<subtitle num="10" heading="Oil Pollution Control and Storage Tank Management" title_num="26" title_heading="Department of the Environment">
  <chapter num="01" heading="Oil Pollution Control">
    <regulation prefix="Regulation" num=".01" heading="Scope and Applicability.">
      <paragraph num="A.">
        <text>Unless otherwise stated, throughout this subtitle when a regulation places a requirement on more than one person, the following apply:</text>
        <paragraph num="(1)">
          <text>The Department may hold all or each person individually liable for a violation;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At least one of the persons listed shall meet the requirement; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Each person listed shall ensure the requirement is met.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Except as otherwise provided, this chapter applies to a person that:</text>
        <paragraph num="(1)">
          <text>Engages in one or more of the following activities:</text>
          <paragraph num="(a)">
            <text>The aboveground or underground storage, dispensing, or transportation of oil;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The underground storage of a hazardous substance;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The removal, storage, treatment, or transportation of oil-contaminated soil, oil sludge, oil refuse, or oil mixed with other waste;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The installation, removal, closure, or maintenance of a storage tank system; or</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The management of used oil, including burning used oil as fuel;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Actively or passively participates in the spill, release, or discharge of oil or allows the spill, release, or discharge of oil; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Owns, operates, or is the person in charge of a device, equipment, facility, or vessel used to engage or participate in one or more of the activities described under §B(1) or (2) of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Exceptions.</text>
        <paragraph num="(1)">
          <text>Except for Regulations .02—.06 and .24 of this chapter, the requirements of this chapter do not apply to an owner, an operator, and a person in charge of a vessel, facility, or equipment when used in activities related to the removal of oil within a spill response area defined by a federal or State on-scene coordinator.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Except for Regulations .02—.04, and .24 of this chapter, the requirements of this chapter do not apply to an owner, an operator, and a person in charge of an underground storage tank (UST) system used for the storage of a hazardous substance.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Definitions.">
      <paragraph num="A.">
        <text>In this subtitle:</text>
        <paragraph num="(1)">
          <text>A term in §B of this regulation has the meaning indicated; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A term not defined in §B of this regulation has:</text>
          <paragraph num="(a)">
            <text>The meaning given to the term in a relevant statute; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If not defined in a relevant statute, the meaning attributed by common use.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>Aboveground Storage Tank (AST).</text>
          <paragraph num="(a)">
            <text>“Aboveground storage tank” means a storage tank that:</text>
            <paragraph num="(i)">
              <text>Currently stores oil;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Previously stored oil, except for a storage tank placed out-of-service to store a non-oil product in accordance with COMAR 26.10.17 or 26.10.18;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Has a storage capacity of greater than 250 gallons;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Is designed to operate at pressures from atmospheric pressure to a gauge pressure of 1.0 psi (6.9 kPa) measured at the top of the storage tank;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Is constructed more than 90 percent above the surface of the ground, excluding piping; and</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>May be installed in an underground vault, a basement, or a sub-surface building.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>“Aboveground storage tank” does not include:</text>
            <paragraph num="(i)">
              <text>An aboveground residential heating oil tank;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A storage tank on a farm or private residence with a capacity to store 1,100 gallons or less of motor fuel or heating oil for noncommercial or personal use;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A septic tank, surface impoundment, pit, pond, or lagoon;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>A stormwater or wastewater collection system;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>A flow-through process tank;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Oil-filled operational equipment;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>A pipeline facility, including gathering lines, regulated under 49 U.S.C. §§60101—60141, or an intrastate pipeline facility regulated under State law as provided under 49 U.S.C. §§60101—60141 and determined by the federal Secretary of Transportation to be connected to a pipeline, or operated or intended to be capable of operating at pipeline pressure or as an integral part of a pipeline; and</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>A liquid trap or associated gathering lines directly related to oil or gas production and gathering operations.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>“Aggregate storage capacity” means the total oil storage capacity of all ASTs on a property.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Ancillary Equipment.</text>
          <paragraph num="(a)">
            <text>“Ancillary equipment” means a device connected to a storage tank system used to distribute, meter, or control the flow of:</text>
            <paragraph num="(i)">
              <text>Oil to and from an AST; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A regulated substance to and from a UST, as defined in COMAR 26.10.02.02B.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>“Ancillary equipment” includes, but is not limited to, devices such as piping, fittings, flanges, valves, and pumps.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>“AST system” means an AST, connected aboveground and underground piping, ancillary equipment, and appurtenances, including dispensers, loading racks, and secondary containment.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>“Attended” means there is an attendant or an employee that is on duty and available to customers at a motor fuel dispensing facility.</text>
        </paragraph>
        <paragraph num="(6)">
          <text>“Barge” means a vessel not equipped with a means of self-propulsion.</text>
        </paragraph>
        <paragraph num="(7)">
          <text>“Barrel” means a measure of oil that consists of 42.0 gallons of liquid measure.</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Biofuel.</text>
          <paragraph num="(a)">
            <text>“Biofuel” means a fuel that is derived from animal or plant byproducts.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Biofuel” may include oil if the liquid meets the definition of oil under §B(47) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(9)">
          <text>“Breakout tank” means a tank used to:</text>
          <paragraph num="(a)">
            <text>Relieve surges in an oil pipeline system; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Receive and store oil transported by pipeline for reinjection and continued transportation by pipeline.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(10)">
          <text>“Cargo level monitor system” means a system of fixed level sensing and warning devices used to gauge and to warn of changes in levels of liquid cargo during transport by tank vessel, or any other system that gauges levels and warns of changes in levels of liquid cargo that is approved by the United States Coast Guard under 33 CFR Part 157.</text>
        </paragraph>
        <paragraph num="(11)">
          <text>Cargo Tank.</text>
          <paragraph num="(a)">
            <text>“Cargo tank” means any vehicle-mounted tank used for carrying oil that has a liquid capacity greater than 110 gallons.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Cargo tank” does not include a tank used solely for the purpose of supplying fuel for the propulsion of a vehicle.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(12)">
          <text>“Cathodic protection” means a technique to prevent corrosion of a metal surface by making that surface the cathode of an electrochemical cell, usually through the application of either galvanic anodes or impressed current.</text>
        </paragraph>
        <paragraph num="(13)">
          <text>“Cathodic protection tester” means a person who:</text>
          <paragraph num="(a)">
            <text>Can demonstrate an understanding of the principles and measurements of all common types of cathodic protection systems as applied to buried or submerged metal piping and storage tank systems;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Possesses one of the following:</text>
            <paragraph num="(i)">
              <text>A valid registration or certification card issued by a recognized institution within the past 5 years; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Documentation signed by a professional engineer (PE) attesting to the person’s education and knowledge of cathodic protection; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Possesses education and experience in soil resistivity, stray current, structure-to-soil potential, and component electrical isolation measurements of buried metal piping and storage tank systems.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(14)">
          <text>“Collecting agents” means a chemical agent or other compound that can gel, congeal, herd, entrap, fix, or make an oil mass more rigid or viscous to facilitate its removal from a water surface.</text>
        </paragraph>
        <paragraph num="(15)">
          <text>“Combustible liquid” means a liquid having a closed-cup flash point at or above 100.0ºF (37.8ºC).</text>
        </paragraph>
        <paragraph num="(16)">
          <text>Containment Sump.</text>
          <paragraph num="(a)">
            <text>“Containment sump” means a liquid-tight container that protects the environment by containing spills, releases, or discharges of a regulated substance from piping, dispensers, pumps and related components in the containment area.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Containment sump” may be single-walled or secondarily contained and located at the top of a storage tank (tank top or submersible turbine pump sump), underneath the dispenser (under-dispenser containment sump), or at other points in the piping run (transition or intermediate sump).</text>
          </paragraph>
        </paragraph>
        <paragraph num="(17)">
          <text>“Control” means the possession of power to direct or cause the direction of the actions of a person, place, or thing.</text>
        </paragraph>
        <paragraph num="(18)">
          <text>Corrosion Expert.</text>
          <paragraph num="(a)">
            <text>“Corrosion expert” means a person who, by reason of thorough knowledge of the physical sciences and the principles of engineering and mathematics acquired by a professional education and related practical experience, is qualified to engage in the practice of corrosion control on buried or submerged metal components of a storage tank system.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Corrosion expert” includes:</text>
            <paragraph num="(i)">
              <text>A person who is certified by the National Association of Corrosion Engineers; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A registered professional engineer who has certification or licensing that includes education and experience in corrosion control on buried or submerged metal components of storage tank systems.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(19)">
          <text>“Damages” has the meaning stated in Environment Article, §4-401(c), Annotated Code of Maryland.</text>
        </paragraph>
        <paragraph num="(20)">
          <text>“Department” means the Maryland Department of the Environment.</text>
        </paragraph>
        <paragraph num="(21)">
          <text>“Dielectric material” means a material, such as a coating, bushing, or union that does not conduct direct electrical current.</text>
        </paragraph>
        <paragraph num="(22)">
          <text>“Discharge” means the addition, introduction, leaking, spilling, or emitting of oil to waters of the State or the placement of oil in a location where it is likely to reach or pollute waters of the State.</text>
        </paragraph>
        <paragraph num="(23)">
          <text>“Dispenser” means equipment located aboveground that dispenses:</text>
          <paragraph num="(a)">
            <text>Oil from an AST system; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A regulated substance from a UST system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(24)">
          <text>Dispenser System.</text>
          <paragraph num="(a)">
            <text>“Dispenser system” means a dispenser and the equipment necessary to connect the dispenser to a UST system.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Dispenser system” includes a dispenser connected to a UST system using check valves, shear valves, unburied risers or flexible connectors, or other transitional components that are underneath the dispenser and connect the dispenser to the UST system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(25)">
          <text>“Dispersant” means a chemical agent or another compound that can emulsify, disperse, or solubilize oil or which acts to further the surface spreading of oil to facilitate its dispersal.</text>
        </paragraph>
        <paragraph num="(26)">
          <text>“Farm tank” means a storage tank:</text>
          <paragraph num="(a)">
            <text>That does not meet the definition of a residential heating oil tank under §B(65) of this regulation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Located on a farm property, including associated residences and improvements, or a tract of land devoted to:</text>
            <paragraph num="(i)">
              <text>Agriculture, including the production of crops and nurseries with growing operations; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Raising animals, including rangelands and fish hatcheries; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Used solely in farm activities.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(27)">
          <text>“Flammable liquid” means a liquid having a closed-cup flash point below 100.0ºF (37.8ºC).</text>
        </paragraph>
        <paragraph num="(28)">
          <text>“Floodplain” has the meaning stated in COMAR 26.17.04.02B.</text>
        </paragraph>
        <paragraph num="(29)">
          <text>Flow-through Process Tank.</text>
          <paragraph num="(a)">
            <text>“Flow-through process tank” means a tank that forms an integral part of a production process through which there is a steady, variable, recurring, or intermittent flow of materials during the operation of the process.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Flow-through process tank” does not include:</text>
            <paragraph num="(i)">
              <text>Oil-filled operational equipment or a tank used for the storage of materials before their introduction into the production process; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Oil-filled operational equipment or a tank used for the storage of finished products or byproducts from the production process.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(30)">
          <text>“Fuel oil” means a liquid petroleum product that includes, but is not limited to, the following products:</text>
          <paragraph num="(a)">
            <text>No. 1, No. 2, No. 4 – light, No. 4 – heavy, No. 5 – light, No. 5 – heavy, and No. 6 technical grades of fuel oil;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Other residual fuel oils, including Navy Special fuel oil and Bunker C;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Other fuels when used as substitutes for one of the fuel oils described in §B(30)(a) and (b) of this regulation; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Heating oil as defined under §B(35) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(31)">
          <text>“Fund” means the Maryland Oil Disaster Containment, Clean-Up and Contingency Fund.</text>
        </paragraph>
        <paragraph num="(32)">
          <text>“Gathering lines” means any pipeline, equipment, facility, or building used in the transportation of oil or gas during oil or gas production or gathering operations.</text>
        </paragraph>
        <paragraph num="(33)">
          <text>“General Oil Operations Permit” means the authorization established under Regulation .09B of this chapter for certain categories of oil storage facilities and oil handling facilities to operate without an Individual Oil Operations Permit.</text>
        </paragraph>
        <paragraph num="(34)">
          <text>Hazardous Substance.</text>
          <paragraph num="(a)">
            <text>“Hazardous substance” has the meaning stated in §101(14) of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980, 42 U.S.C. §9601(14).</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Hazardous substance” does not include a substance that is regulated as a hazardous waste under Subtitle C of the Resource Conservation and Recovery Act.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(35)">
          <text>“Heating oil” means a fuel oil as defined under §B(30) of this regulation that is typically used in the operation of heating equipment, boilers, or furnaces.</text>
        </paragraph>
        <paragraph num="(36)">
          <text>“Individual Oil Operations Permit” means an individual written authorization issued by the Department in accordance with Regulation .09A of this chapter describing the required performance standards for specific activities and operations of an oil storage facility or oil handling facility.</text>
        </paragraph>
        <paragraph num="(37)">
          <text>“Leak” means a loss of pressure within a storage tank system that may result in a spill, release, or discharge.</text>
        </paragraph>
        <paragraph num="(38)">
          <text>“Licensee” means a person who holds a valid Oil Transfer License from the Department in accordance with Regulation .08 of this chapter.</text>
        </paragraph>
        <paragraph num="(39)">
          <text>“Loading/unloading rack” means a fixed structure, such as a platform or gangway, having a loading or unloading arm necessary for loading or unloading a truck tank, transport, or tank car and may include any combination of the following:</text>
          <paragraph num="(a)">
            <text>Piping assemblages;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Valves;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Pumps;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Shut-off devices;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Overfill sensors; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Personnel safety devices.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(40)">
          <text>“Maintenance” means the performance of normal operational upkeep to prevent a storage tank system from spilling, releasing, or discharging a regulated substance.</text>
        </paragraph>
        <paragraph num="(41)">
          <text>Marina.</text>
          <paragraph num="(a)">
            <text>“Marina” means a facility having one or more piers, moorings or bulkheads, and marine motor fuel storage and dispensing systems for boats, vessels, and other marine watercraft used primarily for recreational purposes by the general public.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Marina” does not include a marine oil facility.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(42)">
          <text>Marine Oil Facility.</text>
          <paragraph num="(a)">
            <text>“Marine oil facility” means an on-shore or off-shore oil storage facility or oil handling facility located within waters of the State, including the Chesapeake Bay and its tributaries, used or capable of being used to transfer oil in bulk to or from a tank vessel and includes structures, equipment, and appurtenances.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Marine oil facility” includes, if the facility is associated with a factory or power plant, only areas of the facility used for transfer of oil to or from a tank vessel.</text>
          </paragraph>
          <paragraph num="(c)">
            <text>“Marine oil facility” does not include a tank vessel or a tank barge.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(43)">
          <text>“MDE” means the Maryland Department of the Environment.</text>
        </paragraph>
        <paragraph num="(44)">
          <text>“Monthly” means occurring at a frequency of once per calendar month and occurring generally 28 to 31 days between events.</text>
        </paragraph>
        <paragraph num="(45)">
          <text>Motor Fuel.</text>
          <paragraph num="(a)">
            <text>“Motor fuel” means a complex blend of hydrocarbons typically used in the operation of a motor engine or an emergency generator.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Motor fuel” includes:</text>
            <paragraph num="(i)">
              <text>Motor gasoline, including gasohol;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Aviation gasoline;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>No. 1 or No. 2 diesel fuel, including biodiesel fuel; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Any blend containing one or more of the substances listed in §B(45)(b)(i)—(iii) of this regulation.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(46)">
          <text>“Motor fuel dispensing facility” means that portion of an oil storage facility where motor fuels are stored and dispensed from fixed equipment into the fuel tanks of motor vehicles, vessels, or into approved containers, including all equipment used in connection therewith.</text>
        </paragraph>
        <paragraph num="(47)">
          <text>Oil.</text>
          <paragraph num="(a)">
            <text>“Oil” means oil of any kind and in any liquid form including:</text>
            <paragraph num="(i)">
              <text>Petroleum and petroleum products;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Petroleum byproducts;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Light and heavy fuel oils, including fuel oils that are blended or mixed with biofuels or processed or re-refined used oil;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Sludge containing oil or oil residues;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Oil refuse;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Oil mixed with or added to or otherwise contaminating soil, waste, or any other liquid or solid media;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>Crude oils;</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>Aviation fuels;</text>
            </paragraph>
            <paragraph num="(ix)">
              <text>Gasoline, including gasohol;</text>
            </paragraph>
            <paragraph num="(x)">
              <text>Kerosene;</text>
            </paragraph>
            <paragraph num="(xi)">
              <text>Diesel motor fuel, including biodiesel fuel, regardless of whether the fuel is petroleum based;</text>
            </paragraph>
            <paragraph num="(xii)">
              <text>Asphalt;</text>
            </paragraph>
            <paragraph num="(xiii)">
              <text>Ethanol that is intended to be used as a motor fuel or fuel source; and</text>
            </paragraph>
            <paragraph num="(xiv)">
              <text>Regardless of specific gravity, every other nonedible, nonsubstituted liquid petroleum fraction unless that fraction is specifically identified as a hazardous substance under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980, 42 U.S.C. §§9601 et seq.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>“Oil” does not include:</text>
            <paragraph num="(i)">
              <text>Liquefied propane;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Liquefied natural gas; or</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Any edible oils not intended to be used as a motor fuel or a fuel source.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(48)">
          <text>“Oil-filled operational equipment” means equipment that includes an oil storage container or multiple containers in which the oil is present solely to support the function of the apparatus or the device, including:</text>
          <paragraph num="(a)">
            <text>Hydraulic systems;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Lubricating systems for pumps, compressors and other rotating equipment;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Gear boxes;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Machining coolant systems;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Heat transfer systems;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Transformers;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Circuit breakers;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Electrical switches; and</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Other systems containing oil solely to enable the operation of the device.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(49)">
          <text>“Oil handling facility” means a facility that is responsible for one or more of the following operations:</text>
          <paragraph num="(a)">
            <text>Delivery of oil by cargo tank;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Transfer of oil;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Management of used oil;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Storage and treatment of oil-contaminated soils; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Oil sludge, oil refuse, or oil mixed with other waste solidification/stabilization.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(50)">
          <text>Oil Storage Facility.</text>
          <paragraph num="(a)">
            <text>“Oil storage facility” means an installation, structure, or premises, including an aboveground or underground storage tank, in which oil has been or is stored.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Oil storage facility” does not include:</text>
            <paragraph num="(i)">
              <text>A storage tank on a farm or private residence with a capacity to store 1,100 gallons or less of motor fuel or heating oil for noncommercial or personal use; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A vessel.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(51)">
          <text>“Operator” means a person in control of a storage tank system, oil storage facility, or oil handling facility or a person that has responsibility over the following activities for a storage tank system, oil storage facility, or oil handling facility:</text>
          <paragraph num="(a)">
            <text>Daily or periodic operation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Installation, repair, maintenance, and testing of one or more storage tank system; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Closure.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(52)">
          <text>“Other security” means a trust fund, letter of credit, insurance, or other form of financial responsibility approved by the Department.</text>
        </paragraph>
        <paragraph num="(53)">
          <text>“Owner” means a person who:</text>
          <paragraph num="(a)">
            <text>Owns a storage tank system, oil storage facility, or oil handling facility; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Owned a storage tank system, oil storage facility, or oil handling facility immediately before the discontinuation of its use.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(54)">
          <text>“Permittee” means one of the following regulated persons:</text>
          <paragraph num="(a)">
            <text>A person holding a valid Individual Oil Operations Permit issued by the Department;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A person subject to a General Oil Operations Permit authorized by the Department; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A person subject to a General UST System Permit authorized by the Department under COMAR 26.10.02.04.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(55)">
          <text>“Person” means:</text>
          <paragraph num="(a)">
            <text>An individual;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A receiver, trustee, guardian, executor, administrator, fiduciary, trust, or representative of any kind;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A partnership, firm, joint stock company, association, public or private corporation, joint venture, commercial entity, or consortium;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The United States Government and any federal agency;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The State or a county, municipality, municipal corporation, or other political subdivision of the State, or any of their units;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>A commission or any interstate body; or</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Any other entity.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(56)">
          <text>“Person in charge” means a person designated by an owner, an operator, or a permittee as the person with direct supervisory responsibility for:</text>
          <paragraph num="(a)">
            <text>An activity or operation at a facility, such as the transfer of oil to or from any points in the facility; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The repair, installation, maintenance, closure, or testing of a storage tank system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(57)">
          <text>“Person responsible for the discharge” means a person that meets the criteria under Environment Article, §4-401(j), Annotated Code of Maryland and includes the owner, the operator, or the person in charge of an oil handling facility involved in the discharge at the time of or immediately before the discharge.</text>
        </paragraph>
        <paragraph num="(58)">
          <text>“Pier” means a fixed or floating dock or a wharf constructed on or over waters of the State.</text>
        </paragraph>
        <paragraph num="(59)">
          <text>“Pollution” means every contamination or alteration of the physical, chemical, or biological properties of any waters of the State, including a change in temperature, taste, color, turbidity, or odor of the waters or the discharge or deposit of any organic matter, harmful organism, or liquid, gaseous, solid, radioactive, or other substance into any waters of the State that will render the waters harmful, detrimental, or injurious to:</text>
          <paragraph num="(a)">
            <text>Public health, safety, or welfare;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Domestic, commercial, industrial, agricultural, recreational, or other legitimate beneficial uses;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Livestock, wild animals, or birds; or</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Fish or other aquatic life.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(60)">
          <text>“Public vessel” means a vessel, not engaged in commerce, which is operated by the Government of the United States or a state or political subdivision or a foreign nation.</text>
        </paragraph>
        <paragraph num="(61)">
          <text>“Regulated substance” means:</text>
          <paragraph num="(a)">
            <text>A hazardous substance as defined under §B(34) of this regulation; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Oil as defined under §B(47) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(62)">
          <text>Regulated Substance Storage Facility.</text>
          <paragraph num="(a)">
            <text>“Regulated substance storage facility” means an installation, structure, or premises in which a regulated substance has been or is stored in one or more UST systems.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Regulated substance storage facility” includes an underground oil storage facility</text>
          </paragraph>
        </paragraph>
        <paragraph num="(63)">
          <text>“Release” means:</text>
          <paragraph num="(a)">
            <text>A discharge as defined under §B(22) of this regulation from a storage tank system, transport, truck tank, tank barge, tank car, or pipeline;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The discharge, escaping, leaching, spilling, leaking, emitting, or disposing of a regulated substance from a UST system as defined in COMAR 26.10.02.02B into:</text>
            <paragraph num="(i)">
              <text>Groundwater, surface water, or surface or subsurface soils; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Secondary containment; or</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>The discharge, escaping, leaching, spilling, leaking, emitting, or disposing of oil from an AST system to a secondary containment dike as defined in COMAR 26.10.17.02B and 26.10.18.02B.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(64)">
          <text>“Removal” means:</text>
          <paragraph num="(a)">
            <text>In response to a spill, release, or discharge, the act of abatement, containment, response, or the taking of other corrective actions as may be necessary to minimize or mitigate damage to the public health, safety, or welfare from a discharge or release or the threat of a discharge or release, including, but not limited to, public and private lands, waters of the State, and natural resources, both living and inert; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The act of extracting a UST, underground piping, and any other components of a UST system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(65)">
          <text>“Residential heating oil tank” means an aboveground or underground storage tank that is used to store heating oil for use as a fuel in heating a single-family residential property and that meets the criteria for a heating oil tank under Environment Article, §4-401, Annotated Code of Maryland.</text>
        </paragraph>
        <paragraph num="(66)">
          <text>“Residential tank” means a storage tank used solely for noncommercial purposes and serving not more than one residence.</text>
        </paragraph>
        <paragraph num="(67)">
          <text>“Responsible party” includes:</text>
          <paragraph num="(a)">
            <text>For a discharge of oil, the person responsible for the discharge; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>For a release of a regulated substance from a UST system:</text>
            <paragraph num="(i)">
              <text>The owner of the released regulated substance;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The owner, the operator, and the person in charge of the UST system or vehicle involved in the release of the regulated substance at the time of or immediately before the release;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Any other person who through act of omission causes the release; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>A person that meets the criteria of a responsible person under Environment Article, §7-201(t), Annotated Code of Maryland.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(68)">
          <text>“Secondary containment” means an Underwriters Laboratories LLC (UL) listed or Department-approved system that:</text>
          <paragraph num="(a)">
            <text>Prevents a release to the environment by containing a regulated substance released from the primary storage tank or piping until the regulated substance is detected and removed; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Detects a release by meeting the requirements of COMAR 26.10.05.05G.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(69)">
          <text>“Secretary” means the Secretary of the Environment or the Secretary’s designee.</text>
        </paragraph>
        <paragraph num="(70)">
          <text>“Sinking agent” means a chemical agent or other compound that can physically sink oil below the water surface.</text>
        </paragraph>
        <paragraph num="(71)">
          <text>“Solidification/stabilization” means a treatment process that involves combining oil sludge, oil refuse, or oil mixed with other waste with a non-hazardous substance to solidify or eliminate liquid traits of the oil sludge, oil refuse, or oil mixed with other waste.</text>
        </paragraph>
        <paragraph num="(72)">
          <text>“Sorbent” means a substance or material that takes up and holds oil by either adsorption or absorption.</text>
        </paragraph>
        <paragraph num="(73)">
          <text>“Special flood hazard area” or “area of special flood hazard” has the meaning stated in 44 CFR §59.1.</text>
        </paragraph>
        <paragraph num="(74)">
          <text>“Spill” means a release as defined in §B(63) of this regulation.</text>
        </paragraph>
        <paragraph num="(75)">
          <text>Spill Catchment Basin.</text>
          <paragraph num="(a)">
            <text>“Spill catchment basin” means a liquid tight container, which may be single-walled or double-walled, that has a minimum capacity of 5 gallons and is installed on the fill pipe riser, remote fill pipe, and Stage I vapor recovery connections.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Spill catchment basin” includes a spill bucket.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(76)">
          <text>“Spill Prevention, Control, and Countermeasure (SPCC) Plan” means the document required under 40 CFR §112.3 that details the equipment, workforce, procedures, and steps to prevent, control, and provide adequate countermeasures to a spill, release, or discharge.</text>
        </paragraph>
        <paragraph num="(77)">
          <text>“State” means the State of Maryland.</text>
        </paragraph>
        <paragraph num="(78)">
          <text>“Storage capacity” means the primary shell capacity of a storage tank.</text>
        </paragraph>
        <paragraph num="(79)">
          <text>“Storage tank” means a stationary device:</text>
          <paragraph num="(a)">
            <text>Designed to contain an accumulation of oil either aboveground or underground, or an accumulation of hazardous substances underground; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Constructed of nonearthen materials such as concrete, steel, fiberglass, and plastic, that provide structural support.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(80)">
          <text>“Storage tank system” means a storage tank, connected piping, ancillary equipment and appurtenances, including dispensers and secondary containment.</text>
        </paragraph>
        <paragraph num="(81)">
          <text>“Tank barge” means a tank vessel not equipped with a means of self-propulsion.</text>
        </paragraph>
        <paragraph num="(82)">
          <text>“Tank car” means a cargo tank that is moved by locomotive power along a railroad system.</text>
        </paragraph>
        <paragraph num="(83)">
          <text>Tank Vessel.</text>
          <paragraph num="(a)">
            <text>“Tank vessel” means a vessel constructed or adapted to carry oil, or that carries oil in bulk as cargo, in a quantity of 300 gallons or more and does not carry the oil for self-propulsion.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Tank vessel” does not include any vessel dedicated to, and engaged only in, oil removal-related activities, including training or drills.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(84)">
          <text>“Tank vessel operator” means a person responsible for the operation of a tank vessel and includes, but is not limited to, the owner or a person who charters the tank vessel by demise.</text>
        </paragraph>
        <paragraph num="(85)">
          <text>“Transfer” means the loading or unloading of oil in the State from or to any tank vessel, tank barge, transport, truck tank, tank car, pipeline, or any other means used for transporting oil.</text>
        </paragraph>
        <paragraph num="(86)">
          <text>“Transfer area” means an area of an oil storage facility or oil handling facility, other than a loading/unloading rack, where oil is transferred to or from a tank car.</text>
        </paragraph>
        <paragraph num="(87)">
          <text>“Transport” means a vehicle used for the transportation of oil and equipped with a cargo tank or vacuum tank having a fifth wheel connection such that part of its load and weight rests upon the towing vehicle.</text>
        </paragraph>
        <paragraph num="(88)">
          <text>“Transporting” means the movement of oil or storage of oil by tank vessel, transport, truck tank, tank barge, tank car, or pipeline, or any other means used for transporting oil, and includes the transfer of oil.</text>
        </paragraph>
        <paragraph num="(89)">
          <text>“Truck tank” means a self-propelled motor vehicle used for the transportation of oil and equipped with a permanently mounted cargo tank or vacuum tank.</text>
        </paragraph>
        <paragraph num="(90)">
          <text>“Ullage” means the volume above the liquid in a storage tank as calculated by subtracting the gross volume of liquid in the storage tank from the maximum capacity of the storage tank, as listed on the applicable tank chart.</text>
        </paragraph>
        <paragraph num="(91)">
          <text>“Unattended” means there is no attendant or employee that is on duty and available to customers at a motor fuel dispensing facility.</text>
        </paragraph>
        <paragraph num="(92)">
          <text>“USCG” means the United States Coast Guard.</text>
        </paragraph>
        <paragraph num="(93)">
          <text>“Used oil” means any petroleum-based oil or synthetic oil which through use, storage, or handling has become unsuitable for its original purpose due to the presence of impurities or loss of original properties.</text>
        </paragraph>
        <paragraph num="(94)">
          <text>“USEPA” means the United States Environmental Protection Agency.</text>
        </paragraph>
        <paragraph num="(95)">
          <text>“Vessel” means every watercraft or other artificial contrivance used, or capable of being used, as a means of transportation on the waters of the State.</text>
        </paragraph>
        <paragraph num="(96)">
          <text>“Waters of the State” includes:</text>
          <paragraph num="(a)">
            <text>Both surface and underground waters within the boundaries of the State subject to its jurisdiction, including that portion of the Atlantic Ocean within the boundaries of the State;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The Chesapeake Bay and its tributaries;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>All ponds, lakes, rivers, streams, public ditches, tax ditches, and public drainage systems within the State, other than those designed and used to collect, convey, or dispose of sanitary sewage; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The floodplain of free-flowing waters determined by the Department on the basis of the 100-year flood frequency.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Incorporation by Reference.">
      <paragraph num="A.">
        <text>In this subtitle, the following documents published by the American Petroleum Institute (API) are incorporated by reference:</text>
        <paragraph num="(1)">
          <text>Specification for Bolted Tanks for Storage of Production Liquids (API Specification 12B, 17th Edition, December 2020);</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Specification for Field-welded Tanks for Storage of Production Liquids (API Specification 12D, 12th Edition, June 2017);</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Risk-based Inspection (API Recommended Practice 580, 3rd Edition, February 2016);</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Welded Tanks for Oil Storage (API Standard 650, 13th Edition, March 2020, Errata 1, January 2021);</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Cathodic Protection of Aboveground Petroleum Storage Tanks (API Recommended Practice 651, 4th Edition, September 2014);</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Tank Inspection, Repair, Alteration, and Reconstruction (API Standard 653, 5th Edition, November 2014), except Annex H — Similar Service Assessment;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Closure of Underground Petroleum Storage Tanks (API Recommended Practice 1604, 4th Edition, February 2021);</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Installation of Underground Petroleum Storage Systems (API Recommended Practice 1615, 6th Edition, April 2011, Reaffirmed May 2020);</text>
        </paragraph>
        <paragraph num="(9)">
          <text>Storing and Handling Ethanol and Gasoline-ethanol Blends at Distribution Terminals and Filling Stations (API Recommended Practice 1626, 2nd Edition, August 2010, Reaffirmed May 2020);</text>
        </paragraph>
        <paragraph num="(10)">
          <text>Interior Lining and Periodic Inspection of Underground Storage Tanks (API Standard 1631, 5th Edition, June 2001, Reaffirmed May 2020);</text>
        </paragraph>
        <paragraph num="(11)">
          <text>Using the API Color-Symbol System to Identify Equipment, Vehicles, and Transfer Points for Petroleum Fuels and Related Products at Dispensing and Storage Facilities and Distribution Terminals (API Recommended Practice 1637, 4th Edition, April 2020);</text>
        </paragraph>
        <paragraph num="(12)">
          <text>Venting Atmospheric and Low-pressure Storage Tanks (API Standard 2000, 7th Edition, March 2014, Reaffirmed April 2020); and</text>
        </paragraph>
        <paragraph num="(13)">
          <text>Overfill Protection for Storage Tanks in Petroleum Facilities (ANSI/API Standard 2350, 5th Edition, September 2020).</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>In this subtitle, the following documents published by the National Association of Corrosion Engineers (NACE) are incorporated by reference:</text>
        <paragraph num="(1)">
          <text>Control of External Corrosion on Underground or Submerged Metallic Piping Systems (NACE SP0169-2013, Approved April 1969, Revised October 2013);</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Application of Cathodic Protection to Control External Corrosion of Carbon Steel On-Grade Storage Tank Bottoms (NACE SP0193-2016, Approved October 1993, Revised February 2016);</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Corrosion Control of Underground Storage Tank Systems by Cathodic Protection (NACE SP0285-2011, Approved March 1985, Revised March 2011);</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Measurement Techniques Related to Criteria for Cathodic Protection of Underground Storage Tank Systems (NACE Standard TM0101-2012, Approved November 2001, Revised March 2012); and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Measurement Techniques Related to Criteria for Cathodic Protection on Underground or Submerged Metallic Piping Systems (NACE TM0497-2018, Approved September 2018).</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>In this subtitle, the following documents published by the National Fire Protection Association (NFPA) are incorporated by reference:</text>
        <paragraph num="(1)">
          <text>Flammable and Combustible Liquids Code (NFPA 30, 2021 Edition);</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Code for Motor Fuel Dispensing Facilities and Repair Garages (NFPA 30A, 2021 Edition);</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Standard for the Installation of Oil-Burning Equipment (NFPA 31, 2020 Edition);</text>
        </paragraph>
        <paragraph num="(4)">
          <text>National Electrical Code (NFPA 70, 2020 Edition);</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Standard for Tank Vehicles for Flammable and Combustible Liquids (NFPA 385, 2017 Edition); and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Standard System for the Identification of the Hazards of Materials for Emergency Response (NFPA 704, 2022 Edition).</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>In this subtitle, the following documents published by the Petroleum Equipment Institute (PEI) are incorporated by reference:</text>
        <paragraph num="(1)">
          <text>Recommended Practices for Installation of Underground Liquid Storage Systems (PEI/RP100-20, 2020 Edition);</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Recommended Practices for Installation of Aboveground Storage Systems for Motor Vehicle Fueling (PEI/RP200-19, 2019 Edition);</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Recommended Practices for Overfill Prevention for Shop-Fabricated Aboveground Tanks (PEI/RP600-18, 2018 Edition);</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Recommended Practices for Installation of Bulk Storage Plants (PEI/RP800-20, 2020 Edition);</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Recommended Practices for the Inspection and Maintenance of UST Systems (PEI/RP900-17, 2017 Edition);</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Recommended Practices for the Installation of Marina Fueling Systems (PEI/RP1000-14, 2014 Edition);</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities (PEI/RP1200-19, 2019 Edition); and</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Recommended Practices for the Closure of Underground Storage Tank and Shop-Fabricated Aboveground Storage Tank Systems (PEI/RP1700-18, 2018 Edition).</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>In this subtitle, the following documents published by Steel Tank Institute/Steel Plate Fabricators Association (STI/SPFA) are incorporated by reference:</text>
        <paragraph num="(1)">
          <text>Standard for the Inspection of Aboveground Storage Tanks (STI/SPFA SP001, 6th Edition, January 2018);</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Cathodic Protection Testing Procedures for sti-P3 USTs (STI/SPFA R051, Revised April 2017); and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Recommended Practice for the Addition of Supplemental Anodes to sti-P3 USTs (STI/SFPA R972, Revised December 2010).</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>In this subtitle, the following documents published by UL are incorporated by reference:</text>
        <paragraph num="(1)">
          <text>Standard for Safety, Steel Aboveground Tanks for Flammable and Combustible Liquids (UL 142, 10th Edition, May 2019, Revised January 2021); and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Standard for Safety, Special Purpose Aboveground Tanks for Specific Flammable or Combustible Liquids (UL 142A, 1st Edition, May 2018, Revised January 2021).</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>In this subtitle, USEPA Doing Inventory Control Right for Underground Storage Tanks (USEPA 510-B-93-004, November 1993) is incorporated by reference.</text>
      </paragraph>
      <paragraph num="H.">
        <text>In this subtitle, the following test methods as published in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods Compendium” (USEPA SW-846, 3rd Edition) are incorporated by reference:</text>
        <paragraph num="(1)">
          <text>USEPA Test Method 1311 — Toxicity Characteristic Leaching Procedure (July 1992, Revision 0);</text>
        </paragraph>
        <paragraph num="(2)">
          <text>USEPA Test Method 8015C — Nonhalogenated Organics by Gas Chromatography (February 2007, Revision 3);</text>
        </paragraph>
        <paragraph num="(3)">
          <text>USEPA Test Method 8082A — Polychlorinated Biphenyls (PCBs) by Gas Chromatography (February 2007, Revision 1); and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>USEPA Test Method 8260D — Volatile Organic Compounds by Gas Chromatography/Mass Spectrometry (June 2018, Revision 4).</text>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>In this subtitle, the following test methods as published in “Selected Analytical Methods for Environmental Remediation and Recovery (SAM) 2017” (USEPA/600/R-17/356, 2017) are incorporated by reference:</text>
        <paragraph num="(1)">
          <text>USEPA Test Method 524.2 — Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry (1995 Edition, Revision 4.1); and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>USEPA Test Method 8015D — Nonhalogenated Organics Using GC/FID (June 2003, Revision 4).</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="General Provisions and Specifically Prohibited Acts.">
      <paragraph num="A.">
        <text>The requirements of this chapter do not relieve a person from the duty to comply with any other federal, State, or local government statute, regulation, or authorization applicable to an activity, operation, or authorization regulated under this subtitle.</text>
      </paragraph>
      <paragraph num="B.">
        <text>The Department, at its discretion, may modify a testing requirement of this subtitle for an owner, an operator, and a person in charge of a storage tank system, vehicle, vessel, or equipment subject to the provisions of this subtitle if:</text>
        <paragraph num="(1)">
          <text>The modification does not violate a general restriction or specifically prohibited act under §§C and D of this regulation;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The modification is not prohibited under a State statute or a federal statute, rule, or regulation; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The modification is as protective of public health and the environment as the testing requirement modified.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>General Restrictions. A person subject to the requirements of this chapter, as defined in Regulation .01B of this chapter, may not engage in an activity or operation in a manner likely to:</text>
        <paragraph num="(1)">
          <text>Create a nuisance;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Create air pollution;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Cause a discharge of pollutants to waters of this State, except in accordance with a valid permit issued by the Department under Environment Article, §9-323, Annotated Code of Maryland;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Impair the quality of the environment; or</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Create other hazards to the public health, safety, welfare, or comfort as may be determined by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Specifically Prohibited Acts.</text>
        <paragraph num="(1)">
          <text>Prohibition Against Hazardous Substance Releases.</text>
          <paragraph num="(a)">
            <text>A person may not cause a release of a hazardous substance.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A person violating §D(1)(a) of this regulation is subject to:</text>
            <paragraph num="(i)">
              <text>Any applicable sanctions under Environment Article, Title 7, Subtitle 2, Part VIII, Annotated Code of Maryland;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The modification, suspension, or revocation of a permit issued under the provisions of COMAR 26.10.02.04; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The Hazardous Substance Response Action Plan requirements under Environment Article, §7-222, Annotated Code of Maryland and COMAR 26.14.01 and 26.14.02.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Prohibition Against Oil Pollution.</text>
          <paragraph num="(a)">
            <text>A person may not pump, spill, release, discharge, throw, drain, deposit, or cause to be deposited oil or other matter containing oil into, near, or in an area likely to pollute waters of the State.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A person may not pump, spill, release, discharge, deposit or cause to be deposited bilge or ballast water or water from any receptacle containing oil in a manner by which oil may escape into, or in an area likely to pollute, waters of the State.</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A person violating §D(2)(a) or (b) of this regulation is subject to:</text>
            <paragraph num="(i)">
              <text>Sanctions under Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The modification, suspension, or revocation of a license or permit issued under the provisions of this subtitle; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Any other sanctions provided under law.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>The Department may exempt a person from §D(2)(a) and (b) of this regulation if:</text>
            <paragraph num="(i)">
              <text>There is an emergency imperiling life or property, an unavoidable accident, a collision, or stranding; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The person is authorized by the Department to remove an oil discharge from waters of the State.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>False Statements. A person may not knowingly make a false statement, representation, or certification to the Department in any application, record, report, plan, or other document filed or required to be maintained under this subtitle.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Tampering with Monitoring Devices. A person may not falsify, tamper with, or knowingly render inaccurate a monitoring device or method required to be maintained under this subtitle.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Wetlands and Waterways.</text>
        <paragraph num="(1)">
          <text>A person may not install, construct, or extend a storage tank, storage tank system, oil storage facility, oil handling facility, or regulated substance storage facility in the following locations unless the person obtains all of the applicable authorizations listed in §E(2) of this regulation:</text>
          <paragraph num="(a)">
            <text>A special flood hazard area;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A tidal or nontidal wetland;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A nontidal wetland buffer; or</text>
          </paragraph>
          <paragraph num="(d)">
            <text>A 100-year floodplain of free-flowing waters, as described under Regulation .02B(96)(d) of this chapter.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A person installing, constructing, or extending a storage tank, storage tank system, oil storage facility, oil handling facility, or regulated substance storage facility in one of the areas listed in §E(1) of this regulation shall first obtain:</text>
          <paragraph num="(a)">
            <text>The applicable authorizations issued under Environment Article, Title 5 or 16, Annotated Code of Maryland and COMAR 23.02.04, 26.17.04, 26.23.02, 26.23.03, 26.24.02, or 26.24.03; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If required under 33 U.S.C §1341(a), a Water Quality Certification issued by the Department in accordance with 33 U.S.C §1341, 40 CFR Part 121, and COMAR 26.08.02.10.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Reporting an Oil Spill, Release, or Discharge.">
      <paragraph num="A.">
        <text>A person spilling, releasing, or discharging oil or allowing the spill, release, or discharge of oil, or who either actively or passively participates in a spill, release, or discharge of oil, either from a land-based installation, including vehicles in transit, or from any vessel, including a ship or boat of any kind, shall:</text>
        <paragraph num="(1)">
          <text>Report the incident to the Department immediately, but not later than 2 hours after detection of the spill, release, or discharge, in accordance with §B of this regulation; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Remain available until clearance to leave the scene of the incident is given by the appropriate official as designated under §C of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>A person reporting an oil spill, release, or discharge to the Department shall include in the report all of the following information:</text>
        <paragraph num="(1)">
          <text>Time and date of the spill, release, or discharge;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Location and cause of the spill, release, or discharge;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Mode of transportation or type of facility involved;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Type and quantity of oil spilled, released, or discharged;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Assistance required;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Name, address, and telephone number of the person making the report; and</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Any other pertinent information requested by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>The authority to grant a person responsible for the discharge clearance to leave the scene of a spill, release, or discharge is designated as follows:</text>
        <paragraph num="(1)">
          <text>A representative of the Department may grant any person responsible for the discharge clearance to leave the scene either by telephone or in-person at the scene;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Without first giving notice to and receiving approval from the Department, a representative of any Maryland emergency fire and rescue service or any State, county, or local police officer on the scene may grant a person responsible for the discharge clearance to leave the scene to a person that is responsible for a discharge of less than 250 gallons; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>After giving notice to and receiving approval from the Department, a representative of any Maryland emergency fire and rescue service or any State, county, or local police officer on the scene may grant a person responsible for the discharge clearance to leave the scene to a person that is responsible for a discharge of more than 250 gallons.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Before granting a person responsible for the discharge clearance to leave the scene, the designated official shall obtain the person’s name, address, and telephone number as well as information on how the spill, release, or discharge occurred.</text>
      </paragraph>
      <paragraph num="E.">
        <text>Written Report of the Occurrence.</text>
        <paragraph num="(1)">
          <text>A person responsible for the discharge shall submit a written report of the occurrence in accordance with the requirements of this section if:</text>
          <paragraph num="(a)">
            <text>5 gallons or more of oil was spilled, released, or discharged;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Oil was discharged to waters of the State, regardless of the amount of oil spilled, released, or discharged; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Directed by the Department to submit a written report of the occurrence.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Within ten working days, or as directed by the Department, after completion of removal work required under Regulation .06 of this chapter, a person responsible for the discharge shall prepare a written report of the occurrence and promptly submit the report to the Department.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A person responsible for the discharge shall prepare the written report of the occurrence on company letterhead and include all of the following information:</text>
          <paragraph num="(a)">
            <text>Date, time, and place of the spill, release, or discharge;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Amount and type of oil spilled, released, or discharged;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A complete description of circumstances contributing to the spill, release, or discharge;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>A complete description of the containment and removal operations performed, including disposal sites to which oil refuse was transported;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Procedures, methods, and precautions instituted to prevent recurrence of an oil spill, release, or discharge from the facility involved;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Any other information considered necessary or required by the Department for a complete description of the incident; and</text>
          </paragraph>
          <paragraph num="(g)">
            <text>A certification that the information provided is true and correct to the knowledge of the person signing the report.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Removal of an Oil Spill, Release, or Discharge.">
      <paragraph num="A.">
        <text>Responsibility for Performing a Removal.</text>
        <paragraph num="(1)">
          <text>The responsibility for the prompt control and removal of any oil spill, release, or discharge or threat of a spill, release, or discharge shall be with the person responsible for the discharge.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>For spills, releases, or discharges occurring from an improperly abandoned storage tank system, the current landowners and any other person who owned, operated, leased, or was otherwise responsible for the storage tank system at the time it was abandoned shall also be responsible for the oil removal.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>A person’s responsibility under §A of this regulation shall continue until removal of the spill, release, or discharge or threat of a spill, release, or discharge has been accomplished to the satisfaction of the Department.</text>
      </paragraph>
      <paragraph num="C.">
        <text>A person shall accomplish the removal of oil by physical or mechanical means such as the use of skimming devices or vacuum systems, by the use of inert sorbent material, or by any other method specifically approved by the Department.</text>
      </paragraph>
      <paragraph num="D.">
        <text>If sorbent material is employed, a person shall remove and dispose of the sorbent material in accordance with all federal, State, and local requirements.</text>
      </paragraph>
      <paragraph num="E.">
        <text>A person may not use collecting agents, dispersants, or sinking agents except when authorized in writing by the Department.</text>
      </paragraph>
      <paragraph num="F.">
        <text>Unless the appropriate federal official is directing the removal, the Department shall assume control of any spill, release, or discharge incident when the Department determines that a person responsible for the discharge is:</text>
        <paragraph num="(1)">
          <text>Not acting promptly to perform the removal of the spill, release, or discharge; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Not completing the removal in a manner that controls or rectifies the conditions constituting an emergency or hazard.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>A person shall perform removal activities that are:</text>
        <paragraph num="(1)">
          <text>Consistent with Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Not prohibited under Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland, the National Contingency Plan, or the directions of a Departmental or federal on-scene coordinator.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Site Status Letters.">
      <paragraph num="A.">
        <text>The Department may issue notice of compliance, site condition, removal suspension, and final closure letters to either a person responsible for the discharge or any other person associated with a site subject to regulatory requirements under this subtitle.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Notice of Compliance Letter. The Department shall issue, upon request, a notice of compliance letter to a person who has received from the Department a notice of a violation of one or more of the regulatory provisions of this subtitle after the violation is corrected to the satisfaction of the Department.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Site Condition Letter. The Department shall issue, upon request, a site condition letter stating whether:</text>
        <paragraph num="(1)">
          <text>The Department requires corrective action at a site; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A site is in compliance with the regulations of this subtitle.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Removal Suspension Letter.</text>
        <paragraph num="(1)">
          <text>Unless otherwise provided under §F of this regulation, the Department shall issue, upon request, a removal suspension letter if the Department determines that no further treatment of soil, groundwater or surface water is required for a specific spill, release, or discharge undergoing corrective action in accordance with Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland, Regulation .06 of this chapter, or COMAR 26.10.09.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>After receiving a removal suspension letter, a person responsible for the discharge or a person performing a removal shall continue to monitor a site as may be required by the Department.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If a removal suspension letter is issued, the letter is applicable to any transferee of title, successor or assignee of a person responsible for the discharge, or any other person who performed a removal.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Final Closure Letter.</text>
        <paragraph num="(1)">
          <text>Unless otherwise provided under §F of this regulation, the Department shall issue a final closure letter after the Department determines that a site where a spill, release, or discharge of oil occurred is in compliance with Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland, Regulation .06 of this chapter, or COMAR 26.10.09.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The Department shall state in a final closure letter that a person responsible for the discharge or a person performing a removal is released from any additional corrective action under this subtitle regarding a spill, release, or discharge, except in those circumstances described under §F of this regulation.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A final closure letter is applicable to any transferee of title, successor or assignee of a person responsible for the discharge, or any other person who performed a removal.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>The Department may require a person responsible for the discharge or a person performing a removal to take further remedial action at a site subject to a letter issued under §§B—E of this regulation if the Department determines that:</text>
        <paragraph num="(1)">
          <text>There is a threat to public health, safety, or welfare or the environment;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A spill, release, or discharge recurs as free phase oil product;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A letter issued under §D or E of this regulation was obtained through fraud or misrepresentation; or</text>
        </paragraph>
        <paragraph num="(4)">
          <text>A new or previously undiscovered spill, release, or discharge of oil requires a corrective action under Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland or the provisions of COMAR 26.10.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>A purchaser of an oil-contaminated property may not be considered a person responsible for the discharge solely as a result of the purchase of the property, unless the purchaser meets the criteria for a person responsible for the discharge under Regulation .02B of this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Oil Transfer License.">
      <paragraph num="A.">
        <text>Oil Transfer License Requirement. Except for a vessel or barge, a person may not transfer oil in the State without an Oil Transfer License issued by the Department.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Application Requirements. Before an Oil Transfer License may be issued by the Department, an applicant shall submit to the Department all of the following information:</text>
