenticeship or gaining practical experience in Maryland.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".09" heading="Advertisements.">
      <paragraph num="A.">
        <text>Definitions. In this regulation, the following terms have the meanings indicated:</text>
        <paragraph num="(1)">
          <text>“Current master plumber” means the individual responsible for supervising and controlling the work of all individuals providing or assisting in providing plumbing services in a business.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>“Current natural gas fitter” means the individual responsible for supervising and controlling the work of all individuals providing or assisting in providing natural gas services in a business.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>“Current propane gas fitter” means the individual responsible for supervising and controlling the work of all individuals providing or assisting in providing propane gas services in a business.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>“License number” means the license registration certificate number displayed on the license document or propane gas fitter certificate issued to a licensee or certificate holder by the Board.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Requirements for Plumbers.</text>
        <paragraph num="(1)">
          <text>The license number of the current master plumber shall be displayed on all documents used by any person holding themselves out to the public as providing plumbing services.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Each vehicle that advertises plumbing services shall display the words “MD Licensed Plumber” and the license number of the current master plumber on both sides of the vehicle.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Requirements for Licensed Natural Gas Fitters.</text>
        <paragraph num="(1)">
          <text>The license number of the current natural gas fitter shall be displayed on all documents used by any person holding themselves out to the public as providing natural gas services.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Each vehicle that advertises natural gas services shall display the words “MD Licensed Natural Gas Fitter” and the license number of the current natural gas fitter on both sides of the vehicle.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Requirements for Propane Gas Fitters.</text>
        <paragraph num="(1)">
          <text>The license number of the current propane gas fitter shall be displayed on all documents used by any persons holding themselves out to the public as providing propane gas services.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Each vehicle that advertises propane gas services shall display the words “MD Certified Propane Gas Fitter” and the license number of the current propane gas fitter on both sides of the vehicle.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Additional Requirements for Licensees and Certificate Holders.</text>
        <paragraph num="(1)">
          <text>Each vehicle that advertises plumbing, natural gas, or propane gas services shall display the information required by this regulation on both sides of the vehicle. Display of wording shall be not less than 1-1/2 inches in height.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Each printed, audio, video, or computerized advertisement of any type, including all estimate forms, contract forms, and final statements of payment, shall clearly contain the words “MD Licensed Plumber”, “MD Licensed Natural Gas Fitter”, or “MD Certified Propane Gas Fitter” and the license number as required by §§B(2), C(2), and D(2) of this regulation.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".10" heading="Qualifications for Plumbing Inspectors.">
      <paragraph num="A.">
        <text>Plumbing inspectors hired by the State, a county, or a local government after October 1, 1988, shall meet minimum standards that are established by the county or local government in consultation with the State Board, or, if there is no standard established by the county or local government, the minimum standards established by the State Board. The minimum standards established by the State Board are as follows:</text>
        <paragraph num="(1)">
          <text>The plumbing inspector shall be a licensed master or journey plumber;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The plumbing inspector shall:</text>
          <paragraph num="(a)">
            <text>Have at least 4 years experience as an inspector or craftsman in a building and construction trade, and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Pass a written examination prepared and administered by the State Board, or prepared and administered by the county or local government, provided that the examination is approved by the State Board, and certified copies of all results are provided to the State Board.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Each plumbing inspector shall:</text>
        <paragraph num="(1)">
          <text>Attend, at least once each year, continuing education pursuant to Business Occupations and Professions Article, §12-503(a)(1), Annotated Code of Maryland, to be conducted by the State Board, or a course which is consistent in content with the State Board's course and which is conducted by a county or local government; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In accordance with Business Occupations and Professions Article, §12-503(a)(1), Annotated Code of Maryland, obtain a cumulative 8 hours of qualifying continuing education each calendar year.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".11" heading="Passing Grade for License and Certificate Examinations.">
      <text>In accordance with Business Occupations and Professions Article, §12-304(d)(1), Annotated Code of Maryland, and as set forth in Regulations .03B(3) and .05 of this chapter, an applicant for any license or certificate issued by the Board shall attain a passing score of 70 to qualify for the license or certificate.</text>
    </regulation>
    <annotations>
