<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".22" citation="COMAR 26.04.04.22" title_num="26" subtitle_num="04" chapter_num="04" heading="Construction Standards — Pumping Equipment.">
  <paragraph num="A.">
    <text>The selection and installation of the pumping equipment shall conform to COMAR 09.20, or the local plumbing code, whichever is more stringent.</text>
  </paragraph>
  <paragraph num="B.">
    <text>Electrical connections for pumping equipment shall conform to the National Electrical Code, or to the local electrical code, whichever is more stringent.</text>
  </paragraph>
  <paragraph num="C.">
    <text>If a safety rope is used it:</text>
    <paragraph num="(1)">
      <text>Shall be secured in the interior of the well; and</text>
    </paragraph>
    <paragraph num="(2)">
      <text>May not penetrate the well casing or cap.</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>If an electrical conduit is present at the well terminal, it shall:</text>
    <paragraph num="(1)">
      <text>Be secured to the well cap so as to prevent the entrance of vermin and debris;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Be plugged at the interior opening with caulk or other suitable material to provide a water-resistant and insect-resistant seal; and</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Extend at least 18 inches below the finished grade.</text>
    </paragraph>
  </paragraph>
  <paragraph num="E.">
    <text>Upon completion of pump installation, the person installing the pumping equipment shall disinfect the well, pump, and water supply system in accordance with this chapter.</text>
  </paragraph>
  <paragraph num="F.">
    <text>In areas of the State where the plumbing code does not specify pump installation requirements, then the pumping equipment shall be installed in accordance with the manufacturer's recommendations.</text>
  </paragraph>