<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".33" citation="COMAR 11.19.02.33" title_num="11" subtitle_num="19" chapter_num="02" heading="Step-Well Service Door.">
  <paragraph num="A.">
    <text>The step risers shall be approximately equal in height with the upper riser not more than 15 inches in height.</text>
  </paragraph>
  <paragraph num="B.">
    <text>The surface of steps shall be completely covered with a nonskid material having 1-1/2 inch white nosing, fire-resistant, nonskid wear-resistant, and rubber step treads, which shall have a minimum overall thickness of 0.1875 inch.</text>
  </paragraph>
  <paragraph num="C.">
    <text>The steps shall be enclosed to prevent accumulation of ice and snow and may not protrude beyond the width of the body.</text>
  </paragraph>
  <paragraph num="D.">
    <text>The step well shall be illuminated by at least one lamp providing white light actuated automatically by the opening of the door.</text>
  </paragraph>
  <paragraph num="E.">
    <text>The lower step shall be not less than 12 inches and not more than 16 inches above the level on which the unloaded bus rests.</text>
  </paragraph>
</regulation>