      <annotation type="Authority">Business Occupations and Professions Article, §§12-205, 12-207, 12-302(d), (e), (g)(2), and (h)(3), 12-304(d)(1), and 12-503(a), Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: 1971</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02, .13 amended effective January 7, 1976 (3:1 Md. R. 41)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07 amended effective February 8, 1980 (7:3 Md. R. 263)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .15 amended effective May 26, 1976 (3:11 Md. R. 592)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .17 amended effective December 24, 1975 (2:29 Md. R. 1735)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective October 26, 1981 (8:21 Md. R. 1706)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04 amended effective August 12, 1985 (12:16 Md. R. 1605)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04A amended effective April 21, 1986 (13:8 Md. R. 898)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05 amended effective April 21, 1986 (13:8 Md. R. 898)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05D adopted effective March 25, 1985 (12:6 Md. R. 595)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06 amended as an emergency provision effective July 1, 1983 (10:14 Md. R. 1257); adopted permanently effective September 26, 1983 (10:19 Md. R. 1690)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06 amended effective April 21, 1986 (13:8 Md. R. 898)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06G adopted effective March 25, 1985 (12:6 Md. R. 595)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .10A amended effective February 13, 1984 (11:3 Md. R. 199)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .12A amended effective August 12, 1985 (12:16 Md. R. 1605)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .12D adopted effective July 28, 1986 (13:15 Md. R. 1734)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .15 adopted effective June 26, 1989 (16:12 Md. R. 1335)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective June 22, 1992 (19:12 Md. R. 1133)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .11 adopted as an emergency provision effective March 1, 1995 (22:6 Md. R. 471); emergency status expired September 1, 1995</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .11 adopted effective March 25, 1996 (23:6 Md. R. 475)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter recodified from COMAR 09.20.26 to COMAR 09.20.02 effective October 20, 1997 (24:21 Md. R. 1448)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02 amended effective May 22, 2017 (44:10 Md. R. 472)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .03B amended effective October 20, 1997 (24:21 Md. R. 1448); June 17, 2019 (46:12 Md. R. 536)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .04E amended effective October 20, 1997 (24:21 Md. R. 1448)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05 amended effective June 17, 2019 (46:12 Md. R. 536)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06A amended effective June 24, 2002 (29:12 Md. R. 927)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07A amended effective May 22, 2017 (44:10 Md. R. 472)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09 amended effective November 29, 1999 (26:24 Md. R. 1857); March 18, 2002 (29:5 Md. R. 503)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .10B amended effective February 4, 2013 (40:2 Md. R. 72)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .11 amended as an emergency provision effective December 1, 2005 (32:26 Md. R. 1993); emergency status expired April 28, 2006</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .11 amended effective July 3, 2006 (33:13 Md. R. 1063)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .11 repealed effective May 22, 2017 (44:10 Md. R. 472)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .11 adopted effective June 17, 2019 (46:12 Md. R. 536)</annotation>
    </annotations>
  </chapter>
  <chapter num="03" heading="General Regulations">
    <regulation prefix="Regulation" num=".01" heading="Responsibilities of Licensees.">
      <paragraph num="A.">
        <text>A licensee shall undertake to provide plumbing services only if the licensee is qualified by education, training, and experience to provide the required services.</text>
      </paragraph>
      <paragraph num="B.">
        <text>A licensee shall undertake to provide plumbing services related to gas only if the licensee is qualified by education, training, and experience with the specific gas, gas system, gas utilization equipment, and associated accessories to provide the required services.</text>
      </paragraph>
      <paragraph num="C.">
        <text>A licensee may not use or allow the use of a license issued by the Board for the purpose of obtaining or attempting to obtain a permit or other authority to provide plumbing services from a county or local government agency unless the licensee is:</text>
        <paragraph num="(1)">
          <text>Familiar with the design and purpose of the plumbing services to be provided, and, when any portion of the services provided is to be outside of a permanent structure, the ground conditions of the area;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Available to direct and control all journey and apprentice plumbers who will provide or assist in the providing of the plumbing services; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Responsible for the services performed or to be performed pursuant to a contract.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>A licensee shall maintain appropriate insurance covering any plumbing service the licensee provides. Insurance provided by an employer does not satisfy the insurance requirements of Business Occupations and Professions Article, §12-501, Annotated Code of Maryland, if a licensee provides plumbing services outside the scope of employment with the insured person or business entity.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Street Address Required.">
      <paragraph num="A.">
        <text>This regulation applies to all applications, both original and renewal, received on or after January 1, 2014.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An applicant for a license shall provide to the Board the actual street address of the individual’s residence or principal business office. An applicant may not provide a post office box or private mail drop as the applicant's business address of record.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Failure to Respond.">
      <paragraph num="A.">
        <text>If an applicant or licensee receives from the Board a written communication requesting a response, the applicant or licensee shall respond in writing within 30 days of the date of the mailing.</text>
      </paragraph>
      <paragraph num="B.">
        <text>The Board shall send a written communication by first-class mail to the last address furnished to the Board by the applicant or licensee.</text>
      </paragraph>
      <paragraph num="C.">
        <text>It is the responsibility of an applicant or licensee to notify the Board in writing if there has been a change in an applicant’s or licensee’s address.</text>
      </paragraph>
      <paragraph num="D.">
