<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".06" citation="COMAR 10.21.30.06" title_num="10" subtitle_num="21" chapter_num="30" heading="Technical Requirements.">
  <text>A provider of TMH health services shall have video technology components as follows:</text>
  <paragraph num="A.">
    <text>A minimum bandwidth of 384 KBPS (H.263), 256 KBPS (H.264), or technical equivalent;</text>
  </paragraph>
  <paragraph num="B.">
    <text>A monitor with a:</text>
    <paragraph num="(1)">
      <text>Minimum net display of 16" diagonally; and</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Non-anamorphic video picture display;</text>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>A minimum video resolution of 1 Common Intermediate Format (CIF), or 1 Source Input Format (SIF);</text>
  </paragraph>
  <paragraph num="D.">
    <text>Internet protocol sessions that are encrypted unless they are conducted entirely on a protected network, or using a virtual private network connection; and</text>
  </paragraph>
  <paragraph num="E.">
    <text>A camera at the originating site, that has pan, tilt, and zoom capabilities that can be remotely controlled from the distant site.</text>
  </paragraph>
</regulation>