<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".29" citation="COMAR 10.17.01.29" title_num="10" subtitle_num="17" chapter_num="01" heading="Chemical Storage Area.">
  <text>An owner shall ensure that a recreational pool, semipublic pool, or public spa has a chemical storage area that:</text>
  <paragraph num="A.">
    <text>Is protected against the weather, excess heat, and moisture; and</text>
  </paragraph>
  <paragraph num="B.">
    <text>Has:</text>
    <paragraph num="(1)">
      <text>A lockable door which can be opened from the inside;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Ventilation that is sized at 2 cfm per square foot of floor area and that exhausts to the open air;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>A minimum of 20 footcandles of illumination; and</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Storage for chemicals in accordance with the material safety data sheet for a particular chemical.</text>
    </paragraph>
  </paragraph>
</regulation>