        <text>Failure to respond as required by this regulation may be considered by the Board to be a violation of Business Occupations and Professions Article, §12-312(a)(1)(xiii), Annotated Code of Maryland.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Business Occupations and Professions Article, §§12-205, 12-207, 12-303(1), 12-311(c), and 12-312(a)(1)(xiii), Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: November 29, 1999 (26:24 Md. R. 1857)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01D adopted effective March 18, 2002 (29:5 Md. R. 503)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02 adopted effective December 12, 2013 (40:24 Md. R. 2016)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03 adopted effective December 31, 2018 (45:26 Md. R. 1241)</annotation>
    </annotations>
  </chapter>
  <chapter num="04" heading="Cross Connection/Backflow Prevention Certification Training Program">
    <regulation prefix="Regulation" num=".01" heading="Definitions.">
      <paragraph num="A.">
        <text>In this chapter, the following terms have the meaning indicated.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>“Certified instructor” means an individual who possesses a master plumber or a journey plumber license issued by the Board or a reciprocating jurisdiction and has successfully completed an instructional certification program sponsored by an organization recognized by the Board, including, but not limited to, the University of Florida Treeo Center (TREEO), American Society of Sanitary Engineering (ASSE) Instructor Accreditation Certification, and University of Southern California Foundation for Cross Connection Control.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>“Certified provider” means a person or organization who provides Board-approved cross connection/backflow prevention certification training in accordance with Business Occupations and Professions Article, §12-306(c), Annotated Code of Maryland, and meets the requirements of Regulation .02A—C of this chapter.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>“Certified technician” means an individual who is certified to install, test, repair, and make reports on a mechanical cross connection/backflow prevention device or assembly after successful completion of a 32-hour cross connection/backflow prevention certification program approved by the Board in accordance with Business Occupations and Professions Article, §12-306(c), Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Approved Cross Connection/Backflow Prevention Certification Program.">
      <paragraph num="A.">
        <text>In accordance with Business Occupations and Professions Article, §12-306(c), Annotated Code of Maryland, a cross connection/backflow prevention certification program may be eligible for approval by the Board if:</text>
        <paragraph num="(1)">
          <text>The certified provider submits to the Board an application on the form that the Board provides, identifying the course provider and the provider’s credentials to offer cross connection/backflow prevention certification training;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Each program instructor is a certified instructor in accordance with Regulation .01B(1) of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The course materials include a cross connection/backflow prevention training manual prepared by an organization identified in Regulation .01B(1) of this chapter;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>In the opinion of the Board, the course curriculum provides, at a minimum, adequate training in:</text>
          <paragraph num="(a)">
            <text>Introduction to backflow prevention;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Hazards of cross connection/backflow;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Laws of backflow prevention;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Responsibilities of certified technician;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The methods, mechanisms, and installation techniques used for the prevention of backflow;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Field testing;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Field reports;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Troubleshooting;</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Repair of a backflow occurrence; and</text>
          </paragraph>
          <paragraph num="(j)">
            <text>Recertification;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>The program is conducted at a facility that provides adequate space and a suitable training environment in the opinion of the Board that is:</text>
          <paragraph num="(a)">
            <text>Accessible for inspection by an authorized representative or agent of the Board during normal business and class hours without prior notice; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Equipped with adequate apparatus necessary for adequate training in the opinion of the Board including:</text>
            <paragraph num="(i)">
              <text>A test kit;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>One of each mechanical cross connection control device and assembly necessary for compliance with ASSE 1011, 1012, 1013, 1015, 1019, 1020, 1022, 1024, 1035, and 1056; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Mechanical cross connection control assembly set up for field testing;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>The certified provider issues to an individual who successfully completes the program a:</text>
          <paragraph num="(a)">
            <text>Certificate that includes:</text>
            <paragraph num="(i)">
              <text>The name of the certified provider;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The name of the certified technician to whom it is issued;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A statement that the course constitutes a 32-hour cross connection/backflow prevention certification program approved by the Maryland State Board of Plumbing;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The date of completion of the certification program;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>The name and signature of the course instructor; and</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>The certification technician number; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Pocket identification card that includes:</text>
            <paragraph num="(i)">
