<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".03" citation="COMAR 20.50.01.03" title_num="20" subtitle_num="50" chapter_num="01" heading="Definitions.">
  <paragraph num="A.">
    <text>In this subtitle, the following terms have the meanings indicated.</text>
  </paragraph>
  <paragraph num="B.">
    <text>Terms Defined.</text>
    <paragraph num="(1)">
      <text>“Abandoned call” means a telephone call in which the customer has elected to speak to a customer service representative but the call is terminated before the customer service representative answers.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>“All-in vegetation management cost” means all vegetation management capital and operation and maintenance expenditures, including:</text>
      <paragraph num="(a)">
        <text>All direct contractual costs and internal staffing associated with yearly scheduled cyclical trimming and all corrective work; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>All indirect costs associated with vegetation management staff, supplies, and equipment.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>Answer.</text>
      <paragraph num="(a)">
        <text>“Answer” means rendering assistance to a telephone caller or accepting information necessary to process a telephone call by a customer service representative or an automated voice response system.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>“Answer” does not include an acknowledgement that a telephone caller is waiting on the line.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>“Baseline annual usage” means:</text>
      <paragraph num="(a)">
        <text>The total of an eligible customer-generator’s previous 12 months of electric energy use in kilowatt hours at the time of the installation or upgrade of an eligible customer-generator’s generating system; or</text>
      </paragraph>
      <paragraph num="(b)">
        <text>An estimate of 12 months electric use in kilowatt hours based on a methodology approved by the Commission for an eligible customer-generator that does not have 12 months of electric energy use in kilowatt hours at the time of the installation or upgrade of an eligible customer-generator’s generating system.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(5)">
      <text>“Billing period” means the period of time covered by a bill issued by an electric company.</text>
    </paragraph>
    <paragraph num="(6)">
      <text>“Bordering jurisdiction” means the District of Columbia, Delaware, Pennsylvania, Virginia, and West Virginia.</text>
    </paragraph>
    <paragraph num="(7)">
      <text>“Commission” means the Public Service Commission of Maryland.</text>
    </paragraph>
    <paragraph num="(8)">
      <text>“Contact voltage” means a voltage condition that may result in an object or surface being inadvertently energized.</text>
    </paragraph>
    <paragraph num="(9)">
      <text>“Contact voltage risk zone (CVRZ)” means the portions of each electric company’s service territory that:</text>
      <paragraph num="(a)">
        <text>Are served by an underground electric distribution plant; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Have substantial pedestrian traffic or population density, whether permanent, seasonal or varying by time of day.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(10)">
      <text>“Contact voltage survey” means a survey performed by an electric company to detect contact voltage consistent with the company’s Commission-approved voltage survey plan.</text>
    </paragraph>
    <paragraph num="(11)">
      <text>“Corrective maintenance” means maintenance performed to correct system equipment or component conditions that render them incapable of performing their designed function.</text>
    </paragraph>
    <paragraph num="(12)">
      <text>“Critical facilities” means a utility-specific list of electric system customers essential for public health and safety requiring restoration priority as determined in consultation with State and local jurisdictions.</text>
    </paragraph>
    <paragraph num="(13)">
      <text>“Cultural control practices” means control of vegetation through the establishment of compatible stable plant communities or the use of crops, pastures, mulching, or other managed landscapes.</text>
    </paragraph>
    <paragraph num="(14)">
      <text>“Customer” means a person, partnership, association, corporation, or governmental agency being supplied with electric service by a utility.</text>
    </paragraph>
    <paragraph num="(15)">
      <text>“Customer average interruption duration index (CAIDI)” means the system average interruption duration index (SAIDI) divided by the system average interruption frequency index (SAIFI).</text>
    </paragraph>
    <paragraph num="(16)">
      <text>“Customers experiencing multiple interruptions (CEMIn)” means the ratio of individual customers experiencing n or more sustained interruptions to the total number of customers served.</text>
    </paragraph>
    <paragraph num="(17)">
      <text>“Customer interruption hours” means an amount of time calculated by multiplying a sustained interruption duration by the total number of customers affected by the sustained interruption.</text>
    </paragraph>
    <paragraph num="(18)">
      <text>“Distribution transformer” has the meaning stated in 10 CFR §431.192, as amended, which is incorporated by reference.</text>
    </paragraph>
    <paragraph num="(19)">
      <text>“Electric company” has the meaning stated in Public Utilities Article, §1-101, Annotated Code of Maryland.</text>
    </paragraph>
    <paragraph num="(20)">
      <text>“Electric distribution” plant means all electric company plant used to distribute electricity to its customers, including covers and protective structures and excluding customer meters and meter enclosures.</text>
    </paragraph>
    <paragraph num="(21)">
