<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".08" citation="COMAR 09.36.07.08" title_num="09" subtitle_num="36" chapter_num="07" heading="Electrical Systems.">
  <paragraph num="A.">
    <text>A home inspector shall visually inspect the accessible electrical system, including:</text>
    <paragraph num="(1)">
      <text>The service drop;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Service entrance conductors, cables, and raceways;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Service equipment and main disconnects;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Service grounding;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>System bonding;</text>
    </paragraph>
    <paragraph num="(6)">
      <text>Interior components of service panels and distribution panels;</text>
    </paragraph>
    <paragraph num="(7)">
      <text>Conductors;</text>
    </paragraph>
    <paragraph num="(8)">
      <text>Overcurrent protection devices;</text>
    </paragraph>
    <paragraph num="(9)">
      <text>A representative number of installed lighting fixtures, switches, and receptacles;</text>
    </paragraph>
    <paragraph num="(10)">
      <text>Ground fault and arc fault circuit interrupters; and</text>
    </paragraph>
    <paragraph num="(11)">
      <text>The general condition of visible branch circuit conductors that may constitute a hazard to the occupant or the structure by reason of improper use or installation of electrical components.</text>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>A home inspector shall describe the type and materials of the electrical system, including the:</text>
    <paragraph num="(1)">
      <text>Amperage and voltage rating of the service;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Location of:</text>
      <paragraph num="(a)">
        <text>Main disconnect;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Service equipment;</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Distribution panels; and</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>Wiring methods.</text>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>If applicable, a home inspector shall describe the:</text>
    <paragraph num="(1)">
      <text>Presence of solid conductor aluminum branch circuit wiring;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Presence or absence of:</text>
      <paragraph num="(a)">
        <text>Smoke alarms; or</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Carbon monoxide alarms; and</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>Presence of:</text>
      <paragraph num="(a)">
        <text>Non-arc-resistant CSST gas piping with the recommendation that the bonding of the CSST be reviewed by a licensed master electrician; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Alternative energy systems, including disconnect locations.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>A home inspector is not required to:</text>
    <paragraph num="(1)">
      <text>Inspect:</text>
      <paragraph num="(a)">
        <text>Remote control devices, unless the device is the only control device;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Alarm systems and components;</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Low voltage wiring systems and components;</text>
      </paragraph>
      <paragraph num="(d)">
        <text>Ancillary wiring, systems, and components that are not a part of the primary electrical power distribution system; or</text>
      </paragraph>
      <paragraph num="(e)">
        <text>the existing bonding method for CSST; or</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>Measure amperage, voltage, or impedance.</text>
    </paragraph>
  </paragraph>
</regulation>