              <text>The name of the certified technician to whom it is issued;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The title “Certified Backflow Prevention Technician”;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The dates for which the certification is valid; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>The certified provider notifies the Board within 10 days of any change of a certified course instructor.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>In order for a cross connection/backflow prevention certification program to be and remain eligible for approval by the Board in accordance with Business Occupations and Professions Article, §12-306(c), Annotated Code of Maryland, the program must be able to demonstrate adequate recertification credentials including the:</text>
        <paragraph num="(1)">
          <text>Offer of recertification training for technicians every 5 years; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Requirement that course instructors maintain instructor certification by meeting the requirements of, but not limited to, the University of Florida Treeo Center (TREEO), American Society of Sanitary Engineering (ASSE) Instruction Accreditation Certification, and University of Southern California Foundation for Cross Connection Control, which shall include completion of recertification training at a minimum of once every 5 years.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>In addition to the requirements of §B of this regulation, in order for a cross connection/backflow prevention certification program to remain eligible for approval by the Board in accordance with Business Occupations and Professions Article, §12-306(c), Annotated Code of Maryland, every 3 years, the program provider shall provide the Board with updated information about the program which shall include:</text>
        <paragraph num="(1)">
          <text>A current list of certified instructors; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Notification from the certified provider of changes to the course curriculum or the location of the training facility.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>The Board may rescind its approval of a cross connection/backflow prevention certification program at any time if, in the opinion of the Board:</text>
        <paragraph num="(1)">
          <text>The certified provider demonstrates misconduct or incompetence in the performance of supervisory duties over the program;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A certified course instructor demonstrates misconduct or incompetence in the provision of applicable training; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The certified provider fails to meet any of the requirements of §§A—C of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>In accordance with Business Occupations and Professions Article, §§12-306(c)(3) and 12-503, Annotated Code of Maryland, an individual appointed, designated, or employed by a county or local government as an inspector of mechanical cross connection/backflow prevention devices shall have completed a cross connection/backflow prevention certification program approved by the Board.</text>
      </paragraph>
      <paragraph num="F.">
        <text>Completion of an approved cross connection/backflow prevention certification program does not authorize an individual to:</text>
        <paragraph num="(1)">
          <text>Install, test, or certify a mechanical cross connection/backflow prevention device unless the individual is licensed by the Board as a master or journey plumber in accordance with Business Occupations and Professions Article, §12-101(g) or (l), Annotated Code of Maryland; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Assist in installing, testing, or certifying a mechanical cross connection/backflow prevention device unless the individual is licensed by the Board as an apprentice plumber in accordance with Business Occupations and Professions Article, §12-101(c), Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Business Occupations and Professions Article, §§12-207 and 12-306(c), Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: July 22, 2013 (40:14 Md. R. 1174)</annotation>
    </annotations>
  </chapter>
  <chapter num="05" heading="Fees">
    <regulation prefix="Regulation" num=".01" heading="Purpose.">
      <text>This chapter is intended to carry out the provisions of Business Occupations and Professions Article, Title 12, Annotated Code of Maryland. and Business Regulation Article, §§2-106.9 and 2-106.10, Annotated Code of Maryland, In particular, it is intended to set various fees in order to cover the actual documented direct and indirect costs of fulfilling the statutory and regulatory duties of the State Board of Master Electricians, the State Board of Stationary Engineers, the State Board of Plumbing, and the State Board of Heating, Ventilation, Air-Conditioning, and Refrigeration Contractors.</text>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Definitions.">
      <paragraph num="A.">
        <text>In this chapter, the following terms have the meanings indicated.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>“Board” means the State Board of Plumbing.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>“License fee” means the fee paid by an applicant or licensee, as applicable, in connection with the issuance and renewal of a license and the issuance of a limited license and a reciprocal license.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>“Mechanical boards” means collectively the:</text>
          <paragraph num="(a)">
            <text>State Board of Master Electricians;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>State Board of Stationary Engineers;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>State Board of Plumbing; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>State Board of Heating, Ventilation, Air-Conditioning, and Refrigeration Contractors.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>“Secretary” means the Secretary of Labor.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Fees and Costs.">
      <paragraph num="A.">
        <text>The Secretary and the mechanical boards have agreed to average their direct and indirect costs, based on the calculation of costs performed by the Secretary in consultation with the mechanical boards. Based on these calculations, the Board sets the following nonrefundable fees as of January 1, 2024:</text>
        <paragraph num="(1)">
          <text>Application:</text>
          <paragraph num="(a)">
            <text>Master Natural Gas Fitter — $56;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Journey Natural Gas Fitter — $28;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Apprentice Plumber/Gas Fitter — $16.50;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Apprentice Natural Gas Fitter —$16.50; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Propane Gas Fitter Certificate — $28.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Original license and certificate:</text>
          <paragraph num="(a)">