        <paragraph num="(1)">
          <text>A completed application on a form provided by the Department;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If applicable, satisfactory evidence that the applicant has implemented or is in the process of implementing:</text>
          <paragraph num="(a)">
            <text>State and federal plans and regulations to control pollution related to oil, petroleum products, and their byproducts; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A plan for the abatement of pollution related to oil, petroleum products, and their byproducts when a spill, release, or discharge occurs;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Proof that the applicant is registered with the Maryland Department of Assessments and Taxation and that the person is in good standing with the State at the time the application for an Oil Transfer License is submitted;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Proof of Workers’ Compensation Insurance or, if not required, a certificate of compliance with the Maryland Workers’ Compensation Act; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Proof of the applicant’s registration with the Comptroller of Maryland’s Motor Fuel Tax Unit or a signed document that registration by the applicant with the unit is not required.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>License Effective Period. An Oil Transfer License issued by the Department has an effective period of 5 years, unless the license is:</text>
        <paragraph num="(1)">
          <text>Surrendered, suspended, revoked, or otherwise terminated by the Department; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Issued by the Department, with reasons stated, with an effective period of less than 5 years.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>License Renewal.</text>
        <paragraph num="(1)">
          <text>In addition to satisfying the requirements under §B of this regulation, a licensee applying to renew an Oil Transfer License may not have any tax liabilities with the Comptroller of Maryland.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>When a tax liability is identified, the licensee will be notified by the Department and the license renewal process will stop until the liability is resolved.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The licensee shall determine the cause of the tax liability and notify the Department in writing when the liability is resolved.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>License Cancellation. A licensee that determines they no longer require an Oil Transfer License shall notify the Department in writing within 60 days of making the determination.</text>
      </paragraph>
      <paragraph num="F.">
        <text>Oil Transfer Fee.</text>
        <paragraph num="(1)">
          <text>The Department shall impose a fee on each barrel of oil transferred in the State, with the fee assessed only once at the first point of transfer in the State.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The fee amount is established under Environment Article, §4-411, Annotated Code of Maryland.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The licensee that offloads or onloads oil at the first point of transfer in the State is responsible for paying the fee.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>A licensee shall pay the fee on a quarterly basis to the Department not later than the following due dates or, if the payment is received by the Department after a due date, postmarked two days before the following due dates:</text>
          <paragraph num="(a)">
            <text>First Quarter (July, August, September) — October 31;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Second Quarter (October, November, December) — January 31;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Third Quarter (January, February, March) — April 30; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Fourth Quarter (April, May, June) — July 31.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>Reports Required. A licensee, including one that does not transfer oil during one or more quarters identified in §F of this regulation, shall:</text>
        <paragraph num="(1)">
          <text>Report to the Department the barrels of oil transferred each quarter on forms provided by the Department; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Submit the completed forms with the fee payment to the Department in accordance with §F of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>The transfer of the following products are exempt from the oil transfer fee and reporting requirements:</text>
        <paragraph num="(1)">
          <text>Oil in containers of less than 100 gallons capacity; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Oil products not listed under §I of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>The following oil and petroleum products are subject to the license fee:</text>
        <paragraph num="(1)">
          <text>Gasoline;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Gasohol, including:</text>
          <paragraph num="(a)">
            <text>Alcohols denatured with oil; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Ethanol that is intended to be used as a motor fuel or fuel source;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Kerosene;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Aviation fuels;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Diesel motor fuel, including biodiesel fuel, regardless of whether the fuel is petroleum based;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Heating oil;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Fuel oils, including fuel oil that is blended or mixed with:</text>
          <paragraph num="(a)">
            <text>Biofuels; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Processed or re-refined used oil;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(8)">
          <text>Liquid asphalts;</text>
        </paragraph>
        <paragraph num="(9)">
          <text>Hydraulic oils;</text>
        </paragraph>
        <paragraph num="(10)">
          <text>Lubricating oils; and</text>
        </paragraph>
        <paragraph num="(11)">
          <text>Crude oil.</text>
        </paragraph>
      </paragraph>
      <paragraph num="J.">
        <text>Audits.</text>
        <paragraph num="(1)">
          <text>The Department may perform audits of a report, required under §G of this regulation, submitted by a licensee to ensure the licensee is reporting properly and completely.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Upon the request of the Department, a licensee shall provide records to the Department during an audit in accordance with Regulation .20 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="K.">
        <text>Failure to Submit Oil Transfer Fee Payments and Reports.</text>
        <paragraph num="(1)">
          <text>If a licensee fails to submit an oil transfer fee payment and accompanying report to the Department for a given quarter, the Department shall determine the amount of oil transfer fee due using available information and provide notice of this determination to the licensee liable for payment of the oil transfer fee.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A licensee shall have an opportunity for a contested case hearing if the licensee files a written request with the Department within 30 calendar days of receiving a notice of determination issued under §K(1) of this regulation.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A determination made in accordance with §K(1) of this regulation is considered final, unless:</text>
          <paragraph num="(a)">
            <text>The licensee liable for the oil transfer fee payment requests a hearing in accordance with §K(2) of this regulation; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The Department, on its own, redetermines the oil transfer fee amount owed by the licensee liable for the oil transfer fee payment.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>The Department shall conduct a contested case hearing in accordance with State Government Article, Title 10, Subtitle 2, Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".09" heading="Oil Operations Permits.">
      <paragraph num="A.">
        <text>Individual Oil Operations Permit.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility that meets one or more of the following conditions shall obtain an Individual Oil Operations Permit in accordance with Regulation .11 of this chapter:</text>
          <paragraph num="(a)">
            <text>An oil storage facility or oil handling facility having an aggregate storage capacity of 10,000 gallons or greater;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A marina with an AST system that is part of a motor fuel dispensing facility;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>An oil storage facility or oil handling facility involved in the handling, reuse, processing, re-refining, or disposal of used oil that has an aggregate storage capacity of 1,000 gallons or greater of used oil;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>An oil storage facility or oil handling facility involved in the delivery or transfer of oil:</text>
            <paragraph num="(i)">
              <text>Using a truck tank or transport with a cargo tank capacity of 500 gallons or greater; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>To or from any point within the State, including deliveries from out-of-State facilities;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(e)">
            <text>An oil storage facility or oil handling facility with a loading/unloading rack or transfer area used in the transfer of oil to or from a truck tank, transport, or tank car;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>An oil storage facility or oil handling facility otherwise permitted under §B of this regulation that delivers, transfers, or stores oil if the Department determines the delivery, transfer, or storage of oil poses a water pollution hazard due to the facility’s size, nature, or location;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>An oil-contaminated soil facility as defined in COMAR 26.10.13.02B; and</text>
          </paragraph>
          <paragraph num="(h)">
            <text>An oil storage facility or oil handling facility whose operations involve the solidification/stabilization of oil sludge, oil refuse, or oil mixed with other waste.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility required to have an Individual Oil Operations Permit shall comply with the following provisions of COMAR 26.10:</text>
          <paragraph num="(a)">
            <text>Regulations .04—.06 of this chapter and COMAR 26.10.08 and 26.10.09 when a suspected or confirmed spill, release, or discharge occurs;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Regulations .03, .04, .10—.12, .19, and .24 of this chapter;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>For an aboveground oil storage facility:</text>
            <paragraph num="(i)">
              <text>Regulations .18, .20, and .21 of this chapter;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If the facility is located at a marina, Regulation .14 of this chapter;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>If the facility manages used oil, COMAR 26.10.15;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>If the facility has shop-fabricated ASTs, COMAR 26.10.17;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>If the facility has field-erected ASTs, COMAR 26.10.18;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>If the facility has underground piping connected to an AST, COMAR 26.10.03.02 and 26.10.05.02D; and</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>COMAR 26.10.10, which specifies the closure requirements for underground piping connected to an AST;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>If the facility conducts deliveries or transfers of oil using a truck tank or transport, Regulations .16 and .17 of this chapter;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The oil transfer requirements in Regulation .18 of this chapter;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>For an oil-contaminated soil facility, COMAR 26.10.13; and</text>
          </paragraph>
          <paragraph num="(g)">
            <text>For an oil solidification/stabilization facility, Regulation .15 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>General Oil Operations Permit by Rule.</text>
        <paragraph num="(1)">
          <text>Unless required to obtain an Individual Oil Operations Permit under §A(1) of this regulation, an owner, an operator, and a person in charge of one of the following oil storage facilities or oil handling facilities is permitted by the Department to operate provided the conditions specified in this section are met:</text>
          <paragraph num="(a)">
            <text>An oil storage facility or oil handling facility with an aggregate storage capacity of less than 10,000 gallons;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An oil storage facility or oil handling facility involved in the handling, reuse, processing, re-refining, or disposal of used oil with an aggregate storage capacity of less than 1,000 gallons of used oil; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>An oil storage facility or oil handling facility involved in the delivery or transfer of oil:</text>
            <paragraph num="(i)">
              <text>Using a truck tank or transport with a cargo tank capacity of less than 500 gallons; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>To or from any point within the State, including deliveries from out-of-State facilities.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility permitted to operate under a General Oil Operations Permit shall comply with the following provisions of COMAR 26.10:</text>
          <paragraph num="(a)">
            <text>Regulations .04—.06 of this chapter and COMAR 26.10.08 and 26.10.09 when a suspected or confirmed spill, release, or discharge occurs;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Regulations .03, .04, .10, .12, .19, and .24 of this chapter;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>If the facility has underground piping connected to an AST, COMAR 26.10.03.02 and 26.10.05.02D;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>If the facility has shop-fabricated ASTs, COMAR 26.10.17;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>If the facility has field-erected ASTs, COMAR 26.10.18;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>If the facility manages used oil, COMAR 26.10.15; and</text>
          </paragraph>
          <paragraph num="(g)">
            <text>If the facility conducts oil deliveries or transfers using a truck tank or transport, Regulations .16 and .17 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".10" heading="Registration of AST Systems.">
      <paragraph num="A.">
        <text>Exception.</text>
        <paragraph num="(1)">
          <text>Unless otherwise directed by the Department, an owner, an operator, and a person in charge of an oil storage facility or oil handling facility is not required to register an AST system located at the facility with the Department if:</text>
          <paragraph num="(a)">
            <text>The oil storage facility is a single-family residential property;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The oil storage facility or oil handling facility has an aggregate storage capacity of 2,500 gallons or less and operates under a General Oil Operations Permit, as required under Regulation .09B of this chapter; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The AST system stores oil for less than six consecutive months.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>To address a special circumstance at a facility, the Department may approve a written request for an exemption from the AST system registration requirement under §B of this regulation submitted by an owner, an operator, or a person in charge of an oil storage facility or oil handling facility otherwise required to register an AST system with the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Registration Requirement.</text>
        <paragraph num="(1)">
          <text>Except as provided under §A of this regulation, an owner, an operator, and a person in charge of an oil storage facility or oil handling facility:</text>
          <paragraph num="(a)">
            <text>Shall register, and maintain current registration of, each AST system located at the facility with the Department; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>May not allow the receipt of oil to, or selling or dispensing of oil from, an AST system not registered with the Department.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Prior to selling or transferring ownership of an oil storage facility or oil handling facility or an AST system intended to be used by a purchaser or transferee for the storage of oil in Maryland, an owner, an operator, and a person in charge of an oil storage facility or oil handling facility required to register an AST system under §B(1) of this regulation shall:</text>
          <paragraph num="(a)">
            <text>Inform the purchaser or transferee of the registration requirements under this regulation; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If an oil storage facility or oil handling facility described under §D of this regulation, provide the purchaser or transferee with a copy of the current registration form.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Facility with an Individual Oil Operations Permit. An owner, an operator, and a person in charge of an oil storage facility or oil handling facility required to obtain an Individual Oil Operations Permit under Regulation .09A of this chapter shall register and maintain registration of each AST system located at the facility:</text>
        <paragraph num="(1)">
          <text>As part of the application process for a new or renewal Individual Oil Operations Permit in accordance with Regulation .11 of this chapter; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If required under Regulation .12B of this chapter, by requesting a modification of an effective Individual Oil Operations Permit.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Facility with a General Oil Operations Permit. An owner, an operator, and a person in charge of an oil storage facility or oil handling facility with an aggregate storage capacity of greater than 2,500 gallons that operates under a General Oil Operations Permit, as required under Regulation .09B of this chapter, shall register and maintain registration for each AST system located at the facility in accordance with the registration procedures of this section.</text>
        <paragraph num="(1)">
          <text>Registration Form. An owner, an operator, or a person in charge of an oil storage facility or oil handling facility:</text>
          <paragraph num="(a)">
            <text>Shall register or amend the registration for each AST system located at the facility using a registration form provided by the Department;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>May use one registration form to register multiple AST systems at a single facility;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>May not use one registration form to register multiple AST systems located at more than one facility;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Shall provide all of the required information on the registration form, including information unchanged since the last registration form was submitted to the Department for the AST system; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Shall sign and date each registration form submitted to the Department.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Registration Schedule. An owner, an operator, or a person in charge of an oil storage facility or oil handling facility shall:</text>
          <paragraph num="(a)">
            <text>Register an AST system with the Department in accordance with the following schedule:</text>
            <paragraph num="(i)">
              <text>If the AST system is installed on or after June 13, 2022, within 30 days of installing the AST system; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If the AST system was installed before June 13, 2022, not later than 18 months after June 13, 2022; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Submit an amended registration form to the Department within 30 days of one or more of the following changes to an AST system or an oil storage facility or oil handling facility:</text>
            <paragraph num="(i)">
              <text>The sale, transfer of ownership, or change in ownership structure;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A change in the oil product stored in the AST system;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A change in status of the AST system from or to in-service, permanently closed or out-of-service, including a change-in-service to store a non-oil product in the AST system; or</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The installation of a new or replacement AST system at the facility.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Recordkeeping. An owner, an operator, or a person in charge of an oil storage facility or oil handling facility shall:</text>
          <paragraph num="(a)">
            <text>Maintain a copy of each complete AST system registration form at the oil storage facility or oil handling facility; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Make a copy of a complete AST system registration form available upon request by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".11" heading="Requirements for the Application and Issuance of an Individual Oil Operations Permit.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility required to obtain an Individual Oil Operations Permit under Regulation .09A of this chapter shall complete, on forms provided by the Department, and submit to the Department:</text>
        <paragraph num="(1)">
          <text>An application for an Individual Oil Operations Permit; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A plan for notification, containment, and removal of a spill, release, or discharge of oil.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility shall submit the following additional documentation with the forms required under §A of this regulation to the Department:</text>
        <paragraph num="(1)">
          <text>Satisfactory evidence that the oil storage facility or oil handling facility is in compliance with all applicable county zoning and land use requirements;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Proof of Workers’ Compensation Insurance or, if not required, a certificate of compliance with the Maryland Workers’ Compensation Act;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If the oil storage facility or oil handling facility is used in the operation of a commercial or business entity, certification and proof that:</text>
          <paragraph num="(a)">
            <text>The owner has registered the commercial or business entity with the Maryland Department of Assessments and Taxation; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The commercial or business entity is in good standing with the State at the time the application for an Individual Oil Operations Permit is submitted; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>If a marine oil facility, an updated response plan in accordance with Regulation .21A of this chapter when requested by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility shall include in the plan for notification, containment, and removal required under §A of this regulation the following information to address containment and removal operations for an oil spill, release, or discharge:</text>
        <paragraph num="(1)">
          <text>A list of names and telephone numbers of individuals to be notified in the event of an oil spill, release, or discharge at the facility;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Provisions for quick control of an oil spill, release, or discharge, including personnel assignments, equipment and personnel locations, and procedures necessary to obtain equipment and materials;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A list of contractors, equipment, and disposal facilities that may be used for containment and removal;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Confirmation the facility has an up-to-date federal SPCC Plan; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Additional information as requested by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility shall submit the documents required in §§A—C of this regulation to the Department not later than 60 days prior to:</text>
        <paragraph num="(1)">
          <text>A new oil storage facility receiving, selling, or dispensing oil; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A new oil handling facility initiating oil operations.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Renewal. A permittee shall submit an application for the renewal of an Individual Oil Operations Permit in accordance with §§A—C of this regulation not later than 60 days before the expiration of the Individual Oil Operations Permit.</text>
      </paragraph>
      <paragraph num="F.">
        <text>Registration of an AST System. An owner, an operator, and a person in charge of an oil storage facility or oil handling facility required under Regulation .10 of this chapter to register each AST system located at the facility shall comply with the registration requirement by submitting a complete permit application in accordance with §§A—C of this regulation.</text>
      </paragraph>
      <paragraph num="G.">
        <text>When issuing an Individual Oil Operations Permit, the Department shall:</text>
        <paragraph num="(1)">
          <text>Review an application for an Individual Oil Operations Permit submitted by an owner, an operator, and a person in charge of an oil storage facility or oil handling facility completed in accordance §§A—C of this regulation;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Inspect each oil storage facility or oil handling facility for which the application was submitted, except for:</text>
          <paragraph num="(a)">
            <text>Truck tank and transport facilities having no AST systems; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Out-of-State oil delivery facilities; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Issue an Individual Oil Operations Permit to the applicant if the Department determines that:</text>
          <paragraph num="(a)">
            <text>The applicable requirements of COMAR 26.10 can be met;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A facility is properly and adequately equipped to prevent oil pollution, and to contain and remove oil spills, releases, and discharges;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A person in charge of a facility has the capability to handle the oil in accordance with the applicable requirements of COMAR 26.10; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility has:</text>
            <paragraph num="(i)">
              <text>No tax liabilities with the Maryland Comptroller’s Office;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Submitted to the Department satisfactory evidence that the oil storage facility or oil handling facility is in compliance with all applicable county zoning and land use requirements;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Provided proof that Workers’ Compensation Insurance requirements have been satisfied; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Provided proof that the person is registered with the Maryland Department of Assessments and Taxation and is in good standing with the State.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>Permit Effective Period. An Individual Oil Operations Permit issued by the Department has an effective period of 5 years, unless the permit is:</text>
        <paragraph num="(1)">
          <text>Surrendered, suspended, revoked, or otherwise terminated by the Department; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Issued by the Department, with reasons stated, with an effective period of less than 5 years.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".12" heading="Conditions for the Denial, Suspension, Revocation, and Modification of an Oil Transfer License or Oil Operations Permit.">
      <paragraph num="A.">
        <text>Oil Transfer License.</text>
        <paragraph num="(1)">
          <text>After written notification by the Department and an opportunity to request a hearing, the Department may deny a person’s application for an Oil Transfer License or suspend or revoke a licensee’s Oil Transfer License if the Department determines that:</text>
          <paragraph num="(a)">
            <text>A violation of a provision of the Oil Transfer License or other applicable federal, State, or local requirements related to oil pollution has occurred;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A violation of the Environment Article, Annotated Code of Maryland or a regulation adopted under the Environment Article, Annotated Code of Maryland has occurred;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>False or inaccurate information or data was provided in:</text>
            <paragraph num="(i)">
              <text>An application for an Oil Transfer License;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A report, submitted to the Department, on the barrels of oil transferred within a quarter by a licensee; or</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Any other document submitted to the Department under the terms and conditions of an Oil Transfer License;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>A licensee has failed to submit to the Department an oil transfer fee payment or accompanying report on the barrels of oil transferred for one or more quarters;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Issuance of an Oil Transfer License would pose a risk of harm to public health, safety, or welfare or the environment; or</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Any other good cause exists for denying, suspending, or revoking an Oil Transfer License.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Once the Department denies a person’s application to renew an Oil Transfer License or suspends or revokes a person’s Oil Transfer License, the person shall cease activities authorized under the license in a manner determined by the Department.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The filing of a hearing request made in accordance with §D of this regulation does not stay the Department’s decision to deny, revoke, or suspend an Oil Transfer License.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Individual Oil Operations Permit.</text>
        <paragraph num="(1)">
          <text>Denial, Suspension, or Revocation.</text>
          <paragraph num="(a)">
            <text>The Department may deny a person’s application for an Individual Oil Operations Permit or suspend or revoke a permittee’s Individual Oil Operations Permit if the Department determines that:</text>
            <paragraph num="(i)">
              <text>A violation of a provision of an Individual Oil Operations Permit or other applicable federal, State, or local requirements related to oil pollution has occurred;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A violation of the Environment Article, Annotated Code of Maryland or a regulation adopted under the Environment Article, Annotated Code of Maryland has occurred;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>False or inaccurate information or data was provided in an application for an Individual Oil Operations Permit or any other document submitted to the Department under the terms and conditions of an Individual Oil Operations Permit;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The permittee has failed to report to the Department a substantial change that requires a permit modification under §B(2) of this regulation;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Issuance of an Individual Oil Operations Permit would pose a risk of harm to public health, safety, or welfare or the environment; or</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Any other good cause exists for denying an application for an Individual Oil Operations Permit or suspending or revoking an Individual Oil Operations Permit.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Once the Department denies a person’s application to renew an Individual Oil Operations Permit or suspends or revokes a person’s Individual Oil Operations Permit, the person shall cease activities authorized under the permit in a manner determined by the Department.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Modification.</text>
          <paragraph num="(a)">
            <text>The Department may modify an Individual Oil Operations Permit as necessary to carry out the intent and purpose of COMAR 26.10 and a permittee may submit to the Department a request to modify an Individual Oil Operations Permit to implement a substantial change listed in §B(2)(b) of this regulation.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Before implementing a change, a permittee shall submit a request to the Department to modify an Individual Oil Operations Permit for one or more of the following substantial changes in either the size or scope of the permitted oil operation or in the information provided to the Department in the permit application:</text>
            <paragraph num="(i)">
              <text>The sale, transfer of ownership, or change in ownership structure of the AST system or the oil storage facility or oil handling facility;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The installation or removal of an AST system at the oil storage facility or oil handling facility;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A change in the methods, processes, or operations for the treatment of oil-contaminated soil;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>A change in methods, processes, or operations used for the solidification/stabilization of oil sludge, oil refuse, or oil mixed with other waste;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>The addition of, or a change in the type of, secondary containment or diking used as containment for an AST system, loading/unloading rack, or transfer area at an oil storage facility or oil handling facility;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>A change in the type of oil stored in an AST system;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>The installation or removal of underground piping associated with an AST system;</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>A change in status of the AST system from or to in-service, permanently closed or out-of-service, including a change-in-service to store a non-oil product in the AST system; and</text>
            </paragraph>
            <paragraph num="(ix)">
              <text>Upon notification by the Department, a change determined by the Department to constitute a substantial change in either the size or scope of the permitted oil operation or in the information provided to the Department in the permit application.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>A permittee requesting a modification of an Individual Oil Operational Permit shall submit to the Department a request in writing on company letterhead and signed by the permittee.</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The Department may deny a permittee’s request to modify an Individual Oil Operations Permit for the reasons provided under §B(1) of this regulation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>General Oil Operations Permit.</text>
        <paragraph num="(1)">
          <text>The Department may suspend or revoke a permittee’s authorization to operate under a General Oil Operations Permit as provided under Regulation .09B of this chapter if the Department determines that:</text>
          <paragraph num="(a)">
            <text>A violation of a condition specified under Regulation .09B of this chapter under which the permittee is required to comply with in the operation an oil storage facility or oil handling facility has occurred;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A violation of an applicable federal, State, or local requirement related to oil pollution has occurred;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A violation of the Environment Article, Annotated Code of Maryland or a regulation adopted under the Environment Article, Annotated Code of Maryland has occurred;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>False or inaccurate information or data was provided in a document required to be submitted to the Department under Regulation .09B of this chapter;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>A permittee’s continued operation of an oil storage facility or oil handling facility under the General Oil Operations Permit would pose a risk of harm to public health, safety, or welfare or the environment; or</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Any other good cause exists for suspending or revoking the authorization provided under Regulation .09B of this chapter.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Once the Department suspends or revokes a person’s authorization to operate under a General Oil Operations Permit, the person shall cease activities permitted under the suspended or revoked General Oil Operations Permit in a manner determined by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Contested Case Hearings.</text>
        <paragraph num="(1)">
          <text>A person whose application for an Oil Transfer License was denied or a person with a suspended or revoked Oil Transfer License shall have an opportunity for a contested case hearing if the person files a written request with the Department not later than 30 calendar days after receiving a notice of the Department’s decision to deny an application for the Oil Transfer License or to suspend or revoke the Oil Transfer License.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Unless a person notified of the Department’s licensing decision makes a timely request for a contested case hearing in accordance with §D(1) of this regulation, the decision is final.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The Department shall conduct a hearing in accordance with the provisions of State Government Article, Title 10, Subtitle 2, Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>A person aggrieved by a permit or order issued by the Department under Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland and the provisions of this chapter may obtain immediate judicial review under State Government Article, §§10-222 and 10-223, Annotated Code of Maryland and the Maryland Rules.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".13" heading="Residential Heating Oil Tanks.">
      <paragraph num="A.">
        <text>Scope. This regulation establishes requirements for the delivery of heating oil to a residential heating oil tank and the use, installation, and permanent closure of a residential heating oil tank.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Heating Oil Delivery.</text>
        <paragraph num="(1)">
          <text>The owner of an oil delivery company shall have a valid Individual Oil Operations Permit issued by the Department:</text>
          <paragraph num="(a)">
            <text>To deliver heating oil to residential heating oil tanks; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>To employ persons to deliver heating oil to residential heating oil tanks.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A person may not deliver heating oil to a residential heating oil tank if the residential heating oil tank has a spill or release, visible or otherwise known, or unstable so as to likely fall over when filled.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A person may not deliver heating oil to a residential heating oil tank unless the residential heating oil tank is equipped with means to determine the heating oil level in the residential heating oil tank at the fill point by one or more of the following methods:</text>
          <paragraph num="(a)">
            <text>A functioning vent whistle with proper vent sizing;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A functioning visual or audible overfill alarm; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A person confirming there is sufficient ullage in the residential heating oil tank for the planned delivery volume.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>A person shall report a suspected or confirmed spill, release, or discharge of heating oil that occurs during a delivery to:</text>
          <paragraph num="(a)">
            <text>The Department in accordance with Regulation .05 of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An individual living at the property; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The owner of the residential heating oil tank.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Homeowner Heating Oil Deliveries.</text>
          <paragraph num="(a)">
            <text>A homeowner may deliver heating oil to a residential heating oil tank owned by the homeowner.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A homeowner delivering heating oil to a residential heating oil tank owned by the homeowner shall:</text>
            <paragraph num="(i)">
              <text>Comply with §B(2)—(4) of this regulation; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Report a suspected or confirmed heating oil spill, release, or discharge to the Department in accordance with Regulation .05 of this chapter.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>New and Replacement Residential Heating Oil Tanks. A person installing a new or replacement residential heating oil tank aboveground, inside of a building, or underground shall comply with the following provisions:</text>
        <paragraph num="(1)">
          <text>Install a residential heating oil tank that meets the requirements of NFPA 31 “Standard for the Installation of Oil-Burning Equipment”;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Ensure all underground piping or piping in contact with the ground surface is protected from corrosion in accordance with:</text>
          <paragraph num="(a)">
            <text>NFPA 30 “Flammable and Combustible Liquids Code”; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>NFPA 31 “Standard for the Installation of Oil-Burning Equipment”;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Before installing a residential heating oil tank, obtain any applicable wetland and waterways authorization stated in Regulation .04E of this chapter;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>If installing an aboveground residential heating oil tank aboveground or inside of a building, install a storage tank that is:</text>
          <paragraph num="(a)">
            <text>UL listed for aboveground use or a storage tank designed and constructed for aboveground use in accordance with a Department-approved industry standard; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Placed on a foundation designed to minimize:</text>
            <paragraph num="(i)">
              <text>Uneven settling of the residential heating oil tank or the foundation; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Corrosion to any part of the residential heating oil tank resting on the foundation;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>If installing an aboveground residential heating oil tank in an area subject to flooding, anchor the residential heating oil tank securely to prevent:</text>
          <paragraph num="(a)">
            <text>The residential heating oil tank from floating; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A spill, release or discharge of heating oil from the residential heating oil tank; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>If installing an underground residential heating oil tank on or after June 13, 2022, install a storage tank that is:</text>
          <paragraph num="(a)">
            <text>UL listed for underground use or a storage tank designed and constructed for underground use in accordance with a Department-approved industry standard;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Constructed of corrosion protected steel or fiberglass reinforced plastic; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Protected from corrosion in accordance with:</text>
            <paragraph num="(i)">
              <text>NFPA 30 “Flammable and Combustible Liquids Code”; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>NFPA 31 “Standard for the Installation of Oil-Burning Equipment”.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Permanent Closure. A person shall complete all of the requirements of this section when permanently abandoning the use of heating oil as a fuel at a residential property or if removing a residential heating oil tank from a property.</text>
        <paragraph num="(1)">
          <text>Complete the permanent closure of a residential heating oil tank in accordance with PEI/RP1700-18 “Recommended Practices for the Closure of Underground Storage Tank and Shop-Fabricated Aboveground Storage Tank Systems”.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Complete the requirements listed in §D(3) or (4) of this regulation within 30 days of the determination that a residential heating oil tank will be permanently closed.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>When permanently closing a residential heating oil tank located aboveground or inside of a building:</text>
          <paragraph num="(a)">
            <text>Remove all flammable or combustible liquids from the storage tank and piping;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Dispose of all flammable and combustible liquids in accordance with federal, State, and local laws;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Remove the residential heating oil tank from the property;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Remove all piping and piping connections used for supplying heating oil between the storage tank and the heating system; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Remove all fill and vent pipes or fill the pipes with cement to prevent accidental filling.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>When permanently abandoning the use of heating oil as fuel, permanently close an underground residential heating oil tank in accordance with the closure requirements for UST systems in COMAR 26.10.10.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".14" heading="Marinas.">
      <paragraph num="A.">
        <text>This regulation does not apply to:</text>
        <paragraph num="(1)">
          <text>A marine oil facility;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An oil storage facility with loading and unloading facilities;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An oil storage facility or oil handling facility utilizing a flange-to-flange closed transfer piping system; or</text>
        </paragraph>
        <paragraph num="(4)">
          <text>A marine motor fuel dispensing facility where oil used as fuel is stored and dispensed only into fuel tanks of vessels of 300 gross tons or greater.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>If a marina is located in an area subject to flooding, an owner, an operator, and a person in charge of the marina shall ensure an AST and each dispenser at the marina used for fueling vessels or motor vehicles is anchored securely to prevent the AST or dispenser from floating and spilling, releasing, and discharging oil.</text>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of a new or replacement storage tank system used for fueling vessels at a marina shall:</text>
        <paragraph num="(1)">
          <text>Before beginning the installation of the storage tank system, obtain any applicable wetland and waterways authorization stated in Regulation .04E of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Comply with §E of this regulation;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Ensure the design and construction of a marina fueling system, including the piping system installed on a pier and connected to a dispenser, complies with the following standards:</text>
          <paragraph num="(a)">
            <text>NFPA 30 “Flammable and Combustible Liquids Code”;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>NFPA 30A “Code for Motor Fuel Dispensing Facilities and Repair Garages”; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>PEI/RP1000-14 “Recommended Practices for the Installation of Marina Fueling Systems”; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>At least 60 days prior to the start of installation, submit to the Department for review and approval the storage tank system engineering plans prepared by one or more of the following individuals:</text>
          <paragraph num="(a)">
            <text>A professional engineer;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An individual certified as a UST system technician in accordance with COMAR 26.10.06;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A certified inspector, as defined in COMAR 26.10.17.02B; or</text>
          </paragraph>
          <paragraph num="(d)">
            <text>An authorized inspector, as defined in COMAR 26.10.18.02B.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>An owner, an operator, and a person in charge of an oil storage tank system installed before June 13, 2022 that is used for fueling vessels at a marina shall comply with §E of this regulation not later than:</text>
        <paragraph num="(1)">
          <text>3 years after June 13, 2022; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Another time period approved by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Marina Fueling System Requirements. An owner, an operator, and a person in charge of an oil storage tank system used for fueling vessels at a marina shall ensure a marina fueling system satisfies all of the following requirements:</text>
        <paragraph num="(1)">
          <text>A readily accessible shut-off ball valve for each pipe conveying oil from a storage tank to a dispenser on a fueling pier is:</text>
          <paragraph num="(a)">
            <text>Located on-shore and near to the approach to the fueling pier;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Located outside of any secondary containment area;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Grouped in one location;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>In a waterproof containment sump that is not locked or bolted closed; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Identified by a sign stating “EMERGENCY FUEL SHUTOFF VALVE” in 2-inch minimum red capital letters;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The electrical components of a marina fueling system:</text>
          <paragraph num="(a)">
            <text>Are installed in accordance with NFPA 70 “National Electrical Code”; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Include emergency shut-off switches:</text>
            <paragraph num="(i)">
              <text>That are interlocked to shut off power to all pump motors, fuel dispensing devices, solenoid valves, and electrical circuits in classified areas from any individual location and manually reset only from a master switch;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Located on land within 10 feet of the bulkhead and near to the approach to a fueling pier;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Located on a fueling pier at least 20 feet and not further than 100 feet from a dispenser; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Identified by a sign stating “EMERGENCY PUMP SHUTOFF” in 2-inch minimum red capital letters;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>The fuel dispensing system, including each dispenser, dispenser hose and nozzle, at the marina:</text>
          <paragraph num="(a)">
            <text>Is UL listed or approved for the fuel being dispensed;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Is compatible with the product piping;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Has a containment sump that does not leak; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Has a UL listed shear valve placed and properly anchored at the dispenser in accordance with manufacturer requirements;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Each fuel delivery nozzle on a dispenser used for fueling vessels is an automatic-closing type without a latch-open device;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>One or more signs are posted in the dispensing area that provide instructions to the public on vessel fueling procedures in accordance with Section 11.10.8 of NFPA 30A “Code for Motor Fuel Dispensing Facilities and Repair Garages”;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>If the hose length of a dispenser hose is greater than 18 feet, the dispenser hose is secured by a hose reel;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Underground piping:</text>
          <paragraph num="(a)">
            <text>Between an AST and the bulkhead complies with COMAR 26.10.03.02 and 26.10.05.01 and .02; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>May be used between the bulkhead and the dispenser only if the underground piping has UL listed flexible double-walled construction:</text>
            <paragraph num="(i)">
              <text>Rated for aboveground, overwater, or underwater use by the piping manufacturer; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Not rated for aboveground, overwater, or underwater use by the piping manufacturer, but the piping is sleeved in rigid, corrosion-resistant pipe meeting a minimum 2-hour fire rating; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(8)">
          <text>The transition piping between the bulkhead and a floating pier:</text>
          <paragraph num="(a)">
            <text>Includes:</text>
            <paragraph num="(i)">
              <text>A reducing seal at the bulkhead;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Non-corrosive pipe supports;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>An in-line breakaway that seals both ends of the piping;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Single plane swivel joints with flanged fittings; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Fire-rated flex connectors; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Connects to the floating pier piping in a leak-proof containment sump with:</text>
            <paragraph num="(i)">
              <text>A manual ball valve in the product line;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A solenoid valve that is closed when the emergency pump shutoff is activated or when no fueling is occurring; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A sump sensor that triggers a positive system shutdown.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>An owner, an operator, and a person in charge of a marina shall:</text>
        <paragraph num="(1)">
          <text>Provide an attendant during vessel fueling activities and the attendant shall:</text>
          <paragraph num="(a)">
            <text>Be familiar with the dispensing systems and emergency shutoff controls;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Prevent the dispensing of oil into improper portable containers;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Ensure vessels are properly moored and all fueling connections are made;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Be within 15 feet of the dispensing controls during a fueling operation; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Maintain a direct, clear, and unobstructed view of both the vessel fuel filler neck and the emergency pump shutoff; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Provide a spill response box near to a fuel dispensing area that:</text>
          <paragraph num="(a)">
            <text>Stores a sufficient quantity of sorbent materials that can float on water to contain a minimum of 25 gallons of oil; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The person in charge of the marina inspects monthly to ensure supplies of sorbent materials are maintained.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".15" heading="Solidification/Stabilization of Oil Waste Materials.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility shall obtain an Individual Oil Operations Permit to conduct an oil sludge, oil refuse, or oil mixed with other waste solidification/stabilization operation.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Permit Application and Issuance Procedures.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility shall apply for an Individual Oil Operations Permit in accordance with Regulations .09A and .11 of this chapter, and include the following information in the permit application:</text>
          <paragraph num="(a)">
            <text>A to-scale site diagram that identifies the:</text>
            <paragraph num="(i)">
              <text>Location of each solidification/stabilization process area;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Direction of stormwater flow at the facility;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Storm drains on-site and immediately off-site; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Location of buildings and property lines, identifying the owners of any adjacent properties; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>A detailed description of:</text>
            <paragraph num="(i)">
              <text>The solidification/stabilization process;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The testing or verification to be completed prior to accepting oil sludge, oil refuse, or oil mixed with other waste intended for solidification/stabilization to ensure the oil sludge, oil refuse, or oil mixed with other waste does not contain a hazardous substance or originate from a gasoline storage tank system; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>How the facility will maintain records of tracking and testing for each batch of raw material to be solidified/stabilized and for loads of processed material transferred to a permitted disposal facility.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Upon review of an application completed in accordance with this regulation, the Department shall:</text>
          <paragraph num="(a)">
            <text>Notify the applicant in writing that the application is not complete and additional information is required to determine whether the proposed oil solidification/stabilization operation is consistent with all applicable requirements of this chapter, COMAR 26.10, and other State laws and regulations;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Issue an Individual Oil Operations Permit to the applicant in accordance with Regulation .11G and H of this chapter; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Deny the application for an Individual Oil Operations Permit in accordance with Regulation .12 of this chapter.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility shall apply to renew an Individual Oil Operations Permit in accordance with §B(1) of this regulation and Regulation .11E of this chapter.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>In accordance with Regulation .12B of this chapter, the Department may:</text>
          <paragraph num="(a)">
            <text>Deny an application for an Individual Oil Operations Permit for a proposed oil solidification/stabilization operation; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Suspend or revoke an Individual Oil Operations Permit under which an oil solidification/stabilization operation is permitted.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>The Department may modify, or an owner, an operator, and a person in charge of an oil storage facility or oil handling facility may request to modify, the oil solidification/stabilization conditions of an Individual Oil Operations Permit in accordance with Regulation .12B of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Operation and Recordkeeping Conditions. An owner, an operator, and a person in charge of an oil storage facility or oil handling facility conducting an oil solidification/stabilization operation:</text>
        <paragraph num="(1)">
          <text>May not accept oil sludge, oil refuse, or oil mixed with other waste that contains:</text>
          <paragraph num="(a)">
            <text>A hazardous substance; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Sludge, refuse, or other mixed waste from a gasoline storage tank system;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>May not cause or allow the unpermitted discharge of stormwater entering the solidification/stabilization process area into waters of the State;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Shall ensure stormwater entering the solidification/stabilization process area is either:</text>
          <paragraph num="(a)">
            <text>Included in the solidification/stabilization process;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Managed under a State discharge permit or National Pollutant Discharge Elimination System permit; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Disposed of at a facility permitted for the treatment of oily water;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Shall complete the following tasks at the end of each working day:</text>
          <paragraph num="(a)">
            <text>Clean the area surrounding the solidification/stabilization area of all oily substances; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Cover and secure the solidification/stabilization process area so that the contents are not exposed to stormwater;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Shall dispose of the end product from the solidification/stabilization process at a State or USEPA permitted disposal facility;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Shall maintain the following records for at least 5 years at the oil storage facility or oil handling facility:</text>
          <paragraph num="(a)">
            <text>Certification by a generator of oil sludge, oil refuse, or oil mixed with other waste that the material is in compliance with §C(1) of this regulation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Analytical data demonstrating the oil sludge, oil refuse, or oil mixed with other waste accepted at the oil storage facility or oil handling facility is in compliance with §C(1) of this regulation; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A copy of each approval from the receiving facility where the oil solidification/stabilization end product was accepted and disposed, including analytical data; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>In addition to the requirements under §C(1)—(6) of this regulation, shall comply with the Individual Oil Operations Permit conditions under Regulation .09A of this chapter.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".16" heading="Requirements for Oil Delivery by Truck Tanks and Transports.">
      <paragraph num="A.">
        <text>A permittee and a person in charge of the transportation, transfer, or delivery of oil shall use:</text>
        <paragraph num="(1)">
          <text>A truck tank or transport equipped with transfer hoses and fittings of a grade suitable for the type of oil transferred and for the type of delivery;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A truck tank or transport equipped with transfer hoses designed to withstand pressure of the shut-off head of the cargo pump or pump relief valve setting; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Vehicles that are in compliance with:</text>
          <paragraph num="(a)">
            <text>The Maryland Department of Transportation requirements for transportation of hazardous materials under COMAR 11.16.01 and motor carrier safety under COMAR 11.21.01; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>NFPA 385 “Standard for Tank Vehicles for Flammable and Combustible Liquids”.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>A permittee and a person in charge of the transportation, transfer, or delivery of oil by truck tank or transport shall:</text>
        <paragraph num="(1)">
          <text>Provide a driver safety training program annually that instructs drivers employed by the permittee or the person in charge on:</text>
          <paragraph num="(a)">
            <text>Truck tank, transport, and oil delivery operations;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The oil pollution control and storage tank system provisions in COMAR 26.10.01—26.10.04, 26.10.17, and 26.10.18;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The requirement for the reporting, containment, and removal of an oil spill, release, or discharge; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The conditions of the permittee’s Individual Oil Operations Permit;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Ensure a driver employed by the permittee or the person in charge is knowledgeable of and follows the requirements under Regulation .17 of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Maintain records demonstrating compliance with the training requirement under §B(1) of this regulation;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Within 30 days of hire, provide a truck tank or transport driver with safety training in accordance with §B(1) of this regulation;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Provide each truck tank or transport with:</text>
          <paragraph num="(a)">
            <text>Materials to be used for the prompt containment and removal of an oil spill, release, or discharge; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>One portable fire extinguisher that has a minimum rating of 4-A:40-B:C, or at least two portable fire extinguishers with a rating of 2-A:20-B:C;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>Ensure the Department’s emergency spill reporting telephone number listed in the Individual Oil Operations Permit is conspicuously posted in each truck tank and transport authorized under the permit for the transportation, transfer, or delivery of oil;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Meet insurance requirements for the transportation, transfer, and delivery of oil;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>On an annual basis or at least every 25,000 miles, perform preventative maintenance on a truck tank or transport in accordance with 49 CFR Part 396 and COMAR 11.14;</text>
        </paragraph>
        <paragraph num="(9)">
          <text>Inspect and test each truck tank and transport used for the transportation of flammable petroleum liquids in accordance with 49 CFR §180.407;</text>
        </paragraph>
        <paragraph num="(10)">
          <text>Obtain and properly display a:</text>
          <paragraph num="(a)">
            <text>U.S. Department of Transportation number for each interstate truck tank or transport the permittee or the person in charge uses in the transportation, transfer, or delivery of oil; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Maryland State Highway Administration identification number for each intrastate truck tank or transport the permittee or the person in charge uses in the transportation, transfer, or delivery of oil;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(11)">
          <text>Register each placarded truck tank or transport in accordance with 49 CFR Part 107; and</text>
        </paragraph>
        <paragraph num="(12)">
          <text>Meet zoning requirements for commercial vehicles when parking a truck tank or transport in the State.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>A permittee and a person in charge may not deliver oil by truck tank or transport to:</text>
        <paragraph num="(1)">
          <text>A UST system that is not registered with the Department in accordance with COMAR 26.10.03.09;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An AST system that is not registered with the Department in accordance with Regulation .10 of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An oil storage tank in which the Department has:</text>
          <paragraph num="(a)">
            <text>In accordance with COMAR 26.10.02.03C, issued a notice of a delivery ban to the owner, the operator, and the person in charge of the oil storage tank system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Affixed a monitoring device, such as a tag, notice, or locking mechanism, to the fill; or</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>A storage tank system or a residential heating oil tank that is:</text>
          <paragraph num="(a)">
            <text>Visibly spilling or releasing oil;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In poor or damaged condition; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>In an unstable condition.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>A person may not fuel or refuel a vessel from a truck tank or transport at a public marina.</text>
      </paragraph>
      <paragraph num="E.">
        <text>Class II liquid from a truck tank or transport may be dispensed to a vessel located at a commercial, industrial, government, or manufacturing facility if the following requirements are met:</text>
        <paragraph num="(1)">
          <text>The vessel is used in connection with the facility’s business;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The owner, the operator, and the person in charge of the facility controls access to the fueling or refueling area, with the fueling or refueling area not accessible to the general public;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The dispensing hose does not exceed 50 feet in length;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The dispensing nozzle is a UL listed, automatic-closing type without a latch-open device;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>A nighttime delivery only occurs in an area that is adequately lighted;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>The driver or the person in charge at the facility ensures the flasher lights of the truck tank or transport are in operation during all fueling and refueling activities;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>The driver ensures there is adequate fuel expansion space left in each fuel tank of the vessel being filled to prevent a spill, release, or discharge because of temperature increase; and</text>
        </paragraph>
        <paragraph num="(8)">
          <text>The owner, the operator, and the person in charge of a facility where the oil is delivered by truck tank or transport to a vessel:</text>
          <paragraph num="(a)">
            <text>Maintains sufficient spill containment materials for a spill, release, or discharge of, at a minimum, 100 gallons of oil on land or in waters of the State; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Locates the spill containment materials in an easily identifiable area near to where fueling operations occur.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".17" heading="Requirements for Drivers of Truck Tanks and Transports.">
      <paragraph num="A.">
        <text>A driver operating a truck tank or a transport shall:</text>
        <paragraph num="(1)">
          <text>Comply with NFPA 385 “Standard for Tank Vehicles for Flammable and Combustible Liquids”;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Be 21 years old or older as required under Transportation Article, §25-111, Annotated Code of Maryland; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Complete annual safety training provided in accordance with Regulation .16B of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>A driver shall load and unload a truck tank or transport only in an approved location.</text>
      </paragraph>
      <paragraph num="C.">
        <text>A driver may not deliver to a storage tank, including a residential heating oil tank, when any of the following conditions are observed:</text>
        <paragraph num="(1)">
          <text>The Department has:</text>
          <paragraph num="(a)">
            <text>In accordance with COMAR 26.10.02.03C, issued a notice of a delivery ban to the owner, the operator, and the person in charge of the oil storage tank system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Affixed a monitoring device, such as a tag, notice, or locking mechanism, to the fill;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The storage tank system is visibly spilling or releasing oil; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An AST system is in poor, unstable, or damaged condition.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Before a transfer of oil begins, the driver shall:</text>
