<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".03" citation="COMAR 26.02.07.03" title_num="26" subtitle_num="02" chapter_num="07" heading="Methods of Abatement.">
  <paragraph num="A.">
    <text>A person performing abatement of lead-containing substances may not use the following methods:</text>
    <paragraph num="(1)">
      <text>Open flame burning;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Dry sanding, except as allowed in §B(2);</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Open abrasive blasting, except as allowed in §B(2);</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Uncontained hydro-blasting;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>Methylene chloride for interior use except that methylene chloride may be used in interior work areas for localized touch-up; or</text>
    </paragraph>
    <paragraph num="(6)">
      <text>Dry scraping; or</text>
    </paragraph>
    <paragraph num="(7)">
      <text>Heat gun operating at or above 1,100°F.</text>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>A person performing abatement of lead-containing substances shall only use the following methods:</text>
    <paragraph num="(1)">
      <text>Replacement. Any component part of a building may be abated by replacement with a part free of lead-containing substances.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Removal.</text>
      <paragraph num="(a)">
        <text>Unless replaced encapsulated, or reversed, woodwork and floors may only be abated by using the following techniques:</text>
        <paragraph num="(i)">
          <text>Offsite chemical stripping;</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Heat gun operating below 1,100°F;</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Non-flammable chemical strippers which do not contain methylene chloride, except that chemical strippers containing methylene chloride may be used for localized touch-up;</text>
        </paragraph>
        <paragraph num="(iv)">
          <text>Sander equipped with HEPA vacuum;</text>
        </paragraph>
        <paragraph num="(v)">
          <text>Vacuum-blasting in exterior work areas only; or</text>
        </paragraph>
        <paragraph num="(vi)">
          <text>Contained hydro-blasting in exterior work areas only.</text>
        </paragraph>
      </paragraph>
      <paragraph num="(b)">
        <text>Unless replaced or encapsulated, walls or ceilings may only be abated by using the following techniques:</text>
        <paragraph num="(i)">
          <text>Wet-scraping of loose material if scraping is followed by encapsulation;</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Vacuum-blasting in exterior work areas only; or</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Contained hydro-blasting in exterior work areas only.</text>
        </paragraph>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>Encapsulation.</text>
      <paragraph num="(a)">
        <text>A wall or ceiling surface may be abated by encapsulation using only the following materials:</text>
        <paragraph num="(i)">
          <text>Gypsum board;</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Fiberglass mats;</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Canvas backed vinyl wall coverings;</text>
        </paragraph>
        <paragraph num="(iv)">
          <text>Formica;</text>
        </paragraph>
        <paragraph num="(v)">
          <text>Tile;</text>
        </paragraph>
        <paragraph num="(vi)">
          <text>Paneling; or</text>
        </paragraph>
        <paragraph num="(vii)">
          <text>Other durable material that does not readily tear, chip, or peel.</text>
        </paragraph>
      </paragraph>
      <paragraph num="(b)">
        <text>A floor surface may be abated by encapsulation using only the following materials:</text>
        <paragraph num="(i)">
          <text>Tile;</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Vinyl flooring;</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Wood; or</text>
        </paragraph>
        <paragraph num="(iv)">
          <text>Stone.</text>
        </paragraph>
      </paragraph>
      <paragraph num="(c)">
        <text>A woodwork surface may be abated by encapsulation using only the following materials:</text>
        <paragraph num="(i)">
          <text>Plastic;</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Metal; or</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Wood.</text>
        </paragraph>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>Reversal. A woodwork surface may be abated by reversal of its component parts so long as no lead-containing surface remains exposed at the completion of the process, and all seams are caulked and sealed.</text>
    </paragraph>
    <paragraph num="(5)">
      <text>Windows Generally. Windows, when abated, shall be completely treated, including inside, outside and sides of sashes. Window frames shall be abated to the outside edge of the frame, including slides, sash guides and window wells.</text>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>Alternative Procedures.</text>
    <paragraph num="(1)">
      <text>The Department may, on a case-by-case basis, allow an alternative procedure for abatement of a lead paint hazard, provided that the owner or contractor who uses this procedure shall submit a written description of the alternative procedure to the Department which demonstrates to the satisfaction of the Department that the proposed alternative procedure provides the equivalent control and removal.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>In all cases in which the Department allows the use of an alternative procedure under §C(1), the owner and resident shall, for a 1-year period after completion of the lead abatement project, permit the Department to enter the area where the abatement occurred in order to inspect the property for the purpose of determining the effectiveness and durability of the allowed alternative procedure. Before conducting such an inspection the Department shall give written notice to the owner and resident of the property.</text>
    </paragraph>
  </paragraph>
</regulation>