            <text>Master Plumber/Gas Fitter — $78;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Journey Plumber/Gas Fitter — $39;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Limited Master Plumber — $78;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Limited Journey Plumber — $39;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Master Natural Gas Fitter — $78;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Journeyman Natural Gas Fitter — $39;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Propane Gas Fitter — $39;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Master Inspector — $50;</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Journeyman Inspector — $50; and</text>
          </paragraph>
          <paragraph num="(j)">
            <text>Plumbing Inspector — $50.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>License and certificate renewal:</text>
          <paragraph num="(a)">
            <text>Master Plumber/Gas Fitter — $78;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Journey Plumber/Gas Fitter — 39;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Apprentice Plumber/Gas Fitter —$16.50;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Limited Master Plumber — $78;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Limited Journey Plumber — $39;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Master Natural Gas Fitter — $39;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Journeyman Natural Gas Fitter — $28;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Apprentice Natural Gas Fitter — $16.50;</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Propane Gas Fitter — $39;</text>
          </paragraph>
          <paragraph num="(j)">
            <text>Master Inspector — $50;</text>
          </paragraph>
          <paragraph num="(k)">
            <text>Journeyman Inspector — $50; and</text>
          </paragraph>
          <paragraph num="(l)">
            <text>Plumbing Inspector — $50.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>License reactivation:</text>
          <paragraph num="(a)">
            <text>Master Plumber/Gas Fitter — $56;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Journey Plumber/Gas Fitter — $22.50;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Limited Master Plumber — $56; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Limited Journey Plumber — $22.50.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Miscellaneous: Letter of Good Standing — $50.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The Secretary and the mechanical boards have agreed to average their direct and indirect costs, based on the calculation of costs performed by the Secretary in consultation with the mechanical boards. Based on these calculations, the Board sets the following nonrefundable fees as of January 1, 2025:</text>
        <paragraph num="(1)">
          <text>Application:</text>
          <paragraph num="(a)">
            <text>Master Natural Gas Fitter — $63;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Journey Natural Gas Fitter — $31.50;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Apprentice Plumber/Gas Fitter — $18.50;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Apprentice Natural Gas Fitter — $18.50; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Propane Gas Fitter Certificate — $31.50.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Original license and certificate:</text>
          <paragraph num="(a)">
            <text>Master Plumber/Gas Fitter — $87.50;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Journey Plumber/Gas Fitter — $43.50;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Limited Master Plumber — $87.50;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Limited Journey Plumber — $43.50;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Master Natural Gas Fitter — $87.50;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Journeyman Natural Gas Fitter — $43.50;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Propane Gas Fitter — $43.50.</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Master Inspector — $56;</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Journeyman Inspector — $56; and</text>
          </paragraph>
          <paragraph num="(j)">
            <text>Plumbing Inspector — $56.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>License and certificate renewal:</text>
          <paragraph num="(a)">
            <text>Master Plumber/Gas Fitter — $87.50;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Journey Plumber/Gas Fitter — $43.50;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Apprentice Plumber/Gas Fitter — $18.50;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Limited Master Plumber — $87.50;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Limited Journey Plumber — $43.50;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Master Natural Gas Fitter — $43.50;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Journeyman Natural Gas Fitter — $31.50;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Apprentice Natural Gas Fitter — $18.50;</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Propane Gas Fitter — $43.50;</text>
          </paragraph>
          <paragraph num="(j)">
            <text>Master Inspector — $56;</text>
          </paragraph>
          <paragraph num="(k)">
            <text>Journeyman Inspector — $56; and</text>
          </paragraph>
          <paragraph num="(l)">
            <text>Plumbing Inspector — $56.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>License reactivation:</text>
          <paragraph num="(a)">
            <text>Master Plumber/Gas Fitter — $63;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Journey Plumber/Gas Fitter — $25;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Limited Master Plumber — $63; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Limited Journey Plumber — $25.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Miscellaneous Letter of Good Standing — $50.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An applicant for an appropriate license or certification examination shall pay the examination fee directly to the testing service chosen by the Board to develop or administer the examination, as such fees are established by the testing service selected by the Board.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Business Occupations and Professions Article, §§12-207, 12-209, 12-303, 12-304.1, 12-306, 12-308, and 12-503; Business Regulation Article, §§2-106.9 and 2-106.10; Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: August 27, 2018 (45:17 Md. R. 803)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03 amended effective March 4, 2024 (51:4 Md. R. 202)</annotation>
    </annotations>
  </chapter>
</subtitle>