        <paragraph num="(1)">
          <text>Verify that:</text>
          <paragraph num="(a)">
            <text>Proper hoses and fittings will be used in the delivery of oil;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The transfer hoses are not damaged; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>All transfer hose connections are tight; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Confirm, for direct or remote filling operations, the storage tank has sufficient ullage available to hold the amount of oil being delivered by implementing one or more of the following methods:</text>
          <paragraph num="(a)">
            <text>Gauge the storage tank and record ullage and amount of oil delivered;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Use a functioning vent whistle or other overfill device;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Verify with the facility’s person in charge:</text>
            <paragraph num="(i)">
              <text>The size of the storage tank being delivered to and the quantity of oil to be delivered;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>That the storage tank has an approved and functional overfill alarm; or</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>For remote filling, that a representative from the facility will actively participate in the filling operation; or</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>Use another method approved by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>During a transfer of oil, the driver shall:</text>
        <paragraph num="(1)">
          <text>Be alert and outside the vehicle;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Remain within 10 feet and in full and immediate control of the nozzle, shut-off valves, pumps, and emergency operating mechanism for the discharge control valve; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Have the fill pipe opening in full view at all times.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>If a driver leaves the equipment unattended for any reason, the driver shall turn off or return to the closed position all nozzles, shut-off valves, pumps, and discharge control valves of the truck tank or transport and the receiving facility.</text>
      </paragraph>
      <paragraph num="G.">
        <text>A driver may not drain oil or empty hoses into a spill catchment basin.</text>
      </paragraph>
      <paragraph num="H.">
        <text>A driver shall immediately report to the delivery company any unusual conditions observed during a transfer operation including, but not limited to:</text>
        <paragraph num="(1)">
          <text>A spill, release, or discharge;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A discrepancy between the quantity of oil delivered and the quantity of oil received;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Equipment defects on the delivery vehicle or at a transfer location; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Unsafe delivery conditions.</text>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>A driver, permittee, and person in charge of a delivery company shall report a spill, release, or discharge made during an oil delivery in accordance with Regulation .05 of this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".18" heading="Requirements for Oil Transfers at Facilities.">
      <paragraph num="A.">
        <text>The requirements of this regulation are applicable to oil storage facilities and oil handling facilities with tank car, truck tank, or transport loading/unloading racks or transfer areas.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Spill Control.</text>
        <paragraph num="(1)">
          <text>For a loading/unloading rack or transfer area at an oil storage facility or oil handling facility where a spill, release, or discharge can occur during transfer operations, an owner, an operator, and a person in charge of the facility shall:</text>
          <paragraph num="(a)">
            <text>Pave the loading/unloading rack or transfer area with a material that has a permeability of 10-7 centimeters/second or less and is resistant to oil;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Maintain the pavement installed in accordance with §B(1)(a) of this regulation to prevent cracking and holes;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Design the loading/unloading rack or transfer area to prevent the entrance of stormwater or wastewater runoff into the loading/unloading rack or transfer area;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Cover the loading/unloading rack or transfer area with a roof;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Include a containment system that prevents oil or stormwater containing oil from discharging to waters of the State by:</text>
            <paragraph num="(i)">
              <text>Being designed to hold a spill, release, or discharge from the largest single compartment of any tank car, truck tank, or transport loading or unloading oil at the facility; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Using permanent curbing, trenching, or other spill control methods approved by the Department; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(f)">
            <text>Install one or more of the following to prevent a spill, release, or discharge of oil:</text>
            <paragraph num="(i)">
              <text>An oil/water separator;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A diked or bermed catchment area that has a permeability of 10-7 centimeters/second or less; or</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>An emergency underground holding tank that remains empty unless a spill, release, or discharge occurs.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner of an oil storage facility or oil handling facility with a loading/unloading rack or transfer area may be required to obtain a State discharge permit or a National Pollutant Discharge Elimination System permit issued by the Department under Environment Article, §9-323, Annotated Code of Maryland and COMAR 26.08.01—26.08.04 for discharges of stormwater to waters of the State.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If oil is spilled, released, or discharged during an oil transfer, an owner, an operator, and a person in charge of an oil storage facility or oil handling facility shall:</text>
          <paragraph num="(a)">
            <text>Report the spill, release, or discharge immediately to the Department in accordance with Regulation .05 of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Immediately begin the removal of oil; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Handle the oil and all removal debris in accordance with all State, federal, and local requirements.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner, an operator, and a person in charge of an oil storage facility or oil handling facility shall make available at a loading/unloading rack or transfer area removal materials, such as sorbents:</text>
          <paragraph num="(a)">
            <text>That are appropriate for:</text>
            <paragraph num="(i)">
              <text>The grades of oil being transferred; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The most probable size of an anticipated spill, release, or discharge; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>For use in the containment and removal of spilled, released, or discharged oil.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Transfer Operations. An owner, an operator, and a person in charge of an oil storage facility or oil handling facility shall:</text>
        <paragraph num="(1)">
          <text>Install a clearly identifiable switch or shutoff at the loading/unloading rack and at a remote location from the loading/unloading rack area to shut off power to all transfer devices in the event of an emergency;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Provide an interlocking warning light or physical barrier system, warning signs, wheel chocks, or vehicle brake interlock system to prevent a tank car, truck tank, or transport from leaving a loading/unloading area or transfer area before flexible or fixed oil transfer lines are disconnected;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Prior to filling and departure at the oil storage facility or oil handling facility, inspect the lowermost drain and all outlets on the tank car, truck tank, or transport for spills, releases, or discharges; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>If a spill, release, or discharge is found during an inspection, repair or replace the lowermost drain and all outlets on the tank car, truck tank, or transport prior to entering a public transportation system.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".19" heading="Right to Information and Facility Access.">
      <text>As a condition for the issuance of an Individual Oil Operations Permit or authorization to operate under a General Oil Operations Permit, the permittee and the person in charge of an oil storage facility or oil handling facility shall, upon the request of the Department:</text>
      <paragraph num="A.">
        <text>Provide to the Department information and copies of records required under:</text>
        <paragraph num="(1)">
          <text>The provisions of COMAR 26.10;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Environment Article, §§4-401—4-420, Annotated Code of Maryland; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A condition of the permit;</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Allow the Department to conduct monitoring;</text>
      </paragraph>
      <paragraph num="C.">
        <text>Complete any survey forms or other documents provided by the Department in a timely manner;</text>
      </paragraph>
      <paragraph num="D.">
        <text>Make the facility available for inspection by the Secretary or the Secretary’s authorized representative, including the inspection of storage tank systems, equipment, vehicles, or vessels used in the operation of the oil storage facility or oil handling facility; and</text>
      </paragraph>
      <paragraph num="E.">
        <text>During an inspection of the facility:</text>
        <paragraph num="(1)">
          <text>Make all records pertaining to the facility and the operation of the facility available for inspection;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Allow the Department to:</text>
          <paragraph num="(a)">
            <text>Make copies of data, records, and information pertaining to the facility and the operation of the facility;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Collect air, surface or groundwater, soil, and vegetation samples or samples of other materials on-site as determined necessary by the Department; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Obtain photographic or videographic documentation or evidence.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".20" heading="Requirements for Motor Fuel Dispensing Facilities.">
      <paragraph num="A.">
        <text>The requirements of this regulation apply to an owner, an operator, and a person in charge of a motor fuel dispensing facility.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of a motor fuel dispensing facility shall install and operate a storage tank system in accordance with the requirements of COMAR 26.10 as follows:</text>
        <paragraph num="(1)">
          <text>Install and operate a UST system in accordance with:</text>
          <paragraph num="(a)">
            <text>The requirements of this chapter, COMAR 26.10.02—26.10.12, and 26.10.16; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The applicable documents incorporated by reference under Regulation .03 of this chapter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Install and operate an AST system in accordance with:</text>
          <paragraph num="(a)">
            <text>The requirements of this chapter and COMAR 26.10.17 and 26.10.18; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The applicable documents incorporated by reference under Regulation .03 of this chapter; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>If the motor fuel dispensing facility is located at a marina, comply with the requirements of Regulation .14 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of a motor fuel dispensing facility may not allow the dispensing of motor fuel at the facility unless:</text>
        <paragraph num="(1)">
          <text>The location is attended;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The owner, the operator, and the person in charge has received prior written approval from the Department to operate the location as an unattended motor fuel dispensing facility; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The location is a commercial, industrial, governmental, or manufacturing property where motor fuels are dispensed into the fuel tanks of motor vehicles or vessels that are:</text>
          <paragraph num="(a)">
            <text>Owned or controlled by the owner, the operator, and the person in charge of the facility; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Used in connection with the business or operation of that property by persons within the employ of such business or operation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>The Department may not provide written approval to an owner, an operator, and a person in charge of a marina with a motor fuel dispensing facility to operate the motor fuel dispensing facility unattended.</text>
      </paragraph>
      <paragraph num="E.">
        <text>Pursuant to §C(2) of this regulation, the Department may provide written approval to an owner, an operator, and a person in charge of a motor fuel dispensing facility to operate the location unattended if the owner, the operator, and the person in charge of the facility:</text>
        <paragraph num="(1)">
          <text>Provide each customer with a unique means of authorization, such as a key card, membership card, or other method that identifies the specific customer;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Ensure the dispensers at the facility require a customer to input the unique authorization required under §E(1) of this regulation in order for motor fuel to be dispensed;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Install an emergency shut-off device or electrical disconnect that is readily accessible to customers for each group of dispensers on an individual dispenser island;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Confirm with the State Fire Marshall or local fire department whether the owner, the operator, and the person in charge of the motor fuel dispensing facility needs to employ additional fire protections such as:</text>
          <paragraph num="(a)">
            <text>Installing fixed suppression systems, automatic fire detection systems, or manual fire alarm stations;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Transmitting alarms to an off-site supervising fire alarm station located at the oil storage facility or another off-site location; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Limiting the quantity of motor fuel dispensed per transaction;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Provide the Department with documentation that confirms the installation of any additional fire protection methods at the facility under the direction of the State Fire Marshall or local fire department, as required under §E(4) of this regulation;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Conspicuously post operating instructions, warning signs, and emergency instructions in the dispensing area in accordance with NFPA 30A “Code for Motor Fuel Dispensing Facilities and Repair Garages”;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Provide on-site in a readily accessible location a telephone or other approved clearly identifiable means to notify the fire department in accordance with NFPA 30A “Code for Motor Fuel Dispensing Facilities and Repair Garages”;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>On a sign visible from the dispensing area that is not less than 8 x 10 inches in size with lettering not less than 1-inch high, conspicuously post emergency telephone numbers for contacting the following persons in the event of a suspected or confirmed spill, release or discharge, unusual operating conditions, emergency, or equipment failure:</text>
          <paragraph num="(a)">
            <text>Emergency response authorities;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A person in charge at the facility; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The Department;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(9)">
          <text>Provide at least one readily available spill containment kit clearly labeled and stored on-site to contain spills, releases, or discharges of less than 20 gallons; and</text>
        </paragraph>
        <paragraph num="(10)">
          <text>If the facility is a regulated substance storage facility, comply with the operator training requirements for designated Class A operators, Class B operators, and Class C operators of unattended facilities in accordance with COMAR 26.10.16.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>If the Department determines that an owner, an operator, and a person in charge of an approved unattended motor fuel dispensing facility is not maintaining the operations of the facility in accordance with §E of this regulation, the Department may:</text>
        <paragraph num="(1)">
          <text>For a UST system, issue a notice of a delivery ban in accordance with COMAR 26.10.02.03C; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>For an AST system, suspend or revoke an Individual or General Oil Operations Permit in accordance with Regulation .12 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>An owner, an operator, and a person in charge of a motor fuel dispensing facility with a sanitary sewer or storm drain connection receiving oil-bearing waste or wastewater from operations at the motor fuel dispensing facility shall:</text>
        <paragraph num="(1)">
          <text>Comply with one of the following requirements:</text>
          <paragraph num="(a)">
            <text>If oil-bearing waste or wastewater enters a publicly-owned wastewater treatment system, obtain and operate under a Pretreatment Permit issued by:</text>
            <paragraph num="(i)">
              <text>The local municipal wastewater treatment utility with delegated authority by the Department to administer a Pretreatment Program in accordance with COMAR 26.08.08; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The Department if the local municipal wastewater treatment utility does not have delegated authority to administer a Pretreatment Program; or</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>If oil-bearing waste or wastewater enter into a storm drain system, install an oil/water separating system that is properly:</text>
            <paragraph num="(i)">
              <text>Designed to accommodate a worst case incident of a spill, release, or discharge;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Operated by a person in charge of the motor fuel dispensing facility;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Maintained to manufacturer specifications;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Inspected monthly; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Pumped out when oil has accumulated to greater than 1 inch in the retention chamber; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Obtain all the required permits for the sanitary sewer or storm drain connection receiving oil-bearing waste or wastewater from operations at the motor fuel dispensing facility in accordance with federal, State and local laws and regulations.</text>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>A person in charge of a motor fuel dispensing facility shall dispose of used oil generated at the motor fuel dispensing facility:</text>
        <paragraph num="(1)">
          <text>In accordance with COMAR 26.10.15;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In a manner that prevents a spill, release, or discharge; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Using disposal methods required under applicable federal, State and local laws and regulations.</text>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>An owner, an operator, and a person in charge of a motor fuel dispenser facility may not install or use a dispenser hose that is greater than 18 feet in length.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".21" heading="Requirements for Marine Oil Facilities.">
      <paragraph num="A.">
        <text>Response Plan.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a marine oil facility required to have an approved response plan under 33 CFR Part 154, Subpart F may not operate the marine oil facility unless the owner, the operator, and the marine oil facility are in full compliance with federal requirements for a response plan.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a marine oil facility shall include in a response plan, at a minimum:</text>
          <paragraph num="(a)">
            <text>Training elements;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Oil spill, release, or discharge contingency elements;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Removal equipment elements; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>All of the elements required to be included in a response plan under 33 CFR Part 154, Subpart F.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner and an operator of a marine oil facility shall provide to the Department a current response plan as part of an application for:</text>
          <paragraph num="(a)">
            <text>A new Individual Oil Operations Permit; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A renewal of an Individual Oil Operations Permit.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner and an operator of a marine oil facility shall implement all of the elements of an approved response plan in accordance with the schedule of compliance in 33 CFR Part 154, Subpart F.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>An owner and an operator of a marine oil facility shall:</text>
          <paragraph num="(a)">
            <text>Maintain an approved response plan at the marine oil facility; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Make the approved response plan available for review upon request by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Spill, Release, and Discharge Prevention at Marine Oil Facilities.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a marine oil facility shall institute safe fill and shutdown procedures to prevent oil spills, releases, or discharges:</text>
          <paragraph num="(a)">
            <text>During an oil transfer operation; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In the event of an overfill of a storage tank.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a marine oil facility shall include in the procedures required under §B(1) of this regulation, at a minimum, the following elements:</text>
          <paragraph num="(a)">
            <text>Prior to commencing an oil transfer operation, an owner, an operator, and a person in charge of the marine oil facility confirms that the volume available in the receiving storage tank is greater than the volume of oil to be transferred;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The continuous monitoring of an oil transfer operation by manual or automatic means until the transfer of oil is complete;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A storage tank fill valve not in use during an oil transfer operation is closed and secured; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The transfer of oil only occurs into a storage tank designated to receive the oil.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Shutdown System or Alarm.</text>
          <paragraph num="(a)">
            <text>Storage tanks receiving asphalt (CAS8052424) from a tank vessel are exempt from the requirements of §B(3) of this regulation.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An owner and an operator of a marine oil facility shall:</text>
            <paragraph num="(i)">
              <text>Install an automatic shutdown system on each storage tank to be used during the transfer of oil from a tank vessel that will, in the event of an overfill, direct the flow of oil to another storage tank capable of receiving the oil or shut down the pumping system; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Equip each AST used in the transfer of oil from a tank vessel with a high level alarm.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>If an AST is equipped with a high level alarm in accordance with §B(3)(b)(ii) of this regulation, an owner and an operator of a marine oil facility shall install a high level alarm that:</text>
            <paragraph num="(i)">
              <text>Consists of a device capable of visually and audibly alerting the owner and the operator of the marine oil facility of an impending storage tank overfill; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If a failure, malfunction, or power loss occurs during the transfer of oil, causes a warning light and audible signal to activate at a location in which the owner and the operator of the marine oil facility monitors or controls oil transfers at the facility.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>If a high level alarm sounds, an owner and an operator of a marine oil facility shall initiate an immediate and orderly emergency shutdown of the oil transfer.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>An owner and an operator of a marine oil facility using a high level alarm shall include an emergency shutdown procedure in the facility records and ensure that all facility personnel involved in the transfer operation are trained in the emergency shutdown procedure.</text>
        </paragraph>
        <paragraph num="(6)">
          <text>An owner and an operator of a marine oil facility shall ensure that an automatic shutdown system or high level alarm system is tested:</text>
          <paragraph num="(a)">
            <text>Monthly; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Before a receipt of oil.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>An owner and an operator of a marine oil facility shall:</text>
          <paragraph num="(a)">
            <text>Maintain records of testing at the marine oil facility; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Make the records of testing available for review by a representative of the Department upon request.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".22" heading="Requirements for Tank Vessels.">
      <paragraph num="A.">
        <text>Response Plan.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a tank vessel shall comply with the requirements of §A(2)—(4) of this regulation.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a tank vessel required to have an approved response plan under 33 CFR Part 155, Subpart D may not operate the tank vessel in the State unless the owner and the operator of the tank vessel and the tank vessel are in full compliance with federal requirements for a response plan.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner and an operator of a tank vessel shall include in a response plan, at a minimum:</text>
          <paragraph num="(a)">
            <text>Training elements;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Oil spill, release, or discharge contingency elements;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Removal equipment elements; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>All of the elements required to be included in a response plan under 33 CFR Part 155, Subpart D.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner and an operator of a tank vessel shall make an approved response plan available for review by a representative of the Department upon request.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Detection and Control of Oil Spills, Releases, and Discharges.</text>
        <paragraph num="(1)">
          <text>All-weather Escort Tank Vessel.</text>
          <paragraph num="(a)">
            <text>The requirements of §B(1) and (2) of this regulation do not apply to a public vessel.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An owner and an operator of a tank vessel shall ensure that a tank vessel transporting oil in the State is accompanied by an all-weather escort vessel.</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The crew on an escort vessel shall continuously check for any evidence of an oil spill, release, or discharge from the escorted tank vessel.</text>
          </paragraph>
          <paragraph num="(d)">
            <text>A vessel supplying propulsion to the tank vessel does not fulfill the requirement for an all-weather escort vessel.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Alternative Monitoring. In lieu of meeting the escort vessel requirement under §B(1) of this regulation, an owner and an operator of a tank vessel may:</text>
          <paragraph num="(a)">
            <text>Equip the tank vessel with a cargo level monitoring system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Ensure the tank vessel’s double hulls are designed in compliance with 33 CFR §157.10(d); or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Have a Department approved plan prepared by the owner and the operator of the tank vessel that provides for visual or another method of inspection of load lines or draft markings for the tank vessel that will determine the existence of an oil spill, release, or discharge from the tank vessel.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Cargo Level Monitoring System. An owner and an operator of a tank vessel shall:</text>
          <paragraph num="(a)">
            <text>Maintain the cargo level monitoring system of the tank vessel in full working order; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Correct a malfunction of equipment before getting the tank vessel underway.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Inspection Requirements.</text>
        <paragraph num="(1)">
          <text>The requirements of this section do not apply to a public vessel.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a tank vessel transporting oil in the State shall inspect the tank vessel in accordance with 46 U.S.C. Subtitle II, Part B and 46 CFR Part 2.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The Department may require an owner and an operator of a tank vessel to perform additional inspections if the Department has reason to believe the tank vessel has been damaged or responsible for one or more spills, releases, or discharges due to structural damage.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner and an operator of a tank vessel shall display a certificate of inspection issued under 46 U.S.C. Subtitle II, Part B and 46 CFR Part 2 in a conspicuous place on the tank vessel.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".23" heading="Bonding Requirements for Tank Vessels.">
      <paragraph num="A.">
        <text>The terms “assets”, “current assets”, “current liabilities”, “liabilities”, “net working capital”, “net worth”, “parent corporation”, and “tangible net worth” as used in §D of this regulation have the meanings stated in 40 CFR §264.141.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Exceptions.</text>
        <paragraph num="(1)">
          <text>The requirements of this regulation do not apply to a public vessel.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a tank vessel transferring greater than 25 barrels of oil in bulk as cargo in waters of the State may not be required to obtain a bond or other security for the tank vessel if:</text>
          <paragraph num="(a)">
            <text>The tank vessel is carrying oil removed from:</text>
            <paragraph num="(i)">
              <text>Waters of the State as the result of a spill, release, or discharge or at the request of the Department, the federal government, or a person responsible for the discharge; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Another vessel because of the threat of a spill, release, or discharge into waters of the State; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>The tank vessel is not owned or operated by the person responsible for the discharge resulting in the need for removal of oil from waters of the State.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Bonding Requirement. Upon entering waters of the State to transfer greater than 25 barrels of oil in bulk as cargo, an owner and an operator of a tank vessel shall post a bond or other security as set forth in §D of this regulation:</text>
        <paragraph num="(1)">
          <text>In the amount of $500 per gross ton of tank vessel; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In a form approved by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Other Acceptable Forms of Security. In lieu of posting a bond, an owner and an operator of a tank vessel may satisfy the requirement under §C of this regulation by posting another acceptable form of security that meets the conditions under §D(1) or (2) of this regulation:</text>
        <paragraph num="(1)">
          <text>A certification signed by a certified public accountant that the owner and the operator of the tank vessel has:</text>
          <paragraph num="(a)">
            <text>Two out of the three following ratios:</text>
            <paragraph num="(i)">
              <text>A ratio of total liabilities to net worth of less than 2.0;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A ratio of the sum of net income plus depreciation, depletion, and amortization to total liabilities of greater than 0.1; or</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A ratio of current assets to current liabilities of greater than 1.5;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Net working capital and tangible net worth that are individually at least six times the bond amount required under §C(1) of this regulation;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Tangible net worth of at least $10,000,000; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Assets located in the United States amounting to at least:</text>
            <paragraph num="(i)">
              <text>90 percent of total assets; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Six times the bond amount required under §C(1) of this regulation; or</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A certification signed by a certified public accountant that the owner and the operator of the tank vessel has:</text>
          <paragraph num="(a)">
            <text>A current rating for the most recent bond issuance of:</text>
            <paragraph num="(i)">
              <text>AAA, AA, A, or BBB as issued by the Standard and Poor’s (S&amp;P); or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Aaa, Aa, A, or Baa as issued by Moody’s;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>A parent corporation that meets the requirements of §D(1)(b)—(d) of this regulation; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>An absolute guaranty by the parent corporation of the owner and the operator of the tank vessel.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>An owner and an operator of a tank vessel may satisfy §C of this regulation by offering proof to the Department of a current Certificate of Financial Responsibility issued to the owner and the operator of the tank vessel by the USCG under 33 CFR Part 138 for each tank vessel of the owner and the operator entering waters of the State.</text>
      </paragraph>
      <paragraph num="F.">
        <text>The Department may waive the requirements of this regulation if the Department determines that the bonds or other securities required under this regulation are not generally available.</text>
      </paragraph>
      <paragraph num="G.">
        <text>Bond Forfeiture.</text>
        <paragraph num="(1)">
          <text>If the Department determines that a spill, release, or discharge into waters of the State originated from a tank vessel, the bond or other security posted by the owner and the operator of the tank vessel is forfeited and becomes due and payable to the Department to the extent of:</text>
          <paragraph num="(a)">
            <text>The costs incurred by the Department to eliminate the residue of the oil spill, release, or discharge;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Damage caused to the natural and recreational resources of the State; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Any uncollectible penalty levied against the owner and the operator of the tank vessel; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>If a bond or other security is forfeited to the Department as described in §G(1) of this regulation, an owner and an operator of a tank vessel shall post a new bond or other security for the tank vessel in accordance with §C of this regulation.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".24" heading="Violations.">
      <paragraph num="A.">
        <text>As authorized under Environment Article, §4-412, Annotated Code of Maryland:</text>
        <paragraph num="(1)">
          <text>The Department shall issue and cause to be served a written complaint:</text>
          <paragraph num="(a)">
            <text>To an alleged violator of a provision of Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland or of any oil pollution control and storage tank management provision of COMAR 26.10; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>That specifies the following information:</text>
            <paragraph num="(i)">
              <text>The provision of law, rule, or regulation allegedly violated; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The alleged fact or facts that constitute the violation;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Subsequent to or concurrent with the service of the complaint authorized under §A(1) of this regulation, the Department may issue to an alleged violator:</text>
          <paragraph num="(a)">
            <text>An order requiring the alleged violator take necessary corrective action within the time prescribed in the order;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A notice requiring an alleged violator file a written report with the Department regarding the alleged violation;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A notice requiring the alleged violator to appear before the Department at a time and place the Department specifies to answer the charge outlined in the complaint; or</text>
          </paragraph>
          <paragraph num="(d)">
            <text>A notice requiring the alleged violator file a written report with the Department regarding the alleged violation and appear before the Department at a time and place the Department specifies to answer the charges outlined in the complaint; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>If the Department exercises one of the options provided under §A(2)(b)—(d) of this regulation, the Department:</text>
          <paragraph num="(a)">
            <text>May not issue an order to the alleged violator that requires corrective action be taken as a result of the alleged violation before expiration of the time set for filing a written report and for holding a hearing required under §A(2)(b)—(d) of this regulation; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>May issue an order requiring corrective action be taken within the time prescribed in the order, after the expiration of the time set for filing the written report and holding the hearing required under §A(2)(b)—(d) of this regulation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Contested Case Hearing.</text>
        <paragraph num="(1)">
          <text>Filing a Hearing Request. A person shall have an opportunity for a contested case hearing if the person files a written request with the Department not later than 10 calendar days after being served with:</text>
          <paragraph num="(a)">
            <text>An order from the Department requiring a corrective action issued under §A(2)(a) of this regulation; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A notice from the Department requiring the person to file a written report regarding an alleged violation issued under §A(2)(b) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The appearance of the alleged violator before the Department in accordance with §A(2)(c) or (d) of this regulation constitutes an administrative hearing, and the party shall have the rights of any party in a contested case provided under State Government Article, §§10-205, 10-208 and 10-209, Annotated Code of Maryland.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A person issued an order provided under §A(3)(b) of this regulation may not request a hearing as a result of the order.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Notwithstanding a person’s right to a contested case hearing, an order issued to a person pursuant to this regulation is effective immediately upon service according to its terms.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>The Department shall conduct a hearing in accordance with the provisions under State Government Article, Title 10, Subtitle 2, Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Judicial Review. A person aggrieved by an order issued by the Department may obtain immediate judicial review under the provisions of State Government Article, §§10-222 and 10-223, Annotated Code of Maryland and the Maryland Rules.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§1-101, 4-401, 4-402, 4-405, 4-407—4-412, 4-415—4-420, and 7-201 et seq.; State Government Article, §§10-206 and 10-226; Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: September 1, 1974 (1:1 Md. R. 33)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07 amended effective April 21, 1978 (5:8 Md. R. 593)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07C amended effective September 12, 1983 (10:18 Md. R. 1607)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07 repealed effective January 28, 1985 (12:2 Md. R. 134)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.06 and .08—.13 transferred to COMAR 10.50.01 effective July 1, 1980</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.21 adopted effective January 28, 1985 (12:2 Md. R. 134)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01A, B, .02C, .04A, .07A, .08A, .12A, .13, .15A, .17A, C amended effective December 28, 1987 (14:26 Md. R. 2743)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .04A, .12A, .13, .14B, C, .15, and .18B amended effective July 1, 1985 (12:13 Md. R. 1278)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06 repealed and new Regulation .06 adopted effective December 28, 1987 (14:26 Md. R. 2743)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09 amended effective September 23, 1985 (12:19 Md. R. 1847)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .14E adopted effective August 26, 1985 (12:17 Md. R. 1702)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .22 adopted effective December 28, 1987 (14:26 Md. R. 2743)</annotation>
      <annotation type="History" subtype="Administrative History">Appendix A amended effective August 26, 1985 (12:17 Md. R. 1702)</annotation>
      <annotation type="History" subtype="Administrative History">Appendix A recodified as Regulation .23 and amended effective December 28, 1987 (14:26 Md. R. 2743)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter recodified from COMAR 08.05.04 to COMAR 26.10.01</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 amended effective January 1, 1996 (22:26 Md. R. 2031); September 7, 1998 (25:18 Md. R. 1438); February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01-1 adopted effective January 1, 1996 (22:26 Md. R. 2031)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02D adopted effective January 1, 1996 (22:26 Md. R. 2031)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04 amended effective January 1, 1996 (22:26 Md. R. 2031)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04A amended effective April 5, 2010 (37:7 Md. R. 575)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05 repealed effective January 1, 1996 (22:26 Md. R. 2031)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05 adopted effective February 24, 1997 (24:4 Md. R. 294)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .07, .16, and .17 amended as an emergency provision effective January 18, 1993 (20:3 Md. R. 256); amended permanently effective July 18, 1993 (20:13 Md. R. 1050)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07A amended effective February 4, 1991 (18:2 Md. R. 151); February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .08A amended effective February 4, 1991 (18:2 Md. R. 151); February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09 amended effective February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09B amended effective February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .12 amended effective February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .12A amended effective February 4, 1991 (18:2 Md. R. 151); February 18, 2002 (29:3 Md. R. 223); April 5, 2010 (37:7 Md. R. 575)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .12B amended effective September 18, 1989 (16:18 Md. R. 2025); February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .13—.15 repealed effective February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .16 amended effective February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .17 amended effective February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .17A amended effective September 18, 1989 (16:18 Md. R. 2025)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .18B amended effective February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .19 repealed effective September 7, 1998 (25:18 Md. R. 1438)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .20A amended effective February 4, 1991 (18:2 Md. R. 151); February 18, 2002 (29:3 Md. R. 223)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .22—.24 repealed effective February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .23 amended effective May 1, 1989 (16:8 Md. R. 911)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .24 adopted effective May 1, 1989 (16:8 Md. R. 911)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .22—.24 recodified from Regulations .25—.27 and adopted effective January 1, 1996 (22:26 Md. R. 2031)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.24 repealed and new Regulations .01—.24 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="02" heading="Underground Storage Tank Systems">
    <regulation prefix="Regulation" num=".01" heading="Applicability.">
      <paragraph num="A.">
        <text>Requirements for an Owner and an Operator of a UST System.</text>
        <paragraph num="(1)">
          <text>Except as otherwise provided in §§B and C of this regulation, an owner and an operator of a UST system that uses or may use the UST system to store a regulated substance are subject to the requirements of this chapter, COMAR 26.10.03—26.10.12, and 26.10.16.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Beginning January 12, 2009, an owner and an operator installing a new or replacement UST system are subject to the interstitial monitoring requirements for methods of release detection in COMAR 26.10.05.05G.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Beginning January 12, 2009, an owner and an operator of a UST system installing new, replacement, or upgraded secondary containment piping are subject to the monitoring requirements for secondary containment piping in COMAR 26.10.05.02D(3).</text>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner and an operator of an airport hydrant fuel distribution system are subject to the requirements in COMAR 26.10.12.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>An owner and an operator of a UST system with one or more field-constructed tanks are subject to the requirements in COMAR 26.10.12.</text>
        </paragraph>
        <paragraph num="(6)">
          <text>An owner and an operator of a UST system that stores fuel for use by an emergency power generator are subject to the methods of release detection requirements in COMAR 26.10.05.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Exclusions. An owner and an operator of the following UST systems are not subject to the requirements of this chapter and COMAR 26.10.03—26.10.12 and 26.10.16:</text>
        <paragraph num="(1)">
          <text>A UST system holding:</text>
          <paragraph num="(a)">
            <text>A hazardous waste listed or identified under Subtitle C of the Resource Conservation and Recovery Act; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A mixture of a hazardous waste, as described under §B(1)(a) of this regulation, and other regulated substances;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A wastewater treatment tank system that is part of a wastewater treatment facility regulated under §307(b) or 402 of the Clean Water Act (33 U.S.C. §1317(b) or 1342);</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Equipment or machinery that contains a regulated substance for operational purposes, such as hydraulic lift tanks and electrical equipment tanks;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>A UST system that contains a de minimis concentration of a regulated substance; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>An emergency spill or overflow containment UST system that is expeditiously emptied after use.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Partial Exclusions.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of the following UST systems are not subject to the requirements under COMAR 26.10.03—26.10.05, 26.10.08, 26.10.10, 26.10.12, and 26.10.16:</text>
          <paragraph num="(a)">
            <text>A wastewater treatment tank system not covered under §B(2) of this regulation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An AST associated with:</text>
            <paragraph num="(i)">
              <text>An airport hydrant fuel distribution system regulated under COMAR 26.10.12; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A UST system with one or more field-constructed tanks regulated under COMAR 26.10.12;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>A UST system containing radioactive material that is regulated under the Atomic Energy Act of 1954 (42 U.S.C. §§2011—2296b-7); and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>A UST system that is part of an emergency generator system at a nuclear power generation facility licensed by the Nuclear Regulatory Commission and subject to the Nuclear Regulatory Commission’s requirements regarding design and quality criteria including, but not limited to, 10 CFR Part 50.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a UST system that stores heating oil only for consumptive use are not subject to the requirements under COMAR 26.10.03.08, 26.10.05, 26.10.11, and 26.10.16.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Definitions.">
      <paragraph num="A.">
        <text>In this chapter and COMAR 26.10.03—26.10.12 and 26.10.16:</text>
        <paragraph num="(1)">
          <text>A term in §B of this regulation has the meaning indicated; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A term not defined in §B of this regulation has the meaning given to it in:</text>
          <paragraph num="(a)">
            <text>A relevant statute;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>COMAR 26.10.01; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>If not defined in a relevant statute or COMAR 26.10.01, the meaning attributed by common use.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>Aboveground Release.</text>
          <paragraph num="(a)">
            <text>“Aboveground release” means a spill, release, or discharge to the surface of the land or to surface water.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Aboveground release” includes, but is not limited to:</text>
            <paragraph num="(i)">
              <text>A release from the aboveground portion of a UST system; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>An aboveground release associated with overfills and transfer operations as a regulated substance moves to or from a UST system.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>“Airport hydrant fuel distribution system” or “airport hydrant system” means a UST system which fuels aircraft and operates under high pressure with large diameter piping that typically terminates into one or more hydrants or fill stands, and begins where fuel enters one or more storage tanks from an external source such as a pipeline, barge, rail car, or other motor fuel carrier.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Belowground Release.</text>
          <paragraph num="(a)">
            <text>“Belowground release” means a spill, release, or discharge to the subsurface of the land, groundwater, or both.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Belowground release” includes, but is not limited to:</text>
            <paragraph num="(i)">
              <text>A release from the belowground portions of a UST system; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A belowground release associated with overfills and transfer operations as a regulated substance moves to or from a UST.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>“Beneath the surface of the ground” means beneath the ground surface or otherwise covered with earthen materials.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Bulk Oil Storage.</text>
          <paragraph num="(a)">
            <text>“Bulk oil storage” means the storage of oil in a UST system that is not excluded under Regulation .01B of this chapter; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Bulk oil storage” does not include the storage of oil in a UST system for consumptive use.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>“CERCLA” means the Comprehensive Environmental Response, Compensation, and Liability Act of 1980, 42 U.S.C. §9601 et seq.</text>
        </paragraph>
        <paragraph num="(7)">
          <text>“Compatible” means the ability of two or more substances to maintain their respective physical and chemical properties upon contact with one another for the design life of a UST system under conditions likely to be encountered in the UST system.</text>
        </paragraph>
        <paragraph num="(8)">
          <text>“Completion” means the final grade of a finished regulated substance storage facility, including all concrete pads and asphalt paving.</text>
        </paragraph>
        <paragraph num="(9)">
          <text>Connected Piping.</text>
          <paragraph num="(a)">
            <text>“Connected piping” means all underground piping, including valves, elbows, joints, flanges, and flexible connectors, attached to a UST system through which a regulated substance or petroleum vapor flows.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Connected piping” includes, for the purpose of determining how much piping is connected to an individual UST system, the piping that joins two UST systems with the piping allocated equally between the UST systems.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(10)">
          <text>Consumptive Use.</text>
          <paragraph num="(a)">
            <text>“Consumptive use” means heating oil consumed on the premises.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Consumptive use” does not include the use of fuel oil in an emergency generator.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(11)">
          <text>“Electrical equipment” means underground equipment that contains dielectric fluid that is necessary for the operation of equipment such as transformers and buried electrical cable.</text>
        </paragraph>
        <paragraph num="(12)">
          <text>Excavation Zone.</text>
          <paragraph num="(a)">
            <text>“Excavation zone” means the volume containing one or more UST systems and backfill material bounded by the ground surface, walls, and floor of a pit and trenches into which a UST system is placed at the time of installation.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Excavation zone” includes a storage tank field.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(13)">
          <text>“Existing UST system” means a UST system used to contain an accumulation of regulated substances for which installation commenced on or before December 22, 1988.</text>
        </paragraph>
        <paragraph num="(14)">
          <text>“Field-constructed tank” means a storage tank constructed in the field, including, but not limited to:</text>
          <paragraph num="(a)">
            <text>A storage tank constructed of concrete that is poured in the field; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A steel or fiberglass storage tank primarily fabricated in the field.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(15)">
          <text>“Free product” refers to a regulated substance that is present as a nonaqueous phase liquid.</text>
        </paragraph>
        <paragraph num="(16)">
          <text>“General UST System Permit” means the authorization established under Regulation .04A of this chapter for the operation of a UST system.</text>
        </paragraph>
        <paragraph num="(17)">
          <text>Groundwater Drain System.</text>
          <paragraph num="(a)">
            <text>“Groundwater drain system” means a permanent installation of a horizontal pipe or gravel trench intercepting the excavation zone of a UST for the purpose of removing, directing, or relieving groundwater accumulation to an alternative location.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Groundwater drain system” does not include a temporary sump pump or temporary well point dewatering system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(18)">
          <text>Hazardous Substance UST System.</text>
          <paragraph num="(a)">
            <text>“Hazardous substance UST system” means a UST system that contains a hazardous substance or any mixture of a hazardous substance and petroleum.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Hazardous substance UST system” does not include a petroleum UST system or a hazardous waste tank regulated under Subtitle C of the Resource Conservation and Recovery Act.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(19)">
          <text>“Hydraulic lift tank” means a tank holding hydraulic fluid for a closed-loop mechanical system that uses compressed air or hydraulic fluid to operate lifts, elevators, and other similar devices.</text>
        </paragraph>
        <paragraph num="(20)">
          <text>“Implementing agency” means the Maryland Department of the Environment.</text>
        </paragraph>
        <paragraph num="(21)">
          <text>“Installation commenced” means an owner and an operator of a UST system has:</text>
          <paragraph num="(a)">
            <text>Obtained all federal, State, and local approvals or permits necessary to begin physical construction of the site or installation of the UST system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Either:</text>
            <paragraph num="(i)">
              <text>Begun a continuous on-site physical construction or installation program; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Entered into contractual obligations, which cannot be cancelled or modified without substantial loss, for physical construction at the site or installation of the UST system to be completed within a reasonable time.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(22)">
          <text>“Liquid trap” means a sump, well cellar, and other trap used in association with oil and gas production, gathering, and extraction operations, including gas production plants, for the purpose of:</text>
          <paragraph num="(a)">
            <text>Collecting oil, water, and other liquids;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Temporarily collecting liquids for subsequent disposition or reinjection into a production or pipeline stream; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Collecting and separating liquids from a gas stream.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(23)">
          <text>“New UST system” means a UST system that is or will be used to contain an accumulation of regulated substances for which installation commenced after December 22, 1988.</text>
        </paragraph>
        <paragraph num="(24)">
          <text>“Noncommercial purposes” means motor fuel not for resale.</text>
        </paragraph>
        <paragraph num="(25)">
          <text>“On the premises” means a UST system storing heating oil located on the same property where the stored heating oil is used.</text>
        </paragraph>
        <paragraph num="(26)">
          <text>“Operational life” means the period beginning when installation of a UST system has commenced until the time the UST system is properly closed in accordance with COMAR 26.10.10.</text>
        </paragraph>
        <paragraph num="(27)">
          <text>“Overfill” means an occurrence when a UST is filled beyond the applicable level specified in COMAR 26.10.03.03A(2)(a), and that may result in a spill, release, or discharge of a regulated substance.</text>
        </paragraph>
        <paragraph num="(28)">
          <text>Petroleum UST System.</text>
          <paragraph num="(a)">
            <text>“Petroleum UST system” means a UST system that contains petroleum or a mixture of petroleum with de minimis quantities of other regulated substances.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Petroleum UST system” includes a UST system that may contain motor fuel, jet fuel, distillate fuel oil, residual fuel oil, heating oil, lubricant, petroleum solvent, or used oil.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(29)">
          <text>“Pipe” or “piping” means a hollow cylinder or tubular conduit that is constructed of nonearthen materials.</text>
        </paragraph>
        <paragraph num="(30)">
          <text>“Pipeline facility” means a new and existing pipe rights-of-way and any associated equipment, facilities, or buildings, including gathering lines.</text>
        </paragraph>
        <paragraph num="(31)">
          <text>“Precision tightness test” means a test:</text>
          <paragraph num="(a)">
            <text>For UST system tightness approved by the Department;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Conducted in accordance with the manufacturer’s test procedure, a test method with third party approval, or standards approved by the Department; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Capable of detecting a 0.1 gallon per hour leak rate from any portion of a UST system, while accounting for the effects of:</text>
            <paragraph num="(i)">
              <text>Thermal expansion;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Contraction of a liquid;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Vapor pockets;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Storage tank deformation;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Evaporation;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Water; and</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>Any subsurface water contacting the UST system.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(32)">
          <text>“Release detection” means to determine whether a release of a regulated substance has occurred:</text>
          <paragraph num="(a)">
            <text>From a UST system into the environment;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Into the interstitial space between a UST system and the secondary barrier of the UST system; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Into the secondary containment around a UST system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(33)">
          <text>“Repair” means to restore to proper operating condition a storage tank, pipe, spill prevention equipment, overfill prevention equipment, corrosion protection equipment, release detection equipment, or other component of a UST system that has:</text>
          <paragraph num="(a)">
            <text>Caused a release of a regulated substance from the UST system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Failed to function properly; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Been rendered inoperable in any way.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(34)">
          <text>“Replace” means to remove and install:</text>
          <paragraph num="(a)">
            <text>A UST; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>40 percent or more of piping connected to a single UST, including each independent piping run connected to a UST with multiple piping runs.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(35)">
          <text>“SARA” means Superfund Amendments and Reauthorization Act of 1986.</text>
        </paragraph>
        <paragraph num="(36)">
          <text>“Septic tank” means a watertight covered receptacle designed to receive or process, through liquid separation or biological digestion, the sewage discharged from a building sewer, with the effluent distributed for disposal through the soil and settled solids and scum from the septic tank are pumped out periodically and hauled to a treatment facility.</text>
        </paragraph>
        <paragraph num="(37)">
          <text>Stormwater or Wastewater Collection System.</text>
          <paragraph num="(a)">
            <text>“Stormwater or wastewater collection system” means piping, pumps, conduits, and any other equipment necessary to collect and transport the flow of:</text>
            <paragraph num="(i)">
              <text>Stormwater runoff resulting from precipitation; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Domestic, commercial, or industrial wastewater to and from retention areas or any areas where treatment is designated to occur.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>“Stormwater or wastewater collection system” does not include the treatment of stormwater or wastewater, except where treatment is incidental to conveyance of stormwater or wastewater.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(38)">
          <text>“Surface impoundment” means a natural topographic depression, man-made excavation, or diked area formed primarily of earthen materials, although it may be lined with man-made materials, that is not an injection well.</text>
        </paragraph>
        <paragraph num="(39)">
          <text>“Under-dispenser containment” means containment underneath a dispenser system that meets the following conditions:</text>
          <paragraph num="(a)">
            <text>Designed to prevent a spill, release, or discharge from the dispenser and piping within or above the under-dispenser containment from reaching soil or groundwater;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Liquid-tight on the sides, bottom, and at any penetration of the containment;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Compatible with the regulated substance conveyed by the piping;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Tested in accordance with COMAR 26.10.03.03; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Allows for visual inspection and access to the components in the containment, or the periodic monitoring of the containment for leaks from the dispenser system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(40)">
          <text>“Upgrade” means:</text>
          <paragraph num="(a)">
            <text>The addition or retrofit of a system designed to prevent the spill, release, or discharge of product from a UST system, such as an interior lining, cathodic protection, or spill and overfill controls; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The replacement of any underground piping connected to a storage tank system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(41)">
          <text>UST.</text>
          <paragraph num="(a)">
            <text>“UST” means one storage tank or a combination of storage tanks, including underground pipes connected to the storage tank, in which the volume of the storage tank and connected underground pipes is 10 percent or more beneath the surface of the ground.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“UST” does not include:</text>
            <paragraph num="(i)">
              <text>Except for a farm or residential tank no longer in use and subject to the requirements under COMAR 26.10.10, a farm or residential tank with the capacity to store 1,100 gallons or less of motor fuel or heating oil for noncommercial purposes;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A septic tank;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A pipeline facility, including gathering lines, regulated under 49 U.S.C. §§60101—60141, or an intrastate pipeline facility regulated under State law as provided under 49 U.S.C. §§60101—60141 and determined by the federal Secretary of Transportation to be connected to a pipeline, or operated or intended to be capable of operating at pipeline pressure or as an integral part of a pipeline;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>A surface impoundment, pit, pond, or lagoon;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>A stormwater or wastewater collection system;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>A flow-through process tank;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>A liquid trap or associated gathering lines directly related to oil or gas production and gathering operations;</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>If a storage tank is situated upon or above the surface of the floor, a storage tank situated in an underground area such as a basement, cellar, mineworking, drift, shaft, or tunnel; or</text>
            </paragraph>
            <paragraph num="(ix)">
              <text>Pipes connected to a tank described under §B(41)(b) of this regulation.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(42)">
          <text>“UST system” means a UST, connected underground piping, underground ancillary equipment, and, if any, containment systems.</text>
        </paragraph>
        <paragraph num="(43)">
          <text>“Wastewater treatment tank” means a tank that is designed to receive and treat an influent wastewater through physical, chemical, or biological methods.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="General Provisions for UST Systems.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system storing a regulated substance shall comply with the general provisions and specifically prohibited acts under COMAR 26.10.01.04.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Person Responsible for a Release.</text>
        <paragraph num="(1)">
          <text>The following persons shall be responsible for the prompt control, containment, and removal of a regulated substance release:</text>
          <paragraph num="(a)">
            <text>The responsible party;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The owner of the property where the regulated substance release occurred;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The owner of the regulated substance;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The owner and the operator of the UST system storing the regulated substance;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The person in charge of the facility, vessel, or vehicle involved in the release; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>If a release occurs from an improperly abandoned UST system, the current landowner and any person who owned, leased, or was otherwise responsible for the UST system at the time it was improperly abandoned.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A person shall continue to be responsible for the control, containment, and removal of a regulated substance release until removal of the regulated substance has been accomplished to the satisfaction of the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Ban on Receiving a Regulated Substance.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system served a written notification provided under §C(2) of this regulation is subject to a ban on receiving a regulated substance until the conditions in §C(3) of this regulation are met.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Upon determining that a UST system is not in compliance with one or more requirements of this chapter or COMAR 26.10.03—26.10.12 and 26.10.16:</text>
          <paragraph num="(a)">
