  <regulation prefix="Regulation" num=".01" heading="Meter Shop.">
    <paragraph num="A.">
      <text>Meter Shop. Each utility shall maintain or designate a meter shop where meters may be inspected, tested, and repaired. The shop shall be open for inspection by authorized representatives of the Commission at all reasonable times, and the facilities and equipment, as well as the methods of making measurements and tests, shall be subject to the approval of the Commission.</text>
    </paragraph>
    <paragraph num="B.">
      <text>Accuracy of Test Equipment. The accuracy of the test equipment and of the test procedures shall be such that the overall error will not exceed 0.3 of 1 percent.</text>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".02" heading="Working Standards.">
    <paragraph num="A.">
      <text>Requirements. Each meter shop maintained or designated by a utility shall have at least one calibrated tank for volumetric measurement or a tank mounted upon scales for weight measurement. The tank shall be of sufficient capacity to insure an acceptable determination of the accuracy of the utilities' meters.</text>
    </paragraph>
    <paragraph num="B.">
      <text>Calibration. Working standards shall be checked periodically (see Regulation .09B of this chapter) by comparison with approved secondary standards.</text>
    </paragraph>
    <paragraph num="C.">
      <text>Certificates. Each standard shall be accompanied at all times by a certificate or calibration card, duly signed and dated, on which are recorded the corrections required to compensate for errors found at the customary test points at the time of the last previous test.</text>
    </paragraph>
    <paragraph num="D.">
      <text>Care in Handling. Extreme care shall be exercised in the use and handling of standards to assure that their accuracy is not disturbed.</text>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".03" heading="Test Procedures.">
    <paragraph num="A.">
      <text>Procedure. The following procedures shall apply to the testing and adjusting of meters and associated devices:</text>
      <paragraph num="(1)">
        <text>General. The test of any unit of metering equipment shall consist of a comparison of its accuracy with the accuracy of a standard.</text>
      </paragraph>
      <paragraph num="(2)">
        <text>Adjusted to Zero. All meters and associated devices, when tested, shall be adjusted as closely as practicable to the condition of zero error.</text>
      </paragraph>
      <paragraph num="(3)">
        <text>Use of Tolerances. All tolerances are to be interpreted as maximum permissible variations from the condition of zero error. In making adjustments, no advantage of the prescribed tolerance limits may be taken.</text>
      </paragraph>
    </paragraph>
    <paragraph num="B.">
      <text>Test Flows. For determination of minimum test flow and other normal test flows, the Commission will use as a guide the appropriate standard specifications of the American Water Works Association for the various types of meters. These flows for displacement type cold water meters are as follows:</text>
    </paragraph>
    <paragraph num="C.">
      <text>Tests to Determine Error in Registration. Meters shall be tested at the following three flows:</text>
      <paragraph num="(1)">
        <text>Minimum test flow;</text>
      </paragraph>
      <paragraph num="(2)">
        <text>Approximately 10 percent of the maximum normal flow;</text>
      </paragraph>
      <paragraph num="(3)">
        <text>Approximately 50 percent of the maximum normal flow, or at the maximum flow available at normal system pressure.</text>
      </paragraph>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".04" heading="Meter Registration.">
    <paragraph num="A.">
      <text>Pre-Installation Tolerances. A meter may not be placed in service if it registers less than 90 percent of the water passed through it at the minimum test flow or over-registers or under- registers more than 1-1/2 percent at the other test flows.</text>
    </paragraph>
    <paragraph num="B.">
      <text>Calculation of Error. The percentage by which the correct registration varies from the meter registration is derived by stopping the meter test hand at the starting point and then determining the percentage variation in registration as indicated by the working standard. The formula for determining the percentage error in registration is:</text>
    </paragraph>
    <paragraph num="C.">
      <text>Error in Registration for Billing Adjustments. The error in registration of a meter for billing adjustments shall be the algebraic average of the error in registration at the following two rates of flow:</text>
      <paragraph num="(1)">
        <text>Approximately 10 percent of maximum normal flow;</text>
      </paragraph>
      <paragraph num="(2)">
        <text>Approximately 50 percent of maximum normal flow, or at the maximum flow available at normal system pressure.</text>
      </paragraph>
    </paragraph>
    <paragraph num="D.">
      <text>Application of Error for Billing Adjustments. The meter error derived in §C, of this regulation, shall be used to calculate the correct consumption of water by applying the derived error in registration to the volume of water consumption indicated by the meter. If the meter is fast then the volume of water indicated by the meter registration shall be reduced by applying the calculated error in registration. If the meter is slow then the volume of water indicated by the meter registration shall be increased by applying the calculated error in registration.</text>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".05" heading="Pre-Installation Inspections and Tests.">
    <paragraph num="A.">
