Regulation .18 Control of Sanitary Facilities.

Regulation .18 Control of Sanitary Facilities.Copy Citation

The person-in-charge shall ensure that:
A.
Potable water is:
(1)
Obtained from a water supply system that complies with Environment Article, Title 9, Annotated Code of Maryland, and COMAR 26.04.04; and
(2)
Meets the standards of quality specified in Environment Article, Title 9, Annotated Code of Maryland, and COMAR 26.04.01;
B.
Non-potable water for non-culinary purposes such as air conditioning or fire protection is used only if the system complies with §H(3) of this regulation;
C.
Except for a temporary food service facility where water under pressure is not available, hot and cold running water under pressure is provided:
(1)
In all areas where:
(a)
Food is prepared; and
(b)
Equipment and utensils are washed; and
(2)
With sufficient water capacity, pressure, and hot water generation and distribution to meet peak demands throughout the facility;
D.
Drinking water, if not dispensed through the water supply system of the food service facility, is potable and stored in a container that meets all applicable laws, ordinances, and regulations;
E.
Steam that contacts food is free from deleterious or harmful matter that might adulterate food;
F.
All water-carried sewage is disposed of by:
(1)
A public sewerage system; or
(2)
An approved sewage disposal system constructed and operated in conformance with applicable State and local laws, ordinances, and regulations;
G.
Where water-carried disposal methods are not possible, non-water-carried sewage disposal facilities are utilized if:
(1)
The method has been approved by the approving authority as meeting State and local requirements; and
(2)
The facilities are:
(a)
In conformance with applicable State and local laws, ordinances, and regulations; and
(b)
Located outside and not attached to the establishment;
H.
Plumbing is sized, installed, and maintained so that:
(1)
The plumbing complies with applicable State and local plumbing laws, ordinances, and regulations;
(2)
The potable water supply system is:
(a)
Installed in a manner that prevents backflow or backsiphonage; and
(b)
Not connected with a non-potable water system in a manner that would allow non-potable water to be drawn or discharged into the potable water supply system;
(3)
The piping of a non-potable water system is:
(a)
Marked so that the piping is readily distinguishable from piping that carries potable water, such as with distinctive yellow-colored paint; and
(b)
Not connected to equipment or other outlets in the food preparation area;
(4)
Indirect waste piping is provided to a:
(a)
Food preparation or utensil washing sink;
(b)
Refrigerator coil;
(c)
Ice making machine;
(d)
Steam kettle;
(e)
Coffee urn or brewer;
(f)
Hot or cold drink machine;
(g)
Steam table;
(h)
Potato peeler;
(i)
Warewashing machine, unless:
(i)
The machine is located within 5 feet of a trapped floor drain; and
(ii)
The waste piping is connected directly to the inlet side of a floor drain trap vented in conformance with applicable State and local laws, ordinances, and regulations; and
(j)
Similar piece of equipment in which food, portable equipment, or utensils are placed;
(5)
Each compartment of a multiple compartment sink is indirectly drained to a trapped and vented plumbing receptor through an air gap that complies with State and local laws, regulations, and ordinances:
(a)
From a separate pipe through the air gap and into the plumbing receptor; or
(b)
Through the air gap into a single manifolded branch and into the plumbing receptor;
(6)
Plumbing receptors receiving the discharge of indirect waste pipes:
(a)
Have a shape and capacity that will prevent splashing or flooding; and
(b)
Are accessible for cleaning and inspection;
(7)
Food waste grinders are connected and trapped separately from other fixtures or sink compartments;
(8)
Floor drains subject to evaporation have:
(a)
A water seal of at least 4 inches;
(b)
Water fed from a plumbing fixture that complies with State and local laws, regulations, and ordinances; or
(c)
An automatic priming device that complies with State and local laws, regulations, and ordinances;
(9)
Floor drains in storerooms, refrigerated rooms, walk-in coolers, or other locations where food is stored, have indirect waste piping;
(10)
Hand sinks in food preparation tables and counters discharge through an air gap into a floor sink or receptor that is trapped and vented; and
(11)
Except when required by building design, waste pipes and fixtures are:
(a)
Not located over food storage, preparation, or serving areas; and
(b)
Where installed over food storage, preparation, or serving areas, food is protected by one or more of the following:
(i)
Pipe joining methods that will preclude leakage;
(ii)
Using wall-mounted fixtures;
(iii)
Limiting the number of pipe joints;
(iv)
Pressure testing the piping;
(v)
Thermally insulating pipes to prevent condensation; and
(vi)
Installing integral seepage pans or pipe sleeves;
I.
Toilet facilities are:
(1)
Sufficient in number to serve the facility;
(2)
Conveniently located;
(3)
Accessible to employees at all times;
(4)
Except as specified in Health-General Article, §21-325(b), Annotated Code of Maryland, for facilities established after January 1, 1979, provided for patrons whenever a food service facility:
(a)
Prepares food and provides seating; or
(b)
Is a carry-out facility with indoor tables used for dining;
(5)
Installed in accordance with applicable State and local laws, ordinances, and regulations;
(6)
Designed with fixtures that are:
(a)
Of sanitary design; and
(b)
Readily cleanable;
(7)
Kept:
(a)
Clean;
(b)
In good repair; and
(c)
Free of objectionable odor; and
(8)
Supplied with:
(a)
Toilet tissue at each toilet at all times; and
(b)
Receptacles that are easily cleanable and covered for waste materials in toilet rooms for women;
J.
Toilet rooms:
(1)
Are completely enclosed;
(2)
Are equipped with self-closing doors except when a toilet room without doors is approved by the approving authority based on a review that shows that:
(a)
Doors would impede the use of the toilet room; and
(b)
The requirements in §J(3)—(6) of this regulation are met;
(3)
Provide privacy;
(4)
Are provided mechanical ventilation that:
(a)
Exhausts air at the rate of 2 cubic feet per minute per square foot of floor area; and
(b)
Allows the entrance of an equal amount of makeup air;
(5)
Prevent the entry of insects and vermin; and
(6)
Do not open directly into the kitchen or food preparation areas;
K.
Hand washing facilities are:
(1)
Located:
(a)
In each food preparation and processing area;
(b)
In each utensil washing area; and
(c)
Adjacent to all toilet rooms;
(2)
Accessible at all times;
(3)
Equipped with an adequate supply of hand-cleaning soap or detergent;
(4)
Equipped with a means of drying hands, such as:
(a)
Individual towels in dispensers; or
(b)
An effective hand-drying device;
(5)
Equipped with a waste receptacle; and
(6)
Kept clean and in good repair;
L.
Hand sinks are:
(1)
Installed in accordance with applicable State and local laws, ordinances, and regulations;
(2)
Able to discharge:
(a)
Hot and cold running water; or
(b)
Tempered running water at a temperature of at least 100°F through:
(i)
A mixing valve;
(ii)
A combination faucet; or
(iii)
Any slow closing or metering faucet that provides a flow of water for at least 15 seconds before the faucet has to be reactivated; and
M.
Utensil washing vats, food preparation sinks, or mop sinks are not used as hand sinks.