            <text>The Department may serve a written notification to the owner and the operator of the UST system that specifies the Department’s determination, the regulatory provisions violated, and the facts that constitute the violation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Subsequent to or concurrent with service of the written notification provided in §C(2)(a) of this regulation, the Department may:</text>
            <paragraph num="(i)">
              <text>Issue the owner and the operator of the UST system an order requiring the performance of corrective actions necessary to bring the UST system into compliance;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Issue the owner and the operator of the UST system a ban on receiving a regulated substance; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Affix a monitoring device, such as a tag, notice, or locking mechanism to the UST system.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>The Department may allow an owner and an operator of a UST system subject to a ban on receiving regulated substances to resume receiving regulated substances for the UST system if the following conditions are met:</text>
          <paragraph num="(a)">
            <text>The owner and the operator of the UST system notify the Department that the corrective actions necessary to bring the UST system into compliance have been performed;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The owner and the operator of the UST system submit to the Department evidence of the corrective actions performed that includes at least the following records:</text>
            <paragraph num="(i)">
              <text>Receipts;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Work orders;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Certificates;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Testing records; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Photographs;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>The owner and the operator of the UST system have resolved all obligations related to the UST system as directed by the Department or in compliance with an order issued by the Department under §C(2)(b) of this regulation; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The owner and the operator of the UST system receive written approval from the Department to remove the monitoring device from the UST system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Contested Case Hearings.</text>
          <paragraph num="(a)">
            <text>As provided under Environment Article, §4-412, Annotated Code of Maryland, an owner and an operator of a UST system served an order under §C(2)(b) of this regulation shall have an opportunity for a contested case hearing if the owner and the operator of the UST system files a written request with the Department not later than 10 calendar days from the date the order was served.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The filing of a hearing request made in accordance with §C(4)(a) of this regulation does not stay the:</text>
            <paragraph num="(i)">
              <text>Department’s determination of noncompliance;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The ban on receiving a regulated substance; or</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The obligation of the owner and the operator of the UST system to comply with §C(3) of this regulation.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>The Department shall conduct a contested case hearing in accordance with the provisions under State Government Article, Title 10, Subtitle 2, Annotated Code of Maryland.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Work Performed by Certified UST System Individuals.</text>
        <paragraph num="(1)">
          <text>Except as otherwise provided in §D(3) of this regulation, an owner, an operator, and a person in charge of a UST system shall ensure that the following work is performed by the following individuals certified by the Department under COMAR 26.10.06:</text>
          <paragraph num="(a)">
            <text>The installation, upgrade, and repair of a UST system is performed by or under the supervision of a certified UST system technician;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The closure or change-in-service of a UST system is performed by or under the supervision of a certified UST system technician or remover; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Inspections required under COMAR 26.10.03.10 are performed by or under the supervision of a certified UST system inspector.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Except as otherwise provided in §D(3) of this regulation, an owner, an operator, and a person in charge of a storage tank system shall ensure that the following work is performed by the following individuals certified by the Department under COMAR 26.10.06:</text>
          <paragraph num="(a)">
            <text>The installation, upgrade, and repair of a UST system or the underground piping associated with a storage tank is performed in the continuous on-site presence and under the direction of a certified UST system technician; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The closure or a change-in-service of a UST system, underground farm tank, underground residential tank, an underground residential heating oil tank, or the underground piping associated with a storage tank is performed in the continuous on-site presence and direction of a certified UST system technician or remover.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner, an operator, and a person in charge of a UST system storing heating oil for consumptive use and with a capacity of 2,000 gallons or less may use a heating oil technician that is certified by the Department under COMAR 26.10.06 to install, upgrade, repair, and close the UST system.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Installation Requirements for Partially Excluded UST Systems. An owner and an operator of a UST system listed under Regulation .01C of this chapter storing a regulated substance shall install a UST system that meets the following requirements:</text>
        <paragraph num="(1)">
          <text>Will prevent releases due to corrosion or structural failure for the operational life of the UST system;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Is cathodically protected against corrosion, constructed of non-corrodible material, steel clad with a non-corrodible material, or designed in a manner to prevent the release or threatened release of a stored regulated substance; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Is constructed or lined with material that is compatible with the stored regulated substance.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="General UST System Permit by Rule.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system regulated under this chapter are authorized by the Department under a General UST System Permit to operate the UST system provided the conditions specified in this section are met:</text>
        <paragraph num="(1)">
          <text>The owner and the operator of the UST system shall comply with all of the applicable requirements of this chapter and COMAR 26.10.03—26.10.12 and 26.10.16;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The owner and the operator of the UST system shall remove or properly decommission nonoperational components and appurtenances connected to the UST system in order to:</text>
          <paragraph num="(a)">
            <text>Ensure proper operation of all spill and overfill, corrosion protection, and release detection equipment; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Prevent a spill, release, or discharge;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>The owner and the operator of the UST system shall:</text>
          <paragraph num="(a)">
            <text>Make the facility where the UST system is located available for reasonable inspection by the Secretary or the Secretary’s authorized representative; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>During an inspection, allow the Secretary or the Secretary’s authorized representative to:</text>
            <paragraph num="(i)">
              <text>Collect air, ground or surface water, soil, and vegetation samples or samples of other materials on-site as determined necessary by the Department; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Obtain photographic or videographic documentation or evidence;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>The owner and the operator of the UST system shall make all records required under COMAR 26.10 and Environment Article, Annotated Code of Maryland available for inspection and copying by the Secretary or the Secretary’s authorized representative; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>The owner and the operator of the UST system shall complete any survey forms or other documents required by the Department in a timely manner.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Suspension or Revocation.</text>
        <paragraph num="(1)">
          <text>The Department may suspend or revoke a permittee’s authorization provided under §A of this regulation if the Department determines that:</text>
          <paragraph num="(a)">
            <text>A violation of a condition specified under §A of this regulation has occurred;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A violation of an applicable federal, State, or local requirement related to the management of a regulated substance has occurred;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A violation of the Environment Article, Annotated Code of Maryland or a regulation adopted under the Environment Article, Annotated Code of Maryland has occurred;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>False or inaccurate information or data was provided in a document required to be submitted under this regulation to the Department;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>A permittee’s continued operation of a UST system under the General UST System Permit would pose a risk of harm to public health, safety, or welfare or the environment; or</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Any other good cause exists for suspending or revoking the authorization.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Once the Department suspends or revokes a permittee’s authorization provided under §A of this regulation, the permittee shall cease activities permitted under the suspended or revoked authorization in a manner determined by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Judicial Review. A person aggrieved by a permit issued by the Department may obtain immediate judicial review under the provisions of State Government Article, §§10-222 and 10-223, Annotated Code of Maryland and the Maryland Rules.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Violations and Hearing Rights.">
      <paragraph num="A.">
        <text>The provisions of this regulation apply to an owner and an operator of a UST system regulated under COMAR 26.10.</text>
      </paragraph>
      <paragraph num="B.">
        <text>If the Department determines that an owner and an operator of a UST system violated a provision of this chapter or Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland, the Department shall comply with the violation procedures specified under COMAR 26.10.01.24 and Environment Article, §4-412, Annotated Code of Maryland.</text>
      </paragraph>
      <paragraph num="C.">
        <text>In addition to the violation procedures identified under §B of this regulation, if the UST system is a hazardous substance UST system from which a release of a hazardous substance has occurred, the Department shall conduct any applicable enforcement actions under Environment Article, Title 7, Subtitle 2, Part VIII, Annotated Code of Maryland.</text>
      </paragraph>
      <paragraph num="D.">
        <text>Contested Case Hearings.</text>
        <paragraph num="(1)">
          <text>In addition to any other contested case hearing rights provided under this chapter, an owner and an operator of a UST system shall:</text>
          <paragraph num="(a)">
            <text>Have the contested case hearing rights provided under COMAR 26.10.01.24B and Environment Article, §4-412, Annotated Code of Maryland; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In the case of a release of a hazardous substance from a UST system, have the contested case hearing rights provided under Environment Article, §7-261, Annotated Code of Maryland.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The Department shall conduct a contested case hearing in accordance with the provisions under State Government Article, Title 10, Subtitle 2, Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Judicial Review. A person aggrieved by an order issued by the Department may obtain immediate judicial review under the provisions of State Government Article, §§10-222 and 10-223, Annotated Code of Maryland and the Maryland Rules.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-412, 4-415—4-419, 4-701 et seq., and 7-201 et seq.; State Government Article, §§10-206 and 10-226; Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective November 4, 1996 (23:22 Md. R. 1498)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02A, C amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02C amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .03—.03-6 adopted as an emergency provision effective January 26, 2005 (32:4 Md. R. 404); emergency provision extended at 32:15 Md. R. 1315</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .03—.03-6 adopted effective January 16, 2006 (33:1 Md. R. 37)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03B amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03-1 amended as an emergency provision effective July 5, 2006 (33:16 Md. R. 1362); emergency status expired December 31, 2006</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03-2F amended effective April 19, 2010 (37:8 Md. R. 621)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03-4 amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04B amended effective June 29, 1998 (25:13 Md. R. 997); February 18, 2002 (29:3 Md. R. 224); January 16, 2006 (33:1 Md. R. 37); January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05 amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06 amended effective June 29, 1998 (25:13 Md. R. 997); February 18, 2002 (29:3 Md. R. 224); January 12, 2009 (36:1 Md. R. 25); April 19, 2010 (37:8 Md. R. 621)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.06 repealed and new Regulations .01—.05 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="03" heading="UST Systems: Design, Construction, Installation, Registration, and Inspection">
    <regulation prefix="Regulation" num=".01" heading="Performance Standards for New or Replacement UST Systems.">
      <paragraph num="A.">
        <text>An owner and an operator of a new or replacement UST system shall comply with the requirements of this chapter for as long as a UST system is used to store a regulated substance to prevent a spill, release, or discharge due to structural failure, corrosion, or an overfill.</text>
      </paragraph>
      <paragraph num="B.">
        <text>UST Standards for a New or Replacement UST System.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system shall install a UST that is properly designed, constructed, and protected from corrosion in accordance with one of the following methods:</text>
          <paragraph num="(a)">
            <text>The UST is constructed of UL listed fiberglass-reinforced plastic;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The UST is constructed of steel, is coated with a suitable dielectric material, and has one of the following cathodic protection systems:</text>
            <paragraph num="(i)">
              <text>An impressed current system designed by a corrosion expert; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A manufacturer-installed cathodic protection system that is UL listed or approved by STI;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>The UST is constructed of steel and clad or jacketed with a non-corrodible material that is UL listed or approved by STI; or</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Subject to the approval of the Department, the UST is constructed and protected from corrosion by an alternative installation method that is designed to prevent a spill, release, or discharge or a threatened spill, release, or discharge of a stored regulated substance in a manner determined by the Department to be as protective of public health, safety, and welfare and the environment as the USTs described in §B(1)(a)—(c) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a UST system installed after January 11, 2009 shall install a UST that has secondary containment.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner and an operator of a UST system with a cathodic protection system installed in accordance with §B(1)(b) of this regulation shall:</text>
          <paragraph num="(a)">
            <text>Operate and maintain the cathodic protection system in accordance with COMAR 26.10.04.02; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If the UST cathodic protection system is an impressed current system, ensure the impressed current system is designed to allow for the determination of the current operating status as required in COMAR 26.10.04.02.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Notification.</text>
        <paragraph num="(1)">
          <text>In a format required by the Department, an owner, an operator, and a person in charge of a new or replacement UST system shall notify the Department in writing of the installation of the new or replacement UST system not later than 5 working days before installation begins.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In accordance with Regulation .09 of this chapter, an owner, an operator, and a person in charge of a new or replacement UST system shall register the UST system with the Department after the installation of the UST system is complete.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Previously Installed USTs. An owner and an operator of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Only install a previously installed UST if:</text>
          <paragraph num="(a)">
            <text>The owner and the operator submit to the Department a written certification from the UST manufacturer that states the previously installed UST is suitable for service; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The Department has provided the owner and the operator written approval to install the previously installed UST;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Begin the installation of the previously installed UST within 60 days of the issuance of the Department’s written approval to install the UST or in accordance with another schedule required by the Department;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Ensure all UST system standards and installation requirements of COMAR 26.10 are met when installing the previously installed UST; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Maintain the manufacturer’s written certification and the Department’s written approval in accordance with the recordkeeping requirements in COMAR 26.10.04.05.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Performance Standards for Piping.">
      <paragraph num="A.">
        <text>On or after January 26, 2005, an owner and an operator of a UST system shall install, upgrade, or replace piping that routinely contains petroleum vapor or a regulated substance in accordance with the following requirements:</text>
        <paragraph num="(1)">
          <text>Install piping in a UL listed or Department approved secondary containment system that:</text>
          <paragraph num="(a)">
            <text>Contains the petroleum vapor or regulated substance released from the primary piping until the petroleum vapor or regulated substance is detected and removed;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Prevents a spill, release, or discharge of petroleum vapor or a regulated substance to the environment; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>With the exception of the vent riser, beginning June 13, 2022, terminates or connects in a liquid tight containment sump with a sump sensor:</text>
            <paragraph num="(i)">
              <text>Installed within 1 inch of the lowest part of the sump bottom;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Properly secured in the sump by a fixed mounting bracket; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>That activates an alarm when liquid is detected;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Connect piping to the UST in a liquid tight containment sump that is maintained clean and free of liquid;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>When a product dispenser is part of the UST system, install piping that terminates in an under-dispenser containment sump that is liquid tight and maintained clean and free of liquid; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>If an intermediate sump is used, connect piping in a liquid tight containment sump that is maintained clean and free of liquid.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Corrosion Protection Standards for Piping.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system shall ensure that piping in contact with the ground, including soil and backfill material, or continuous or intermittent water, is properly designed, constructed, and protected from corrosion in accordance with one of the following methods:</text>
          <paragraph num="(a)">
            <text>The piping and connectors are constructed of fiberglass-reinforced plastic or flexible piping that is UL listed as appropriate piping for the regulated substance stored and for use in a UST system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The piping is constructed of steel, is coated with a suitable dielectric material, and has a cathodic protection system designed by a corrosion expert; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Subject to the approval of the Department, the piping is constructed and protected from corrosion by an alternative installation method that is designed to prevent a spill, release, or discharge or a threatened spill, release, or discharge of a stored regulated substance in a manner determined by the Department to be as protective of public health, safety, and welfare and the environment as the types of piping described in §B(1)(a) and (b) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a UST system with steel piping equipped with a cathodic protection system installed in accordance with §B(1)(b) of this regulation shall:</text>
          <paragraph num="(a)">
            <text>Operate and maintain the piping cathodic protection system in accordance with COMAR 26.10.04.02; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If the piping cathodic protection system is an impressed current system, ensure the impressed current system is designed to allow for the determination of the current operating status as required in COMAR 26.10.04.02.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of a UST system may not use a fiberglass-reinforced plastic piping system:</text>
        <paragraph num="(1)">
          <text>For direct fill lines, unless approved by the Department; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Aboveground or above grade.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>After January 1, 2009, an owner and an operator that installs a new, upgraded, or replacement UST system may not use a flexible piping system for:</text>
        <paragraph num="(1)">
          <text>Direct fill lines;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Vent lines; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Stage II vapor recovery lines.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>An owner and an operator of a UST system that replaces 40 percent or more of piping connected to a single UST, including each independent piping run connected to a UST with multiple piping runs, shall replace the remaining single-walled piping connected to the UST with a piping system that meets the requirements of this regulation.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Spill and Overfill Prevention Equipment.">
      <paragraph num="A.">
        <text>Except as provided under §C of this regulation, an owner and an operator of a UST system shall use spill and overfill prevention equipment that complies with the requirements of this section.</text>
        <paragraph num="(1)">
          <text>Spill Prevention Equipment. An owner and an operator of a UST system shall install and test spill prevention equipment that will prevent a spill, release, or discharge of a regulated substance into the environment when the transfer hose of a truck tank or transport is detached from the fill pipe or Stage I vapor recovery connection of a UST in accordance with the following requirements:</text>
          <paragraph num="(a)">
            <text>Install a spill catchment basin with a minimum capacity of 5 gallons at the fill pipe of a new, replacement, or upgraded UST;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Beginning November 4, 1996, install a spill catchment basin with a minimum capacity of 5 gallons at the fill pipe of a new, replacement, or upgraded UST system that receives used oil;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Beginning July 1, 1998, install a spill catchment basin with a minimum capacity of 5 gallons at the Stage I vapor recovery connection on a new or replacement UST system that utilizes Stage I vapor recovery; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Test spill prevention equipment for tightness using a method approved by the Department at the following frequency:</text>
            <paragraph num="(i)">
              <text>If the spill prevention equipment was installed before January 26, 2005, within 180 days of that date;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If the spill prevention equipment is installed on or after January 26, 2005, within 30 days of installing the spill prevention equipment;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Upon repair of the spill prevention equipment; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>At least annually after the most recent test was conducted.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Overfill Prevention Equipment. An owner and an operator of a UST system:</text>
          <paragraph num="(a)">
            <text>Shall ensure overfill prevention equipment:</text>
            <paragraph num="(i)">
              <text>Automatically shuts off flow into a UST when the UST is 95 percent full; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Alerts the transfer operator when a UST is 90 percent full by restricting the flow of a regulated substance into the UST or triggering a high level alarm;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>May not install or replace a flow restrictor in a vent line to comply with §A(2)(a) of this regulation after June 13, 2022;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Shall have a UST system inspector or technician certified under COMAR 26.10.06 or a precision tightness tester certified by a test method recognized by the Department conduct an inspection and functional test of overfill prevention equipment as follows:</text>
            <paragraph num="(i)">
              <text>Inspect overfill prevention equipment using a method approved by the Department to ensure the overfill prevention equipment is set to activate at the correct level specified in §A(2)(a) of this regulation when a regulated substance reaches that level in a UST; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Conduct a functional test of the overfill prevention equipment using a method approved by the Department to ensure the overfill prevention equipment will activate when a regulated substance reaches the correct level specified in §A(2)(a) of this regulation; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>Shall conduct inspections and functional tests of overfill prevention equipment in accordance with the procedures in §A(2)(c) of this regulation at the following frequency:</text>
            <paragraph num="(i)">
              <text>Unless an inspection and functional test was conducted before June 13, 2022, within 1 year of June 13, 2022;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Upon the installation or repair of overfill prevention equipment; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>At least every 3 years after the most recent inspection and functional test was conducted.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Containment Sumps. An owner and an operator of a UST system shall:</text>
          <paragraph num="(a)">
            <text>Ensure a containment sump prevents the release of a regulated substance into the environment;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Use a containment sump for all connections of piping to or from a UST and to or from a dispenser; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Test a containment sump for tightness using a method approved by the Department at the following frequency:</text>
            <paragraph num="(i)">
              <text>If the containment sump was installed before January 26, 2005, within 1 year of that date;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If the containment sump is installed on or after January 26, 2005, within 30 days of installing the containment sump;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Upon repair of the containment sump;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>If the most recent test conducted on the containment sump occurred before June 13, 2022, within 5 years of the most recent test; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>At least every 3 years after the most recent test was conducted.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>When a test for tightness conducted on spill prevention equipment or a containment sump results in a failed test result, the owner and the operator of the UST system and the person conducting the test shall report the failed test result to the Department within 2 hours in accordance with COMAR 26.10.08.01.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Dispenser System Requirements.</text>
        <paragraph num="(1)">
          <text>When installing a new dispenser system, an owner and an operator of a UST system shall equip the dispenser system with under-dispenser containment.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A dispenser system is considered new when both the dispenser and the equipment needed to connect the dispenser to a UST system are installed at a regulated substance storage facility.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of a UST system are not required to use the spill and overfill prevention equipment required under §A of this regulation if:</text>
        <paragraph num="(1)">
          <text>The Department determines alternative equipment or methods used for spill and overfill prevention are as protective of public health, safety, and welfare and the environment as the equipment or methods required under §A of this regulation;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Not more than 25 gallons of a regulated substance is transferred at one time to the UST system; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The UST system stores heating oil only for consumptive use and the UST system was installed before November 4, 1996.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Reporting and Recordkeeping.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system shall maintain records demonstrating compliance with the requirements for installing and operating spill and overfill prevention equipment and containment sumps for as long as the UST system is used to store a regulated substance.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If an owner, an operator, and a person in charge of a UST system changes the method of spill or overfill prevention used, the owner, the operator, and the person in charge of the UST system shall provide the Department written notification within 30 days of the change.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>For each inspection and test conducted in compliance with §A(1)(d), (2)(d), and (3)(c) of this regulation, the owner and the operator of the UST system shall:</text>
          <paragraph num="(a)">
            <text>Maintain test records that include at least the following information:</text>
            <paragraph num="(i)">
              <text>The name of the testing company;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The name of the individual conducting the test;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The date of the test;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The data accumulated by the test; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>The results of the test.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Keep the test records on file at the regulated substance storage facility or at a location designated by and under the control of the owner and the operator of the UST system for as long as the UST system is used to store a regulated substance; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Make the records available to the Department upon request.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="UST System Installation Standards.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system shall properly install the UST system in accordance with:</text>
        <paragraph num="(1)">
          <text>The requirements of this regulation;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The applicable technical codes and standards incorporated by reference under COMAR 26.10.01.03;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The manufacturer’s instructions;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The requirement to have a certified UST system technician perform or supervise the installation in accordance with COMAR 26.10.02.03D; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Any alternative installation methods approved by the Department under Regulations .01B(1)(d), .02B(1)(c), and .03C(1) of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Monitoring Pipes. An owner and an operator of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Install two permanent monitoring pipes or, if a UST system is constructed in a high risk groundwater use area or well head protection area as defined in COMAR 26.10.07.02B, four permanent monitoring pipes:</text>
          <paragraph num="(a)">
            <text>Vertically and in opposing corners of a new or replacement UST system excavation zone;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>That extend to a minimum depth of 2 feet below the bottom of the UST in the excavation zone;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Constructed of schedule 40 polyvinyl chloride (PVC);</text>
          </paragraph>
          <paragraph num="(d)">
            <text>That are a minimum of 4 inches in diameter;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Constructed with PVC screened pipe from the bottom to within 2 feet of the top of a monitoring pipe, with the remaining 2 feet being constructed of solid PVC; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>That have a minimum slot size of 0.020 inches and maximum slot size of 0.025 inches with not less than 30 slots per foot; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Complete the installation of the monitoring pipes required under §B(1) of this regulation by:</text>
          <paragraph num="(a)">
            <text>Backfilling around the outside of the monitoring pipes with fine pea gravel or wrapping the monitoring pipes in an appropriate filter cloth to prevent clogging;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Sealing around the top 8 inches to ground surface with a bentonite clay and concrete mixture or by other means to prevent the entrance of surface water runoff;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Capping the monitoring pipes with a liquid-tight threaded cap or removable liquid-tight plug;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Protecting the monitoring pipes from traffic with a manhole and cover;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Locking or bolting closed the monitoring pipes;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Identifying the monitoring pipes to avoid confusion with product fill lines; and</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Having a key or locking tool for the monitoring pipes kept at the regulated substance storage facility.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Excavations. An owner and an operator of a UST system shall perform an excavation for the UST system that is:</text>
        <paragraph num="(1)">
          <text>A minimum distance of 5 feet from the base of adjacent structures or property lines;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If installing a steel UST, a minimum 12-inch distance between other USTs and a minimum 12-inch clearance between a UST and all sides of the excavation zone; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If installing a fiberglass-reinforced plastic UST, a minimum 18-inch distance between other USTs and a minimum 18-inch clearance between a UST and all sides of the excavation zone.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>An owner and an operator of a UST system shall place a UST upon a minimum 12-inch bedding made of backfill material.</text>
      </paragraph>
      <paragraph num="E.">
        <text>Backfill Material. An owner and an operator of a UST system:</text>
        <paragraph num="(1)">
          <text>Shall use backfill material composed of:</text>
          <paragraph num="(a)">
            <text>Pea gravel not larger than 3/4 of an inch; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Crushed stone not larger than 1/2 of an inch;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>May use clean sand as backfill material for protected steel and steel-clad USTs;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Shall use the same material for backfilling operations that is used for bedding; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>May not use backfill material with debris, foreign matter, or frozen matter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>Except where there is, at a minimum, 48 inches of clearance between a UST and shoring, an owner and an operator of a UST system shall remove shoring from the UST system excavation zone when the installation of the UST system is complete.</text>
      </paragraph>
      <paragraph num="G.">
        <text>In an area of high groundwater or where UST movement is possible, an owner and an operator of a UST system shall safeguard a UST against movement from high groundwater or a flood by:</text>
        <paragraph num="(1)">
          <text>Anchoring the UST in compliance with the UST manufacturer’s instructions; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Other means acceptable to the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>When using a hold-down pad or anchors made of concrete to prevent the movement of a UST, an owner and an operator of a UST system shall allow the concrete to cure for a minimum of 48 hours before:</text>
        <paragraph num="(1)">
          <text>Placing a new UST and associated backfill on freshly poured concrete; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Anchoring a UST to the hold-down devices.</text>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>An owner and an operator of a UST system may not install a groundwater drain system in the UST system excavation zone without prior written approval by the Department.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Precision Tightness Testing.">
      <paragraph num="A.">
        <text>After completing the installation or replacement, repair, or upgrade of a UST system, an owner and an operator of a UST system shall test the UST system for tightness using a precision tightness test as defined in COMAR 26.10.02.02B before operation of the UST system.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a UST system shall only conduct a precision tightness test approved by the Department.</text>
      </paragraph>
      <paragraph num="C.">
        <text>For each precision tightness test conducted on a UST system, the owner and the operator of the UST system shall:</text>
        <paragraph num="(1)">
          <text>Maintain and make available for inspection by the Department upon request, records regarding a precision tightness test;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Keep the records on file at the regulated substance storage facility or at a location designated by and the under control of the owner and the operator of the UST system for as long as the UST system is used to store a regulated substance; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Include in the records all of the following information:</text>
          <paragraph num="(a)">
            <text>The commercial name of the test equipment;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The name of the testing company;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The name of the individual conducting the test;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The date of the test;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The data accumulated by the test; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>The results of the precision tightness test.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Inconclusive Precision Tightness Test Results.</text>
        <paragraph num="(1)">
          <text>When a precision tightness test conducted on a UST system results in an inconclusive test result, the owner and the operator of the UST system shall retest the UST system not later than 2 working days after the inconclusive test result.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If a subsequent precision tightness test conducted on a UST system also results in an inconclusive test result, the owner and the operator of the UST system and the person conducting the precision tightness test shall report the test result as a failure to the Department within 2 hours in accordance with COMAR 26.10.08.01.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>When a precision tightness test conducted on a UST system results in a failed test result, the owner and the operator of the UST system and the person conducting the precision tightness test shall report the failed test result to the Department within 2 hours in accordance with COMAR 26.10.08.01.</text>
      </paragraph>
      <paragraph num="F.">
        <text>Consumptive Use UST Systems.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a consumptive use UST system shall comply with the requirements of §§A—E of this regulation.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Unless otherwise required by the Department, an owner and an operator of a consumptive use UST system are not required to conduct precision tightness tests on the consumptive use UST system at the frequency required under §F(3)(a) if the following conditions are met:</text>
          <paragraph num="(a)">
            <text>The UST system is protected against corrosion in accordance with the requirements of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The UST system is installed in accordance with the requirements of this chapter; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The owner and the operator of the UST system conduct monthly release detection monitoring of the UST system in accordance with COMAR 26.10.05.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>If the conditions in §F(2) of this regulation are not met, an owner and an operator of a consumptive use UST system shall:</text>
          <paragraph num="(a)">
            <text>Conduct a precision tightness test on the UST system:</text>
            <paragraph num="(i)">
              <text>15 years after the installation date for the UST system or, if the installation date cannot be determined, immediately; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>At least every 5 years after the most recent precision tightness test; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Conduct a precision tightness test on the UST system immediately upon receipt of a notice from the Department to conduct a precision tightness test.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Piping Installation.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system shall comply with the installation requirements of this regulation.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Install piping in accordance with the requirements of this regulation.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Place underground piping on a 6-inch bedding of appropriate backfill material as described in Regulation .04 of this chapter.</text>
      </paragraph>
      <paragraph num="D.">
        <text>Maintain the following clearances when installing piping:</text>
        <paragraph num="(1)">
          <text>Twice the nominal diameter of the pipe but at least 4 inches between all piping;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At least 6 inches between piping and electrical conduits related to the UST system;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>At least 6 inches between piping and excavation zone sidewalls; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>At least 18 inches between piping and the surface of the ground.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Unless otherwise approved by the Department, ensure piping rises 1/8 of an inch for each lateral foot from the UST to the piping endpoint.</text>
      </paragraph>
      <paragraph num="F.">
        <text>Follow the manufacturer specifications and installation requirements when installing piping.</text>
      </paragraph>
      <paragraph num="G.">
        <text>In accordance with manufacturer specifications, use a UL listed flexible connector to connect piping as follows:</text>
        <paragraph num="(1)">
          <text>Except for a direct fill line, to connect a pipe carrying a regulated substance to a UST at the end of a piping run; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>To connect a pipe carrying a regulated substance to a dispenser system.</text>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>Unless otherwise approved by the Department, an owner and an operator of a UST system may not use a flexible connector to connect piping carrying petroleum vapor or a regulated substance at any other point in the piping system not listed in §G of this regulation.</text>
      </paragraph>
      <paragraph num="I.">
        <text>Place a UL listed shear valve on pressurized product piping dispensing motor fuel, and properly anchor the shear valve at the dispenser.</text>
      </paragraph>
      <paragraph num="J.">
        <text>Install appurtenances such as water or air piping in a separate piping trench;</text>
      </paragraph>
      <paragraph num="K.">
        <text>Ensure vent lines above the ground surface are:</text>
        <paragraph num="(1)">
          <text>Constructed with at least schedule 40 steel;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Protected from traffic;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Properly anchored; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Protected from weather and debris.</text>
        </paragraph>
      </paragraph>
      <paragraph num="L.">
        <text>Ensure the vents of a UST system storing a flammable or combustible liquid meet the following conditions:</text>
        <paragraph num="(1)">
          <text>If the UST system stores a flammable liquid, the vents terminate 12 feet above the ground surface and 2 feet above an attached building; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If the UST system stores a combustible liquid, the vents terminate at least 3 feet above the ground surface.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Compatibility.">
      <text>An owner and an operator of a UST system shall:</text>
      <paragraph num="A.">
        <text>Use a UST system made of or lined with a material compatible with the regulated substance stored in the UST system;</text>
      </paragraph>
      <paragraph num="B.">
        <text>If the UST system stores an ethanol blend, comply with API Recommend Practice 1626 “Storing and Handling Ethanol and Gasoline-ethanol Blends at Distribution Terminals and Filling Stations”;</text>
      </paragraph>
      <paragraph num="C.">
        <text>Provide notification to the Department regarding a change in the regulated substance stored in the UST system as follows:</text>
        <paragraph num="(1)">
          <text>In a format required by the Department, notify the Department in writing at least 30 days before switching to a regulated substance that contains:</text>
          <paragraph num="(a)">
            <text>Greater than 10 percent ethanol;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Greater than 20 percent biodiesel; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Any other regulated substance identified by the Department; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>In accordance with Regulation .09 of this chapter, amend the registration for the UST system after the switch to a regulated substance listed in §C(1) of this regulation is complete;</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>If a UST system stores one of the regulated substances identified in §C of this regulation, demonstrate the compatibility of the UST system with the regulated substance, including the UST, piping, containment sumps, pumping equipment, release detection equipment, spill prevention equipment, and overfill prevention equipment, by using one of the following options:</text>
        <paragraph num="(1)">
          <text>Use equipment or components certified or listed by a nationally recognized association for use with the stored regulated substance;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Use equipment or components with written approval from the manufacturer that affirmatively states the equipment or components are compatible with a specified range of biofuel blends, including the stored regulated substance; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Use equipment or components determined by the Department to be not less protective of public health, safety, and welfare and the environment as the equipment or components specified in §D(1) and (2) of this regulation; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Maintain records documenting compliance with the compatibility requirements under §D of this regulation for as long as the UST system is used to store the regulated substance.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Upgrading Existing UST Systems.">
      <paragraph num="A.">
        <text>This regulation does not apply to an owner and an operator of:</text>
        <paragraph num="(1)">
          <text>A UST system containing heating oil for consumptive use; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A UST system with a field-constructed tank or an airport hydrant fuel distribution system.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Closure of an Existing UST System.</text>
        <paragraph num="(1)">
          <text>Except as provided in §B(2) of this regulation, an owner and an operator of an existing UST system shall permanently close the UST system in accordance with:</text>
          <paragraph num="(a)">
            <text>The closure requirements under COMAR 26.10.10; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The reporting and corrective action requirements under COMAR 26.10.08 and 26.10.09.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of an existing UST system are not required under §B(1) of this regulation to permanently close the existing UST system if the following conditions are met:</text>
          <paragraph num="(a)">
            <text>Upon installation, the existing UST system was installed in accordance with the performance standards under Regulations .01B, .02B, .03A(1)(a) and (2)(a), and .07A of this chapter; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The existing UST system was upgraded on or before December 22, 1998 in accordance with the requirements under §§D—F of this regulation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Unless an existing UST system meets the conditions in §B(2) of this regulation, an owner and an operator of an existing UST system may not allow delivery of a regulated substance to, or dispensing of a regulated substance from, the existing UST system.</text>
      </paragraph>
      <paragraph num="D.">
        <text>Upgrade Requirements.</text>
        <paragraph num="(1)">
          <text>Not later than December 22, 1998, an owner and an operator of an existing UST system with a steel UST shall implement of one the following corrosion protection methods under §D(2) or (3) of this regulation.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Cathodic Protection System. Not later than December 22, 1998, an owner and an operator of an existing UST system with a steel UST shall upgrade the UST by installing a cathodic protection system meeting the performance standards in Regulation .01B(1)(b)(i) and (3) of this chapter, and ensuring the integrity of the UST through one of the following methods:</text>
          <paragraph num="(a)">
            <text>Internally inspect and assess the UST to ensure the storage tank is structurally sound and free of corrosion holes;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Demonstrate the UST was not installed before December 22, 1988, and the UST has been monitored monthly for releases in accordance with COMAR 26.10.05.05E—H;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Demonstrate the UST was not installed before December 22, 1988, and the UST has been assessed by conducting two precision tightness tests meeting requirements of Regulation .05A—C of this chapter and the following testing schedule:</text>
            <paragraph num="(i)">
              <text>The first precision tightness test was conducted before installing the cathodic protection system; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The second precision tightness test was conducted between 3 and 6 months following the first operation of the cathodic protection system; or</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>Demonstrate that the UST was assessed for corrosion holes using a method determined by the Department to prevent spills, releases, and discharges in a manner that is not less protective of public health, safety, and welfare and the environment than the methods specified under §D(2)(a)—(c) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Internal Lining Combined with Cathodic Protection. Not later than December 22, 1998, an owner and an operator of an existing UST system with a steel UST that meets the requirements of API Standard 1631 “Interior Lining and Periodic Inspection of Underground Storage Tanks” shall upgrade the steel UST with an internal lining and a cathodic protection system as follows:</text>
          <paragraph num="(a)">
            <text>Before applying the interior lining, determine if there is evidence of a spill, release, or discharge from the UST system where a spill, release, or discharge is most likely to be present;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Apply the interior lining:</text>
            <paragraph num="(i)">
              <text>In compliance with the repair standards in COMAR 26.10.04.04; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>In accordance with the requirements in API Standard 1631 “Interior Lining and Periodic Inspection of Underground Storage Tanks”;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Install a cathodic protection system that meets the performance standards for cathodic protection under Regulation .01B(1)(b)(i) and (3);</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Conduct a precision tightness test on the UST system in accordance with Regulation .05A—C of this chapter before placing the UST system back into service;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Maintain, and make available for inspection by the Department upon request, a written certification from the contractors that performed the work required under §D(3)(a)—(d) of this regulation that states all work was performed in accordance with the requirements of this regulation; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Internally inspect the lined UST within the first 10 years after applying the lining and at least every 5 years thereafter, with the results of each inspection finding that the lining is structurally sound and performing in accordance with the original design specifications.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>After December 22, 1998, if the internal lining of an existing UST system upgraded using the method in §D(3) of this regulation no longer performs in accordance with original design specifications, the owner and the operator of the existing UST system shall permanently close the UST system in accordance with procedures in COMAR 26.10.10.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Piping Upgrade Requirements. Not later than December 22, 1998, an owner and an operator of an existing UST system shall upgrade metal piping in contact with the ground by installing a cathodic protection system that meets the performance standards for cathodic protection under Regulation .02B(1)(b) and (2) of this chapter.</text>
      </paragraph>
      <paragraph num="F.">
        <text>Spill and Overfill Prevention Equipment Requirements. Not later than December 22, 1998, an owner and an operator of an existing UST system shall upgrade the UST system to meet the performance standards under Regulation .03A(1)(a) and (2)(a) of this chapter.</text>
      </paragraph>
      <paragraph num="G.">
        <text>In accordance with Regulation .09 of this chapter, an owner, an operator, and a person in charge of an existing UST system shall amend the registration for the existing UST system after an upgrade performed in compliance with this regulation is complete.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".09" heading="UST System Registration Requirements.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of one or more UST systems shall:</text>
        <paragraph num="(1)">
          <text>Register each UST system with the Department and maintain up-to-date registration for each UST system with the Department;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Submit to the Department a completed registration form for a UST system to the Department not later than 30 days following the:</text>
          <paragraph num="(a)">
            <text>Installation of a new or replacement UST system; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Acquisition of a new or replacement UST system;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Amend the registration for a registered UST system by submitting to the Department a registration form not later than 30 days following:</text>
          <paragraph num="(a)">
            <text>The return of a temporarily closed UST system to in-service status;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A change in the regulated substance stored;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A change-in-service to store a non-regulated substance in a UST system;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>An upgrade of an existing UST system;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The temporary closure or permanent closure of a UST system; or</text>
          </paragraph>
          <paragraph num="(f)">
            <text>If applicable, an owner of UST system being released from the requirement to maintain financial responsibility or obtaining coverage under an alternate mechanism of financial responsibility; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Include on a submitted registration form all of the information requested on the form, including:</text>
          <paragraph num="(a)">
            <text>If amending the registration for a registered UST system, information remaining unchanged since the last registration form was submitted for the UST system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A certification of the UST system owner’s compliance with the:</text>
            <paragraph num="(i)">
              <text>Installation of a UST and piping requirements under this chapter;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Installation of spill and overfill prevention equipment requirements under this chapter;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Cathodic protection of steel USTs and piping requirements under Regulations .01 and .02 of this chapter;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Financial responsibility requirements under COMAR 26.10.11; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Release detection requirements under COMAR 26.10.05 and, if a UST system with a field-constructed tank or an airport hydrant system, 26.10.12;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>If the UST system is used in the operation of a commercial or business entity, certification and proof that:</text>
            <paragraph num="(i)">
              <text>The owner has registered the commercial or business entity with the Maryland Department of Assessments and Taxation; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The commercial or business entity is in good standing with the State at the time of the UST system initial or amended registration; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>A certification from a certified UST system technician that the methods used to install the UST system comply with the requirements in COMAR 26.10.02—26.10.12 and 26.10.16.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of a UST system required to register or amend the registration for a UST system under §A of this regulation:</text>
        <paragraph num="(1)">
          <text>May register or amend the registration for one or more UST systems located at one place of operation using one registration form; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Shall register or amend the registration for UST systems located at separate places of operation using separate registration forms for each place of operation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>A person who sells a UST system shall inform the purchaser of the registration obligation under §A of this regulation and provide the purchaser with a copy of the Department’s registration form.</text>
      </paragraph>
      <paragraph num="D.">
        <text>An owner, an operator, and person in charge of a UST system that is not registered with the Department may not sell, receive, or dispense oil or any other regulated substance to or from the UST system, with the exception of the minimum amount of a regulated substance necessary to conduct an initial precision tightness test for a new or replacement UST system.</text>
      </paragraph>
      <paragraph num="E.">
        <text>An owner, an operator, and a person in charge of a registered UST system shall:</text>
        <paragraph num="(1)">
          <text>Display the UST system registration certificate issued by the Department at the regulated substance storage facility; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Produce the UST system registration certificate immediately upon the request of the Department.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".10" heading="UST System Inspection Requirements.">
      <paragraph num="A.">
        <text>An owner of a motor fuel, bulk oil storage, used oil, or a hazardous substance UST system shall have a certified inspection completed for the UST system:</text>
        <paragraph num="(1)">
          <text>By a UST system inspector certified by the Department under COMAR 26.10.06;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>To verify the owner’s and the operator’s compliance with the UST system requirements established under this chapter and COMAR 26.10.02, 26.10.04, 26.10.05, 26.10.07—26.10.12 and 26.10.16; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>In accordance with the schedule established under §B of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Inspection Schedule. An owner of a motor fuel, bulk oil storage, used oil, or a hazardous substance UST system shall complete:</text>
        <paragraph num="(1)">
          <text>An initial inspection of the UST system:</text>
          <paragraph num="(a)">
            <text>If the UST system was installed before January 16, 2006, within 30 days of receiving a notification from the Department to complete an inspection; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If the UST system was installed on or after January 16, 2006, within 6 months of the UST system installation;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A subsequent inspection of the UST system:</text>
          <paragraph num="(a)">
            <text>At least once every 3 years following the most recent inspection;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Within 30 days of receiving a notification from the Department to complete an inspection; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>If the ownership of the UST system changes, within 3 months of the change in ownership.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Additional Inspections.</text>
        <paragraph num="(1)">
          <text>If required by the Department, an owner of a motor fuel, bulk oil storage, used oil, or a hazardous substance UST system shall complete an inspection in addition to an inspection required under §B of this regulation to verify compliance with the UST system requirements under this chapter and COMAR 26.10.02, 26.10.04, 26.10.05, 26.10.07—26.10.12 and 26.10.16.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner of a motor fuel, bulk oil storage, used oil, or a hazardous substance UST system may not substitute an inspection required by the Department under §C(1) of this regulation for an inspection required under §B of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>After conducting an inspection required under §B or C of this regulation, an owner of a motor fuel, bulk oil storage, used oil, or a hazardous substance UST system shall:</text>
        <paragraph num="(1)">
          <text>Submit to the Department an inspection report on forms provided by the Department:</text>
          <paragraph num="(a)">
            <text>Within 30 days of the deadline to complete an inspection established under §B or C of this regulation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Completed by a certified UST system inspector;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Signed by the certified UST system inspector that conducted the inspection; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Signed by the owner, the operator, and the person in charge of the UST system; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Unless the Department determines immediate corrective action by the owner is required to protect public health, safety, and welfare and the environment, within 30 days of receiving a Notice to Correct Deficiencies issued by the Department:</text>
          <paragraph num="(a)">
            <text>Correct all of the deficiencies identified during the inspection in accordance with the UST system requirements under this chapter and COMAR 26.10.02, 26.10.04, 26.10.05, 26.10.07—26.10.12 and 26.10.16; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Submit to the Department proof of corrective actions performed to correct the deficiencies.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Recordkeeping. For a minimum of 5 years, an owner of a motor fuel, bulk oil storage, used oil, or a hazardous substance UST system shall maintain records of completed inspections at a location designated by the owner and make the records available to the Department upon request.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-411.2, 4-415.1, 4-417, 4-701 et seq., and 7-201 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective November 4, 1996 (23:22 Md. R. 1498)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01B amended effective June 29, 1998 (25:13 Md. R. 997)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02 amended as an emergency provision effective January 26, 2005 (32:4 Md. R. 406); emergency provision extended at 32:15 Md. R. 1315</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02 amended effective January 16, 2006 (33:1 Md. R. 38); January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03A amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03A amended as an emergency provision effective January 26, 2005 (32:4 Md. R. 406); emergency provision extended at 32:15 Md. R. 1315</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03A amended effective January 16, 2006 (33:1 Md. R. 38)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03D adopted effective June 29, 1998 (25:13 Md. R. 997)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04B amended effective January 16, 2006 (33:1 Md. R. 38)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04H adopted effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04I adopted effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05A amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07E amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .08 amended effective June 29, 1998 (25:13 Md. R. 997); February 18, 2002 (29:3 Md. R. 224); January 16, 2006 (33:1 Md. R. 38)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09 amended effective January 16, 2006 (33:1 Md. R. 38)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .10 adopted effective January 16, 2006 (33:1 Md. R. 38)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .10 amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.10 repealed and new Regulations .01—.10 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="04" heading="UST Systems: General Operating Requuirements">
    <regulation prefix="Regulation" num=".01" heading="Spill and Overfill Control.">
      <paragraph num="A.">
        <text>Delivery and Transfer Operations. An owner and an operator of a UST system shall ensure:</text>
        <paragraph num="(1)">
          <text>The ullage available in the UST is greater than the volume of the regulated substance to be transferred to the UST before delivery or transfer begins;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>During a delivery or transfer operation:</text>
          <paragraph num="(a)">
            <text>A spill, release, or discharge of a regulated substance does not occur due to overfilling the UST or spilling a regulated substance during the transfer; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The delivery or transfer operation is constantly monitored to prevent overfilling of the UST and spilling of a regulated substance;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>The delivery or transfer operation is conducted in accordance with the requirements in COMAR 26.10.01.16 and .17 and NFPA 385 “Standard for Tank Vehicles for Flammable and Combustible Liquids”; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The company making an oil delivery or transfer using a truck tank or transport with a cargo tank capacity of 500 gallons or greater holds a valid Individual Oil Operations Permit from the Department in accordance with COMAR 26.10.01.09.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a UST system and a responsible party shall report, investigate, and remediate spills, releases, and discharges and overfills from a UST system in accordance with COMAR 26.10.08.04.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Liquid Level Measurements.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a metered UST system shall:</text>
          <paragraph num="(a)">
            <text>Each day of operation, measure the liquid level of the UST using a gauging stick or an electronic method and reconcile the results with:</text>
            <paragraph num="(i)">
              <text>Pump meter readings of the UST; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Regulated substance delivery receipts for the UST;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Perform inventory in accordance with “USEPA Doing Inventory Control Right for Underground Storage Tanks”; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Review reconciled inventory records in accordance with the inventory control requirements in COMAR 26.10.05.04.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a non-metered UST system designed to allow for the direct measurement of liquid levels in the UST shall gauge the liquid level in the UST using a gauging stick or an electronic method and record the measurements in writing before filling the UST.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner and an operator of a UST system shall maintain the liquid level measurement and inventory reconciliation records required under §C(1) and (2) of this regulation:</text>