      <text>Approval. A meter may not be placed in service unless:</text>
      <paragraph num="(1)">
        <text>Its type and design first has been approved by the Commission;</text>
      </paragraph>
      <paragraph num="(2)">
        <text>It has been inspected and tested by the utility, or has been certified by the manufacturer to be correct;</text>
      </paragraph>
      <paragraph num="(3)">
        <text>Its registration is within the tolerances specified in Regulation .04A of this chapter; and</text>
      </paragraph>
      <paragraph num="(4)">
        <text>It has been sealed by the utility.</text>
      </paragraph>
    </paragraph>
    <paragraph num="B.">
      <text>Re-Installation. When any meter is removed from service it shall be repaired if necessary so that it conforms to the registration tolerances specified in Regulation .04A before being placed in service again.</text>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".06" heading="Request Tests.">
    <paragraph num="A.">
      <text>Request For Test. Upon request by a customer and at no charge, the utility shall make a test of the accuracy of registration of the meter serving the customer, provided that these tests need not be made more frequently than once in 24 months.</text>
    </paragraph>
    <paragraph num="B.">
      <text>Customer May Observe. The customer, or his representative, may be present when the meter is tested.</text>
    </paragraph>
    <paragraph num="C.">
      <text>Report to Customer. A report of the results of the test shall be made to the customer within a reasonable time after the completion of the test, and a record of the report, together with a complete record of the test, shall be kept on file at the office of the utility for at least 3 years.</text>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".07" heading="Referee Tests.">
    <paragraph num="A.">
      <text>Application For Test. Upon written application to the Commission by a customer or a utility, a test will be made of the customer's meter as soon as practicable by a representative of the Commission.</text>
    </paragraph>
    <paragraph num="B.">
      <text>Deposit For Test. The application shall be accompanied by a deposit as indicated: Water meter—$10.</text>
    </paragraph>
    <paragraph num="C.">
      <text>Notice to Utility. On receipt of a request from a customer the Commission will notify the utility and the utility may not knowingly remove or adjust the meter until instructed by the Commission. The utility shall furnish to the Commission's representative such reasonable assistance as may be required to make the test.</text>
    </paragraph>
    <paragraph num="D.">
      <text>Customer May Observe. The customer, or his representative, may be present when the meter is tested.</text>
    </paragraph>
    <paragraph num="E.">
      <text>Report to Customer. A written report of the results of the test will be sent to the customer and to the utility.</text>
    </paragraph>
    <paragraph num="F.">
      <text>Disposition of Deposit. If the meter is found to over-register more than 2 percent, calculated in accordance with Regulation .04C, the deposit shall be refunded by the Commission and the utility billed the amount of the deposit. Otherwise the deposit will be retained and disposed of according to law.</text>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".08" heading="As Found Tests.">
    <text>Each meter shall be tested before the meter is adjusted or repaired.</text>
  </regulation>
  <regulation prefix="Regulation" num=".09" heading="Periodic Tests.">
    <text>Each utility shall make periodic tests of meters and standards to assure their accuracy. These tests shall be scheduled within the calendar year, or earlier, when the interval is stated in years, or within the calendar month, or earlier, when the interval is stated in months. The basic periodic test interval may not be longer than provided for in the following schedule: (Note: Maintenance programs suggested by manufacturers of the following meters and devices should be carefully followed.)</text>
    <paragraph num="A.">
      <text>Meters.</text>
      <paragraph num="(1)">
        <text>5/8 in. ------------------------------10 years</text>
      </paragraph>
      <paragraph num="(2)">
        <text>3/4 in. ------------------------------ 8 years</text>
      </paragraph>
      <paragraph num="(3)">
        <text>1-in. -------------------------------- 6 years</text>
      </paragraph>
      <paragraph num="(4)">
        <text>1-1/2 in. and 2-in. ------------------4 years</text>
      </paragraph>
      <paragraph num="(5)">
        <text>3-in. and 4-in. ----------------------2 years</text>
      </paragraph>
      <paragraph num="(6)">
        <text>6-in. and larger --------------------12 months</text>
      </paragraph>
    </paragraph>
    <paragraph num="B.">
      <text>Working Standards.</text>
      <paragraph num="(1)">
        <text>Volumetric tank ---------------------- 5 years</text>
      </paragraph>
      <paragraph num="(2)">
        <text>Scales ------------------------------ 12 months</text>
      </paragraph>
    </paragraph>
  </regulation>
  <annotations>
    <annotation type="Authority">Public Utilities Article, §§2-121, 5-101, and 5-303, Annotated Code of Maryland</annotation>
    <annotation type="History" subtype="Administrative History">Effective date: July 1, 1968 (Order No. 57171)</annotation>
    <annotation type="History" subtype="Administrative History">Regulation .07B amended effective April 13, 1992 (19:7 Md. R. 747)</annotation>
    <annotation type="History" subtype="Administrative History">Regulation .08 amended effective May 14, 2001 (28:9 Md. R. 889)</annotation>
  </annotations>
</chapter>