<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".23" citation="COMAR 26.04.04.23" title_num="26" subtitle_num="04" chapter_num="04" heading="Construction Standards and Special Requirements for Specific Types of Wells.">
  <paragraph num="A.">
    <text>The following special requirements for specific types of wells based on the intended use of the well are as follows:</text>
    <paragraph num="(1)">
      <text>Irrigation Wells.</text>
      <paragraph num="(a)">
        <text>Wells in unconfined aquifers in Hydrogeologic Areas 1 and 2 used solely for irrigation shall have an annular space grouted to a minimum depth of 20 feet below land surface.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>All other irrigation wells shall meet the grouting requirements of Regulation .19 of this chapter.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>Monitoring Wells.</text>
      <paragraph num="(a)">
        <text>The well driller shall submit to the Approving Authority the construction specifications that are proposed for a monitoring well as an attachment to the permit application.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The Approving Authority may approve, as a special condition of a permit, special construction standards for wells installed for the purpose of monitoring ground water.</text>
      </paragraph>
      <paragraph num="(c)">
        <text>If the Approving Authority does not approve special construction standards, then well construction shall comply with the provisions of this chapter.</text>
      </paragraph>
      <paragraph num="(d)">
        <text>For an at-grade or below-grade well terminal, the well terminal shall be water tight and enclosed in a well vault.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>Injection Wells.</text>
      <paragraph num="(a)">
        <text>The well driller for an injection well shall submit to the Approving Authority the construction specifications that are proposed as an attachment to the permit application.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The Approving Authority may not issue a permit to construct an injection well unless a State Discharge Permit has been issued by the Department.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>Geothermal Wells — Closed Loop.</text>
      <paragraph num="(a)">
        <text>The pipe material, jointing, pressure testing, and anti-freeze solutions for a closed loop geothermal well shall conform to the standards of COMAR 09.15.05.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The anti-freeze solution shall be environmentally safe.</text>
      </paragraph>
      <paragraph num="(c)">
        <text>The borehole of a closed-loop geothermal well shall be grouted from the bottom of the borehole to the ground surface.</text>
      </paragraph>
      <paragraph num="(d)">
        <text>The upper terminal of a closed-loop geothermal well may terminate below grade if:</text>
        <paragraph num="(i)">
          <text>The well location is marked by a metal plate so that the location can be found by a metal detector; or</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>The manifold and horizontal lines are marked with detection tape.</text>
        </paragraph>
      </paragraph>
      <paragraph num="(e)">
        <text>When the closed-loop geothermal well is terminated below grade, the well tag shall be attached to the flow center.</text>
      </paragraph>
      <paragraph num="(f)">
        <text>If using copper as an exchange medium a maintenance agreement must be recorded in the County land records.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(5)">
      <text>Cathodic Protection Wells.</text>
      <paragraph num="(a)">
        <text>The borehole of a cathodic protection well shall be grouted from the bottom of the borehole to the ground surface.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The well driller shall submit to the Approving Authority the construction specifications that are proposed for a cathodic protection well as an attachment to the permit application.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(6)">
      <text>Dewatering Wells.  The annular space of a dewatering shall be grouted to a depth of 5 feet below the static water level.</text>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>The following specific construction standards for specific wells, based on construction method, are as follows:</text>
    <paragraph num="(1)">
      <text>Driven Wells.</text>
      <paragraph num="(a)">
        <text>Driven wells may not be used for a potable water supply.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>In a driven well an oversize hole for grout, at least 4 inches greater in diameter than the casing, shall be constructed to a depth of at least 10 feet, and the annular space between this hole and the casing shall be grouted to land surface.</text>
      </paragraph>
      <paragraph num="(c)">
        <text>The upper terminal of a driven well and pitless adapter or pitless unit installation shall be in accordance with this chapter.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>Bored, Augered, and Dug Wells Cased with Concrete Pipe.</text>
      <paragraph num="(a)">
        <text>Bored, augered, and dug wells shall have a borehole with a minimum diameter of 6 inches larger than the outside diameter of the casing.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The annular space shall be filled with grout to a depth of at least 30 feet below land surface, unless otherwise approved by the Approving Authority.</text>
      </paragraph>
      <paragraph num="(c)">
        <text>The annular space below the grout shall be filled with a sand or gravel pack.</text>
      </paragraph>
      <paragraph num="(d)">
        <text>Joints in the concrete casing shall be sealed with an impervious seal, such as cement and o-rings, to a depth of at least 20 feet.</text>
      </paragraph>
      <paragraph num="(e)">
        <text>The casing shall extend to a depth of at least 2 feet below the lowest seasonal water table.</text>
      </paragraph>
      <paragraph num="(f)">
        <text>The minimum depth of the casing shall be 20 feet.</text>
      </paragraph>
      <paragraph num="(g)">
        <text>The well shall be protected with either:</text>
        <paragraph num="(i)">
          <text>A precast, overlapping, steel-reinforced concrete cover; or</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>A metal cover at least 3/16 of an inch thick and fitted with a watertight gasket; and</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Be at least 8 inches above grade.</text>
        </paragraph>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>Jetted and Jetted-Driven Wells.</text>
      <paragraph num="(a)">
        <text>Jetted and jetted-driven wells shall be grouted to a minimum depth of 20 feet. This will necessitate construction of an oversize hole for grout to this depth.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Jetted and jetted-driven wells may not be used for potable water supplies.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>Horizontal Wells. The well driller shall submit plans with the Application for a Permit to Drill that provide details on how the horizontal well is to be constructed and identify the materials to be used.</text>
    </paragraph>
  </paragraph>
</regulation>