          <paragraph num="(a)">
            <text>For 5 years at the regulated substance storage facility where the UST system is located, or another location designated by the owner of the UST system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In accordance with Regulation .05 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Delivery and Transfer Equipment. An owner and an operator of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Ensure spill catchment basins are kept clean and dry;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In order to prevent liquid or other matter from entering the UST system, return and secure any fill pipe or Stage I vapor recovery connection cap taken off during a delivery or transfer operation;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Install a UST system designed to allow for the direct measurement of liquid levels using the gauging stick method;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Maintain a storage tank gauging stick in good operating condition and capable of measuring the level of a regulated substance over the full range of the UST and riser pipe height to the nearest 1/8 inch;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>In compliance with NFPA 30 “Flammable and Combustible Liquids Code”, install a drop-tube in the fill pipe of:</text>
          <paragraph num="(a)">
            <text>A UST system that stores a flammable substance; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A UST system with a capacity greater than 1,100 gallons that stores a combustible substance;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>Install a high liquid level gauge, an alarm system, or a pump cut-off device on a UST system if the Department determines an overfill of oil is possible;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>If a vent is not visible to a person positioned at the UST system fill, conduct additional procedures for filling a UST system as required by the Department to ensure a safe transfer or delivery of a regulated substance;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>To indicate the size of a UST and the type of regulated substance stored, clearly mark all fill pipes for a UST system as follows:</text>
          <paragraph num="(a)">
            <text>Install a permanent tag or sign immediately adjacent to the fill pipe that states the size of the UST and the specific type of regulated substance being stored; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Use a color code that conforms to the following requirements:</text>
            <paragraph num="(i)">
              <text>Using the marking system recommended in API Recommended Practice 1637 “Using the API Color-Symbol System to Identify Equipment, Vehicles, and Transfer Points for Petroleum Fuels and Related Products at Dispensing and Storage Facilities and Distribution Terminals”, paint or place color markings around the fill pipe or manhole cover in a manner that will readily identify the regulated substance stored in the UST; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Print the color code on a sign that is not less than 8 x 10 inches in size with letters not less than 5/16 inch high, post the sign at the regulated substance storage facility in a prominent location visible from the fill pipe area, and make the signage available for inspection at all times to show the UST size and type of regulated substance stored;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(9)">
          <text>Only mark pipes or openings used for the transfer of a regulated substance stored at the regulated substance storage facility in a manner that associates the pipes or openings with the transfer of that regulated substance; and</text>
        </paragraph>
        <paragraph num="(10)">
          <text>Keep a key or other access device at the regulated substance storage facility for access to a dispenser system connected to the UST system.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Operation and Maintenance of Corrosion Protection.">
      <paragraph num="A.">
        <text>An owner and an operator of a metal UST system with corrosion protection shall:</text>
        <paragraph num="(1)">
          <text>Comply with the requirements of this regulation to prevent a spill, release, or discharge due to corrosion until the UST system is permanently closed or undergoes a change-in-service pursuant to COMAR 26.10.10.02;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Operate and maintain a corrosion protection system to continuously provide corrosion protection to the metal components of the UST system in contact with the ground, including soil and backfill material, or continuous or intermittent water; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If the UST system is protected by an impressed current system, design the UST system so that the impressed current source cannot be de-energized at any time, except to perform service work on the UST system or the impressed current system.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Inspections. An owner and an operator of a UST system equipped with a cathodic protection system shall comply with all of the following inspection requirements:</text>
        <paragraph num="(1)">
          <text>Determine if the cathodic protection system is adequate and complies with the requirements of this regulation by using criteria established in a NACE or STI code of practice incorporated by reference under COMAR 26.10.01.03;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Inspect the UST system for proper operation by having a qualified cathodic protection tester:</text>
          <paragraph num="(a)">
            <text>Test a field-installed cathodic protection system within 6 months of installation, and at least annually thereafter; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Test a factory-installed cathodic protection system within 6 months of installation, and at least once every 3 years thereafter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>If a qualified cathodic protection tester determines the cathodic protection system is inadequate per a NACE or STI code of practice:</text>
          <paragraph num="(a)">
            <text>Notify the Department of the failed test in compliance with the suspected spill, release, or discharge reporting requirements in COMAR 26.10.08.01; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Repair the cathodic protection system in accordance with a NACE or STI code of practice within 60 days of the failed test; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>If the UST system is designed with an impressed current system:</text>
          <paragraph num="(a)">
            <text>Inspect the UST system at least every 60 days to ensure that the impressed current system is functioning properly; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Have a complete assessment of the impressed current system performed by a corrosion expert:</text>
            <paragraph num="(i)">
              <text>When the impressed current system reaches 5 years of age, and at least every 5 years after the most recent assessment; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>In accordance with the guidance as established under a NACE code of practice.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of a UST system equipped with a cathodic protection system shall:</text>
        <paragraph num="(1)">
          <text>In accordance with Regulation .05C of this chapter, maintain and upon request by the Department provide records of the operation and maintenance of the cathodic protection system that demonstrate compliance with performance standards of this regulation; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Include in the records required to be maintained under §C(1) of this regulation the following information:</text>
          <paragraph num="(a)">
            <text>The results of the last three inspections and the last assessment of an impressed current system conducted in accordance with §B(4) of this regulation; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The results of testing from the last two inspections of a cathodic protection system conducted in accordance with §B(2) of this regulation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Periodic Operation and Maintenance Walkthrough Inspections.">
      <paragraph num="A.">
        <text>Beginning not later than 90 days after June 13, 2022, an owner and an operator of a UST system shall conduct a periodic operation and maintenance walkthrough inspection in accordance with:</text>
        <paragraph num="(1)">
          <text>The inspection procedures under §B or C of this regulation; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The recordkeeping requirements under §D of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a UST system may meet the inspection requirements in §A(1) of this regulation by, at a minimum, checking:</text>
        <paragraph num="(1)">
          <text>The spill prevention equipment:</text>
          <paragraph num="(a)">
            <text>On a monthly basis or, if the UST system receives deliveries at intervals greater than 30 days, prior to each delivery; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>By completing the following tasks:</text>
            <paragraph num="(i)">
              <text>Visually checking the equipment for damage;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Removing liquid and debris from the equipment;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Checking for and removing obstructions in the fill pipe;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Checking the fill cap to ensure the cap is securely on the fill pipe; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>For double-walled spill prevention equipment with interstitial monitoring, checking for a release in the interstitial area;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>On a monthly basis, the release detection equipment to ensure:</text>
          <paragraph num="(a)">
            <text>The equipment is operating with no alarms or other unusual operating conditions present; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The records of release detection testing are reviewed and are current;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>On an annual basis, the containment sumps by:</text>
          <paragraph num="(i)">
            <text>Visually checking the containment sumps for damage;</text>
          </paragraph>
          <paragraph num="(ii)">
            <text>Checking for a release in the containment area and a spill, release, or discharge to the environment;</text>
          </paragraph>
          <paragraph num="(iii)">
            <text>Removing liquid and debris from the containment sumps; and</text>
          </paragraph>
          <paragraph num="(iv)">
            <text>For double-walled containment sumps with interstitial monitoring, checking for a release in the interstitial area; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>On an annual basis, the hand held release detection equipment by checking devices such as storage tank gauging sticks and groundwater bailers for operability and serviceability.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of a UST system may meet the inspection requirements in §A(1) of this regulation by using an alternative procedure:</text>
        <paragraph num="(1)">
          <text>Established in guidance developed by the Department or a standard code of practice developed by a nationally recognized association incorporated by reference under COMAR 26.10.01.03; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>That checks equipment comparable to the equipment required to be checked under §B of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>An owner and an operator of a UST system shall maintain records of the operation and maintenance walkthrough inspections:</text>
        <paragraph num="(1)">
          <text>In accordance with Regulation .05 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>For at least 1 year at the regulated substance storage facility where the UST system is located;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>For at least 5 years at a location designated by the owner; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>That include the following information:</text>
          <paragraph num="(a)">
            <text>A list of each area checked during the inspection;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Whether an area inspected was acceptable or needed action taken;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>If an action was taken to correct an issue, a description of the action taken; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Delivery records if the spill prevention equipment is checked prior to a delivery because deliveries occur at intervals greater than 30 days.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Repairs Allowed.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system shall conduct repairs that:</text>
        <paragraph num="(1)">
          <text>Prevent spills, releases, and discharges due to structural failure or corrosion for the entire period in which a UST system is used to store regulated substances;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Comply with the applicable code of practices developed by a nationally recognized association incorporated by reference under COMAR 26.10.01.03; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Meet all of the requirements of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a UST system shall have repairs to the equipment and components of the UST system performed or supervised by a UST system technician certified in accordance with COMAR 26.10.06.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Repair Procedures. An owner and an operator of a UST system:</text>
        <paragraph num="(1)">
          <text>Upon approval of the Department, shall have repairs conducted on a fiberglass-reinforced plastic or steel UST:</text>
          <paragraph num="(a)">
            <text>By an authorized representative of the UST manufacturer; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In accordance with a code of practice developed by a nationally recognized association incorporated by reference under COMAR 26.10.01.03;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>May not repair a UST by installing an internal liner;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Shall replace a metal pipe that has sections or fittings in which corrosion or other damage has resulted in:</text>
          <paragraph num="(a)">
            <text>A spill, release, or discharge of a regulated substance; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An imminent threat of a spill, release, or discharge of a regulated substance, as determined by the Department;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Shall repair non-corrodible pipes and fittings in accordance with the manufacturer’s specifications; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Shall repair a containment sump with materials rated by the material manufacturer for the regulated substance stored in the UST system.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Testing of Repaired UST Systems. An owner and an operator of a repaired UST system shall:</text>
        <paragraph num="(1)">
          <text>Before placing the UST system back into service, conduct a precision tightness test in accordance with COMAR 26.10.03.05 to test the repaired UST and piping;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Before placing the UST system back into service, test secondary containment areas of the UST, piping, and containment sumps in accordance with:</text>
          <paragraph num="(a)">
            <text>The manufacturer’s instructions;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A code of practice developed by a nationally recognized association incorporated by reference under COMAR 26.10.01.03; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Requirements established by the Department; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Within 6 months of completing a repair on a cathodically protected UST system, test the cathodic protection system:</text>
          <paragraph num="(a)">
            <text>To ensure the cathodic protection system is operating properly; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In accordance with Regulation .02B of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Recordkeeping. In accordance with Regulation .05 of this chapter, an owner and an operator of a UST system shall maintain records of each repair conducted on the UST system until the UST system is permanently closed or undergoes a change-in-service pursuant to COMAR 26.10.10.02.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Access, Reporting, and Recordkeeping.">
      <paragraph num="A.">
        <text>Access. An owner, an operator, and a person in charge of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Make available for inspection by the Secretary or the Secretary’s authorized representative:</text>
          <paragraph num="(a)">
            <text>The regulated substance storage facility where the UST system is located; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An alternative site where records regarding the operation of the UST system are maintained;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Allow the Department to:</text>
          <paragraph num="(a)">
            <text>Make copies of data, records, and information pertaining to the UST system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Collect air, ground or surface water, soil, and vegetation samples or samples of other materials on-site as determined necessary by the Department; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Obtain photographic or videographic documentation or evidence; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Following a spill, release, or discharge, allow a responsible party access to the site to conduct remedial activities.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Reporting. An owner and an operator of a UST system shall submit the following documentation to the Department:</text>
        <paragraph num="(1)">
          <text>A registration form for the UST system following certain events, as required under COMAR 26.10.03.09;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A notification regarding the planned storage of a certain regulated substance in the UST system required under COMAR 26.10.03.07C;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A report of a spill, release, or discharge or an overfill required under COMAR 26.10.01.05 and 26.10.08 and any other applicable provision under COMAR 26.10;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>A report of corrective actions planned or taken required under Environment Article, §§4-412 and 7-259, Annotated Code of Maryland and any applicable provision of COMAR 26.10, including COMAR 26.10.09.03—.07; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>A notification of a planned permanent closure or change-in-service of the UST system required under COMAR 26.10.10.02.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Recordkeeping. An owner and an operator of a UST system shall maintain and make available to the Department, the following records:</text>
        <paragraph num="(1)">
          <text>If the UST system was installed after January 1, 2006, an as-built diagram of the UST system that includes a layout of the USTs and piping of the UST system;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Documentation supporting an alternative method of corrosion protection for the construction of a UST or piping, such as an analysis of the site corrosion potential from a corrosion expert, pursuant to COMAR 26.10.03.01B(1)(d) or .02B(1)(c);</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Records of the installation of a previously installed UST, pursuant to COMAR 26.10.03.01D;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Records that demonstrate compliance with the requirements for installing, operating, and testing spill and overfill prevention equipment and containment sumps in COMAR 26.10.03.03;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Records of the compatibility of the UST system with a stored regulated substance, pursuant to COMAR 26.10.03.07;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Records of upgrades made to the existing UST system, pursuant to COMAR 26.10.03.08;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Records of certified inspections conducted pursuant to COMAR 26.10.03.10;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>The liquid level measurement and inventory reconciliation records required under Regulation .01C of this chapter;</text>
        </paragraph>
        <paragraph num="(9)">
          <text>Records of the operation and maintenance of corrosion protection equipment, pursuant to Regulation .02 of this chapter;</text>
        </paragraph>
        <paragraph num="(10)">
          <text>Records of the periodic operation and maintenance walkthrough inspections conducted pursuant to Regulation .03 of this chapter;</text>
        </paragraph>
        <paragraph num="(11)">
          <text>Records of repairs performed on the UST system, pursuant to Regulation .04 of this chapter;</text>
        </paragraph>
        <paragraph num="(12)">
          <text>Records that demonstrate compliance with the release detection requirements under COMAR 26.10.05, pursuant to COMAR 26.10.05.06;</text>
        </paragraph>
        <paragraph num="(13)">
          <text>Records that demonstrate compliance with the release detection requirements under COMAR 26.10.12, pursuant to COMAR 26.10.12.07;</text>
        </paragraph>
        <paragraph num="(14)">
          <text>Documentation regarding certified Class A, Class B, and Class C operators designated for the regulated substance storage facility and the operator training and certification, pursuant to COMAR 26.10.16.09; and</text>
        </paragraph>
        <paragraph num="(15)">
          <text>Records documenting the UST system being take out-of-service through a closure or change-in-service, including the results of an investigation conducted at the site where the UST system underwent a temporary or permanent closure or a change-in-service, pursuant to COMAR 26.10.10.05.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Availability and Maintenance of Records.</text>
        <paragraph num="(1)">
          <text>Unless otherwise required in this chapter or COMAR 26.10.03, 26.10.05, 26.10.10, 26.10.12, and 26.10.16, an owner and an operator of a UST system shall keep the records required under §C of this regulation for the operational life of the UST system at:</text>
          <paragraph num="(a)">
            <text>The regulated substance storage facility where the UST system is located; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A readily available alternative site under the control of the UST system owner.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>If a UST system underwent permanent closure and the records required under COMAR 26.10.10.05 cannot be maintained at one of the locations specified in §D(1) of this regulation, the owner and the operator of the UST system shall submit the permanent closure records to the Department.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-411.2, 4-415.1, 4-417, 4-701 et seq., and 7-201 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective November 4, 1996 (23:22 Md. R. 1498)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01F amended as an emergency provision effective July 5, 2006 (33:16 Md. R. 1363); emergency status expired December 31, 2006</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02F, G amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04 amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05C amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05D amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.05 repealed and new Regulations .01—.05 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="05" heading="UST Systems: Release Detection">
    <regulation prefix="Regulation" num=".01" heading="Release Detection: General Requirements for All UST Systems.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system shall provide a method, or combination of methods, of release detection that:</text>
        <paragraph num="(1)">
          <text>Can detect a spill, release, or discharge from any portion of the UST and the connected underground piping;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Is installed and calibrated in accordance with the manufacturer’s instructions;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Is operated and maintained in accordance with:</text>
          <paragraph num="(a)">
            <text>The manufacturer’s instructions;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A code of practice incorporated by reference under COMAR 26.10.01.03; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Requirements determined by the Department to be not less protective of human health and the environment than §A(3)(a) or (b) of this regulation;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Meets the performance requirements in Regulations .02 and .05 of this chapter, or COMAR 26.10.12 for a UST system with a field-constructed tank or an airport hydrant system, as applicable, with performance claims verified by the manufacturer’s specifications; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Is capable of detecting a leak at a rate or quantity specified in this chapter with a probability of detection of not less than 0.95 and a probability of false alarm of not more than 0.05.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Beginning January 12, 2009, an owner and an operator of a UST system installing a new or replacement UST system shall monitor the UST system for a spill, release, or discharge at least monthly by interstitial monitoring in accordance with Regulation .05G of this chapter.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Release Detection Operability Test. An owner and an operator of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Have the electronic and mechanical components of a release detection method tested for proper operation in accordance with:</text>
          <paragraph num="(a)">
            <text>The manufacturer’s instructions;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A code of practice incorporated by reference under COMAR 26.10.01.03; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Requirements determined by the Department to be not less protective of human health and the environment than §C(1)(a) or (b) of this regulation;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Perform an operability test of each electronic and mechanical component of a release detection method used at a regulated substance storage facility in accordance with the following criteria:</text>
          <paragraph num="(a)">
            <text>For the automatic tank gauge and other controllers:</text>
            <paragraph num="(i)">
              <text>Test the alarm;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Verify the system configuration; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Test the battery backup;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>For the probes and sensors:</text>
            <paragraph num="(i)">
              <text>Inspect the equipment for residual buildup;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Ensure the floats move freely;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Ensure the shafts are not damaged;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Ensure the cables are free of kinks and breaks; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Test the alarm operability and communication with the controller;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Test the operation of the automatic line leak detector to meet the criteria in Regulation .02D(2) of this chapter by simulating a leak;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Ensure the proper communication of the vacuum pumps and pressure gauges with the sensors and controller; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Ensure the proper operation of the hand-held electronic sampling equipment associated with groundwater monitoring;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Perform the operability tests required by §C(1) and (2) of this regulation at least annually; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Maintain the following records to show compliance with §C(1)—(3) of this regulation:</text>
          <paragraph num="(a)">
            <text>A list of each component tested;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Whether each component tested meets criteria specified or needs to have action taken; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A description of any action taken to correct an issue.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Notifications.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system shall notify the Department in accordance with COMAR 26.10.08.01 when a release detection method operated in accordance with one of the following performance standards indicates that a spill, release, or discharge may have occurred:</text>
          <paragraph num="(a)">
            <text>Regulation .05 of this chapter; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If the UST system has a field-constructed tank or an airport hydrant system, COMAR 26.10.12.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>If an owner, an operator, and a person in charge of a UST system changes the method of release detection used, the owner, the operator, and the person in charge of the UST system shall provide the Department written notification within 30 days of the change.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>An owner and an operator of a UST system that cannot apply a method of release detection that complies with the requirements of this chapter shall close the UST system in accordance with procedures in COMAR 26.10.10.</text>
      </paragraph>
      <paragraph num="F.">
        <text>An owner and an operator of a previously deferred UST system described in COMAR 26.10.02.01A(4)—(6) and COMAR 26.10.12 shall meet the requirements of this chapter not later than October 13, 2022.</text>
      </paragraph>
      <paragraph num="G.">
        <text>A person may not tamper with, or render inaccurate, any monitoring device or method required to be maintained under this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Requirements for UST Systems.">
      <paragraph num="A.">
        <text>An owner and an operator of a petroleum UST system or a hazardous substance UST system, unless otherwise provided in this regulation, shall provide release detection for USTs and piping as described in this regulation.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a UST system shall monitor the UST system for releases of a regulated substance by:</text>
        <paragraph num="(1)">
          <text>Conducting inventory control in accordance with Regulation .04 of this chapter; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At least monthly, conducting one of the methods of release detection described in Regulation .05B—H of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of a UST system with a UST capacity of 550 gallons or less and that is not metered may use weekly manual tank gauging conducted in accordance with Regulation .05C of this chapter as a method of release detection.</text>
      </paragraph>
      <paragraph num="D.">
        <text>Underground Piping.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system shall monitor underground piping that routinely contains petroleum vapor or a regulated substance in accordance with §D(2)—(4) of this regulation.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Pressurized Piping.</text>
          <paragraph num="(a)">
            <text>An owner and an operator of a UST system with underground piping that conveys regulated substances under pressure shall equip the underground piping with an automatic line leak detector that is tested annually in accordance with Regulation .01C of this chapter, and which will:</text>
            <paragraph num="(i)">
              <text>Alert the operator to the presence of a leak or a spill, release, or discharge by restricting or shutting off the flow of a regulated substance through piping or triggering an alarm; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Detect a leak or a spill, release, or discharge of a regulated substance of at least 3 gallons per hour at 10 pounds per square inch line pressure within 1 hour; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>An owner and an operator of a UST system with underground piping that conveys regulated substances under pressure shall:</text>
            <paragraph num="(i)">
              <text>At least annually, perform a precision tightness test on the piping for a minimum of 1 hour that is capable of detecting a 0.1 gallon per hour release at 1.5 times the pipe operating pressure; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>At least monthly, perform one of the methods of release detection described in Regulation .05B and F—H of this chapter.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Suction Piping.</text>
          <paragraph num="(a)">
            <text>An owner and an operator of a UST system with underground piping that conveys regulated substances under suction shall:</text>
            <paragraph num="(i)">
              <text>At least every 2 years, perform a precision tightness test on the piping for a minimum of 1 hour that is capable of detecting a 0.1 gallon per hour release at a pressure between 5 and 15 pounds per square inch; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>At least monthly, monitor for a spill, release, or discharge using one of the methods of release detection described in Regulation .05B and F—H of this chapter.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>An owner and an operator of a UST system with underground suction piping are not required to perform the release detection and precision tightness testing required in §D(3)(a) of this regulation on the piping when:</text>
            <paragraph num="(i)">
              <text>The piping operates at less than atmospheric pressure;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The piping is sloped so that the contents of the pipe will drain back into the UST if the suction is released;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A single check valve is included in each suction line;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The check valve is located directly below and as close as practicable to the suction pump; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>The owner and operator of the UST system provide a method of visual inspection to determine compliance with §D(3)(b)(ii)—(iv) of this regulation.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner and an operator of a UST system with secondary containment piping shall test that piping:</text>
          <paragraph num="(a)">
            <text>After completing installation of the piping but before operation of the UST system, for new, upgraded, or replaced piping;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>At least every 5 years, for piping installed on or after January 12, 2009; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>In accordance with manufacturer’s specifications or a method approved by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Requirements for Hazardous Substance UST Systems.">
      <paragraph num="A.">
        <text>In addition to the UST system requirements in Regulation .02 of this chapter, an owner and an operator of a hazardous substance UST system shall:</text>
        <paragraph num="(1)">
          <text>Provide containment that meets the requirements of this regulation; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Monitor the containment systems using interstitial monitoring pursuant to Regulation .05G of this chapter at least monthly.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a hazardous substance UST system shall ensure the hazardous substance UST system meets the following requirements:</text>
        <paragraph num="(1)">
          <text>A secondary containment system is designed, constructed, and installed to:</text>
          <paragraph num="(a)">
            <text>Contain hazardous substances spilled or released from the primary containment until the spill or release is detected and removed;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Prevent the spill, release, or discharge of hazardous substances to the environment at any time during the operational life of the UST system; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Be checked for evidence of a spill, release, or discharge at least monthly;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A double-walled UST is designed, constructed, and installed to:</text>
          <paragraph num="(a)">
            <text>Contain a release from any portion of the inner storage tank within the outer wall; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Detect the failure of the inner wall;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>An external liner, including a vault, is designed, constructed, and installed to:</text>
          <paragraph num="(a)">
            <text>Contain 100 percent of the capacity of the largest UST within its boundary;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Prevent precipitation or groundwater from entering the liner; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Surround the UST completely;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Underground piping is equipped with secondary containment that satisfies the requirements of §B(1)—(3) of this regulation; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Underground piping that conveys hazardous substances under pressure is equipped with an automatic line leak detector in accordance with Regulation .02D(2) of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of hazardous substance UST system may use other methods of release detection in conjunction with interstitial monitoring as required in §A(2) of this regulation if the owner and an operator of the UST system:</text>
        <paragraph num="(1)">
          <text>Demonstrates to the Department in writing that an alternate method can detect a release of the stored hazardous substance as effectively as any of the methods allowed in Regulation .05B—H of this chapter,</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Provides the Department with information regarding effective corrective action technologies, health risks, and chemical and physical properties of the stored hazardous substance, and the physical characteristics of the regulated substance storage facility; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Obtains approval from the Department to use the alternate release detection method before the installation and operation of the UST system.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Inventory Control.">
      <paragraph num="A.">
        <text>Inventory Variations.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system shall review the reconciled inventory records required by COMAR 26.10.04.01 for the following:</text>
          <paragraph num="(a)">
            <text>Inventory variations exceeding 1 percent plus 130 gallons of the metered quantity of a regulated substance each calendar month; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Daily inventory records that show 7 consecutive days of shortage totaling 80 gallons or more.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a UST system shall conduct a review of reconciled inventory records at the following frequencies:</text>
          <paragraph num="(a)">
            <text>Review inventory variation as required under §A(1)(a) of this regulation monthly; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Review daily inventory records as required under §A(1)(b) of this regulation daily.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Reporting and Investigating Inventory Variations.</text>
          <paragraph num="(a)">
            <text>An operator of a UST system shall report a variation or shortage as described in §A(1) of this regulation to the owner of the UST system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Upon discovery of an inventory variation, an owner and an operator of a UST system shall immediately investigate the cause of the variation or shortage;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>If the investigation required under §A(3)(b) of this regulation reveals no indication of a discharge or release from a UST system, an owner and an operator of a UST system shall state the cause of the inventory variation or shortage in the daily inventory records; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>If the investigation required under §A(3)(b) of this regulation reveals a discharge or release from a UST system, an owner and an operator of a UST system shall follow the procedures established under COMAR 26.10.08.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The Department may require an owner and an operator of a UST system to perform a precision tightness test of the UST system:</text>
        <paragraph num="(1)">
          <text>If the owner and the operator fail to reconcile daily inventory records as specified in COMAR 26.10.04.01 and review the reconciled records in accordance with §A of this regulation;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If the owner and the operator fail to comply with monthly release detection requirements of Regulation .05 of this chapter; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>For any other good cause as determined by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>The Department may require an owner and an operator of a UST system to perform a precision tightness test of the UST system and install monitoring wells or conduct a site assessment if there is reason to believe there is or may have been a discharge or release of a regulated substance from the UST system.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Method of Release Detection.">
      <paragraph num="A.">
        <text>In addition to the inventory control requirements in Regulation .04 of this chapter, an owner and an operator of a UST system shall perform one or a combination of the methods of release detection described in §§B—H of this regulation at least monthly.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Statistical Inventory Reconciliation. An owner and an operator of a UST system utilizing statistical inventory reconciliation as a monthly method of release detection:</text>
        <paragraph num="(1)">
          <text>May only use statistical inventory reconciliation if the UST system is a metered UST system;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Shall use statistical inventory reconciliation to detect a spill, release, or discharge through application of statistical principles to inventory data, or another test of equivalent performance, with a probability of detection of not less than 0.95 and a probability of false alarm of not more than 0.05;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Shall use a method of statistical inventory reconciliation that meets the following requirements:</text>
          <paragraph num="(a)">
            <text>Uses inventory volume measurements collected in accordance with COMAR 26.10.04.01;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Produces a quantitative result with a calculated leak rate;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Is capable of detecting:</text>
            <paragraph num="(i)">
              <text>A leak rate of 0.2 gallon per hour; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A spill, release, or discharge of 150 gallons within a month; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>Uses a threshold that does not exceed one-half the minimum detectible leak rate; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Shall have a Department-approved third party conduct the statistical inventory reconciliation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Manual Tank Gauging.</text>
        <paragraph num="(1)">
          <text>At least weekly, an owner and an operator of a UST system shall perform manual tank gauging using a storage tank gauging stick maintained in accordance with COMAR 26.10.04.01 as follows:</text>
          <paragraph num="(a)">
            <text>Take UST liquid level measurements at the beginning and ending of an at least 36-hour period, during which liquid may not be added to or removed from the UST;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Base the level measurements on an average of two consecutive stick readings at both the beginning and ending of the period; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Using a UST gauge chart specific to the UST gauged, convert the liquid levels to the gallons present in the UST and review for any variations between the starting and ending measurements.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a UST system shall report a suspected spill, release, or discharge and follow the investigation and confirmation procedures in COMAR 26.10.08 if the variation between beginning and ending manual tank gauging measurements performed in accordance with §C(1) of this regulation exceeds the weekly or monthly standards in the following table:</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner and an operator of a UST system may use manual tank gauging:</text>
          <paragraph num="(a)">
            <text>As the sole method of release detection if the nominal capacity of a UST is 550 gallons or less; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>For a UST with a nominal capacity of 551 to 2,000 gallons only in conjunction with conducting a precision tightness test, as defined in COMAR 26.10.02.02, at least every 5 years in accordance with the requirements of COMAR 26.10.03.05.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner and an operator of a UST system may not use manual tank gauging to meet the requirements of this chapter for a UST that has a nominal capacity of more than 2,000 gallons.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Precision Tightness Testing. At least monthly, an owner and an operator of a UST system shall conduct a precision tightness test, as defined in COMAR 26.10.02.02, as a method of release detection in accordance with the requirements of COMAR 26.10.03.05.</text>
      </paragraph>
      <paragraph num="E.">
        <text>Automatic Tank Gauging. At least monthly, an owner and an operator of a UST system shall perform automatic tank gauging using equipment that tests for the loss of regulated substance and conducts inventory control and that meets the following requirements:</text>
        <paragraph num="(1)">
          <text>The automatic regulated substance level monitor test is capable of detecting a 0.2 gallon per hour leak rate from any portion of the UST;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The automatic tank gauging equipment meets the inventory control, or another test of equivalent performance, requirements of COMAR 26.10.04.01, and Regulation .04 of this chapter; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An automatic tank gauging system tests for loss of a regulated substance by operating in one of the following modes:</text>
          <paragraph num="(a)">
            <text>In-tank static testing conducted at least once monthly; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Continuous in-tank leak detection operating on an uninterrupted basis or operating within a process that allows the automatic tank gauging system to gather incremental measurements to determine the leak status of the UST at least once monthly.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>Groundwater Monitoring.</text>
        <paragraph num="(1)">
          <text>Beginning June 13, 2022, an owner and an operator of a UST system may only use groundwater monitoring as a monthly method of release detection with prior written approval from the Department.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a UST system shall conduct groundwater monitoring in accordance with the following requirements:</text>
          <paragraph num="(a)">
            <text>Perform a site assessment 60 days before the implementation of the groundwater monitoring method;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Provide a written report of the site assessment to the Department upon request and, beginning June 13, 2022, ensure the written report is signed by a professional engineer or professional geologist, or equivalent licensed professional with experience in environmental engineering, hydrogeology, or other relevant technical discipline acceptable to the Department; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Demonstrate that the testing or monitoring to detect a regulated substance on the groundwater meets all of the following requirements:</text>
            <paragraph num="(i)">
              <text>The regulated substance stored is immiscible in water and has a specific gravity of less than one;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Groundwater is never more than 15 feet from the ground surface and the hydraulic conductivity of the soil or soils between the UST system and the monitoring wells or devices is not less than 0.01 centimeter/second, with the soil consisting of gravels, coarse to medium sands, coarse silts, or other permeable materials;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The slotted portion of the monitoring well casing is designed to prevent migration of natural soils or filter pack into the well and to allow entry of regulated substance on the water table into the well under both high and low groundwater conditions;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Monitoring wells are sealed from the ground surface to the top of the filter pack;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Monitoring wells or devices intercept the UST excavation zone or positioned as close to the excavation zone as is technically feasible;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>The method of measuring the contents of the well, whether automatic or manual, is capable of detecting the presence of at least 1/8 of an inch of free product on top of the groundwater in the monitoring wells;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>At least monthly, the contents of the groundwater monitoring well are measured;</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>Within and immediately below the UST system excavation zone, the site is assessed to ensure compliance with the requirements in §F(2)(c)(i)—(v) of this regulation and to establish the number and positioning of monitoring wells or devices that will detect discharges or releases from any portion of the UST system;</text>
            </paragraph>
            <paragraph num="(ix)">
              <text>Monitoring wells are clearly marked and secured to avoid unauthorized access and tampering; and</text>
            </paragraph>
            <paragraph num="(x)">
              <text>A key, a lock combination number, or access tool for all monitoring wells is provided to the Department upon request and made available on the site where the UST system is located.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>Interstitial Monitoring.</text>
        <paragraph num="(1)">
          <text>Beginning June 13, 2022, an owner and an operator of a UST system may only use interstitial monitoring as a monthly method of release detection between a UST system and a secondary barrier as described in §G(2)(b) of this regulation with prior written approval from the Department.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a UST system may use interstitial monitoring between the UST system and a secondary barrier immediately around or beneath the UST system as a method of release detection if the UST system is designed, constructed, and installed to detect a spill, release, or discharge from any portion of the UST system and one of the following conditions are met:</text>
          <paragraph num="(a)">
            <text>For a double-walled UST system, the owner and operator of the UST system uses a sampling or testing method that can detect a spill or release through the inner wall in any portion of the UST system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>For a UST system with a secondary barrier within the excavation zone, the owner or operator of the UST system uses a sampling or testing method that can detect a spill, release, or discharge between the UST system and the secondary barrier, provided that:</text>
            <paragraph num="(i)">
              <text>The secondary barrier around and beneath the UST system consists of artificially constructed material that is sufficiently thick and impermeable, at least 1×10-6 centimeter/second for the regulated substance stored, to direct a spill, release, or discharge to the monitoring point and allow the detection of the regulated substance;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The barrier is compatible with the regulated substance stored so that a spill, release, or discharge from the UST system will not cause a deterioration of the barrier and allow a spill, release, or discharge to pass through the barrier undetected;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>For cathodically protected UST systems, the owner and the operator installs a secondary barrier so that it does not interfere with the proper operation of the cathodic protection system;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The groundwater, soil moisture, or rainfall will not make the testing or sampling method used inoperative so that a spill, release, or discharge could go undetected for more than 30 consecutive days;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>The site is assessed to ensure that the secondary barrier is always above the groundwater and not in a 25-year flood plain, unless the barrier and monitoring designs are for use under these conditions; and</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Monitoring wells are clearly marked and secured with bolts or a lock to avoid unauthorized access and tampering; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>For USTs with an internally fitted liner, the owner and operator of the UST uses an automated device that can detect a spill or release between the inner wall of the UST and the liner, and the liner is compatible with the regulated substance stored.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>Other Methods.</text>
        <paragraph num="(1)">
          <text>Upon the approval of the Department, an owner and an operator of a UST system may use one or combination of alternative methods of monthly release detection if:</text>
          <paragraph num="(a)">
            <text>The method can detect a 0.2 gallon per hour leak rate or a release of 150 gallons within a month with a probability of detection of not less than 0.95 and a probability of false alarm of not more than 0.05; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The owner and the operator of the UST system can demonstrate to the Department that the method can detect a spill, release, or discharge as effectively as any of the methods allowed in §§B and D—G of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>If an alternative method of monthly release detection proposed by an owner and an operator of a UST system is approved by the Department, the owner and the operator of the UST system shall comply with any conditions imposed by the Department on the use of the method to ensure the protection of human health and the environment.</text>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>Vapor Monitoring. Except as provided in §H of this regulation, an owner and an operator of a UST system may not use vapor monitoring as a monthly method of release detection after April 1, 2009.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Release Detection Recordkeeping.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system shall maintain records demonstrating compliance with the applicable requirements of this chapter:</text>
        <paragraph num="(1)">
          <text>In accordance with COMAR 26.10.04.05;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>For at least 1 year at the regulated substance storage facility;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>For at least 5 years at a location designated by the owner of the UST system; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>That include the following information:</text>
          <paragraph num="(a)">
            <text>Written performance claims pertaining to any release detection system used, and the manner in which these claims have been justified or tested by the equipment manufacturer or installer;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The results of any sampling, testing, or monitoring including:</text>
            <paragraph num="(i)">
              <text>The results of annual operability tests required in Regulation .01C of this chapter; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The results of precision tightness testing conducted in accordance with Regulation .05D of this chapter; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Written documentation for all calibration, maintenance, and repair of release detection equipment permanently located on-site, and any schedules of required calibration and maintenance provided by the release detection equipment manufacturer.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a UST system shall maintain records of site assessments required under Regulation .05F of this chapter for as long as the groundwater monitoring method is used.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-411.2, 4-415.1, 4-417, 4-701 et seq., and 7-201 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective November 4, 1996 (23:22 Md. R. 1498)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01A amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02B amended effective June 29, 1998 (25:13 Md. R. 997)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02C amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02D amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04 amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04B amended effective June 29, 1998 (25:13 Md. R. 997)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04C amended effective February 18, 2002 (29:3 Md. R. 224); January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06 amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.06 repealed and new Regulations .01—.06 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="06" heading="UST System Technician, Remover, and Inspector Certification">
    <regulation prefix="Regulation" num=".01" heading="General.">
      <paragraph num="A.">
        <text>The Department may issue certifications to an individual for the following UST system categories:</text>
        <paragraph num="(1)">
          <text>A UST system technician certification that allows the individual to install, upgrade, repair, close, and perform a change-in-service of a UST system in accordance with the requirements in COMAR 26.10.01—26.10.10, 26.10.12, and 26.10.16;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A heating oil technician certification that allows the individual to only install, upgrade, repair, and close a UST system storing heating oil for consumptive use and with a capacity of 2,000 gallons or less in accordance with the requirements in COMAR 26.10.01—26.10.06 and 26.10.08—26.10.10;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A UST system remover certification that allows the individual to close and perform a change-in-service of a UST system in accordance with the requirements in COMAR 26.10.01, 26.10.02, 26.10.06, and 26.10.08—26.10.10; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>A UST system inspector certification that allows the individual to conduct a UST system inspection in accordance with COMAR 26.10.03.10.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>A certification issued by the Department to an individual under this chapter expires 2 years from the date of issuance.</text>
      </paragraph>
      <paragraph num="C.">
        <text>The Department may issue a UST system inspector certification and not more than one additional certification from the remaining categories listed in §A of this regulation to an individual provided the individual applies for the certifications in accordance with this chapter.</text>
      </paragraph>
      <paragraph num="D.">
        <text>An individual shall only perform UST system work for which the individual has received a certification from the Department.</text>
      </paragraph>
      <paragraph num="E.">
        <text>An individual certified by the Department under this chapter shall have proof of certification from the Department at all times while performing work on a UST system.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Initial Certification Requirements.">
      <paragraph num="A.">
        <text>To be certified as a UST system technician, an individual shall:</text>
        <paragraph num="(1)">
          <text>Submit a complete application in accordance with Regulation .03 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Meet the following experience requirements:</text>
          <paragraph num="(a)">
            <text>Have at least 2 years of UST system installation experience within the last 36 months with a company or organization that installs UST systems; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Have direct involvement in a minimum of six separate UST system installation, repair, upgrade, or closure events, where not more than three UST system closure events may be counted towards the six direct involvement events; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Achieve a score of 90 percent or better on the UST system technician certification test given by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>To be certified as a heating oil technician, an individual shall:</text>
        <paragraph num="(1)">
          <text>Submit a complete application in accordance with Regulation .03 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Meet the experience requirements listed in §A(2) of this regulation; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Achieve a score of 90 percent or better on the heating oil technician certification test given by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>To be certified as a UST system remover, an individual shall:</text>
        <paragraph num="(1)">
          <text>Submit a complete application in accordance with Regulation .03 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Have direct involvement in a minimum of six separate UST system closure events within the last 36 months with a company or organization that closes UST systems; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Achieve a score of 90 percent or better on the UST system remover certification test given by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>To be certified as a UST system inspector, an individual shall:</text>
        <paragraph num="(1)">
          <text>Submit a complete application in accordance with Regulation .03 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Meet the following experience requirements:</text>
          <paragraph num="(a)">
            <text>Attend and complete one or more nationally recognized or Department approved training courses, classes, examinations, or workshops pertaining to UST system design, installation, operation, testing, or inspection; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Attend a UST system inspector orientation course provided by the Department; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Achieve a score of 90 percent or better on the UST system inspector certification test given by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>The experience requirements in §§A(2), B(2), C(2), and D(2) of this regulation may be waived if the individual has equivalent training or education as determined by the Department.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Application and Testing.">
      <paragraph num="A.">
        <text>Application Process.</text>
        <paragraph num="(1)">
          <text>To apply for an initial or renewal UST system technician, heating oil technician, or UST system remover certification, an individual shall complete an application provided by the Department as follows:</text>
          <paragraph num="(a)">
            <text>As specified on the application, the individual shall submit verifiable proof of the experience requirements for the particular certification as required under:</text>
            <paragraph num="(i)">
              <text>Regulation .02A(2), B(2), or C(2) of this chapter for an initial certification; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Regulation .04A(2) of this chapter to renew a certification;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>The individual applying for certification and the employer of the individual shall sign the completed application; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The individual shall submit the completed application to the Department.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>To apply for an initial or to renew a UST system inspector certification, an individual shall complete an application provided by the Department as follows:</text>
          <paragraph num="(a)">
            <text>As specified on the application, the individual shall submit verifiable proof of the experience requirements as required under:</text>
            <paragraph num="(i)">
              <text>Regulation .02D(2) of this chapter for an initial certification; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Regulation .04B(2) of this chapter to renew a certification;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>The individual applying for certification and the employer of the individual shall sign the completed application; and;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The individual shall submit the completed application to the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Certification Testing.</text>
        <paragraph num="(1)">
          <text>At least 30 days prior to registering with the Department to take a certification test, an individual shall have submitted a completed application to the Department in accordance with §A of this regulation.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The Department shall publish certification testing dates on the Department’s website.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An individual shall register with the Department at least 72 hours prior to the scheduled test date to take a certification test.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>An individual shall present a valid government issued photo identification to the Department at the time of the certification test.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>An individual shall follow all directions provided by the Department in taking the certification test.</text>
        </paragraph>
        <paragraph num="(6)">
          <text>The Department may disqualify an individual from completing a certification test if the Department determines the individual is dishonestly taking the certification test.</text>
        </paragraph>
        <paragraph num="(7)">
          <text>In order to pass a certification test, an individual must achieve a score of 90 percent or better.</text>
        </paragraph>
        <paragraph num="(8)">
          <text>An individual who has not achieved a passing score on a certification test may register to retest within 90 days and without being required to reapply for a certification.</text>
        </paragraph>
        <paragraph num="(9)">
          <text>An individual who does not achieve a passing score on a certification test within 90 days of the first failed attempt shall submit a new application for a certification.</text>
        </paragraph>
        <paragraph num="(10)">
          <text>An individual may not count time taking a certification test toward the continuing education requirements under this chapter.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Certification Renewal Requirements.">
      <paragraph num="A.">
        <text>To renew a certification for a UST system technician, a heating oil technician, or a UST system remover, an individual shall:</text>
        <paragraph num="(1)">
          <text>At least 30 days prior to the expiration of the current certification, submit a complete application in accordance with Regulation .03 of this chapter; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Meet the following experience requirements:</text>
          <paragraph num="(a)">
            <text>Attend and complete a UST system course approved by the Department within the last 2 years; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Have direct involvement in a minimum of six separate UST system installation, repair, upgrade, or closure events.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>To renew a certification for a UST system inspector, an individual shall:</text>
        <paragraph num="(1)">
          <text>At least 30 days prior to the expiration of the current certification, submit a complete application in accordance with Regulation .03 of this chapter; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Meet the following experience requirements:</text>
          <paragraph num="(a)">
            <text>Attend and complete the following courses within the last 2 years:</text>
            <paragraph num="(i)">
              <text>At least one Department approved training program for compliance inspections of UST systems; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>An inspector orientation course or workshop provided by the Department; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Perform UST system inspections at a minimum of 10 regulated substance storage facilities within the last 2 years.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An individual shall renew a certification in accordance with Regulation .02 of this chapter if the individual fails to:</text>
        <paragraph num="(1)">
          <text>Submit a complete application at least 30 days prior to the expiration date of the current certification; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Demonstrate compliance with the experience requirements in §A(2) or B(2) of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>An individual may elect to renew a certification in accordance with Regulation .02 of this chapter.</text>
      </paragraph>
      <paragraph num="E.">
        <text>If an individual is required to renew a UST system inspector certification in accordance with §C of this regulation or elects to renew a UST system inspector certification in accordance with Regulation .02 of this chapter, the individual is not required to meet the experience requirement in Regulation .02D(2)(a) of this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Reciprocity Certification.">
      <paragraph num="A.">
        <text>The Department may issue a reciprocity certification for one of the four categories listed in Regulation .01A of this chapter to an individual who has a valid certification issued by another state if the Department determines that the state has a comparable certification program to the requirements of this chapter.</text>
      </paragraph>
      <paragraph num="B.">
        <text>To obtain reciprocity certification, an individual shall:</text>
        <paragraph num="(1)">
          <text>Submit a valid certification from another state to the Department;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Complete an application provided by the Department in accordance with Regulation .03 of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Meet the experience requirements as follows:</text>
          <paragraph num="(a)">
            <text>An individual applying for a UST system technician, heating oil technician, or UST system remover reciprocity certification shall meet the experience requirements in Regulation .02 of this chapter; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An individual applying for a UST system inspector reciprocity certification shall meet the following experience requirements:</text>
            <paragraph num="(i)">