      <text>“Electric plant” means a plant and property owned by an electric utility, used in its business operations of providing electric service to its customers.</text>
    </paragraph>
    <paragraph num="(22)">
      <text>“Eligible customer-generator” has the meaning stated in Public Utilities Article, §7-306, Annotated Code of Maryland.</text>
    </paragraph>
    <paragraph num="(23)">
      <text>Environmental surcharge means the charge in dollars and cents billed by an electric company under Public Utilities Article, §7-203, Annotated Code of Maryland.</text>
    </paragraph>
    <paragraph num="(24)">
      <text>“Excess generation” means the amount of electricity produced by an eligible customer-generator that exceeds the electricity used by the eligible customer-generator in a monthly billing period.</text>
    </paragraph>
    <paragraph num="(25)">
      <text>“Feeder” means an electric plant that emanates from a substation, serves customers, and is normally electrically isolated at all endpoints.</text>
    </paragraph>
    <paragraph num="(26)">
      <text>“Global ETR” means a single estimated time for restoration for the entire service territory or the area of the service territory affected by the major outage event and should represent the time when at least 90 percent of all affected customers will have been restored.</text>
    </paragraph>
    <paragraph num="(27)">
      <text>“Government emergency responder” means fire and police personnel and government employees who:</text>
      <paragraph num="(a)">
        <text>Are working at the direction of fire, police, or 911 emergency dispatcher personnel to respond to an emergency; or</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Have been identified by fire, police, or 911 dispatcher personnel as responding to an emergency.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(28)">
      <text>“Hazard tree” means a structurally unsound tree or tree limb that could strike poles, substations, or energized overhead electric plant when it falls.</text>
    </paragraph>
    <paragraph num="(29)">
      <text>“Institute of Electrical and Electronics Engineers (IEEE) major event day” means a day determined to be a major event day using the IEEE method of determining excludable data for calculation of reliability indices under IEEE Std 1366TM  2003.</text>
    </paragraph>
    <paragraph num="(30)">
      <text>“Interruption duration” means the period of time, truncated or rounded to the nearest minute, during which a sustained interruption occurs.</text>
    </paragraph>
    <paragraph num="(31)">
      <text>“Maintenance” means an inspection, diagnostics test, and or physical maintenance performed with the intent of assessing or predicting equipment failure before it occurs or improving equipment condition and thus preventing an equipment component or sub-component performance failure.</text>
    </paragraph>
    <paragraph num="(32)">
      <text>“Major outage event” means an event when the following occurs:</text>
      <paragraph num="(a)">
        <text>Before January 1, 2020:</text>
        <paragraph num="(i)">
          <text>More than 10 percent or 100,000, whichever is less, of the electric utility’s Maryland customers experience a sustained interruption of electric service and restoration of electric service to any of these customers takes more than 24 hours; or</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>The federal, State, or local government declares an official state of emergency in the utility’s service territory and the emergency involves interruption of electric service; or</text>
        </paragraph>
      </paragraph>
      <paragraph num="(b)">
        <text>Beginning January 1, 2020:</text>
        <paragraph num="(i)">
          <text>More than 10 percent or 100,000, whichever is less, of the electric utility’s Maryland customers experience a sustained interruption of electric service; and</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Restoration of electric service to any of these customers takes more than 24 hours.</text>
        </paragraph>
      </paragraph>
    </paragraph>
    <paragraph num="(33)">
      <text>“Major outage event interruption data” means all electric customer interruption occurrence and duration information collected by the utility during a major outage event.</text>
    </paragraph>
    <paragraph num="(34)">
      <text>“Mature tree” means a tree, whether or not previously pruned by the utility, that is well-established with a defined crown and that is at least 20 feet tall or 6 inches in diameter at breast height. Mature tree does not include a hazard tree.</text>
    </paragraph>
    <paragraph num="(35)">
      <text>“Meter” means unless otherwise qualified, a device of the utility used in measuring watts, watt-hours, vars, var-hours, volt-amperes, or volt-ampere-hours.</text>
    </paragraph>
    <paragraph num="(36)">
      <text>“Micro combined heat and power” has the meaning stated in Public Utilities Article, §7-306, Annotated Code of Maryland.</text>
    </paragraph>
    <paragraph num="(37)">
      <text>“Momentary average interruption frequency index (MAIFIE)” means the ratio of the total number of customer momentary interruption events divided by the total number of customers served.</text>
    </paragraph>
    <paragraph num="(38)">
      <text>Momentary Interruption.</text>
      <paragraph num="(a)">
        <text>“Momentary interruption” means the loss of electric service of a duration limited to the time required to restore electric service by:</text>
        <paragraph num="(i)">
          <text>Automatic or supervisory-controlled switching operations; or</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Manual switching at locations where an operator is immediately available.</text>
        </paragraph>
      </paragraph>
      <paragraph num="(b)">
