<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".16" citation="COMAR 10.17.01.16" title_num="10" subtitle_num="17" chapter_num="01" heading="Standards for Water Recreational Attractions.">
  <text>An owner shall ensure that:</text>
  <paragraph num="A.">
    <text>A water recreational attraction:</text>
    <paragraph num="(1)">
      <text>Is designed to eliminate or minimize safety hazards such as entrapment, slipping, abrasions, cuts, falls, trip hazards, impact injury, and drowning;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Is in compliance with applicable State and local codes and this chapter; and</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Has a communication system for use by supervisors, watchers, and lifeguards;</text>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>Plans for supervision, attendants, and lifeguards are submitted as part of the construction plans and include safety personnel at all potentially hazardous activity areas;</text>
  </paragraph>
  <paragraph num="C.">
    <text>A swimming pool slide is in conformance with the American National Standard for Public Swimming Pools and has:</text>
    <paragraph num="(1)">
      <text>Attachments that firmly anchor the swimming pool slide;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>At the end of the slide a minimum water depth of:</text>
      <paragraph num="(a)">
        <text>4 feet, or a water depth in conformance with the manufacturer's installation instructions, for a distance of 10 feet along the slide centerline for a swimming pool slide that does not slow an individual's entry into the water or that drops the individual into the water; or</text>
      </paragraph>
      <paragraph num="(b)">
        <text>6 inches, or a water depth in conformance with the manufacturer's installation instructions, for a swimming pool slide designed to slow an individual to a near stop at the end of the slide;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>A cushioned landing mat below the end of a swimming pool slide if there is a potential for impact or abrasion injury;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>A centerline distance from the end of a slide to a wall, lifeline, transition point, centerline from another slide, or obstruction that eliminates the potential for an individual using the slide to strike a wall, lifeline, transition point, an individual using another slide, or an obstruction;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>A minimum side distance of 4 feet from the centerline of a slide to a wall, lifeline, transition point, or obstruction;</text>
    </paragraph>
    <paragraph num="(6)">
      <text>A design that eliminates the potential for an individual to strike the pool deck or coping while traveling down the swimming pool slide;</text>
    </paragraph>
    <paragraph num="(7)">
      <text>A slide end that extends beyond the pool wall, deck, and coping; and</text>
    </paragraph>
    <paragraph num="(8)">
      <text>A minimum side distance of 12 feet between the centerline of a slide and a diving board, diving platform, or starting block;</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>A water slide:</text>
    <paragraph num="(1)">
      <text>Complies with the conditions set forth at COMAR 09.12.63 as evidenced by written documentation from:</text>
      <paragraph num="(a)">
        <text>The Maryland Department of Labor; or</text>
      </paragraph>
      <paragraph num="(b)">
        <text>If the water slide is not subject to regulation by the Maryland Department of Labor, a registered professional engineer who certifies that the water slide meets the design criteria set forth at COMAR 09.12.63.07; and</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>Exits to a plunge pool or slide runout;</text>
    </paragraph>
  </paragraph>
  <paragraph num="E.">
    <text>A wave pool is provided with an emergency shut-off switch at each guard station;</text>
  </paragraph>
  <paragraph num="F.">
    <text>A tube ride has designated entry and exit points;</text>
  </paragraph>
  <paragraph num="G.">
    <text>A spray pool has:</text>
    <paragraph num="(1)">
      <text>A bottom that slopes from 1/4 inch per foot to 5/8 inch per foot to a drain with grate;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>No standing water; and</text>
    </paragraph>
    <paragraph num="(3)">
      <text>No obstruction less than 4 feet in height;</text>
    </paragraph>
  </paragraph>
  <paragraph num="H.">
    <text>A single-lane pool used for swimming laps has:</text>
    <paragraph num="(1)">
      <text>A minimum width of 7 1/2 feet; and</text>
    </paragraph>
    <paragraph num="(2)">
      <text>A sign on the deck that reads, “Warning: No Diving—Shallow Water” if the water depth is 5 feet or less;</text>
    </paragraph>
  </paragraph>
  <paragraph num="I.">
    <text>A decorative fountain or waterfall installed in or connected to a pool or spa does not create a health or safety hazard;</text>
  </paragraph>
  <paragraph num="J.">
    <text>A spray fixture, fountain, piece of play equipment, bridge, ramp, stair, float, swing, or other recreational equipment located within a pool or spa:</text>
    <paragraph num="(1)">
      <text>Is designed to eliminate or minimize safety hazards such as entrapment, concealment, slipping, abrasions, cuts, punctures, falls, trip hazards, impact injury, and drowning;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Is limited to a shallow water area;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Has a color that contrasts with the pool or spa so that the structure is highly visible;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Has pipes or support columns that are at least 6 inches in diameter;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>Is provided with an overhead clearance of at least 7 feet from the pool floor and 4 feet from the water surface where a person may walk under the fixture;</text>
    </paragraph>
    <paragraph num="(6)">
      <text>Is provided with recirculated, treated pool water for a spray, stream, or other flow of water; and</text>
    </paragraph>
    <paragraph num="(7)">
      <text>Is installed according to the manufacturer's directions;</text>
    </paragraph>
  </paragraph>
  <paragraph num="K.">
    <text>The water surface is maintained at a level that allows the surface overflow system to operate properly;</text>
  </paragraph>
  <paragraph num="L.">
    <text>At least two interconnected main drains are installed in the deepest part of a pool and are connected to the filtration system;</text>
  </paragraph>
  <paragraph num="M.">
    <text>A pump reservoir or surge tank is provided for a slide or water feature circulation pump intake and:</text>
    <paragraph num="(1)">
      <text>Is made of concrete or other impervious material with a smooth slip-resistant finish;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Has inlets through a weir or a gravity-fed drain with a secure grate;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Has a volume equal to 2 minutes of the combined flow of all pumps connected to the reservoir or tank;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Is accessible only to authorized individuals;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>Has pump intakes located in the pump reservoir that are designed to allow cleaning without danger of entrapment; and</text>
    </paragraph>
    <paragraph num="(6)">
      <text>The water velocity through grate or drain openings does not exceed 2 feet per second;</text>
    </paragraph>
  </paragraph>
  <paragraph num="N.">
    <text>A slide or water feature circulation pump has a check valve on the discharge side; and</text>
  </paragraph>
  <paragraph num="O.">
    <text>Returns from a filtration system are placed to provide even and positive circulation and to eliminate any dead spots.</text>
  </paragraph>
</regulation>