              <text>Perform UST system inspections at a minimum of 10 regulated substance storage facilities within the last 2 years; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Attend and complete an inspector orientation course provided by the Department; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Achieve a score of 90 percent or better on a certification test given by the Department for that certification.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An individual receiving a reciprocity certification issued under this chapter shall be subject to the requirements under COMAR 26.10.</text>
      </paragraph>
      <paragraph num="D.">
        <text>An individual renewing a reciprocity certification issued under this chapter shall follow the renewal requirements in Regulation .04 of this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Standards of Performance.">
      <text>An individual certified by the Department under this chapter shall:</text>
      <paragraph num="A.">
        <text>Maintain knowledge of COMAR 26.10.01—26.10.12 and 26.10.16 and all documents incorporated by reference;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Adhere to equipment manufacturers’ instructions, accepted industry standards, and applicable industry codes of practice when performing UST system installation, repair, upgrade, closure, change-in-service, precision tightness testing, other tightness testing, or inspection activities;</text>
      </paragraph>
      <paragraph num="C.">
        <text>Perform work so that there is no spill, release, or discharge of regulated substances or contamination of soil, surface water, or groundwater caused by regulated substances from a UST system or regulated substance storage facility;</text>
      </paragraph>
      <paragraph num="D.">
        <text>Certify to an owner or an operator of a UST system that a UST system installation, upgrade, repair, closure, change-in-service, or inspection is complete only when the activity conducted by the individual complies with COMAR 26.10.01—26.10.12 and 26.10.16;</text>
      </paragraph>
      <paragraph num="E.">
        <text>Complete and submit to the Department a form provided by the Department that certifies a UST system installation, closure, change-in-service, or inspection activity conducted by the individual meets the requirements of COMAR 26.10.01—26.10.12 and 26.10.16;</text>
      </paragraph>
      <paragraph num="F.">
        <text>Place the individual’s signature and Department issued certification number on documentation concerning an installation, upgrade, repair, closure, change-in-service, or inspection of a UST system or component of a UST system only if:</text>
        <paragraph num="(1)">
          <text>The certified individual directly completed the work or the work was completed under the certified individual’s direct, on-site supervision and control; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The individual had a valid certification issued by the Department to conduct the specific work at the time the work was performed;</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>Maintain complete records of UST system installation, upgrade, repair, closure, change-in-service, and inspection activities that the certified individual was directly involved with for a minimum of 5 years; and</text>
      </paragraph>
      <paragraph num="H.">
        <text>Upon request by the Department, provide proof of the individual’s certification for the UST system services being provided.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Conflict of Interest.">
      <paragraph num="A.">
        <text>A certified UST system inspector may not perform, and an owner and an operator of a UST system may not allow, a UST system inspector to perform an inspection on a UST system for compliance with COMAR 26.10.03.10 if the UST system inspector is also:</text>
        <paragraph num="(1)">
          <text>The owner or the operator of the UST system to be inspected;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An employee of the owner or the operator of the UST system to be inspected; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The certified UST system technician who completed the installation, replacement, or upgrade work on the UST system to be inspected.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The Department shall refuse a UST system inspection report submitted in compliance with COMAR 26.10.03.10D if the UST system inspector who performed the inspection and signed and provided their Department issued certification number on the inspection report is also one of the individuals identified in §A of this regulation.</text>
      </paragraph>
      <paragraph num="C.">
        <text>A certified UST system inspector who is also a certified UST system technician may correct deficiencies while performing an inspection on a UST system in compliance with COMAR 26.10.03.10.</text>
      </paragraph>
      <paragraph num="D.">
        <text>A certified UST system inspector shall be subject to the actions available to the Department as stated in Regulation .08 and .09 of this chapter if the individual performed the inspection and signed and provided their Department issued certification number on the inspection report refused by the Department under §B of this regulation.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Denial, Suspension, or Revocation.">
      <paragraph num="A.">
        <text>The Department may deny an application for certification if an individual has not complied with the application and experience requirements in Regulations .02—.04 of this chapter or has demonstrated a history of noncompliance with the provisions of COMAR 26.10, including the reasons listed in §B(1) of this regulation.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Suspension or Revocation.</text>
        <paragraph num="(1)">
          <text>The Department may suspend or revoke a certification of an individual if the Department determines that the individual has done one or more of the following:</text>
          <paragraph num="(a)">
            <text>Demonstrated a willful or negligent disregard or repeated violations of the regulations in this subtitle;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Willfully or negligently submitted false information to the Department;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Violated the requirements of Regulation .06 or .07 of this chapter; or</text>
          </paragraph>
          <paragraph num="(d)">
            <text>After a prior suspension or revocation of a certification under this chapter, committed an act in violation of COMAR 26.10.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An individual shall surrender all State certification documents obtained under this chapter to the Department upon notification of suspension or revocation.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The Department may suspend or revoke a certification obtained under this chapter in accordance with State Government Article, §10-226, Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Contested Case Hearing.</text>
        <paragraph num="(1)">
          <text>Except as otherwise provided in COMAR 26.10.01.24, an individual shall have an opportunity for a contested case hearing if the individual files a written request with the Department within 30 calendar days of receiving:</text>
          <paragraph num="(a)">
            <text>A notice of the Department’s decision to deny the certification application or to suspend or revoke the individual’s certification, as provided in §§A and B of this regulation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A notice or order issued by the Department regarding a violation of a provision of this chapter or COMAR 26.10.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The Department shall conduct a contested case hearing in accordance with the provisions under State Government Article, Title 10, Subtitle 2, Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".09" heading="Sanctions.">
      <paragraph num="A.">
        <text>An individual whose certification has been revoked may not apply for a new certification for 2 years from the date of revocation.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An individual is subject to the sanctions set forth in Environment Article, Title 4, Subtitle 4 and Title 7, Subtitle 2, Part VIII, Annotated Code of Maryland if that individual:</text>
        <paragraph num="(1)">
          <text>Violates any provision of this chapter; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Does not install, upgrade, repair, close, perform a change-in-service of, or inspect a UST system in accordance with the provisions of COMAR 26.10.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-411.2, 4-415.1, 4-417, 4-701 et seq., and 7-201 et seq.; State Government Article, §§10-206 and 10-226; Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective November 4, 1996 (23:22 Md. R. 1498)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 amended effective February 18, 2002 (29:3 Md. R. 224); January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02 amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02A, B amended effective December 21, 2015 (42:25 Md. R. 1547)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03 amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03A amended effective June 29, 1998 (25:13 Md. R. 997); December 21, 2015 (42:25 Md. R. 1547)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03C amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03D repealed effective December 21, 2015 (42:25 Md. R. 1547)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04 amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04A amended effective January 12, 2009 (36:1 Md. R. 25); December 21, 2015 (42:25 Md. R. 1547)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05 amended effective January 16, 2006 (33:1 Md. R. 39); December 21, 2015 (42:25 Md. R. 1547)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06 amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07 amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .08 amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09 amended effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09B amended effective June 29, 1998 (25:13 Md. R. 997)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09B, C amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09D repealed effective December 21, 2015 (42:25 Md. R. 1547)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .10 adopted effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .10C repealed effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .11 adopted effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .12 adopted effective January 16, 2006 (33:1 Md. R. 39)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .12B amended effective December 21, 2015 (42:25 Md. R. 1547)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.12 repealed and new Regulations .01—.09 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="07" heading="High Risk Oil Storage Facilities">
    <regulation prefix="Regulation" num=".01" heading="Scope.">
      <paragraph num="A.">
        <text>Applicability.</text>
        <paragraph num="(1)">
          <text>The requirements of this chapter apply only to the following oil storage facilities:</text>
          <paragraph num="(a)">
            <text>An oil storage facility with a new or existing gasoline UST system located in a high risk groundwater use area (HRGUA) or well head protection area (WHPA); and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An oil storage facility that meets the definition of a high risk underground oil storage facility under Regulation .07A of this chapter.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>In addition to the requirements of this chapter, an owner of a new or existing gasoline UST system and an owner of a high risk underground oil storage facility is subject to the requirements under COMAR 26.10.01—26.10.06, 26.10.08—26.10.12, and 26.10.16.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Variances.</text>
        <paragraph num="(1)">
          <text>The Department may grant an owner of a new or existing gasoline UST system or a high risk underground oil storage facility a variance from one or more requirements of this chapter if the owner demonstrates the UST system or oil storage facility is not a threat to groundwater.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner applying for a variance provided under §B(1) of this regulation shall submit to the Department the following information:</text>
          <paragraph num="(a)">
            <text>A survey of groundwater use within a 1/2 mile radius of the oil storage facility;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A description of the construction materials used for the UST system;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A description of the release detection methods used to protect groundwater;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>A description of operation and testing methods used to protect groundwater; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Any other information requested by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Definitions.">
      <paragraph num="A.">
        <text>In this chapter:</text>
        <paragraph num="(1)">
          <text>A term in §B of this regulation has the meaning indicated; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A term not defined in §B of this regulation has:</text>
          <paragraph num="(a)">
            <text>The meaning given to the term in a relevant statute or in COMAR 26.10.01 or 26.10.02; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If not defined in a relevant statute or COMAR 26.10.01 or 26.10.02, the meaning attributed by common use.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>“Existing gasoline UST system” means a UST system located in a HRGUA or WHPA:</text>
          <paragraph num="(a)">
            <text>Installed before:</text>
            <paragraph num="(i)">
              <text>January 26, 2005, if located in a HRGUA; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>January 1, 2010, if located in a WHPA;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Containing gasoline, including gasohol, that is used to fuel motor vehicles; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>That has a storage capacity greater than 2,000 gallons.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>“High risk groundwater use area” or “HRGUA” means an area with a new or existing gasoline UST system:</text>
          <paragraph num="(a)">
            <text>In which an individual water supply system, as defined in COMAR 26.04.03.01-1B, serves as the water supply for the new or existing gasoline UST system facility, an adjoining property of the new or existing gasoline UST system facility, or both; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Located in:</text>
            <paragraph num="(i)">
              <text>Baltimore, Carroll, Cecil, Frederick, or Harford County; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Anne Arundel, Baltimore, Carroll, Cecil, Frederick, or Harford County for the purpose of notifying a property owner of groundwater contamination in accordance with Environment Article, §4-411.2, Annotated Code of Maryland.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>“High risk underground oil storage facility” means an oil storage facility that meets the conditions defined in Regulation .07A of this chapter.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>“Levels of concern” means:</text>
          <paragraph num="(a)">
            <text>Benzene at (=) 5 parts per billion;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Toluene at (=) 1,000 parts per billion;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Ethylbenzene at (=) 700 parts per billion;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Total xylenes at (=) 10,000 parts per billion; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Methyl tertiary butyl ether (MTBE) at (=) 20 parts per billion.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>“Local government” means a county, municipal corporation, or sanitary district.</text>
        </paragraph>
        <paragraph num="(6)">
          <text>“New gasoline UST system” means a UST system, including a replacement UST system, located in a HRGUA or WHPA:</text>
          <paragraph num="(a)">
            <text>Installed on or after:</text>
            <paragraph num="(i)">
              <text>January 26, 2005, if located in a HRGUA; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>January 1, 2010, if located in a WHPA; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Containing gasoline, including gasohol, that is used to fuel motor vehicles.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>“Well” means a hole made in the ground to obtain or monitor groundwater.</text>
        </paragraph>
        <paragraph num="(8)">
          <text>“Well head protection area” or “WHPA” means an area in Baltimore, Carroll, Cecil, Frederick, or Harford County identified and regulated by a local government surrounding one or more wells serving a:</text>
          <paragraph num="(a)">
            <text>Community water system, as defined by COMAR 26.04.01.01B; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Public water system, as defined by COMAR 26.04.01.01B.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="New Gasoline UST System.">
      <text>An owner of a new gasoline UST system, except for a new gasoline UST system in a HRGUA located in Anne Arundel County, shall:</text>
      <paragraph num="A.">
        <text>Comply with the following release prevention and detection requirements for a newly installed UST system:</text>
        <paragraph num="(1)">
          <text>If installing Stage II vapor recovery piping, install the Stage II vapor recovery piping in accordance with COMAR 26.10.03.02;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Install and utilize an interstitial release detection system for the UST system piping approved by the National Work Group on Leak Detection Evaluations;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If the UST system has a storage capacity of greater than 2,000 gallons or there are multiple USTs installed in a shared excavation zone:</text>
          <paragraph num="(a)">
            <text>Install four monitoring pipes in accordance with the specifications in COMAR 26.10.03.04B, with one monitoring pipe located in each corner of the excavation zone; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In conjunction with the monitoring pipes required under §A(3)(a) of this regulation, install a piping system that is designed to allow for active ventilation of the excavation zone; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Select and, upon receipt of Department approval, install one of the following systems to detect a spill, release, or discharge of gasoline liquid and vapors from the UST system:</text>
          <paragraph num="(a)">
            <text>A minimum of three monitoring wells that are:</text>
            <paragraph num="(i)">
              <text>Constructed in accordance with COMAR 26.04.04 and Department specifications;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Located outside of the excavation zone;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>In locations that will allow for the determination of groundwater flow; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Placed in areas that are most likely to detect a spill, release, or discharge from the UST system;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>A pressure control system that:</text>
            <paragraph num="(i)">
              <text>Is continuously operated;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Continuously monitors storage tank pressure;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Maintains storage tank pressure at an average negative pressure; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Prevents the release of gasoline vapors to the environment;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>If the UST system excavation zone meets the conditions of §A(3) of this regulation by either having a storage capacity of greater than 2,000 gallons or multiple USTs installed in a shared excavation zone, a soil vapor extraction system that is:</text>
            <paragraph num="(i)">
              <text>Connected to the monitoring pipes and piping system required under §A(3) of this regulation; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Operated continuously to maintain active ventilation of the excavation zone; or</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>An alternative method that will detect a spill, release, or discharge of gasoline liquid and vapors from the UST system;</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Within 30 days of installing a UST system, and annually thereafter:</text>
        <paragraph num="(1)">
          <text>Sample each site supply well and groundwater monitoring well located at the oil storage facility using a method approved by the Department; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Analyze each collected water sample in accordance with Regulation .05 of this chapter;</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Within 60 days after conducting a sample collection in accordance with §B of this regulation, submit the following documents to the Department:</text>
        <paragraph num="(a)">
          <text>A complete laboratory report that includes a copy of the laboratory sample acceptance form, sample chain-of-custody, and laboratory analytical results; and</text>
        </paragraph>
        <paragraph num="(b)">
          <text>A site map identifying each site supply well and groundwater monitoring well located at the oil storage facility; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Upon completing the installation, replacement, repair, or upgrade of a UST system and before placing the UST system in operation:</text>
        <paragraph num="(1)">
          <text>Test all primary piping that does not contain liquid gasoline, tank top fittings, Stage II piping, riser pipes, and vent piping using a helium pressure test, or other test approved by the Department, in accordance with procedures prescribed by the Department;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If leaks or deficiencies are found during the testing, make necessary repairs in accordance with COMAR 26.10.04.04; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Upon completion of a repair, retest the UST system in accordance with §D(1) of this regulation to ensure the UST system does not leak.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Existing Gasoline UST System.">
      <paragraph num="A.">
        <text>An owner of an existing gasoline UST system in a HRGUA, except for an existing gasoline UST system located in Anne Arundel County, shall:</text>
        <paragraph num="(1)">
          <text>Not later than July 25, 2005, implement the following release detection methods:</text>
          <paragraph num="(a)">
            <text>Sample each site supply well and any existing groundwater monitoring wells located on the oil storage facility;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Install a minimum of three groundwater monitoring wells that are:</text>
            <paragraph num="(i)">
              <text>Constructed in accordance with COMAR 26.04.04 and Department specifications;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Outside of the excavation zone;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>In locations that will allow for the determination of groundwater flow; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Placed in areas that are most likely to detect a spill, release, or discharge from the UST system;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Sample each groundwater monitoring well installed pursuant to §A(1)(b) of this regulation; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Analyze each water sample collected pursuant to §A(1)(a) and (c) of this regulation in accordance with Regulation .05 of this chapter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>On an annual basis, collect and analyze water samples from each site supply well and groundwater monitoring well in accordance with §A(1)(a), (c) and (d) of this regulation;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Within 60 days after conducting a sample collection pursuant to §A(1) or (2) of this regulation, submit the following documents to the Department:</text>
          <paragraph num="(a)">
            <text>A complete laboratory report that includes a copy of the laboratory sample acceptance form, sample chain-of-custody, and laboratory analytical results; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A site map identifying each site supply well and groundwater monitoring well located on the oil storage facility; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Except for a UST system with Stage II piping decommissioned using a method approved by the Department, not later than January 26, 2006, and on a 24-month basis thereafter, test the UST system in accordance with the following procedures:</text>
          <paragraph num="(a)">
            <text>Test all primary piping that does not contain liquid gasoline, tank top fittings, Stage II piping, riser pipes, and vent piping using a helium pressure test, or other test approved by the Department, in accordance with procedures prescribed by the Department;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If leaks or deficiencies are found during the testing, make necessary repairs in accordance with COMAR 26.10.04.04; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Upon completion of a repair, retest the UST system in accordance with §A(4)(a) of this regulation to ensure the UST system does not leak.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner of an existing gasoline UST system in a WHPA shall:</text>
        <paragraph num="(1)">
          <text>Not later than January 1, 2010, implement the following release detection methods:</text>
          <paragraph num="(a)">
            <text>Sample any existing groundwater monitoring well, and if present, site supply well located on the oil storage facility;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Install a minimum of three groundwater monitoring wells that are:</text>
            <paragraph num="(i)">
              <text>Constructed in accordance with COMAR 26.04.04 and Department specifications;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Outside of the excavation zone;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>In locations that will allow for the determination of groundwater flow; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Placed in areas that are most likely to detect a spill, release, or discharge from the UST system;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Sample each groundwater monitoring well installed pursuant to §B(1)(b) of this regulation; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Analyze each water sample collected pursuant to §B(1)(a) and (c) of this regulation in accordance with Regulation .05 of this chapter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>On an annual basis, collect and analyze water samples from each groundwater monitoring well, and if present, site supply well in accordance with §B(1)(a), (c) and (d) of this regulation;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Within 60 days after conducting a sample collection pursuant to §B(1) or (2) of this regulation, submit the following documents to the Department:</text>
          <paragraph num="(a)">
            <text>A complete laboratory report that includes a copy of the laboratory sample acceptance form, sample chain-of-custody, and laboratory analytical results; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A site map identifying each groundwater monitoring well, and if present, site supply well located on the oil storage facility; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Except for a UST system with Stage II piping decommissioned using a method approved by the Department, not later than January 1, 2010, and on a 24-month basis thereafter test the UST system in accordance with the following procedures:</text>
          <paragraph num="(a)">
            <text>Test all primary piping that does not contain liquid gasoline, tank top fittings, Stage II piping, riser pipes, and vent piping using a helium pressure test, or other test approved by the Department, in accordance with procedures prescribed by the Department;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If leaks or deficiencies are found during the testing, make necessary repairs in accordance with COMAR 26.10.04.04; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Upon completion of a repair, retest the UST system in accordance with §B(4)(a) of this regulation to ensure the UST system does not leak.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Analytical Testing Methods — New or Existing Gasoline UST Systems.">
      <text>An owner of a new or existing gasoline UST system shall conduct an analysis for full suite volatile organic compounds, including naphthalene and fuel oxygenates, for each water sample collected from:</text>
      <paragraph num="A.">
        <text>A groundwater monitoring well in accordance with USEPA Test Method 8260 or another method approved by the Department; and</text>
      </paragraph>
      <paragraph num="B.">
        <text>A site supply well in accordance with USEPA Test Method 524.2 or another method approved by the Department.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Detection of Levels of Concern.">
      <text>If the concentration of benzene, toluene, ethylbenzene, total xylenes, or MTBE is detected at equal to or greater than the levels of concern defined in Regulation .02B of this chapter in a groundwater sample collected and analyzed in accordance with Regulations .03—.05 of this chapter, an owner of a new or existing gasoline UST system shall:</text>
      <paragraph num="A.">
        <text>Within 24 hours of receiving an analytical laboratory report that shows the detection, report the sampling results to the Department;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Within 48 hours of receiving an analytical laboratory report that shows the detection, initiate an investigation both on-site and off-site of the oil storage facility in accordance with COMAR 26.10.08.02—.04; and</text>
      </paragraph>
      <paragraph num="C.">
        <text>In accordance with COMAR 26.10.09.07, develop a corrective action plan under the direction of the Department.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="High Risk Underground Oil Storage Facility.">
      <paragraph num="A.">
        <text>Defining a High Risk Underground Oil Storage Facility.</text>
        <paragraph num="(1)">
          <text>An oil storage facility is defined as a high risk underground oil storage facility under this chapter if the facility has:</text>
          <paragraph num="(a)">
            <text>An underground storage capacity that includes:</text>
            <paragraph num="(i)">
              <text>One or more UST systems constructed with a single-walled UST or single-walled product piping; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A total underground oil storage capacity of 80,000 gallons or greater, not including underground oil storage capacity used to store heating oil for onsite consumptive use; or</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>As determined by a throughput review conducted in accordance with §A(2) of this regulation, a combined monthly oil throughput for all products stored in UST systems of:</text>
            <paragraph num="(i)">
              <text>750,000 gallons or more when averaged over a rolling 12-month period; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>1,000,000 gallons or more in any single month.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Throughput Review Procedures.</text>
          <paragraph num="(a)">
            <text>To determine if an underground oil storage facility meets the definition of a high risk underground oil storage facility on a throughput basis, an owner of an underground oil storage facility shall have a throughput review performed in accordance with §A(2)(b) of this regulation:</text>
            <paragraph num="(i)">
              <text>At least once every three years during a certified inspection of a UST system required under COMAR 26.10.03.10; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If directed by the Department to perform a throughput review.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Using a form provided by the Department, a certified UST system inspector or a person in charge of an underground oil storage facility performing a throughput review shall determine the combined monthly oil throughput for all products by evaluating inventory records that document:</text>
            <paragraph num="(i)">
              <text>The average combined monthly oil throughput for all products over the preceding 12 months; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The highest combined monthly oil throughput for all products in the preceding 12 months.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>An owner of an underground oil storage facility shall submit to the Department the throughput review:</text>
            <paragraph num="(i)">
              <text>As part of the inspection report required under COMAR 26.10.03.10D if the throughput review was performed during a certified inspection of a UST system; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>As directed by the Department.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner of a high risk underground oil storage facility may demonstrate that the oil storage facility no longer meets the definition of a high risk underground oil storage facility by submitting documentation, such as an updated throughput review, to the Department that proves the oil storage facility no longer meets the conditions under §A(1) of this regulation.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Upon review of documentation provided to the Department pursuant to §A(3) of this regulation, the Department may determine:</text>
          <paragraph num="(a)">
            <text>The oil storage facility no longer meets the definition of a high risk underground oil storage facility; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The owner of the oil storage facility is no longer required to comply with the requirements of this regulation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Compliance with Monitoring Methods. An owner of a high risk underground oil storage facility shall:</text>
        <paragraph num="(1)">
          <text>Select, and upon receipt of Department approval, implement one of the following monitoring methods:</text>
          <paragraph num="(a)">
            <text>Groundwater monitoring method specified under §C of this regulation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Enhanced testing method specified under §D of this regulation; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>An alternative monitoring method specified under §E of this regulation; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Begin implementing the monitoring method in accordance with the following schedule:</text>
          <paragraph num="(a)">
            <text>Within 6 months of June 13, 2022, if the facility meets the size and construction conditions of §A(1)(a) of this regulation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Within 6 months of determining that the facility meets the throughput conditions of §A(1)(b) of this regulation; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>On a schedule determined by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Groundwater Monitoring Method. An owner of a high risk underground oil storage facility choosing to implement the groundwater monitoring method shall:</text>
        <paragraph num="(1)">
          <text>Install a minimum of three groundwater monitoring wells:</text>
          <paragraph num="(a)">
            <text>That are constructed in accordance with the well construction requirements of COMAR 26.04.04 and Department specifications;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Outside of the excavation zone;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>In locations that will allow for the determination of groundwater flow; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>In areas that are most likely to detect a spill, release, or discharge from the UST system;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Within 60 days of installing the groundwater monitoring wells, and annually thereafter:</text>
          <paragraph num="(a)">
            <text>Sample each groundwater monitoring well and analyze collected samples:</text>
            <paragraph num="(i)">
              <text>For full suite volatile organic compounds, including naphthalene and fuel oxygenates, in accordance with USEPA Test Method 8260 or another method approved by the Department; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>For total petroleum hydrocarbons, including diesel and gasoline range organics, in accordance with USEPA Test Method 8015 or another method approved by the Department; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>If present at the high risk underground oil storage facility, sample each site supply well and analyze collected samples for full suite volatile organic compounds, including naphthalene and fuel oxygenates, in accordance with USEPA Test Method 524.2 or another method approved by the Department; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Within 60 days after conducting a sample collection required under §C(2) of this regulation, submit the following documents to the Department:</text>
          <paragraph num="(a)">
            <text>A complete laboratory report that includes a copy of the laboratory sample acceptance form, sample chain-of-custody, and laboratory analytical results; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A site map identifying each site supply well and groundwater monitoring well located at the oil storage facility.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Enhanced Testing Method.</text>
        <paragraph num="(1)">
          <text>This method may only be implemented by an owner of a high risk underground oil storage facility if all of the UST systems at the facility are installed with double-walled USTs and all of the piping systems are installed in accordance with COMAR 26.10.03.02A.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner of a high risk underground oil storage facility choosing to implement the enhanced testing method shall:</text>
          <paragraph num="(a)">
            <text>Perform UST and piping release detection by interstitial monitoring and perform at least one additional method of UST release detection in accordance with COMAR 26.10.05;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Perform annual primary line precision tightness testing;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Perform annual piping interstice precision tightness testing;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Equip all containment sumps, except the vent riser containment sump, with sensors programmed for positive UST system dispensing and pumping shut down; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Every three years or at an alternative frequency under the direction of the Department, perform precision tightness testing of:</text>
            <paragraph num="(i)">
              <text>The UST in a manner that minimizes isolation of UST system components, such as the vent and vapor piping and risers, to the greatest extent possible; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The UST interstice, except for a brine filled interstice.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Alternative Monitoring Method. Subject to Department approval, an owner of a high risk underground oil storage facility may implement an alternative monitoring method if the owner demonstrates the alternative method is designed to detect a spill, release, or discharge from the UST system in a manner that is not less protective of human health and the environment than a method described under §C or D of this regulation.</text>
      </paragraph>
      <paragraph num="F.">
        <text>If an owner of a high risk underground oil storage facility detects a spill, release, or discharge at the facility, the owner shall comply with the spill, release, or discharge reporting and corrective action requirements of COMAR 26.10.08 and 26.10.09.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Recordkeeping.">
      <text>An owner of a new or existing gasoline UST system and an owner of a high risk underground oil storage facility shall:</text>
      <paragraph num="A.">
        <text>Maintain records of all testing required by this chapter for one year at the oil storage facility and for five years at a location designated by the owner; and</text>
      </paragraph>
      <paragraph num="B.">
        <text>Make the records maintained pursuant to §A of this regulation available to the Department upon request or as required under this chapter.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-411.2, 4-415.1, 4-417, and 4-701 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective November 4, 1996 (23:22 Md. R. 1498)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 repealed and new Regulations .01—.08 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="08" heading="Spill, Release, and Discharge Reporting, Investigation, and Confirmation">
    <regulation prefix="Regulation" num=".01" heading="Reporting of Suspected Spills, Releases, and Discharges.">
      <paragraph num="A.">
        <text>An owner and an operator of a storage tank system, a responsible party, and a person conducting a test on a storage tank system shall report to the Department a suspected spill, release, or discharge immediately, but not later than 2 hours after the discovery, and follow the investigation and confirmation procedures in Regulation .03 of this chapter if any of the following circumstances occur:</text>
        <paragraph num="(1)">
          <text>There is evidence of a spill, release, or discharge of oil;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>There is evidence of a spill, release, or discharge of a regulated substance from a UST system;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A storage tank system fails a precision tightness test;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>A storage tank system has two consecutive inconclusive precision tightness test results;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>A storage tank system is determined to have a leak or there is evidence of a spill, release, or discharge of oil at an oil storage facility or oil handling facility, such as the presence of:</text>
          <paragraph num="(a)">
            <text>Dissolved product in groundwater;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Absorbed product in soils;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Free product in soils, a basement, a sewer or utility line, or waters of the State; or</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Vapors in soils, a basement, a sewer or utility line, or waters of the State;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>There is evidence of a spill, release, or discharge at a regulated substance storage facility or in the surrounding area, such as the presence of:</text>
          <paragraph num="(a)">
            <text>Dissolved product in groundwater;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Absorbed product in soils;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Free product in soils, a basement, a sewer or utility line, or waters of the State; or</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Vapors in soils, a basement, a sewer or utility line, or waters of the State;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>Unusual operating conditions exist, such as:</text>
          <paragraph num="(a)">
            <text>The erratic behavior of product-dispensing equipment;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The sudden loss of a regulated substance from a storage tank system;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>An unexplained presence of water in a storage tank;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Liquid in the interstice space of secondarily contained systems; or</text>
          </paragraph>
          <paragraph num="(e)">
            <text>A failed spill prevention equipment or containment sump test for tightness; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(8)">
          <text>Monitoring results, including investigation of an alarm, from a release detection method required under COMAR 26.10.05 indicate a spill, release, or discharge may have occurred, unless:</text>
          <paragraph num="(a)">
            <text>The monitoring device is found to be defective and immediately repaired, recalibrated or replaced; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Additional monitoring does not confirm the initial result.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Additional Reporting Circumstances.</text>
        <paragraph num="(1)">
          <text>For the purposes of this section, evidence of a spill, release, or discharge include:</text>
          <paragraph num="(a)">
            <text>The visual detection of free product; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An analytical laboratory report that shows a detection of a petroleum constituent in a soil, groundwater, drinking water, or soil vapor sample at a concentration equal to or exceeding a cleanup standard or action level published by the Department for the petroleum constituent and media type.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>If evidence of a spill, release, or discharge is discovered during an environmental assessment conducted on a property as part of a due diligence investigation in support of a property transaction or a loan refinancing, the person conducting the environmental assessment and the owner of the property shall report the suspected spill, release, or discharge to the Department:</text>
          <paragraph num="(a)">
            <text>Immediately, but not later than 2 hours after the visual detection of free product; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Within 48 hours of receiving an analytical laboratory report described under §B(1) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>The person performing an environmental assessment on a property or the owner of the property may not be considered a person responsible for the discharge solely as a result of discovering evidence of a spill, release, or discharge or reporting a suspected spill, release, or discharge to the Department in compliance with §B(1) of this regulation, unless the person performing the environmental assessment or the property owner meets the criteria for a person responsible for the discharge under COMAR 26.10.01.02B.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Investigation Due to Off-Site Impacts.">
      <paragraph num="A.">
        <text>When directed by the Department, an owner and an operator of a storage tank system and a responsible party shall follow the investigation and confirmation procedures in Regulation .03 of this chapter to determine if the storage tank system or another source under the control of the owner and the operator of the storage tank system or the responsible party is the source of off-site impacts that have been:</text>
        <paragraph num="(1)">
          <text>Observed by the Department; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Brought to the Department’s attention by another party.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The off-site impacts subject to an investigation under §A of this regulation include, but are not limited to:</text>
        <paragraph num="(1)">
          <text>Dissolved product in groundwater;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Absorbed product in soils;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Free product in soils, a basement, a sewer or utility line, or waters of the State; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Vapors in soils, a basement, a sewer or utility line, or waters of the State.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Investigation and Confirmation Steps.">
      <paragraph num="A.">
        <text>Unless corrective action is initiated in accordance with COMAR 26.10.09, an owner and an operator of a storage tank system and a responsible party shall use the steps described in §§B and C of this regulation, or other procedures required by the Department to:</text>
        <paragraph num="(1)">
          <text>Immediately but not later than 48 hours from the time a suspected spill, release, or discharge is discovered under Regulation .01 of this chapter or from the time an owner and an operator of a storage tank system and a responsible party is directed by the Department under Regulation .02 of this chapter, investigate a suspected spill, release, or discharge of a regulated substance; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Within 7 days of beginning the investigation, or another time period specified by the Department, confirm:</text>
          <paragraph num="(a)">
            <text>All suspected spills, releases, and discharges of regulated substances requiring reporting under Regulation .01 of this chapter; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The source of off-site impacts if directed by the Department, as required under Regulation .02 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>System Test.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a storage tank system and a responsible party shall conduct a system test to determine whether a leak exists in the storage tank, the piping, the secondary containment, or another component of the storage tank system by conducting:</text>
          <paragraph num="(a)">
            <text>Precision tightness testing in accordance with COMAR 26.10.03.05;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>As appropriate, secondary containment testing in accordance with COMAR 26.10.04.04D; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A testing procedure required by the Department.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>When a storage tank system fails a system test required by §B(1) of this regulation or another test for tightness, an owner and an operator of a storage tank system and a responsible party shall take the following steps:</text>
          <paragraph num="(a)">
            <text>Immediately discontinue use of the storage tank system and notify the Department;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Within 48 hours, begin an investigation to determine whether the leak is occurring in the storage tank, the piping, the secondary containment, or another component of the storage tank system;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>If the storage tank is determined to be leaking, immediately remove the regulated substance from the storage tank;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>If the piping system is determined to be leaking, immediately drain and discontinue the use of the piping system;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>If the system test confirms a release into the interstice or a spill, release, or discharge to the environment:</text>
            <paragraph num="(i)">
              <text>Repair the storage tank system in accordance with COMAR 26.10.04.04;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Replace or upgrade the storage tank system in accordance with COMAR 26.10.03; or</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Close the storage tank system in accordance with COMAR 26.10.10;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(f)">
            <text>If another component of the storage tank system is determined to be leaking, perform the necessary repairs to the storage tank system in accordance with COMAR 26.10.04.04 within a time period approved by the Department; and</text>
          </paragraph>
          <paragraph num="(g)">
            <text>After repairing or replacing the storage tank system and before placing the storage tank system back in service, conduct a system test on the storage tank system in accordance with §B(1) of this regulation to verify that the condition that caused the original test failure has been corrected.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>In addition to complying with the steps in §B(2) of this regulation, an owner and an operator of a storage tank system and a responsible party shall begin corrective action in accordance with COMAR 26.10.09 if the system test results for the storage tank system, storage tank, or piping indicate the existence of a spill, release, or discharge to the environment.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner and an operator of a storage tank system and a responsible party are not required to conduct further investigation if the system test results for the storage tank system, storage tank, and piping do not indicate the existence of a spill, release, or discharge and environmental contamination was not the basis for suspecting a spill, release, or discharge.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>An owner and an operator of a storage tank system and a responsible party shall conduct a site check as described in §C of this regulation if the system test results for the storage tank system, storage tank, and piping do not indicate the existence of a spill, release, or discharge, but environmental contamination was the basis for suspecting a spill, release, or discharge.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Site Check.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a storage tank system and a responsible party shall measure for the presence of a spill, release, or discharge where contamination is most likely to be present.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In selecting sample types, sample locations, and measurement methods, an owner and an operator of a storage tank system and a responsible party shall consider:</text>
          <paragraph num="(a)">
            <text>The nature of the stored substance;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The type of initial alarm or cause for suspicion;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The type of backfill;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The depth to groundwater; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Other factors appropriate for identifying the presence and source of a spill, release, or discharge.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>If the test results for the excavation zone or the site indicate that a spill, release, or discharge has occurred, an owner and an operator of a storage tank system and a responsible party shall begin corrective action in accordance with COMAR 26.10.09.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>If the test results for the excavation zone or the site do not indicate that a spill, release, or discharge has occurred, the Department will determine if further investigation is required.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>If required by the Department, an owner and an operator of a storage tank system and a responsible party shall construct observation, monitoring, and recovery wells:</text>
          <paragraph num="(a)">
            <text>In compliance with COMAR 26.04.04;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Of polyvinylchloride or another material approved by the Department;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>With a proper grout seal and locking cap; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>As required in an approved corrective action plan developed in accordance with COMAR 26.10.09.07.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Reporting and Remediating Spills, Releases, Discharges, and Overfills.">
      <text>Upon detecting or confirming a spill, release, or discharge or an overfill of a regulated substance, an owner and an operator of a storage tank system and a responsible party shall:</text>
      <paragraph num="A.">
        <text>Not later than 2 hours after detecting or confirming the spill, release, discharge or the overfill, or within another reasonable time period specified by the Department:</text>
        <paragraph num="(1)">
          <text>Contain and immediately remediate the spill, release, or discharge or the overfill of a regulated substance and begin corrective action in accordance with COMAR 26.10.09; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Report the spill, release, or discharge or the overfill as follows:</text>
          <paragraph num="(a)">
            <text>Report a spill, release, or discharge or an overfill of oil to the Department in accordance with COMAR 26.10.01.05; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Report a spill or release, or an overfill that results in a spill or release, of a hazardous substance equal to or greater than its reportable quantity under 40 CFR Part 302 to the Department and the National Response Center in accordance with 40 CFR §§302.6 and 355.40;</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Determine the cause of the spill, release, or discharge or the overfill of a regulated substance from a storage tank system; and</text>
      </paragraph>
      <paragraph num="C.">
        <text>If the spill or overfill prevention equipment of the storage tank system is determined to be the cause of the spill, release, or discharge or overfill of a regulated substance, repair or replace the spill or overfill prevention equipment in accordance with COMAR 26.10.03.03 and 26.10.04.04 prior to receiving a regulated substance delivery.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407, 4-408, 4-410—4-411.1, 4-417, and 7-201 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective November 4, 1996 (23:22 Md. R. 1498)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03C amended effective February 18, 2002 (29:3 Md. R. 224); January 16, 2006 (33:1 Md. R. 40)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.04 repealed and new Regulations .01—.04 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="09" heading="Spill, Release, and Discharge Response and Corrective Action">
    <regulation prefix="Regulation" num=".01" heading="General.">
      <paragraph num="A.">
        <text>In response to a confirmed spill, release, or discharge of a regulated substance from a storage tank system, the following persons shall comply with the requirements of this chapter:</text>
        <paragraph num="(1)">
          <text>If a confirmed spill, release, or discharge of a regulated substance from a UST system, the owner and the operator of the UST system and any responsible party; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Except as otherwise directed by the Department, if a confirmed spill, release, or discharge of oil from a storage tank system, the owner and the operator of the storage tank system and any responsible party.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a storage tank system and a responsible party shall continue any required abatement, investigation, removal, remediation, mitigation, monitoring, corrective action, or product recovery activities required under this chapter in response to a spill, release, or discharge of a regulated substance until the required activities are completed to the satisfaction of the Department.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Definitions.</text>
        <paragraph num="(1)">
          <text>In this section, “discharge” means:</text>
          <paragraph num="(a)">
            <text>The addition, introduction, leaking, spilling, or emitting of any pollutant to waters of this State; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The placing of a pollutant in a location where the pollutant is likely to pollute.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>In this chapter, “discharge permit” has the following meaning:</text>
          <paragraph num="(a)">
            <text>“Discharge permit” means a permit issued by the Department for the discharge of any pollutant or combination of pollutants into the waters of the State; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Discharge permit” includes:</text>
            <paragraph num="(i)">
              <text>A State discharge permit issued under Environment Article, §9-323, Annotated Code of Maryland; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A National Pollutant Discharge Elimination System permit issued under the Federal Water Pollution Control Act (33 U.S.C. §§1251 et seq.), its amendments, and all regulations and rules adopted under the Act.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>In this chapter, “permitted discharge” means a discharge conducted under a discharge permit and in compliance with the water pollution control requirements and conditions of COMAR 26.08.01—26.08.04.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Initial Response.">
      <text>Within 2 hours, or another reasonable time period specified by the Department, of confirming a spill, release, or discharge of a regulated substance in accordance with COMAR 26.10.08.03 or after a spill, release, or discharge of a regulated substance from a storage tank system is identified in any other manner, an owner and an operator of a storage tank system and a responsible party shall perform the following initial response actions:</text>
      <paragraph num="A.">
        <text>Report the spill, release, or discharge of the regulated substance to the Department in accordance with COMAR 26.10.08.04;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Take immediate action to prevent any further spilling, releasing, or discharging of the regulated substance into the environment or secondary containment;</text>
      </paragraph>
      <paragraph num="C.">
        <text>Identify and mitigate fire, explosion, and vapor hazards; and</text>
      </paragraph>
      <paragraph num="D.">
        <text>Perform any other initial response actions required by the Department.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Initial Abatement Measures and Site Check.">
      <paragraph num="A.">
        <text>Unless directed to do otherwise by the Department, an owner and an operator of a storage tank system and a responsible party shall perform each of the following abatement measures:</text>
        <paragraph num="(1)">
          <text>Remove as much of the regulated substance from the storage tank system as is necessary to prevent further spilling, releasing, or discharging of the regulated substance to the environment;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Visually inspect any aboveground spills, releases, or discharges or exposed belowground spills, releases, or discharges and prevent further migration of the spilled, released, or discharged regulated substance into surrounding soils, surface water, and groundwater;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Continue to monitor and mitigate any fire and safety hazards posed by vapors or free product that have migrated from a UST excavation zone or a storage tank system site and entered into subsurface structures, such as sewers or basements;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Remedy hazards posed by contaminated soils that are excavated or exposed as a result of a spill, release, or discharge confirmation, site investigation, abatement, or corrective action activity by:</text>
          <paragraph num="(a)">
            <text>Removing contaminated soils from the site within 50 days of excavation for treatment or disposal in compliance with applicable federal, State, and local laws; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Treating contaminated soils in accordance with a corrective action plan approved by the Department;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Unless the location, extent, and source of a spill, release, or discharge were confirmed during a site check conducted in accordance with COMAR 26.10.08.03C or a closure site assessment conducted in accordance with COMAR 26.10.10.03A, perform a site check to determine the location and extent of a spill, release, or discharge by:</text>
          <paragraph num="(a)">
            <text>Measuring for the presence of the spill, release, or discharge in the area where contamination is most likely to be present; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Selecting sample types, sample locations, and measurement methods for identifying the presence and source of the spill, release, or discharge that consider the:</text>
            <paragraph num="(i)">
              <text>Nature of the stored substance;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Site soil characteristics;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Type of backfill;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Depth to groundwater; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Other relevant factors for identifying the presence and source of the spill, release, or discharge; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>Investigate to determine the possible presence of free product and begin free product removal as soon as practicable in accordance with Regulation .05 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Within 20 days of confirming a spill, release, or discharge, or within another reasonable time period required by the Department, an owner and an operator of a storage tank system and a responsible party shall submit a report to the Department summarizing the initial abatement steps taken in compliance with §A of this regulation and any resulting information or data.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Initial Site Characterization.">
      <paragraph num="A.">
        <text>Unless directed to do otherwise by the Department, an owner and an operator of a storage tank system and a responsible party shall assemble information about the site and the nature of the spill, release, or discharge that includes:</text>
        <paragraph num="(1)">
          <text>Information gained while confirming the spill, release, or discharge and completing the initial abatement measures required in Regulations .02 and .03 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Data on the nature and estimated quantity of a spill, release, or discharge;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Data from available sources or site investigations, or both, concerning the following:</text>
          <paragraph num="(a)">
            <text>Surrounding populations;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Water quality;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A map showing the use and approximate locations of wells potentially affected by the spill, release, or discharge;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Subsurface soil conditions;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Locations of subsurface utilities;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Climatological conditions; and</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Land use at the site and surrounding area;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>The results of the site check performed in compliance with Regulation .03A(5) of this chapter;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>To determine whether free product must be recovered in accordance with Regulation .05 of this chapter, the results of the free product investigation performed in accordance with Regulation .03A(6) of this chapter; and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Any other information required by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a storage tank system and a responsible party shall:</text>
        <paragraph num="(1)">
          <text>Prepare a written site characterization report that:</text>
          <paragraph num="(a)">
            <text>Includes all of the information required under §A of this regulation regarding the site and the nature of the spill, release, or discharge; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Discusses the applicability, reliability, and validity of the information provided; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Submit the site characterization report required under §B(1) of this regulation to the Department within:</text>
          <paragraph num="(a)">
            <text>45 days of confirming the spill, release, or discharge; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Another reasonable time period required by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Free Product Removal.">
      <paragraph num="A.">
        <text>At sites where free product is present or an investigation performed in compliance with Regulation .03A(6) of this chapter indicates the presence of free product, an owner and an operator of a storage tank system and a responsible party shall remove free product to the maximum extent practicable as determined by the Department while:</text>
        <paragraph num="(1)">
          <text>Continuing, as necessary, to perform any initial corrective action measures initiated under Regulations .02—.04 of this chapter; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Preparing to perform the corrective action measures required under Regulations .06 and .07 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>In meeting the requirements of this regulation, an owner and an operator of a storage tank system and a responsible party shall:</text>
        <paragraph num="(1)">
          <text>Before beginning free product removal:</text>
          <paragraph num="(a)">
            <text>Provide notification to the Department regarding the proposed free product recovery method to be used; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In accordance with the permitting requirements in COMAR 26.08.04, obtain the necessary discharge permit for the proposed free product recovery method;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Conduct free product removal in a manner that:</text>
          <paragraph num="(a)">
            <text>Prevents the spread of contamination from entering previously uncontaminated areas by using recovery and disposal techniques appropriate to the hydrogeologic conditions at the site; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Properly treats, disposes, or conducts permitted discharges of recovery byproducts in compliance with applicable federal, State, and local laws;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Use abatement of free product migration as a minimum initial objective for the design of the free product removal system;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Handle any flammable products in a safe and competent manner to prevent fires or explosions; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Unless directed to do otherwise by the Department, within 45 days after confirming a spill, release, or discharge, prepare and submit to the Department a free product removal report that provides at least the following information:</text>
          <paragraph num="(a)">
            <text>The name, address, and phone number of the person or persons responsible for implementing the free product removal measures;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The estimated quantity, type, and thickness of free product observed or measured in wells, boreholes, and excavations;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The type of free product recovery system to be used;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>A description of any permitted discharge to take place on-site or off-site during the free product recovery operation including:</text>
            <paragraph num="(i)">
              <text>The location of each permitted discharge outfall;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The type of treatment applied to the permitted discharge;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The effluent quality achieved from the treatment applied to the permitted discharge; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>An assessment of compliance with the discharge permit required under §B(1)(b) of this regulation; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(e)">
            <text>The disposition of the recovered free product.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Investigations of Soil and Groundwater.">
      <paragraph num="A.">
        <text>In order to determine the full extent and location of soils contaminated by a spill, release, or discharge and the presence and concentrations of dissolved product contamination in the groundwater, an owner and an operator of a storage tank system and a responsible party shall conduct investigations of the spill, release, or discharge, the site, and the surrounding area potentially affected by the spill, release, or discharge if one or more of the following conditions exist:</text>