        <text>“Momentary interruption” does not include a loss of electric service which takes more than 5 minutes to restore.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(39)">
      <text>“Net energy metering” has the meaning stated in Public Utilities Article, §7-306, Annotated Code of Maryland.</text>
    </paragraph>
    <paragraph num="(40)">
      <text>“Net Excess Generation” has the meaning stated in Public Utilities Article, §7-306, Annotated Code of Maryland.</text>
    </paragraph>
    <paragraph num="(41)">
      <text>“Normal conditions” means conditions other than a major outage event.</text>
    </paragraph>
    <paragraph num="(42)">
      <text>“Number of customer interruptions” means the number of customers without electric service during a sustained interruption.</text>
    </paragraph>
    <paragraph num="(43)">
      <text>“Off right-of-way tree” means a tree or part of a tree where the utility does not typically perform routine tree trimming maintenance and may not have the rights to perform tree trimming to improve electric service reliability.</text>
    </paragraph>
    <paragraph num="(44)">
      <text>“On right-of-way tree” means a tree or part of a tree where the utility typically performs routine tree trimming maintenance and may or may not have the rights to perform tree trimming to improve electric service reliability.</text>
    </paragraph>
    <paragraph num="(45)">
      <text>“Operating district” means a distinct geographic area for which a cooperatively owned electric utility provides customer services from a decentralized office.</text>
    </paragraph>
    <paragraph num="(46)">
      <text>Outside Assistance.</text>
      <paragraph num="(a)">
        <text>“Outside assistance” means resources not routinely used by a utility for service restoration.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>“Outside assistance” does not include resources transferred among utility operating areas.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(47)">
      <text>“PJM” has the meaning stated in COMAR 20.52.01.02B.</text>
    </paragraph>
    <paragraph num="(48)">
      <text>“Premises” means a tract of land or real estate, including buildings and other appurtenances on it.</text>
    </paragraph>
    <paragraph num="(49)">
      <text>“Primary distribution system” means the alternating current distribution lines supplying the primaries of distribution transformers.</text>
    </paragraph>
    <paragraph num="(50)">
      <text>“Protective devices” means substation breakers and reclosers, line reclosers, line sectionalizing equipment, and line fuses.</text>
    </paragraph>
    <paragraph num="(51)">
      <text>“Resilience plan” means a plan or plans to prepare for and recover from pandemics, physical attacks, cyber attacks, electric supply shortages, weather events, significant infrastructure failures, and other credible disturbances with the potential to lead to large and widespread electric outages or loss of critical facilities essential for public health and safety.</text>
    </paragraph>
    <paragraph num="(52)">
      <text>“Secondary distribution system” means the alternating current system which connects the secondaries of distribution transformers to the customers' services.</text>
    </paragraph>
    <paragraph num="(53)">
      <text>“Sustained interruption” means the loss of electric service that is not classified as a momentary interruption.</text>
    </paragraph>
    <paragraph num="(54)">
      <text>“System average interruption duration index (SAIDI)” has the meaning stated in Public Utilities Article, §7-213(a)(2), Annotated Code of Maryland.</text>
    </paragraph>
    <paragraph num="(55)">
      <text>“System average interruption frequency index (SAIFI)” has the meaning stated in Public Utilities Article, §7-213(a)(3), Annotated Code of Maryland.</text>
    </paragraph>
    <paragraph num="(56)">
      <text>“Test current” means the current marked on the nameplate of a watt-hour meter by the manufacturer (identified as “TA” on meters manufactured since 1960). This is the current in amperes which is used as the base for adjusting and determining the accuracy of a watt-hour meter at heavy and light loads.</text>
    </paragraph>
    <paragraph num="(57)">
      <text>“Time-varying rate” means a base or commodity rate structure that includes more than one rate, each of which is applicable to a different time period during the billing cycle and excludes hourly priced rates for which the rate is derived from hourly energy costs from the PJM market.</text>
    </paragraph>
    <paragraph num="(58)">
      <text>“Total number of customers served” means the number of customers provided with electric service by the distribution facility on the last day of the time period for which a reliability index is being calculated.</text>
    </paragraph>
    <paragraph num="(59)">
      <text>“Utility” means an electric company as defined in Public Utilities Article, §1-101, Annotated Code of Maryland.</text>
    </paragraph>
    <paragraph num="(60)">
      <text>” Utility crew” means personnel and equipment routinely used by a utility for service restoration.</text>
    </paragraph>
    <paragraph num="(61)">
      <text>“Voltage survey plan” means an electric company plan approved by the Commission governing the electric company’s contact voltage detection and testing equipment and voltage detection and testing procedures to be used when conducting contact voltage surveys.</text>
    </paragraph>
    <paragraph num="(62)">
      <text>“Vulnerable individual” means a customer who is certified to the utility as having a serious illness or the need for life support pursuant to COMAR 20.31.03.01.</text>
    </paragraph>
    <paragraph num="(63)">
      <text>“Zonal ETR” means the estimated time for restoration when at least 90 percent of all affected customers in the sub-area will have been restored to service.</text>
    </paragraph>
  </paragraph>
</regulation>