        <paragraph num="(1)">
          <text>There is evidence that groundwater wells have been affected by the spill, release, or discharge;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Free product is present;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>There is evidence that contaminated soils may contaminate groundwater; or</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The Department requests an investigation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a storage tank system and a responsible party shall submit the information collected in compliance with §A of this regulation as soon as practicable, but not later than 90 days after confirming a spill, release, or discharge or in accordance with a schedule established by the Department.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Corrective Action Plan.">
      <paragraph num="A.">
        <text>At any point after reviewing the information submitted in compliance with Regulations .02—.04 of this chapter, the Department may require an owner and an operator of a storage tank system and a responsible party to:</text>
        <paragraph num="(1)">
          <text>Submit additional information related to the requirements of this chapter; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Develop and submit a corrective action plan for remediating contaminated soil and groundwater, and submit the corrective action plan according to a schedule and in a format established by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>After fulfilling the requirements of Regulations .02—.04 of this chapter, an owner and an operator of a storage tank system and a responsible party may choose to submit a corrective action plan for remediating contaminated soil and groundwater.</text>
      </paragraph>
      <paragraph num="C.">
        <text>If a corrective action plan is submitted under a scenario described in §A or B of this regulation, an owner and an operator of a storage tank system and a responsible party shall:</text>
        <paragraph num="(1)">
          <text>Ensure the corrective action plan provides for the adequate protection of human health and the environment as determined by the Department; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Modify a submitted corrective action plan as necessary to maintain adequate protection of human health and the environment as determined by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>The Department may approve a corrective action plan submitted by an owner and an operator of a storage tank system and a responsible party only after:</text>
        <paragraph num="(1)">
          <text>Ensuring that the implementation of the plan will adequately protect human health, safety, and the environment; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Considering the following factors, as appropriate:</text>
          <paragraph num="(a)">
            <text>The physical and chemical characteristics of the regulated substance, including its toxicity, persistence, and potential for migration;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The hydrogeologic characteristics of the site and the surrounding area;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The proximity, quality, and current and future uses of nearby surface water and groundwater;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The potential effects of residual contamination at the conclusion of the planned corrective action on nearby surface water and groundwater;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>An exposure assessment; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Any information assembled in compliance with this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Upon approval of a corrective action plan or as directed by the Department, an owner and an operator of a storage tank system and a responsible party shall:</text>
        <paragraph num="(1)">
          <text>Implement the plan, including modifications to the plan made by the Department; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Monitor, evaluate, and report the results of implementing the plan in accordance with a schedule and in a format established by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>In the interest of minimizing environmental contamination and promoting more effective remediation, an owner and an operator of a storage tank system and a responsible party may begin remediation of soil and groundwater before the corrective action plan is approved, if the owner and the operator of the storage tank system and the responsible party:</text>
        <paragraph num="(1)">
          <text>Notifies the Department of its intention to begin remediation;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Complies with any conditions imposed by the Department, including halting remediation or mitigating adverse consequences from remediation activities; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Incorporates these self-initiated remediation measures into the corrective action plan that is submitted to the Department for approval.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>In accordance with Regulation .01B of this chapter, an owner and an operator of a storage tank system and a responsible party shall continue remediation activities until removal of the spilled, released, or discharged regulated substance is accomplished to the satisfaction of the Department.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Public Participation.">
      <paragraph num="A.">
        <text>Notice to Affected Public. For each confirmed spill, release, or discharge that requires a corrective action plan, the Department, in cooperation with an owner and an operator of a storage tank system and a responsible party, shall provide notice:</text>
        <paragraph num="(1)">
          <text>To those members of the public directly affected by the spill, release, or discharge and the planned corrective action, as determined by the Department; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In a manner designed to reach the affected public that may include, but is not limited to:</text>
          <paragraph num="(a)">
            <text>Publication in local newspapers;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Block advertisements;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Public service announcements;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Publication in the Maryland Register;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Letters to individual property owners; or</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Personal contact by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Before approving a corrective action plan, the Department may hold a public meeting to consider comments on the proposed corrective action plan or for any other reason.</text>
      </paragraph>
      <paragraph num="C.">
        <text>If the Department considers terminating the remedial work under a corrective action plan before achievement of any goals set forth in the plan, the Department shall notify the affected public in the manner set forth in §A of this regulation.</text>
      </paragraph>
      <paragraph num="D.">
        <text>As required by the Public Information Act, the Department shall ensure that information regarding the site of a spill, release, or discharge and decisions concerning a corrective action plan are made available to the public for inspection upon request.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407, 4-408, 4-410, 4-411, 4-417, and 7-201 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.07 amended and Regulation .08 adopted effective November 4, 1996 (23:22 Md. R. 1498)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04A amended effective June 29, 1998 (25:13 Md. R. 997)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05 amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.08 repealed and new Regulations .01—.08 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="10" heading="Out-of-Service UST Systems and Closure">
    <regulation prefix="Regulation" num=".01" heading="Temporary Closure.">
      <paragraph num="A.">
        <text>When a UST system is temporarily closed, an owner and an operator of a UST system shall:</text>
        <paragraph num="(1)">
          <text>If a metal UST system, continue operation and maintenance of corrosion protection in accordance with COMAR 26.10.04.02;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Except as provided in §B(3) of this regulation, maintain a method of release detection in accordance with COMAR 26.10.05 and, if the UST system has a field-constructed tank or is an airport hydrant system, COMAR 26.10.12;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If a spill, release, or discharge is suspected or confirmed, comply with the reporting, investigation, and corrective action requirements in COMAR 26.10.08 and 26.10.09;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>In accordance with COMAR 26.10.03.09, amend the registration for the UST system not later than 30 days following the temporary closure of the UST system; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>If a motor fuel, bulk oil storage, used oil, or hazardous substance UST system, perform the UST system inspections required in COMAR 26.10.03.10.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>When a UST system is temporarily closed and the storage tank system is emptied by having all materials removed using commonly employed practices so that not more than 1 inch of residue or 0.3 percent by weight of the total capacity of the UST remain in the UST system, an owner and an operator of a UST system is not required to perform:</text>
        <paragraph num="(1)">
          <text>Operation and maintenance testing and inspections of spill and overfill prevention equipment, as required by COMAR 26.10.03.03;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Periodic operation and maintenance walkthrough inspections, as required by COMAR 26.10.04.03; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Operation and maintenance testing and inspections of release detection equipment, as required by COMAR 26.10.05.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>When a UST system is temporarily closed for 3 months or more, an owner and an operator of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Leave the vent line open and functioning; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Cap and secure all other lines, pumps, manways, and ancillary equipment.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>When a UST system does not meet the performance standards for new UST systems in COMAR 26.10.03.01 or the upgrading requirements in COMAR 26.10.03.08, except for the requirements of COMAR 26.10.03.08F, and the UST system has been temporarily closed for more than 6 months, an owner and an operator of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Permanently close the UST system in accordance with Regulations .02—.05 of this chapter; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If the Department grants an extension, permanently close the UST system within the time period established by the Department and in accordance with Regulations .02—.05 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>When a UST system meets the performance standards for new UST systems in COMAR 26.10.03.01 or the upgrading requirements in COMAR 26.10.03.08, and the UST system has been temporarily closed for more than 1 year, an owner and an operator of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Permanently close the UST system in accordance with Regulations .02—.05 of this chapter; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If the Department grants an extension, permanently close the UST system within the time period established by the Department and in accordance with Regulations .02—.05 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>An owner and an operator of a temporarily closed UST system required to permanently close the UST system under §D or E of this regulation may apply to the Department for an extension to the required time period for completing the permanent closure by:</text>
        <paragraph num="(1)">
          <text>Completing a site assessment in accordance with the procedures in Regulation .03 of this chapter; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Submitting a written site assessment report to the Department that includes, at a minimum, the following information:</text>
          <paragraph num="(a)">
            <text>The location of the UST system on the property;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The date the site assessment was performed;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A summary of any field test and the laboratory analytical results;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The name of the contractors who performed the work; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>All analytical data and laboratory reports.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Permanent Closure and Changes-in-Service.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system, an underground farm tank, an underground residential tank, and an underground residential heating oil tank shall have a permanent closure or change-in-service of a storage tank system performed by or under the supervision of a certified UST system technician or remover.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of a UST system shall conduct a permanent closure or change-in-service of a storage tank system in accordance with the following documents:</text>
        <paragraph num="(1)">
          <text>API Recommended Practice 1604 “Closure of Underground Petroleum Storage Tanks”; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>PEI/RP 1700 “Recommended Practices for the Closure of Underground Storage Tank and Shop-Fabricated Aboveground Storage Tank Systems”.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Notification.</text>
        <paragraph num="(1)">
          <text>Unless a permanent closure or change-in-service of a UST system is performed in response to a corrective action, an owner, an operator, and a person in charge of a UST system shall notify the Department of a planned permanent closure or change-in-service of the UST system by submitting a notification:</text>
          <paragraph num="(a)">
            <text>In writing on a form provided by the Department; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>At least 30 days before beginning the permanent closure or change-in-service, or within another reasonable time period determined by the Department.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a UST system shall confirm a planned permanent closure of a UST system with the Department 48 hours in advance of beginning the permanent closure.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner and an operator of a UST system shall perform an assessment of the excavation zone, as required under Regulation .03 of this chapter:</text>
          <paragraph num="(a)">
            <text>After notifying the Department of a planned permanent closure or change-in-service of the UST system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Before completion of the permanent closure or change-in-service of the UST system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>In accordance with COMAR 26.10.03.09, an owner, an operator, and a person in charge of a UST system that was permanently closed or underwent a change-in-service shall amend the registration for the UST system after the permanent closure or change-in-service of the UST system is complete.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Permanent Closure.</text>
        <paragraph num="(1)">
          <text>When a UST system is permanently taken out-of-service, an owner and an operator of a UST system shall permanently close the UST system by:</text>
          <paragraph num="(a)">
            <text>Removing the UST system from the ground; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If approved by the Department, abandoning the UST system in place.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Unless otherwise directed by the Department, an owner, an operator, and a person in charge of a UST system requesting to abandon the UST system in place shall provide the Department with a report signed by a professional engineer that confirms the permanent closure of the UST system by removal would have an adverse effect on a building foundation or other important structures or utilities within the immediate vicinity of the excavation zone.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>To permanently close a UST system by removal or abandonment in place, an owner, an operator, and a person in charge of a UST system shall take the following actions:</text>
          <paragraph num="(a)">
            <text>Immediately before closing the UST system, empty and clean the UST and piping by removing all flammable, combustible, and other liquids and accumulated sludge from the UST system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Unless otherwise directed by the Department, disconnect and remove all emptied lines;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Remove all aboveground portions of vent lines and cap the remaining lines at their bases; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Remove all regulated substances, sludge, and soil contaminated with a regulated substance found during the UST system closure for treatment or disposal in compliance with applicable federal, State, and local laws.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>If a UST system is permanently closed by removal, an owner, an operator, and a person in charge of a UST system shall take the following actions:</text>
          <paragraph num="(a)">
            <text>Purge all explosive vapors from the UST prior to removal from the excavation zone;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Monitor the UST with an appropriate meter for vapors before and during removal of the UST from the excavation zone;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Once the UST system has been removed from the excavation zone:</text>
            <paragraph num="(i)">
              <text>Retest the UST for flammable vapors and, if necessary, purge all remaining explosive vapors; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Make holes or openings in the UST to render it unfit for further use;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>If the operation poses a threat to public safety, do not crush or cut up the UST on-site;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Dispose of the UST system materials at a location acceptable to the Department; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Fill the former UST system excavation zone to grade with an appropriate fill material.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>If a UST system is permanently closed by abandonment in place, an owner, an operator, and a person in charge of a UST system shall take the following actions:</text>
          <paragraph num="(a)">
            <text>Do not fill the UST through a fill or vent pipe;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Provide proper openings by excavation, or other means, on the UST to facilitate cleaning and filling the UST;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Completely fill the UST with a solid, inert, and flowable material so there are no voids in the UST;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Dispose of any removed UST system materials at a location acceptable to the Department; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Fill any excavated areas to grade with an appropriate fill material.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Change-in-Service. When an owner and an operator of a UST system chooses to store a nonregulated substance in a UST system, the owner and the operator of the UST system shall:</text>
        <paragraph num="(1)">
          <text>Notify the Department of the planned change-in-service of the UST system in accordance with §C(1) of this regulation;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Before completing the change-in-service, perform a site assessment in accordance with Regulation .03 of this chapter; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>To conduct the change-in-service, empty and clean the UST and piping by removing all flammable, combustible, and other liquids and accumulated sludge from the UST system.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Assessing the Site at Closure or Change-in-Service.">
      <paragraph num="A.">
        <text>Before applying for an extension for temporary closure or completing a permanent closure or change-in-service of a UST system, an owner and an operator of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Perform a site assessment to determine if there is evidence of a spill, release, or discharge where contamination would most likely be present; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In selecting sample types, sample locations, and measurement methods consider:</text>
          <paragraph num="(a)">
            <text>The method of closure;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The nature of the stored regulated substance;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The type of backfill;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The depth to groundwater; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Other factors appropriate for identifying the presence of a spill, release, or discharge.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>If contaminated soil, contaminated groundwater, free product, or vapor is discovered while performing the actions under §A of this regulation or by any other manner during a UST system closure or change-in-service activities, an owner, an operator, and a person in charge of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Notify the Department within 2 hours of the discovery, as required in COMAR 26.10.08; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Begin performing the response and corrective actions required in COMAR 26.10.09.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Applicability to Previously Closed UST Systems.">
      <text>When directed by the Department, an owner and an operator of a UST system that was permanently closed before December 22, 1988 shall assess the excavation zone and close the UST system in accordance with this chapter if a spill, release, or discharge from the UST system may, in the judgment of the Department, pose a current or potential threat to human health and the environment.</text>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Closure Records.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system shall maintain records in accordance with COMAR 26.10.04.05 that demonstrate compliance with closure requirements under this chapter.</text>
      </paragraph>
      <paragraph num="B.">
        <text>The owner and the operator of a UST system that took the UST system out-of-service or the current owner and operator of a property where the UST system was taken out-of-service shall:</text>
        <paragraph num="(1)">
          <text>Maintain the closure report required in §C of this regulation and the results of the site assessment required in Regulation .03 of this chapter for at least 5 years after completion of a permanent closure or change-in-service; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Maintain the records specified in §B(1) of this regulation by:</text>
          <paragraph num="(a)">
            <text>Storing the records at the property; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If the records cannot be stored at the property, submitting the records to the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>UST System Closure Report. An owner and an operator of a UST system that underwent a permanent closure or change-in-service shall submit to the Department a written UST system closure report:</text>
        <paragraph num="(1)">
          <text>Signed by the certified UST system technician or remover that performed the permanent closure or change-in-service;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Within 45 days of completing the UST system closure or change-in-service; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>That includes records documenting:</text>
          <paragraph num="(a)">
            <text>The permanent closure or change-in-service of the UST system was conducted in accordance with Regulation .02 of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The site assessment was performed in accordance with Regulation .03 of this chapter; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>At a minimum, all of the following information:</text>
            <paragraph num="(i)">
              <text>The UST size;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The location of the UST system on the property;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The date of the UST system closure or change-in-service;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The method used for the UST system closure or change-in-service;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>A summary of the work performed;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>A summary of any field test and the laboratory analytical results;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>The name and certification number of the certified UST system technician or remover, and name of the contractors who performed the work;</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>If permanently closed by removal, a receipt documenting proper disposal of the UST system;</text>
            </paragraph>
            <paragraph num="(ix)">
              <text>A receipt documenting proper treatment or disposal of excavated oil-contaminated soils;</text>
            </paragraph>
            <paragraph num="(x)">
              <text>All analytical data and laboratory reports; and</text>
            </paragraph>
            <paragraph num="(xi)">
              <text>Photographs of each UST system taken out-of-service and each excavation zone.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>An owner and an operator of an underground farm tank, an underground residential tank, and an underground residential heating oil tank that does not meet the definition of a UST shall submit a written storage tank closure report in accordance with the requirements in §C of this regulation if:</text>
        <paragraph num="(1)">
          <text>A spill, release, or discharge occurred at the property that required the owner and the operator of the underground storage tank to notify the Department in compliance with COMAR 26.10.08 and 26.10.09; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The Department directs the owner and the operator of the underground storage tank to submit a storage tank closure report.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-402, 4-405, 4-407, 4-408, 4-410, 4-411, 4-411.1, 4-417, and 7-201 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective November 4, 1996 (23:22 Md. R. 1498)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01D amended effective June 29, 1998 (25:13 Md. R. 997)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02F amended effective June 29, 1998 (25:13 Md. R. 997)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.05 repealed and new Regulations .01—.05 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="11" heading="UST Financial Responsibility">
    <regulation prefix="Regulation" num=".01" heading="General.">
      <paragraph num="A.">
        <text>Owners of UST systems described in 40 CFR §280.90, including local governments that own UST systems, shall demonstrate financial responsibility for one or more USTs in accordance with the requirements of this chapter and 40 CFR §§280.90—280.116.</text>
      </paragraph>
      <paragraph num="B.">
        <text>The requirements for the “owner or operator” or “owners or operators” of a UST system contained in 40 CFR §§280.90—280.116 are to be assumed solely by the “owner” of a UST system.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Incorporation by Reference.">
      <paragraph num="A.">
        <text>As qualified by §§B and C of this regulation, 40 CFR §§280.90—280.116 (October 13, 2015) is incorporated by reference.</text>
      </paragraph>
      <paragraph num="B.">
        <text>For the purposes of this chapter, a person shall make the following substitutions:</text>
        <paragraph num="(1)">
          <text>Wherever the words “Director”, “Director of the Implementing Agency”, “EPA Regional Administrator”, or “Director of the EPA” appear, substitute “Secretary of the Environment”; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Wherever the words “a state implementing agency” or “implementing agency” appear, substitute “the Maryland Department of the Environment”, “the Department”, or “MDE”.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>For the purposes of this chapter, a person shall interpret the following cross-references contained in 40 CFR §§280.90—280.116 as follows:</text>
        <paragraph num="(1)">
          <text>Interpret a cross-reference to 40 CFR Part 280, Subpart E as COMAR 26.10.08;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Interpret a cross-reference to 40 CFR Part 280, Subpart F as COMAR 26.10.09; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Interpret a cross-reference to 40 CFR Part 280, Subpart G as COMAR 26.10.10.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Additional Mechanism for Local Governments to Demonstrate Financial Responsibility.">
      <paragraph num="A.">
        <text>In addition to the mechanisms for demonstrating financial responsibility listed in 40 CFR §§280.95—280.107, a local government may use the mechanism described in §§B—D of this regulation to demonstrate financial responsibility for one or more USTs.</text>
      </paragraph>
      <paragraph num="B.">
        <text>A local government may obtain environmental liability coverage from an insurance pool that:</text>
        <paragraph num="(1)">
          <text>Is established under Insurance Article, §§19-602 and 19-603, Annotated Code of Maryland;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The Secretary of the Environment has determined to be financially sound and at least as equivalent to one or more of the financial assurance mechanisms provided in 40 CFR §§280.95—280.107; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>On an annual basis, provides any information to the Department considered necessary to assess whether the insurance pool remains financially sound.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>When determining the financial soundness of an insurance pool, the Secretary of the Environment may consider the certainty of the availability of the insurance pool funds to cover the potential liability of participating local governments to take corrective action or to compensate third parties for bodily injury and property damage, or both, caused by an accidental spill, release, or discharge arising from the operation of petroleum USTs, as set forth in 40 CFR §280.93.</text>
      </paragraph>
      <paragraph num="D.">
        <text>A local government using an insurance pool approved under this chapter to demonstrate financial responsibility for one or more USTs shall:</text>
        <paragraph num="(1)">
          <text>Obtain a separate endorsement, certificate, or similar document worded in accordance with the forms set forth in 40 CFR §280.97(b); and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Comply with all applicable provisions of 40 CFR §§280.90—280.116, including those imposing requirements for reporting and recordkeeping.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Reporting Requirements.">
      <paragraph num="A.">
        <text>An owner of a UST system shall provide evidence of financial responsibility for one or more USTs to the Department as follows:</text>
        <paragraph num="(1)">
          <text>Submit evidence of financial responsibility in an electronic format determined by the Department according to the following schedule:</text>
          <paragraph num="(a)">
            <text>Annually, but not later than 90 days following the initiation of coverage under a financial mechanism or the anniversary date of existing coverage under a financial mechanism; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Upon the request of the Department; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Submit as evidence of financial responsibility any applicable forms listed in 40 CFR §280.111(b) or any other information relevant to compliance with the provisions of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Unless otherwise directed by the Department, an owner of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Comply with all of the applicable notification provisions of 40 CFR §§280.90—280.116, including any accompanying reporting and recordkeeping requirements; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Provide notification to the Department that demonstrates that the financial assurance mechanism is valid.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>In accordance with the UST system registration requirements in COMAR 26.10.03.09, an owner of a UST system shall:</text>
        <paragraph num="(1)">
          <text>Certify compliance with the financial responsibility requirements of this chapter when registering a newly installed or acquired UST system; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Amend the registration for a registered UST system if:</text>
          <paragraph num="(a)">
            <text>The owner of the UST system is released from the requirement to maintain financial responsibility for the UST system, as provided under 40 CFR §280.113; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The owner of the UST system obtains an alternate mechanism of financial responsibility, if required under 40 CFR §280.114.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>In addition to the requirements in §§A and B of this regulation, an owner of a UST system that uses an insurance policy or risk retention group coverage to demonstrate financial responsibility for one or more USTs shall provide to the Department on an annual basis:</text>
        <paragraph num="(1)">
          <text>An endorsement or certificate of insurance;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Any amendments to the insurance policy or risk retention group coverage, including amendments for additional insured; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A UST schedule that includes, at a minimum, the following information:</text>
          <paragraph num="(a)">
            <text>The Department issued regulated substance storage facility identification number;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The registered UST system owner’s name and address as insured;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The installation date of the UST system;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The UST system capacity in gallons;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>A statement that the UST construction is single-walled or double-walled; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>The type of regulated substance stored in the UST system.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-411.2, and 4-415.1, 4-417, 4-701 et seq., and 7-201 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 4, 1991 (18:2 Md. R. 151)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 amended effective March 14, 1994 (21:5 Md. R. 405)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01B amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02 adopted effective March 14, 1994 (21:5 Md. R. 405)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.02 repealed and new Regulations .01—.04 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="12" heading="UST Systems with Field-Constructed Tanks and Airport Hydrant Fuel Distribution Systems">
    <regulation prefix="Regulation" num=".01" heading="General Requirements.">
      <paragraph num="A.">
        <text>Implementation of Requirements. Except as otherwise provided in Regulations .02—.05 of this chapter, an owner, an operator, and a person in charge of a UST system with a field-constructed tank or an airport hydrant system shall comply with requirements of this chapter, COMAR 26.10.02—26.10.11 and 26.10.16 in accordance with the following schedule:</text>
        <paragraph num="(1)">
          <text>For a UST system installed after June 13, 2022, upon installation of the UST system; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>For a UST system installed on or before June 13, 2022:</text>
          <paragraph num="(a)">
            <text>Comply with the following requirements not later than October 13, 2022:</text>
            <paragraph num="(i)">
              <text>Upgrade requirements in Regulation .03 of this chapter;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Spill and overfill control requirements in COMAR 26.10.04.01;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Operation and maintenance of corrosion protection requirements in COMAR 26.10.04.02;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Compatibility requirements in COMAR 26.10.03.07;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Requirements regarding repairs allowed on UST systems in COMAR 26.10.04.04;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Reporting and recordkeeping requirements in Regulation .07 of this chapter and COMAR 26.10.04.05;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>Spill and overfill prevention equipment and testing requirements in COMAR 26.10.03.03;</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>Periodic operation and maintenance walkthrough inspections requirements in Regulation .04 of this chapter and COMAR 26.10.04.03;</text>
            </paragraph>
            <paragraph num="(ix)">
              <text>Release detection requirements in Regulation .05 of this chapter and COMAR 26.10.05; and</text>
            </paragraph>
            <paragraph num="(x)">
              <text>Operator training requirements in COMAR 26.10.16; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Comply with the following requirements on and after June 13, 2022:</text>
            <paragraph num="(i)">
              <text>Requirements for reporting, investigating, and confirming a spill, release, or discharge in COMAR 26.10.08;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Spill, release, and discharge response and corrective action requirements in COMAR 26.10.09;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Closure and change-in-service of a UST system requirements in COMAR 26.10.10;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Except as provided in §B of this regulation, UST system registration requirements in COMAR 26.10.03.09; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Except as provided in §C of this regulation, financial responsibility requirements in COMAR 26.10.11.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Not later than October 13, 2022, an owner, an operator, and a person in charge of a UST system with a field-constructed tank or an airport hydrant system installed before June 13, 2022 shall register the UST system and maintain up-to-date registration of the UST system with the Department in accordance with COMAR 26.10.03.09.</text>
      </paragraph>
      <paragraph num="C.">
        <text>An owner of a UST system with a field-constructed tank or an airport hydrant system in use as of June 13, 2022 shall demonstrate financial responsibility for the UST system at the time of submitting a registration form for the UST system, as required in §B of this regulation.</text>
      </paragraph>
      <paragraph num="D.">
        <text>In compliance with COMAR 26.10.02.03D, an owner, an operator, and a person in charge of a UST system with a field-constructed tank or an airport hydrant system shall ensure:</text>
        <paragraph num="(1)">
          <text>The installation, upgrade, and repair of the UST system is performed by or under the supervision of a certified UST system technician;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The closure or change-in-service of the UST system is performed by or under the supervision of a certified UST system technician or remover; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Inspections required under COMAR 26.10.03.10 are performed by or under the supervision of a certified UST system inspector.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Exception to Piping Secondary Containment Requirements.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system with a field-constructed tank greater than 50,000 gallons or an airport hydrant system may use single-walled piping when installing or replacing piping associated with the UST system.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a UST system with a field-constructed tank less than or equal to 50,000 gallons that is not part of an airport hydrant system shall meet the piping performance standards and secondary containment requirements of COMAR 26.10.03.02 when installing or replacing piping.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Upgrade Requirements.">
      <paragraph num="A.">
        <text>Not later than October 13, 2022, an owner and an operator of a UST system with a field-constructed tank or an airport hydrant system installed on or before June 13, 2022 shall comply with the upgrade requirements of this section.</text>
        <paragraph num="(1)">
          <text>Corrosion Protection. The owner and the operator of the UST system shall ensure the UST system components in contact with the ground:</text>
          <paragraph num="(a)">
            <text>Except as provided in Regulation .02 of this chapter, meet the new and replacement UST system performance standards for USTs in COMAR 26.10.03.01 and piping in COMAR 26.10.03.02; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Are constructed of metal and cathodically protected according to a NACE code of practice incorporated by reference under COMAR 26.10.01.03 and meet the following cathodic protection conditions:</text>
            <paragraph num="(i)">
              <text>The cathodic protection meets the requirements of COMAR 26.10.03.01B(1)(b) and (3) for USTs and COMAR 26.10.03.02B(1)(b) and (2) for piping; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A UST greater than 10 years old without cathodic protection is assessed to ensure the UST is structurally sound and free of corrosion holes prior to adding cathodic protection through an internal inspection or another method determined by the Department.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Spill and Overfill Prevention Equipment. To prevent a spill, release, or discharge or an overfill associated with product transfer to a UST system, the owner and the operator of the UST system shall ensure the UST system meets the new UST system spill and overfill prevention equipment requirements specified in COMAR 26.10.03.03.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a UST system with a field-constructed tank or an airport hydrant system not in compliance with §A of this regulation shall:</text>
        <paragraph num="(1)">
          <text>Immediately place the UST system in temporary closure in accordance with COMAR 26.10.10.01; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Permanently close the UST system in accordance with COMAR 26.10.10.02—.05 not later than April 13, 2023, or another time period established by the Department.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Walkthrough Inspections.">
      <paragraph num="A.">
        <text>In addition to the operation and maintenance walkthrough inspection requirements in COMAR 26.10.04.03, an owner and an operator of an airport hydrant system shall inspect the following additional areas of the airport hydrant system:</text>
        <paragraph num="(1)">
          <text>Inspect hydrant pits by:</text>
          <paragraph num="(a)">
            <text>Visually checking for any damage;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Removing any liquid or debris; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Checking for evidence of a spill, release or discharge; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Inspect hydrant piping vaults and sumps by checking for evidence of a spill, release or discharge from hydrant piping.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of an airport hydrant system shall inspect the additional areas required in §A of this regulation:</text>
        <paragraph num="(1)">
          <text>Monthly if confined space entry according to the Occupational Safety and Health Administration is not required; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At least annually if confined space entry according to the Occupational Safety and Health Administration is required.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of an airport hydrant system shall maintain records of the additional areas inspected in accordance with COMAR 26.10.04.03.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Release Detection.">
      <paragraph num="A.">
        <text>Not later than October 13, 2022, an owner and an operator of a UST system with a field-constructed tank or an airport hydrant system shall provide a method of release detection in accordance with the requirements of this regulation.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Field-Constructed Tanks.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system with a field-constructed tank with a capacity less than or equal to 50,000 gallons shall meet the UST system release detection requirements in COMAR 26.10.05.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner and an operator of a UST system with a field-constructed tank with a capacity greater than 50,000 gallons shall comply with the following release detection requirements:</text>
          <paragraph num="(a)">
            <text>If a metered UST system, perform monthly inventory control in accordance with COMAR 26.10.05.04 or an equivalent procedure that can detect a leak less than or equal to 0.5 percent of the monthly flow-through; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Perform release detection in accordance with COMAR 26.10.05 or by using at least one of the following alternative methods of release detection:</text>
            <paragraph num="(i)">
              <text>Conduct an annual tank tightness test that can detect a 0.5 gallon per hour (gph) leak rate;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Use an automatic tank gauging system to perform monthly release detection that can detect a leak rate of less than or equal to 1.0 gph, and conduct a tank tightness test that can detect a 0.2 gph leak rate at least every 3 years;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Use an automatic tank gauging system to perform monthly release detection that can detect a leak rate of less than or equal to 2.0 gph, and conduct a tank tightness test that can detect a 0.2 gph leak rate at least every 2 years;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Perform vapor monitoring in accordance with §C(2)(b) of this regulation;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Perform monthly inventory control in accordance with COMAR 26.10.05.04 or an equivalent procedure that can detect a leak less than or equal to 0.5 percent of the monthly flow-through, and in conjunction perform either a tank tightness test that can detect a 0.5 gph leak rate at least every 2 years or groundwater monitoring as a monthly method of release detection in accordance with COMAR 26.10.05.05F; or</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Perform another method of release detection approved by the Department if the owner and an operator of the UST system can demonstrate that the method can detect a spill, release, or discharge as effectively as any of the methods allowed under §B(2)(b)(i)—(v) of this regulation.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Piping. An owner and an operator of a UST system with a field-constructed tank that has a capacity greater than 50,000 gallons or an airport hydrant system shall comply with the release detection requirements of this section if underground piping is associated with the field-constructed tank or the airport hydrant system.</text>
        <paragraph num="(1)">
          <text>If the UST system is metered, the owner and the operator of the UST system shall perform monthly inventory control in accordance with COMAR 26.10.05.04 or an equivalent procedure that can detect a leak less than or equal to 0.5 percent of the monthly flow-through.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The owner and the operator of the UST system shall perform a method of release detection provided in COMAR 26.10.05 or at least one of the alternative methods of release detection specified in paragraphs(a)—(d) of this subsection.</text>
          <paragraph num="(a)">
            <text>Line Tightness Test.</text>
            <paragraph num="(i)">
              <text>Perform a semiannual or annual line tightness test at or above the piping operating pressure in accordance with Table 1.</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If a piping segment with a volume of greater than or equal to 100,000 gallons is not capable of meeting the maximum 3.0 gph leak rate for a semiannual test, perform a line tightness test using a leak rate up to 6.0 gph in accordance with the schedule established in Table 2.</text>
            </paragraph>
            <aftertext>Agency Note: The leak detection rate for a test section volume may not exceed the maximum leak detection rate identified for the corresponding semiannual test or annual test.</aftertext>
          </paragraph>
          <paragraph num="(b)">
            <text>Vapor Monitoring. Perform vapor monitoring for a tracer compound placed in the UST system that is capable of detecting a 0.1 gph leak rate at least every 2 years according to the following criteria:</text>
            <paragraph num="(i)">
              <text>Test for the tracer compound within the soil gas of the excavation zone;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Use materials as backfill that are sufficiently porous, such as gravel, sand or crushed rock, to readily allow diffusion of tracer compound vapors released from the UST system into the excavation zone;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Place a tracer compound in the UST system that is sufficiently volatile to result in a vapor level that is detectable by the monitoring devices located in the excavation zone in the event the tracer compound vapors are released from the UST system;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Use a method to detect tracer compound vapors that is not rendered inoperative by groundwater, rainfall, or soil moisture or other known interferences so that a release could go undetected for more than 30 days;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Ensure that the level of background contamination in the excavation zone will not interfere with the method used to detect the tracer compound if released from the UST system;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Use a method to detect tracer compound vapors in the excavation zone that is designed and operated to detect any significant increase in the concentration of the tracer compound vapor above background;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>In the excavation zone, assess the site to ensure compliance with the requirements §C(2)(b)(ii)—(v) of this regulation and to establish the number and positioning of testing locations that will detect tracer compound vapors released within the excavation zone from any portion of the UST system; and</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>Clearly mark and secure the testing locations to avoid unauthorized access and tampering.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Inventory Control. Perform monthly inventory control in accordance with COMAR 26.10.05.04 or an equivalent procedure that can detect a leak less than or equal to 0.5 percent of the flow-through and perform one of the following methods of release detection:</text>
            <paragraph num="(i)">
              <text>Perform a line tightness test at least every 2 years in accordance with Table 1 of §C(2)(a)(i) of the regulation using the leak rates for the semiannual test; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Perform groundwater monitoring as a method of monthly release detection in accordance with COMAR 26.10.05.05F.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>An owner and an operator of a UST system with a field-constructed tank or an airport hydrant system may use another release detection method approved by the Department if the owner and an operator of the UST system can demonstrate that the method can detect a spill, release, or discharge as effectively as any of the methods allowed §C(2)(a)—(c) of this regulation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>When comparing alternative methods of release detection for approval, as provided in §§B(2)(b)(vi) and C(2)(d) of this regulation, the Department shall consider the size of release that the method can detect and the frequency and reliability of detection.</text>
      </paragraph>
      <paragraph num="E.">
        <text>Recordkeeping for Release Detection. An owner and an operator of a UST system with a field-constructed tank or an airport hydrant system shall maintain release detection records in accordance with COMAR 26.10.05.06.</text>
      </paragraph>
      <paragraph num="F.">
        <text>Notifications.</text>
        <paragraph num="(1)">
          <text>When a release detection method operated in accordance with this regulation indicates that a spill, release, or discharge may have occurred, an owner and an operator of a UST system with a field-constructed tank or an airport hydrant system shall notify the Department in accordance with COMAR 26.10.08.01.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If an owner, an operator, and a person in charge of a UST system with a field-constructed tank or an airport hydrant system changes the method of release detection used, the owner, the operator, and the person in charge of the UST system shall provide the Department written notification within 30 days of the change.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Applicability of Closure Requirements to Previously Closed UST Systems.">
      <text>When directed by the Department, an owner and an operator of a UST system with a field-constructed tank or an airport hydrant system that was permanently closed before June 13, 2022 shall assess the excavation zone and permanently close the UST system in accordance with COMAR 26.10.10 if a spill, release, or discharge from the UST system may, in the judgment of the Department, pose a current or potential threat to human health and the environment.</text>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Access, Reporting, and Recordkeeping.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of a UST system with a field-constructed tank or an airport hydrant system shall comply with the access, reporting, and recordkeeping requirements in COMAR 26.10.04.05.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of an airport hydrant system shall comply with the recordkeeping requirements for the additional areas to be inspected during walkthrough inspections in accordance with Regulation .04C of this chapter and COMAR 26.10.04.03 and 26.10.04.05.</text>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of a UST system with a field-constructed tank or an airport hydrant system shall comply with the recordkeeping requirements for release detection in accordance with Regulation .05E of this chapter and COMAR 26.10.04.05 and 26.10.05.06.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-411.2, 4-415.1, 4-417, 4-701 et seq., and 7-201 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: February 15, 1993 (20:3 Md. R. 259)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .01 amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04F amended effective December 6, 1993 (20:24 Md. R. 1865); July 15, 1996 (23:14 Md. R. 1011)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04G amended effective July 15, 1996 (23:14 Md. R. 1011)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05C, D amended effective December 6, 1993 (20:24 Md. R. 1865)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06D amended effective July 15, 1996 (23:14 Md. R. 1011)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07B amended effective July 15, 1996 (23:14 Md. R. 1011)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .08A, B amended effective December 6, 1993 (20:24 Md. R. 1865)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.15 repealed and new Regulations .01—.07 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="13" heading="Oil-Contaminated Soil">
    <regulation prefix="Regulation" num=".01" heading="Scope.">
      <paragraph num="A.">
        <text>This chapter applies to an owner, an operator, and a person in charge of an oil-contaminated soil (OCS) facility.</text>
      </paragraph>
      <paragraph num="B.">
        <text>This chapter is not intended to and does not relieve an owner, an operator, and a person in charge of an OCS facility of the duty to comply with all other applicable requirements of COMAR 26.10.</text>
      </paragraph>
      <paragraph num="C.">
        <text>This chapter does not affect the Department’s authority to direct a corrective action conducted in response to an oil spill, release, or discharge in accordance with the requirements of COMAR 26.10.01 and 26.10.08—26.10.10.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Definitions.">
      <paragraph num="A.">
        <text>In this chapter:</text>
        <paragraph num="(1)">
          <text>A term defined in §B of this regulation has the meaning indicated; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A term not defined in §B of this regulation has the meaning given to it in:</text>
          <paragraph num="(a)">
            <text>A relevant statute;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>COMAR 26.10.01 or 26.10.02; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>If not defined in a statute or COMAR 26.10.01 or 26.10.02, the meaning attributed by common use.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>“Controlled hazardous substance (CHS)” means a hazardous waste as defined in COMAR 26.13.02, except as provided in COMAR 26.13.02.06.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>“Mobile treatment OCS facility” means equipment that is:</text>
          <paragraph num="(a)">
            <text>Capable of being moved from place to place;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Capable of treating OCS after it is excavated; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Used on-site.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>OCS.</text>
          <paragraph num="(a)">
            <text>“OCS” means excavated soil that has been in contact with oil.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“OCS” does not include post-treatment soil.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>OCS Facility.</text>
          <paragraph num="(a)">
            <text>“OCS facility” means a facility that receives OCS for treatment and storage.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“OCS facility” includes a mobile treatment OCS facility.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>OCS Treatment Approval.</text>
          <paragraph num="(a)">
            <text>“OCS treatment approval” means written permission from the Department that grants an applicant approval to conduct a pilot project to treat OCS.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“OCS treatment approval” does not include an Individual Oil Operations Permit issued by the Department to an owner, an operator, and a person in charge of an OCS facility.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>“On-site” means the immediate location where the OCS was generated.</text>
        </paragraph>
        <paragraph num="(7)">
          <text>“Pilot project” means an experimental OCS treatment project conducted by an owner, an operator, and a person in charge of an OCS facility under the terms and conditions of an OCS treatment approval.</text>
        </paragraph>
        <paragraph num="(8)">
          <text>“Post-treatment soil” means treated OCS that meets one of the criteria established in Regulation .10 of this chapter.</text>
        </paragraph>
        <paragraph num="(9)">
          <text>“Shelter” means a freestanding structure that includes a roof or an equivalent protective cover and prevents the infiltration of rainwater.</text>
        </paragraph>
        <paragraph num="(10)">
          <text>“TCLP” means the toxicity characteristic leaching procedure, as defined in USEPA Test Method 1311.</text>
        </paragraph>
        <paragraph num="(11)">
          <text>“TPH” means total petroleum hydrocarbons.</text>
        </paragraph>
        <paragraph num="(12)">
          <text>“Treatment” means any activity or process at an OCS facility that decreases or stabilizes, or is intended to decrease or stabilize, the level of oil contaminants in OCS.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Permits, Approvals, and Prohibitions.">
      <paragraph num="A.">
        <text>A person shall only store OCS at an OCS facility covered under an Individual Oil Operations Permit.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an OCS facility may not accept OCS for storage or treatment without first obtaining an Individual Oil Operations Permit in accordance with Regulations .04 and .05 of this chapter and COMAR 26.10.01.09 and .11.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Before beginning a pilot project to treat OCS, a person shall obtain an OCS treatment approval from the Department in accordance with Regulation .16 of this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Permit Application Requirements.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an OCS facility shall obtain an Individual Oil Operations Permit in accordance with the requirements of this regulation and COMAR 26.10.01.09 and .11.</text>
      </paragraph>
      <paragraph num="B.">
        <text>A person applying for an Individual Oil Operations Permit to operate an OCS facility shall include on forms provided by the Department all of the following information:</text>
        <paragraph num="(1)">
          <text>A general description of the proposed OCS facility, including a description of the treatment process, anticipated production volume, and OCS acceptance procedures;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The name, physical address, and mailing address of the owner of the proposed OCS facility;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If different than the owner specified in §B(2) of this regulation, the name, physical address, and mailing address of the owner of the property on which the OCS facility will be located;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The size of property on which the OCS facility will be located;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>The name, physical address, and mailing address of each adjoining property owner; and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>One copy of each of the following documents:</text>
          <paragraph num="(a)">
            <text>A map that delineates the property and the surrounding ¼ mile area, identifying:</text>
            <paragraph num="(i)">
              <text>The location of all potable wells, wetlands, floodplains, special flood hazard areas, and intermittent and other surface waters; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Each property owner identified in §B(5) of this regulation;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>A to-scale diagram of the OCS facility that depicts the:</text>
            <paragraph num="(i)">
              <text>Treatment and storage areas for OCS and post-treatment soil;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Storm drains and stormwater retention ponds located at the facility;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Roads located within the property boundaries of the OCS facility; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Existing and proposed structures;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>A description of the following features and utilities at the facility:</text>
            <paragraph num="(i)">
              <text>Vehicle weighing facilities;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Both wired and wireless communications equipment, including telephones and radios;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Maintenance facilities;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Equipment storage facilities;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>The location of the OCS facility site supply well, if one is present; and</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>The location of the sewerage system;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>A description of the proposed soil types and sources of OCS to be accepted and rejected by the OCS facility;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>A description of how the OCS facility will control dust, petroleum vapors, and odors;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>A description of the manner in which OCS and post-treatment soil will be stored at the facility to prevent the contamination of waters of the State while maintaining compliance with the storage requirements of Regulation .07 of this chapter;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>The name, physical address, and mailing address of the laboratory to be used to test OCS and post-treatment soil samples, and a description of the sampling and analytical protocols to be used for testing OCS and post-treatment soil;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>The maximum and anticipated average quantity of:</text>
            <paragraph num="(i)">
              <text>OCS to be accepted or stored at the OCS facility at any one time; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Post-treatment soil to be stored at the OCS facility at any one time;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(i)">
            <text>The proposed method of controlling unauthorized access to the OCS facility;</text>
          </paragraph>
          <paragraph num="(j)">
            <text>The proposed operating procedures, including:</text>
            <paragraph num="(i)">
              <text>Hours and days of operation;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The type and number of pieces of equipment to be used;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The number of employees and description of individual employee duties;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The provisions for fire prevention and control;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>The provisions for wet weather operations;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>The methods for controlling stormwater run-off from the OCS facility and stormwater run-on onto the OCS facility from adjoining areas; and</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>The erosion and sediment control provisions approved by the appropriate approving authority;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(k)">
            <text>An operations manual that includes:</text>
            <paragraph num="(i)">
              <text>Standard operating procedures for the OCS facility;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>OCS acceptance procedures;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Sample collection, storage, and analytical procedures;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The names and duties of key personnel;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Facility maintenance procedures; and</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>A quality assurance/quality control plan to ensure OCS is properly treated and post-treatment soil meets the requirements of Regulation .10 of this chapter;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(l)">
            <text>Except for an application for a mobile treatment OCS facility, a closure plan for the proposed OCS facility that includes, at a minimum:</text>
            <paragraph num="(i)">
              <text>The location and installation details of monitoring wells that will allow for the determination of groundwater flow and that are placed in areas that are most likely to detect a spill, release, or discharge from the OCS facility;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Procedures for the removal of all OCS from the OCS facility;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Procedures for the removal of post-treatment soil from the OCS facility; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Procedures, schedules, and methods for monitoring the waters of the State at the OCS facility for five years after the closure of the facility;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(m)">
            <text>For an application for a mobile treatment OCS facility, a closure plan for the proposed mobile treatment OCS facility that includes, at a minimum:</text>
            <paragraph num="(i)">
              <text>Procedures for the removal of all OCS not treated by the mobile treatment OCS facility on-site, and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Procedures for the removal of post-treatment soil stored on-site; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(n)">
            <text>Written consent from the owner of the property on which the proposed OCS facility is to be located, as identified in §B(3) of this regulation, stating the proposed OCS facility may be located and operated on the property.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Upon review of an application completed in accordance with this regulation, the Department shall:</text>
        <paragraph num="(1)">
          <text>Notify the applicant in writing that the application is not complete and additional information is required to determine whether the proposed OCS facility is consistent with all applicable requirements of this chapter, COMAR 26.10, and other State laws and regulations;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Issue an Individual Oil Operations Permit to the applicant in accordance with COMAR 26.10.01.11G and H; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Deny the application for an Individual Oil Operations Permit in accordance with COMAR 26.10.01.12.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Renewal of an Individual Oil Operations Permit.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of an OCS facility shall:</text>
          <paragraph num="(a)">
            <text>Except as provided in §D(1)(b) of this regulation, apply to renew an Individual Oil Operations Permit in accordance with §§A and B of this regulation and COMAR 26.10.01.11; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Submit an application for renewal at least 90 days before the expiration of an Individual Oil Operations Permit.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Unless otherwise directed by the Department, an owner, an operator, and a person in charge of an OCS facility is not required to hold an informational meeting in accordance with Regulation .05 of this chapter when renewing an Individual Oil Operations Permit.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Informational Meeting.">
      <paragraph num="A.">
        <text>Informational Meeting Requirement.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of a proposed OCS facility applying for an Individual Oil Operations Permit shall hold an informational meeting.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The Department may require an owner, an operator, and a person in charge of the OCS facility to hold an informational meeting before:</text>
          <paragraph num="(a)">
            <text>Renewing an Individual Oil Operations Permit;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Reinstating a suspended or revoked Individual Oil Operations Permit; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Modifying an Individual Oil Operations Permit.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>A person responsible for holding an informational meeting shall:</text>
        <paragraph num="(1)">
          <text>Secure an approved meeting venue located in the political subdivision and in close proximity to the OCS facility; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At least 15 days but not more than 30 days before the date of the meeting, publish a notice advertising the informational meeting:</text>
          <paragraph num="(a)">
            <text>At least once a week for two consecutive weeks in a daily or weekly newspaper of general circulation in the geographical area in which the OCS facility is or will be located; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>That includes the following information:</text>
            <paragraph num="(i)">
              <text>The name and address of the owner of the OCS facility;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>A description of where the OCS facility would be located;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The nature of the proposed activity to be performed under the Individual Oil Operations Permit;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>A reference to the applicable statutes or regulations governing the application process;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>The time and place of the meeting or a description of where this information can be found;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>A description of where further information about the Individual Oil Operations Permit application or the revoked or suspended Individual Oil Operations Permit can be found; and</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>Any other information that the Department determines is necessary.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>The Department may consolidate an informational meeting provided in accordance with this regulation with other informational meetings for the OCS facility.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Permit and Operational Requirements.">
      <paragraph num="A.">
        <text>The Department shall specify the following requirements in an Individual Oil Operations Permit for an OCS facility other than a mobile OCS treatment facility:</text>
        <paragraph num="(1)">
          <text>The maximum quantities of OCS and post-treatment soil to be stored at the OCS facility at any given time;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The methods used to store OCS and post-treatment soil;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The methods of stormwater run-on and run-off control;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The sampling and testing requirements for accepted OCS;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>The testing requirements for post-treatment soil;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>The recordkeeping requirements for the following records at the OCS facility:</text>
          <paragraph num="(a)">
            <text>OCS acceptance documents;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>OCS and post-treatment soil testing records;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>OCS and post-treatment soil laboratory analyses; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Documentation for OCS deliveries made to the OCS facility, including refused OCS deliveries, showing:</text>
            <paragraph num="(i)">
              <text>The generator’s name and physical and mailing addresses;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The OCS source; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The transporter’s name and physical and mailing addresses;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>A closure plan prepared in accordance with Regulation .04B of this chapter;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>A schedule for testing the quality of waters of the State at the OCS facility; and</text>
        </paragraph>
        <paragraph num="(9)">
          <text>A description of the field and laboratory analytical methods that will be used to monitor the quality of waters of the State at the OCS facility, including the location and types of monitoring stations and monitoring well construction method.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The Department shall specify the following requirements in an Individual Oil Operations Permit for a mobile treatment OCS facility:</text>
        <paragraph num="(1)">
          <text>The requirements listed in §A(3)—(6);</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The method used for staging OCS on-site; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Closure plan requirements, including procedures for:</text>
          <paragraph num="(a)">
            <text>The removal of OCS not treated by the mobile treatment OCS facility on-site; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The removal of post-treatment soil generated on-site.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an OCS facility shall comply with the following operational requirements:</text>
        <paragraph num="(1)">
          <text>Maintain an up to date operations manual at the OCS facility and make the operations manual available to all OCS facility personnel;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Train all OCS facility personnel in facility operations, standard operating procedures, and contingency plans;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Restrict unloading and loading of OCS to approved facility operational hours;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Maintain adequate personnel and equipment at the OCS facility at all times to ensure proper operation and prompt response to problems associated with loading, unloading, and storage of OCS;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Keep and make available to the Department upon request all of the records required under this chapter for:</text>
          <paragraph num="(a)">
            <text>The duration of an active Individual Oil Operations Permit; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An additional five years after the permit has expired or been closed by the Department;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>In accordance with the reporting requirements of COMAR 26.10.01.05, notify the Department of an operational malfunction at the OCS facility that results in a spill, release, or discharge within 2 hours of the operational malfunction;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>At the direction of the Department during the operational life of the facility, sample monitoring wells and analyze the quality of waters of the State at the OCS facility; and</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Submit an annual written report by January 30 of each year to the Department that provides the following information for the preceding calendar year:</text>
          <paragraph num="(a)">
            <text>The quantity of OCS received,</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The origin of OCS received, and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The quantity of OCS treated and converted into post-treatment soil at an OCS facility.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>In addition to the permit conditions specified in §§A and B of this regulation, the Department may include additional special conditions in an Individual Oil Operations Permit if the Department determines the special conditions are necessary to protect public health or the environment.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Storage Requirements.">
      <paragraph num="A.">
        <text>Unless otherwise approved by the Department as a condition of a new, renewal, or modified Individual Oil Operations Permit, an owner, an operator, and a person in charge of an OCS facility shall store OCS:</text>
        <paragraph num="(1)">
          <text>On an impermeable base that has a permeability of 10-7 centimeters/second or less;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Under a shelter; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>At a volume that does not exceed a 90-day treatment capacity.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an OCS facility may not accept or store OCS that does not meet the requirements of Regulation .08 of this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Acceptance Requirements.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an OCS facility:</text>
        <paragraph num="(1)">
          <text>May accept OCS that:</text>
          <paragraph num="(a)">
            <text>Contains virgin oil; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If the origin of the OCS is unknown, has undergone the laboratory analysis required under §D of this regulation; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>May not accept OCS that:</text>
          <paragraph num="(a)">
            <text>Contains free phase oil product, oil sludge, oil refuse, or oil mixed with other waste that has been mixed with soil;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Is regulated as a CHS under COMAR 26.13; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Does not meet the conditions of an Individual Oil Operations Permit.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Except as otherwise provided in §C of this regulation, an owner, an operator, and a person in charge of an OCS facility shall obtain the following documentation prior to accepting OCS at the OCS facility:</text>
        <paragraph num="(1)">
          <text>An analytical laboratory report that shows the results of analysis for TPH conducted in accordance with:</text>
          <paragraph num="(a)">
            <text>USEPA Test Method 8015; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Another method determined by the Department as appropriate for the type of oil that was spilled, released, or discharged; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>One of the following forms that attest to the origin of the OCS and states that a representative of the Department or another authorized person has reason to believe, based upon evidence presented to the person on-site, that the OCS complies with §A of this regulation:</text>
          <paragraph num="(a)">
            <text>A Tank Closure Form or Oil Contaminated Soil Removal Form provided and completed by an authorized representative of the Department;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Another form similar to a form listed in §B(2)(a) of this regulation provided and completed by an authorized representative of:</text>
            <paragraph num="(i)">
              <text>A State or local enforcement agency, such as a local fire department, police agency, or an emergency response unit owned by the enforcement agency or hired by the enforcement agency to conduct a removal of an oil spill, release or discharge; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If the OCS originates from out of state, an enforcement agency of another state enforcing an oil regulatory program;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>If the OCS is related to the closure of a UST system, underground farm tank, underground residential tank, or underground residential heating oil tank performed in accordance with COMAR 26.10.10, a form provided by the owner, the operator, and the person in charge the OCS facility that was completed by the OCS generator that includes the following information:</text>
            <paragraph num="(i)">
              <text>The OCS facility name and physical address;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The printed name and signature of the OCS facility representative;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The printed name, signature, and certification number of the certified UST system technician or remover;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The UST owner’s name and physical and mailing addresses;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>The Department assigned case number for the UST closure;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>The reason for removing the OCS; and</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>A signed statement that the OCS is the result of a spill, release, or discharge of virgin oil and not used oil, oil refuse, or oil mixed with waste; or</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>If the OCS is related to a commercial transportation spill, release, or discharge and one of the documents described in §B(2)(a)—(c) of this regulation cannot be provided, an affidavit completed by the owner or knowledgeable representative of the responsible party confirming that the OCS complies with §A of this regulation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>If the documentation described under §B of this regulation cannot be provided or the OCS was contaminated by a substance other than virgin oil, an owner, an operator, and a person in charge of an OCS facility shall obtain an analytical laboratory report provided by the generator with the results of an analysis conducted in accordance with §D of this regulation prior to accepting OCS at the OSC facility.</text>
      </paragraph>
      <paragraph num="D.">
        <text>An owner, an operator, and a person in charge of an OCS facility accepting OCS of an unknown origin shall ensure the OCS undergoes an analytical laboratory analysis as follows:</text>
        <paragraph num="(1)">
          <text>An evaluation for the following oil constituents:</text>
          <paragraph num="(a)">
            <text>TPH, in accordance with the procedures of USEPA Test Method 8015 or another method determined by the Department as appropriate for the type of oil that was spilled, released, or discharged; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Polychlorinated biphenyls, in accordance with the procedures of USEPA Test Method 8082A or another method approved by the Department; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A complete TCLP analysis is conducted in accordance with USEPA Test Method 1311, except that:</text>
          <paragraph num="(a)">
            <text>The TCLP analysis may be limited to metals only if the generator of the OCS has certified that:</text>
            <paragraph num="(i)">
              <text>If the OCS was generated within the State, the OCS is excluded under COMAR 26.13.02.04A(12); or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If the OCS was generated outside the State, the OCS is excluded under 40 CFR §261.4(b)(10) or an equivalent requirement of that state; or</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Pesticides or herbicides may be omitted from the TCLP analysis if the generator of the OCS certifies that pesticides or herbicides are not reasonably expected to be present.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>An owner, an operator, and a person in charge of an OCS Facility may be found in violation of Environment Article, §7-224, Annotated Code of Maryland if:</text>
        <paragraph num="(1)">
          <text>Any person, including the Department, determines through subsequent analytical analyses or a review of records that OCS accepted, stored, or treated at the OCS facility is a CHS; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The OCS facility does not operate under a valid CHS Facility Permit issued by the Department under COMAR 26.13.07.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>An owner, an operator, and a person in charge of an OCS facility shall maintain all records, documents, and analytical laboratory reports required under §§B—D this regulation for:</text>
        <paragraph num="(1)">
          <text>The duration of an active Individual Oil Operations Permit; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An additional five years after an Individual Oil Operations Permit has expired or been closed by the Department.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".09" heading="Refusal Criteria.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an OCS facility shall refuse to accept OCS that does not meet the acceptance requirements of Regulation .08 of this chapter.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Upon determination that an OCS facility accepted OCS that does not meet the requirements of Regulation .08 of this chapter, an owner, an operator, and a person in charge of the OCS facility shall:</text>
        <paragraph num="(1)">
          <text>Isolate and remove the unacceptable OCS from the OCS facility within 48 hours; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Ensure the OCS removed from the OCS facility is disposed of in compliance with applicable federal, State, and local laws and regulations.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>For each instance of OCS refused in accordance with §§A and B of this regulation, an owner, an operator, and a person in charge of an OCS facility shall provide notification of the refusal to the Department as follows:</text>
        <paragraph num="(1)">
          <text>Provide notification by telephone within 24 hours and written notification within five days of the refusal; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Include the following information in the notifications:</text>
          <paragraph num="(a)">
            <text>The source location and generator of the OCS; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The transporter who delivered or attempted to deliver the OCS.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".10" heading="Post-Treatment Requirements.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an OCS facility shall treat OCS using a process that generates post-treatment soil meeting one of the following criteria:</text>
        <paragraph num="(1)">
          <text>The post-treatment soil has a TPH concentration of 10 mg/kg or less, as measured by USEPA Test Method 8015;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Remaining oil in the post-treatment soil is determined to be physically and chemically bound with TPH-diesel range organics concentration of less than 0.5 mg/L, determined by:</text>
          <paragraph num="(a)">
            <text>Preparing a leachate sample from the post-treatment soil in accordance with USEPA Test Method 1311; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Analyzing the leachate sample for TPH-diesel range organics using USEPA Test Method 8015; or</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Post-treatment soil that meets an alternative criterion established by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>If treated OCS does not meet one of the criteria established in §A of this regulation, an owner, an operator, and a person in charge of an OCS facility shall:</text>
        <paragraph num="(1)">
          <text>Continue the treatment process for the partially treated OCS until one of the criteria established in §A of this regulation is met; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Except as otherwise provided in §C of this regulation, dispose of the partially treated OCS in compliance with applicable federal, State, and local laws and regulations.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>The Department may approve a request to remove partially treated OCS from an OCS facility for use if the Department determines that the proposed use will not adversely affect public health, safety, or welfare or the environment.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".11" heading="Quality Control, Sample Collection, and Analysis.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an OCS facility shall maintain a quality control program approved by the Department that establishes an adequate tracking mechanism and verification for OCS received by the facility.</text>
      </paragraph>
      <paragraph num="B.">
        <text>For each truckload of OCS received by an OCS facility, an owner, an operator, and a person in charge of the OCS facility shall:</text>
        <paragraph num="(1)">
          <text>Collect a grab sample from the incoming truckload of OCS and combine not more than three grab samples to form one composite sample;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Identify each composite sample by source, date received, and transporter; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Unless otherwise directed by the Department, properly maintain each composite sample at the OCS facility for a minimum of 90 days.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>At least every two weeks, an owner, an operator, and a person in charge of an OCS facility shall have a third-party testing laboratory approved by the Department analyze the composite samples collected in accordance with §B of this regulation as follows:</text>
        <paragraph num="(1)">
          <text>The testing laboratory shall randomly select one composite sample and perform:</text>
          <paragraph num="(a)">
            <text>An analysis for polychlorinated biphenyls in accordance with USEPA Test Method 8082A or another method approved by the Department; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Unless the generator of the OCS certified the OCS is excluded under 40 CFR §261.4(b)(10) and a TCLP analysis limited to metals was performed, a complete TCLP analysis in accordance with USEPA Test Method 1311 or another method approved by the Department; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The testing laboratory shall submit the results of the analyses conducted pursuant to §C(1) of this regulation directly to the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>The Department may excuse an owner, an operator, and a person in charge of an OCS facility from the requirements under §C of this regulation if the owner, the operator, and the person in charge sends a letter to the Department certifying that no OCS was accepted during the relevant 2-week period.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".12" heading="Use of Post-Treatment Soils.">
      <paragraph num="A.">
        <text>The Department may specify in an Individual Oil Operations Permit restrictions on the use of post-treatment soil.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an OCS facility shall be responsible for determining the federal, State, and local laws and regulations that apply to the use of post-treatment soil.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".13" heading="Closure Requirements.">
      <paragraph num="A.">
        <text>Closure Plan Modifications. Subject to the approval of the Department, an owner, an operator, and a person in charge of an OCS facility shall modify a closure plan if:</text>
        <paragraph num="(1)">
          <text>The operational history of the OCS facility or changes in conditions, such as changes to land use conditions at the site, substantially affect the closure plan in effect;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Before or after closure activities have commenced, unanticipated events necessitate a revision to the closure plan; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The Department determines a modification of the closure plan is necessary.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Initiation of Closure. An owner, an operator, and a person in charge of an OCS facility shall initiate the closure of the OCS facility within 90 days of one of the following occurrences:</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of an OCS facility determines the OCS facility will no longer be operational;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The OCS facility has suspended OCS treatment activities for greater than six continuous months; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A condition for closure specified in the Individual Oil Operations Permit occurs.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Closure Procedures. An owner, an operator, and a person in charge of an OCS facility shall close the OCS facility in accordance with the closure plan approved by the Department and meet the following requirements:</text>
        <paragraph num="(1)">
          <text>Remove all OCS from the OCS facility that has not undergone treatment;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Unless otherwise allowed in the Individual Oil Operations Permit, remove all post-treatment soil from the OCS facility;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>In accordance with a testing schedule and field and laboratory analytical methods specified by the Department under Regulation .06A of this chapter, monitor the quality of the waters of the State for at least 5 years after completing closure; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Following the conclusion of the 5-year period for monitoring waters of the State, properly abandon any monitoring wells in accordance with COMAR 26.04.04.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Closure of an Individual Oil Operations Permit.</text>
        <paragraph num="(1)">
          <text>If an Individual Oil Operations Permit only authorizes the operation of an OCS facility, an owner, an operator, and a person in charge of a closed OCS facility may request the Department close the Individual Oil Operations Permit.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Upon the request of an owner, an operator, and a person in charge of an OCS facility, the Department shall close an Individual Oil Operations Permit if the Department determines the closure of the OCS facility was satisfactorily completed in accordance with the closure plan, the Individual Oil Operation Permit, this chapter, and, if applicable, COMAR 26.10.09.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".14" heading="Right of Entry.">
      <text>An owner, an operator, and a person in charge of an OCS facility shall allow, as a prerequisite to the issuance of an Individual Oil Operations Permit, the Department to access the OCS facility and all records related to the operation of the OCS facility in accordance with, and for any of the purposes stated in, COMAR 26.10.01.19.</text>
    </regulation>
    <regulation prefix="Regulation" num=".15" heading="Denial, Suspension, Revocation, and Modification of an Individual Oil Operations Permit.">
      <paragraph num="A.">
        <text>Denial, Suspension, or Revocation. The Department may deny an application for an Individual Oil Operations Permit or suspend or revoke an Individual Oil Operations Permit in accordance with COMAR 26.10.01.12B.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Modification.</text>
        <paragraph num="(1)">
          <text>The Department may modify an Individual Oil Operations Permit in accordance with COMAR 26.10.01.12B.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If an owner, an operator, and a person in charge of an OCS facility requests to modify an Individual Oil Operations Permit, the owner, the operator, and the person in charge shall submit a request for the modification to the Department in accordance with COMAR 26.10.01.12B.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If the Department determines a proposed modification to an Individual Oil Operations Permit is substantial in nature, an owner, an operator, and a person in charge of an OCS facility shall hold an informational meeting in accordance with Regulation .05 of this chapter.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".16" heading="Oil-Contaminated Soil Treatment Pilot Project.">
      <paragraph num="A.">
        <text>The Department may issue an OCS treatment approval to a person to conduct a pilot project that may deviate from one or more requirements in Regulations .07—.11 of this chapter, if the pilot project will:</text>
        <paragraph num="(1)">
          <text>Accept, store, and treat OCS in a manner as protective to the public health, safety, and wellness and the environment as the requirements established in Regulations .07—.11 of this chapter; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Comply with all other applicable federal, State, and local government laws and regulations.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The Department shall establish the application process and conditions of an OCS treatment approval.</text>
      </paragraph>
      <paragraph num="C.">
        <text>A person seeking to conduct a pilot project shall:</text>
        <paragraph num="(1)">
          <text>First, obtain an Individual Oil Operations Permit in accordance with Regulation .04 of this chapter; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Second, obtain OCS treatment approval from the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>An OCS treatment approval is valid for the length of time specified by the Department in the OCS treatment approval, but may not exceed one year.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-411, and 4-415—4-418, Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date:</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.15 adopted as an emergency provision effective January 18, 1993 (20:3 Md. R. 256); adopted permanently effective July 18, 1993 (20:13 Md. R. 1050)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03D amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04A amended effective February 18, 2002 (29:3 Md. R. 224)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.15 repealed and new Regulations .01—.16 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="14" heading="Residential Heating Oil Tank System Site Rehabilitation Reimbursement Program">
    <regulation prefix="Regulation" num=".01" heading="Scope.">
      <paragraph num="A.">
        <text>This chapter provides the mechanisms for reimbursing a residential owner of a residential heating oil tank system for certain site rehabilitation costs, as authorized under Environment Article, §4-704(b)(1)(iii), Annotated Code of Maryland.</text>
      </paragraph>
      <paragraph num="B.">
        <text>This chapter may not be construed:</text>
        <paragraph num="(1)">
          <text>As altering the rights, responsibilities, or liabilities of a person responsible for the discharge; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>As entitling a residential owner to reimbursement of site rehabilitation costs.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Exclusions.">
      <text>This chapter does not provide reimbursements for:</text>
      <paragraph num="A.">
        <text>Site rehabilitation costs for residential heating oil tank systems incurred before October 1, 2000;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Site rehabilitation costs that result from a spill, release, or discharge of oil originating from a source other than a residential heating oil tank system;</text>
      </paragraph>
      <paragraph num="C.">
        <text>Costs resulting from:</text>
        <paragraph num="(1)">
          <text>Residential heating oil tank system closures in place, upgrades, or replacements; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Retrofitting of a residential heating oil tank or associated piping;</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Except as otherwise provided in Regulation .05 of this chapter, costs resulting from a residential heating oil tank system removal;</text>
      </paragraph>
      <paragraph num="E.">
        <text>A third-party claim; or</text>
      </paragraph>
      <paragraph num="F.">
        <text>Site rehabilitation costs that have been paid or are payable under an insurance policy.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Definitions.">
      <paragraph num="A.">
        <text>In this chapter:</text>
        <paragraph num="(1)">
          <text>The terms in §B of this regulation have the meanings indicated; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A term not defined in §B of this regulation has the meaning given to it in the relevant statutes and in COMAR 26.10.01.02 or, if not defined there, the meaning in the ordinary dictionary definition of the term.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>“Approved application” means an application that has been submitted by a qualified residential owner in accordance with Regulation .06 of this chapter and has been approved by the Department for a reimbursement allocation.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>“Department” means the Maryland Department of the Environment.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>“Fund” means the Oil Contaminated Site Environmental Cleanup Fund.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>“Occurrence” means the existence of contamination resulting from a spill, release, or discharge of oil from one or more residential heating oil tank systems at a site.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>“Oil” has the meaning stated in COMAR 26.10.01.02B.</text>
        </paragraph>
        <paragraph num="(6)">
          <text>“Reimbursement allocation” means an amount of money from the Fund set aside for an approved application to reimburse a residential owner for site rehabilitation costs incurred, or to be incurred, during the remediation of the site approved on the application as allowed under this chapter.</text>
        </paragraph>
        <paragraph num="(7)">
          <text>“Residential heating oil tank” means an aboveground or underground heating oil tank that meets the criteria under Environment Article, §4-401(e), Annotated Code of Maryland that is used to store heating oil for use as a fuel in heating a single-family residential property.</text>
        </paragraph>
        <paragraph num="(8)">
          <text>“Residential heating oil tank system” means a residential heating oil tank and all associated piping, including, but not limited to, fill, vent, dispensing, and return line pipes.</text>
        </paragraph>
        <paragraph num="(9)">
          <text>“SDAT” means the State Department of Assessments and Taxation.</text>
        </paragraph>
        <paragraph num="(10)">
          <text>“Site” means a single-family residential property where a person owns one or more residential heating oil tank systems that is the source of a spill, release, or discharge of oil, including any soil, groundwater, or surface water at the single-family residential property or a neighboring property affected by the spill, release, or discharge of oil.</text>
        </paragraph>
        <paragraph num="(11)">
          <text>Site Rehabilitation.</text>
          <paragraph num="(a)">
            <text>“Site rehabilitation” means cleanup actions taken in response to a spill, release, or discharge of oil from a residential heating oil tank system.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Site rehabilitation” includes investigation, evaluation, planning, design, engineering, construction, or other services undertaken and expenses incurred to investigate or clean up affected soils, groundwater, or surface water.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(12)">
          <text>“Supervisor” has the meaning stated in Tax-Property Article, §1-101(mm), Annotated Code of Maryland.</text>
        </paragraph>
        <paragraph num="(13)">
          <text>“Value” has the meaning stated in Tax-Property Article, §1-101(qq), Annotated Code of Maryland, as determined by the most recent SDAT assessment in accordance with Tax-Property Article, §§8-101—8-104, Annotated Code of Maryland.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Reimbursement Process.">
      <paragraph num="A.">
        <text>A residential owner of a residential heating oil tank system seeking reimbursement from the Fund shall apply to the Department in accordance with the application requirements in Regulation .06 of this chapter.</text>
      </paragraph>
      <paragraph num="B.">
        <text>The Department may reimburse a residential owner with an approved application to the extent there are available revenues in the Fund and in accordance with the reimbursement limitations and deducible requirement in Regulation .08 of this chapter.</text>
      </paragraph>
      <paragraph num="C.">
        <text>The Secretary of the Environment or a designee shall:</text>
        <paragraph num="(1)">
          <text>Make all final decisions regarding reimbursement matters; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Adjust reimbursement allocations if substantial need is demonstrated.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Site Rehabilitation Costs.">
      <paragraph num="A.">
        <text>Eligible Site Rehabilitation Costs. The Department may reimburse a residential owner of a residential heating oil tank system for eligible site rehabilitation costs incurred in performing the following activities if the Department determines they are cost effective, reasonable, and consistent with an application received on or after July 1, 2005:</text>
        <paragraph num="(1)">
          <text>Soil treatment, including:</text>
          <paragraph num="(a)">
            <text>Excavation, transportation, and proper disposal of oil-contaminated soil; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>On-site treatment, such as soil vapor extraction;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Procurement and installation of groundwater remediation equipment, including soil vapor extraction equipment;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Subsurface investigation, well bailing, recovery system design, operation, monitoring, or a combination of these activities;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Private supply well replacement;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Odor abatement activities, such as forced venting and oil saturated material removal and proper disposal, replacement, or restoration to a degree as determined by the Department to return a residence to a habitable condition;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Closure of a heating oil tank by removal, if the Department determines removal of the heating oil tank is necessary to accomplish soil treatment as described in §A(1)(a) of this regulation; and</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Other site rehabilitation activities performed by a residential owner under the direction and approval of the Department to remediate a spill, release, or discharge of oil from a residential heating oil tank system.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Ineligible Costs. The Department may not reimburse a residential owner of a residential heating oil tank system for costs incurred in performing the following activities:</text>
        <paragraph num="(1)">
          <text>Closure in place of an underground residential heating oil tank;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Installation of a new or replacement residential heating oil tank;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Third-party contractor mobilization or demobilization of equipment, materials, and personnel at a site;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Preparation of a complete application, including preparing or obtaining support documentation; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Performance of activities that are not related to remediation of oil-contaminated soil, groundwater, or surface water at a site so as to mitigate threats to public health, safety, and welfare or the environment, as determined by the Department.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Application Requirements.">
      <paragraph num="A.">
        <text>A residential owner of a residential heating oil tank system may apply to the Department for reimbursement from the Fund:</text>
        <paragraph num="(1)">
          <text>Until the date established by Environment Article, §4-705(b), Annotated Code of Maryland;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Not later than 6 months after the completion of site rehabilitation;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Only for eligible site rehabilitation costs listed in Regulation .05 of this chapter that were incurred on or after October 1, 2000;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Once for the entire period of ownership of the single-family residential property where the residential heating oil tank system is located; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Once per State fiscal year if the residential heating oil tank system is not located at the primary residence of the residential owner.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>A residential owner applying for reimbursement from the Fund shall submit to the Department:</text>
        <paragraph num="(1)">
          <text>A complete and accurate application on a form supplied by the Department;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A current W-9 Identification Number and Certification Form from the federal Department of the Treasury, Internal Revenue Service;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>On a form supplied by the Department, a description of the incurred site rehabilitation costs eligible for reimbursement under Regulation .05 of this chapter, including copies of actual invoices and other proofs of payment for site rehabilitation costs; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>If submitting an application on or after July 1, 2022, a copy of:</text>
          <paragraph num="(a)">
            <text>The online SDAT property database’s search results page for the site; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The most recent property tax assessment notice mailed to the residential owner of the site by the Supervisor in accordance with Tax-Property Article, §8-401, Annotated Code of Maryland.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>A residential owner may submit to the Department additional eligible site rehabilitation costs with the supporting documentation required under §B(3) of this regulation:</text>
        <paragraph num="(1)">
          <text>Following the approval of the application by the Department; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Not later than 6 months after the completion of site rehabilitation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>To be eligible for reimbursement from the Fund, a residential owner shall:</text>
        <paragraph num="(1)">
          <text>Certify to the Department that the spill, release, or discharge of oil resulted from a residential heating oil tank system;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Submit to the Department for its approval:</text>
          <paragraph num="(a)">
            <text>A corrective action plan;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An implementation schedule;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A cost estimate; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>An estimated completion date;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Certify to the Department that the spill, release, or discharge of oil is not the result of a willful or deliberate act;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>As determined by the Department, be in substantial compliance with the applicable requirements under Environment Article, §4-420, Annotated Code of Maryland, COMAR 26.10, and all Maryland laws and regulations applicable to residential heating oil tank systems; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Certify to the Department that the site rehabilitation costs submitted for reimbursement are:</text>
          <paragraph num="(a)">
            <text>True and eligible for reimbursement under Regulation .05 of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Necessary to complete site rehabilitation; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Not excluded under Regulation .02 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>The filing of an application for reimbursement does not relieve the residential owner or any other person from the requirement to take prompt site rehabilitation action as required by law or regulation.</text>
      </paragraph>
      <paragraph num="F.">
        <text>If an applicant knowingly submits a false certification of satisfying the eligibility requirements under §D of this regulation, the residential owner is not eligible for reimbursement.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Application Approval.">
      <paragraph num="A.">
        <text>Application Numerical Ranking.</text>
        <paragraph num="(1)">
          <text>The Department shall assign each application a numerical rank based on the date the complete application was received by the Department, so that the earliest complete application receives the highest rank.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Subject to the availability of revenues within the Fund, the Department shall approve reimbursement allocations for approved applications in order of their numerical ranking.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>A residential owner may submit to the Department, and the Department shall approve not more than one application per State fiscal year for separate single-family residential properties owned by the same person or persons.</text>
      </paragraph>
      <paragraph num="C.">
        <text>If the Department determines that an application is ineligible under this chapter:</text>
        <paragraph num="(1)">
          <text>The Department shall provide written notification to the residential owner that the application was denied; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The residential owner may submit an application for another site for consideration within that State fiscal year.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Reimbursement Limits and Deductibles.">
      <paragraph num="A.">
        <text>A reimbursement of eligible site rehabilitation costs paid from the Fund for an approved application received by the Department on or after July 1, 2005:</text>
        <paragraph num="(1)">
          <text>May not exceed a total of $20,000 per occurrence; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Is subject to a deductible of $500 per occurrence.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>If an approved application was received by the Department on or after July 1, 2022, a reimbursement allocation is limited as follows:</text>
        <paragraph num="(1)">
          <text>If the value of the residential property is less than or equal to $300,000, the reimbursement allocation is:</text>
          <paragraph num="(a)">
            <text>100 percent of the eligible site rehabilitation costs; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Up to a total of $20,000, less the $500 deducible;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>If the value of the residential property is greater than $300,000 and less than or equal to $600,000, the reimbursement allocation is:</text>
          <paragraph num="(a)">
            <text>50 percent of the eligible site rehabilitation costs; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Up to a total of $10,000, less the $500 deductible; or</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>If the value of the residential property is greater than $600,000, the reimbursement allocation is:</text>
          <paragraph num="(a)">
            <text>25 percent of eligible site rehabilitation costs; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Up to a total of $5,000, less the $500 deductible.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".09" heading="Reimbursement Allocations and Payments.">
      <paragraph num="A.">
        <text>Reimbursement Allocation.</text>
        <paragraph num="(1)">
          <text>The Department shall make a reimbursement allocation in accordance with:</text>
          <paragraph num="(a)">
            <text>A complete application received and approved by the Department;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The numerical ranking assigned to an approved application in accordance with Regulation .07A of this chapter;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The reimbursement limit and deductible requirements established in Regulation .08 of this chapter; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The availability of revenues within the Fund.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Upon the approval of a complete application, the Department shall reserve a reimbursement allocation within the Fund in accordance with §A of this regulation to pay for a reimbursement of site rehabilitation costs that are otherwise eligible under this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Payment of an Approved Reimbursement.</text>
        <paragraph num="(1)">
          <text>Subject to §B(2) and (3) of this regulation, the Department may issue a reimbursement payment to a residential owner for eligible site rehabilitation costs from allocated funds.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In order to issue a reimbursement payment from allocated funds, the Department may request that a residential owner provide a recent W-9 Identification Number and Certification Form from the federal Department of the Treasury, Internal Revenue Service.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The Department reserves the right to deny a reimbursement payment in whole or in part if the Department determines that:</text>
          <paragraph num="(a)">
            <text>A residential owner is disregarding or has disregarded the oil pollution control and abatement requirements under Environment Article, §4-401 et seq., Annotated Code of Maryland;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The reimbursement has been or is being used, or site rehabilitation work has been or is being conducted, in a manner inconsistent with the goals of the site rehabilitation;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The residential owner is not proceeding with the site rehabilitation or has abandoned the site;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The residential owner is not in compliance with all Maryland laws and regulations applicable to oil and residential heating oil tank systems;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The residential owner has not submitted any eligible site rehabilitation costs and supporting documentation of those costs within 6 months of completing the site rehabilitation, unless extended in writing by the Department; or</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Any other good cause exists for denying a reimbursement payment, as determined by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Any reimbursement allocation left unpaid will be released for other Fund uses.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".10" heading="Auditing.">
      <paragraph num="A.">
        <text>Upon request of the Department, a residential owner who applied for reimbursement from the Fund shall submit records that document all costs incurred and monies reimbursed to date for a site rehabilitation within:</text>
        <paragraph num="(1)">
          <text>6 months of completing the site rehabilitation; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>3 years of receiving the final payment from the reimbursement allocation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The Department reserves the right to audit all costs, expenses, or files associated with the Fund.</text>
      </paragraph>
      <paragraph num="C.">
        <text>A residential owner shall maintain all records associated with a site rehabilitation for at least 3 years after the later of:</text>
        <paragraph num="(1)">
          <text>Receiving the final payment from the reimbursement allocation; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Completion of the site rehabilitation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>If an audit reveals any amount of money was improperly paid from the Fund to a residential owner, the residential owner shall return that amount to the Department within 30 days of notification by the Department of the improper payment from the Fund.</text>
      </paragraph>
      <paragraph num="E.">
        <text>A residential owner is liable for any expenses incurred by the Department in collecting money owed under §D of this regulation.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-407—4-411.2, 4-415, 4-415.1, and 4-701 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date:</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.11 adopted as an emergency provision effective November 18, 1993 (20:25 Md. R. 1937); adopted permanently effective May 19, 1994 (21:9 Md. R. 753)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective February 24, 1997 (24:4 Md. R. 295)</annotation>
      <annotation type="History" subtype="Administrative History">Chapter revised effective July 23, 2001 (28:14 Md. R. 1324)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .02D amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .03B amended effective April 19, 2010 (37:8 Md. R. 621)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .04C amended effective January 16, 2006 (33:1 Md. R. 40)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05E amended effective January 16, 2006 (33:1 Md. R. 40)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05F adopted effective January 16, 2006 (33:1 Md. R. 40)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .05F amended effective January 12, 2009 (36:1 Md. R. 25)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .06 amended effective January 16, 2006 (33:1 Md. R. 40)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .07 amended effective January 16, 2006 (33:1 Md. R. 40)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .09C amended effective January 16, 2006 (33:1 Md. R. 40)</annotation>
      <annotation type="History" subtype="Administrative History">Regulation .10A amended effective January 16, 2006 (33:1 Md. R. 40)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.11 repealed and new Regulations .01—.10 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="15" heading="Management of Used Oil">
    <regulation prefix="Regulation" num=".01" heading="Scope.">
      <paragraph num="A.">
        <text>A person managing used oil shall determine using the conditions in COMAR 26.13.10.05 whether the used oil is:</text>
        <paragraph num="(1)">
          <text>Regulated as used oil under this chapter; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Regulated as a hazardous waste under COMAR 26.13.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Notwithstanding §C of this regulation, a person managing used oil shall comply with all of the applicable oil pollution control and storage tank management provisions of COMAR 26.10.01—26.10.13 and 26.10.16—26.10.18.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Exceptions.</text>
        <paragraph num="(1)">
          <text>The management of used oil containing polychlorinated biphenyls (PCBs) at concentrations of 50 parts per million (ppm) or greater is:</text>
          <paragraph num="(a)">
            <text>Regulated as a hazardous waste under 40 CFR Part 761 and COMAR 26.13; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Not regulated as used oil under this chapter.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Materials Mixed with or Derived from Used Oil.</text>
          <paragraph num="(a)">
            <text>A mixture of used oil and diesel fuel mixed on-site by a used oil generator for use in the generator’s own vehicles is not regulated under this chapter once the used oil and diesel fuel have been mixed.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Materials reclaimed from used oil that are beneficially used and not burned as fuel or used in a manner constituting disposal are not regulated as used oil under this chapter.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Wastewater, a discharge of which is subject to §402 or 307(b) of the Clean Water Act, contaminated with “de minimis quantities of used oil” as defined in 40 CFR §279.10(f), is not regulated under this chapter.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Crude Oil Pipeline or Petroleum Refining Facility Process.</text>
          <paragraph num="(a)">
            <text>If used oil introduced into a crude oil pipeline or petroleum refining facility process is exempt from the requirements of 40 CFR Part 279 under the conditions of 40 CFR §279.10(g), then the used oil is not regulated under this chapter.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Notwithstanding the substitution requirement in Regulation .02C(1)(d) of this chapter, a person shall use the used oil specification provided in Table 1 of 40 CFR §279.11 to determine if used oil introduced into a crude oil pipeline or petroleum refining facility process is exempt from the requirements of 40 CFR Part 279 under the conditions of 40 CFR §279.10(g).</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Used Oil on Vessels. Used oil produced on a vessel from normal shipboard operations is not regulated under this chapter until the used oil is transported ashore.</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Used Oil Generators. The following generators of used oil are not subject to the requirements of this chapter:</text>
          <paragraph num="(a)">
            <text>An individual that generates household-derived used oil, such as used oil generated through the maintenance of an individual’s personal vehicle; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A farmer who generates an average of 25 gallons per month or less of used oil from vehicles or machinery used on the farm in a calendar year.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Applicability.</text>
        <paragraph num="(1)">
          <text>The requirements of this chapter and 40 CFR Part 279 apply to:</text>
          <paragraph num="(a)">
            <text>The following used oil management activities:</text>
            <paragraph num="(i)">
              <text>The collection, storage, transportation, processing, re-refining, recycling, or other management of used oil;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The transfer of fuel oil blended or mixed with used oil in the State; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The burning of used oil as fuel;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>A used oil burner that burns off-specification used oil;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A used oil collection center;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>A used oil fuel marketer;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>A used oil generator;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>A used oil processor/re-refiner;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>A used oil transfer facility; and</text>
          </paragraph>
          <paragraph num="(h)">
            <text>A used oil transporter.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The management of used oil mixed with or contaminating another substance is subject to the requirements of this chapter, unless the used oil is:</text>
          <paragraph num="(a)">
            <text>Exempt from being regulated as a used oil under 40 CFR Part 279; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Identified under COMAR 26.13.10.05 as regulated under COMAR 26.13 as a hazardous waste.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Incorporation by Reference.">
      <paragraph num="A.">
        <text>As qualified by §§B and C of this regulation, 40 CFR Part 279 (July 1, 2020) is incorporated by reference.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Interpretation. As provided in Table 1 of this regulation, for the purposes of this chapter, a person shall interpret a cross-reference in 40 CFR Part 279 to a federal regulation in 40 CFR as the analogous State regulation in COMAR Title 26:</text>
      </paragraph>
      <paragraph num="C.">
        <text>Substitutions. For the purposes of this chapter, a person shall make the following substitutions:</text>
        <paragraph num="(1)">
          <text>Substitute a federal provision in 40 CFR Part 279 with a state provision in COMAR Title 26 as follows:</text>
          <paragraph num="(a)">
            <text>For 40 CFR §279.10(b), substitute COMAR 26.13.10.05C—F;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>For 40 CFR §279.10(c), substitute COMAR 26.13.10.05G;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>For 40 CFR §279.10(e), substitute COMAR 26.13.10.05I and 26.13.02.04-1A(15);</text>
          </paragraph>
          <paragraph num="(d)">
            <text>For Table 1 of 40 CFR §279.11, substitute COMAR 26.11.09.10B;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>For 40 CFR §279.57(b), substitute Regulation .06A of this chapter; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>For 40 CFR §§279.22(d), 279.45(h), 279.54(g), and 279.64(g), substitute COMAR 26.10.01.05 and 26.10.08;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Whenever the words “the rebuttable presumption of §279.10(b)(1)(ii)”, “rebuttable presumption provided under §279.10(b)(1)”, or “rebuttable presumption for used oil of §279.10(b)(1)(ii)” appear, substitute with “the rebuttable presumption for used oil of COMAR 26.13.10.05C(2)”;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Substitute the words that appear in 40 CFR §§279.12(b) and 279.82(a) with “The use of used oil as a dust suppressant is prohibited”;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Substitute the words that appear in 40 CFR §§279.42(b), 279.51(b), 279.62(b), and 279.73(b) with “Mechanics of Notification. A used oil transporter, processor/re-refiner, or marketer who does not have an EPA identification number may obtain a number by applying online using the MyRCRAId electronic system, or another equivalent online system, or submitting a completed EPA Form 8700-12 to the Department”;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>In 40 CFR §279.52(b)(6)(viii)(C) and (ix), substitute the words “Regional Administrator” with “Secretary”;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>In 40 CFR §279.66(a)(1), substitute the word “EPA” with “the Department”; and</text>
        </paragraph>
        <paragraph num="(7)">
          <text>In 40 CFR §279.75(a)(1), substitute the word “EPA” with “EPA or the corresponding state agency with regulatory authority over the management of used oil”.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Disposal of Used Oil.">
      <paragraph num="A.">
        <text>This regulation applies to the management of used oil that is not recycled, processed, re-refined, or burned as a fuel.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Use as a Dust Suppressant. A person may not use used oil as a dust suppressant.</text>
      </paragraph>
      <paragraph num="C.">
        <text>Disposal of Hazardous Used Oil. The disposal of used oil identified as a hazardous waste is subject to the hazardous waste management requirements in COMAR 26.13.</text>
      </paragraph>
      <paragraph num="D.">
        <text>Disposal of Used Oil.</text>
        <paragraph num="(1)">
          <text>Except as provided under Environment Article, Title 7, Subtitle 2, Annotated Code of Maryland or any other provisions of law, a person may not dispose of, or cause to be disposed of, used oil by:</text>
          <paragraph num="(a)">
            <text>Discharging, dumping, or depositing the used oil into sewers, drainage systems, surface waters or groundwaters, and any waters of the State;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Incinerating used oil as refuse, not including the burning of used oil as fuel in accordance with this chapter; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Disposing, dumping, or depositing used oil onto public or private land that is not an approved facility, as provided under §D(2) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A person may dispose of used oil at one of the following approved facilities:</text>
          <paragraph num="(a)">
            <text>Pursuant to Environment Article, §5-1001, Annotated Code of Maryland, public or private land designated by the State or an agency or political subdivision of the State as a collection facility for used oil in which used oil is placed in a receptacle or container installed or located on the property; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A solid waste acceptance facility permitted under COMAR 26.04.07 as specifically authorized by the Department to handle used oil or waste containing free phase used oil.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Management of Used Oil.">
      <paragraph num="A.">
        <text>General Provisions.</text>
        <paragraph num="(1)">
          <text>Spill, Release, or Discharge.</text>
          <paragraph num="(a)">
            <text>A person shall report a spill, release, or discharge of used oil to the Department immediately, but not later than 2 hours, after detection of the spill, release, or discharge in accordance with COMAR 26.10.01.05 and 26.10.08.01.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In response to a confirmed spill, release, or discharge of used oil or an oil-derived product from a storage tank system, an owner and an operator of the storage tank system and any responsible party shall comply with the response and corrective action requirements of COMAR 26.10.09.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>A person transporting used oil in a truck previously used to transport hazardous waste shall comply with the transportation of hazardous waste requirements in COMAR 26.13.04.01D(4).</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Burning Used Oil.</text>
        <paragraph num="(1)">
          <text>A person that proposes to burn used oil in fuel-burning equipment shall submit to the Department the information required in COMAR 26.11.09.10A.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A person burning used oil as fuel shall comply with:</text>
          <paragraph num="(a)">
            <text>Regulation .05B of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>COMAR 26.11.09.10;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>If burning on-specification used oil as fuel, 40 CFR §279.23; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>If burning off-specification used oil as fuel, 40 CFR §§257.12(c) and 257.60—257.66.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Storage of Used Oil. A person managing used oil shall only store used oil in a storage unit that meets one of the following criteria:</text>
        <paragraph num="(1)">
          <text>A storage tank system that complies with COMAR 26.10.01—26.10.12 and 26.10.16—26.10.18; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Depending upon the type of facility where the used oil is stored, a container equipped with a containment system that meets the applicable requirements in 40 CFR §279.22, 279.54, or 279.64.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Department Approvals and Registrations. An owner, an operator, and a person in charge of an oil handling facility or oil storage facility that manages used oil shall comply with the following Department approval and registration requirements:</text>
        <paragraph num="(1)">
          <text>If the facility has a used oil aboveground aggregate storage capacity of 1,000 gallons or greater, obtain an Individual Oil Operations Permit from the Department in accordance with COMAR 26.10.01.09A and .11;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If the facility has a used oil aboveground aggregate storage capacity of less than 1,000 gallons, comply with the General Oil Operations Permit conditions in COMAR 26.10.01.09B;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If used oil is stored in a petroleum UST system, register each UST system at the facility with the Department in accordance with COMAR 26.10.03.09;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>If used oil is stored in an AST system, register each AST system at the facility with the Department in accordance with COMAR 26.10.01.10;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>If transferring fuel oil blended or mixed with processed or re-refined used oil in the State, obtain an Oil Transfer License from the Department in accordance with COMAR 26.10.01.08;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>If a used oil transporter, used oil processor/re-refiner, or used oil marketer, obtain an EPA identification number by:</text>
          <paragraph num="(a)">
            <text>Applying for an EPA identification number online using the MyRCRAId electronic system or another equivalent online system; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Submitting a completed EPA Form 8700-12 to the Department;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>If burning used oil as fuel, comply with the fuel-burning equipment registration or air quality permitting requirements in COMAR 26.11.02.02; and</text>
        </paragraph>
        <paragraph num="(8)">
          <text>If applicable, obtain a State discharge permit or National Pollutant Discharge Elimination System permit from the Department in accordance with COMAR 26.08.04.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>An owner, an operator, and a person in charge of a used oil processor/re-refiner facility shall:</text>
        <paragraph num="(1)">
          <text>Comply with the general facility standards for preparedness and prevention, prepare a contingency plan, and implement emergency procedures in accordance with 40 CFR §279.52; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In accordance with 40 CFR §279.55, develop, follow, and keep at the facility a written analysis plan used to determine:</text>
          <paragraph num="(a)">
            <text>The total halogen content of used oil in accordance with Regulation .05A of this chapter; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If the used oil is to be burned as fuel, whether the used oil meets the specifications in COMAR 26.11.10.09B in accordance with Regulation .05B of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Analytical Requirements.">
      <paragraph num="A.">
        <text>Rebuttable Presumption for Used Oil.</text>
        <paragraph num="(1)">
          <text>Used oil containing more than 1,000 ppm total halogens is presumed to be hazardous waste because it has been mixed with halogenated hazardous waste listed in COMAR 26.13.02.16—.19, unless a person rebuts this presumption by demonstrating the used oil does not contain hazardous waste, as specified in COMAR 26.13.02.04-1A(11).</text>
        </paragraph>
        <paragraph num="(2)">
          <text>To determine whether used oil is presumed to be hazardous waste under the rebuttable presumption, a person managing used oil shall determine the total halogen content of the used oil in accordance with COMAR 26.13.10.05C(2) and, depending on the type of facility managing the used oil, the applicable requirements in 40 CFR §279.44, 279.53, or 279.63.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Specifications for Used Oil Burned as Fuel. A person that burns used oil as fuel or processes used oil to produce a heating oil shall determine if the used oil or used oil-derived heating oil meets or exceeds the specifications for used oil in COMAR 26.11.09.10B by performing analyses or obtaining documentation demonstrating the used oil or used oil-derived heating oil meets or exceeds the specifications.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Recordkeeping and Reports.">
      <paragraph num="A.">
        <text>On a form provided by the Department, a used oil transporter or used oil processor/re-refiner shall:</text>
        <paragraph num="(1)">
          <text>Report on used oil operations conducted during the preceding fiscal year, covering the 12-month period from July 1 to June 30;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Include in the report all of the following information:</text>
          <paragraph num="(a)">
            <text>The name and address of the used oil transporter or used oil processor/re-refiner;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If a used oil processor/re-refiner, the facility’s EPA identification number;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The quantity of used oil collected in the State;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The quantity of used oil exported out of the State;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The quantity of used oil imported into the State;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>The methods in which used oil was managed or disposed, including burning used oil as fuel; and</text>
          </paragraph>
          <paragraph num="(g)">
            <text>The quantity of used oil managed or disposed using each method; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Submit the report to the Department not later than July 31, following the reporting period.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Operating Record. An owner and an operator of a used oil processor/re-refiner shall maintain and keep a written operating record at the facility in accordance with 40 CFR §257.57.</text>
      </paragraph>
      <paragraph num="C.">
        <text>A used oil transporter and an owner, an operator, and a person in charge of a used oil transfer, processor/re-refiner, burner, or fuel marketer facility shall comply with the applicable tracking, notice, recordkeeping, and record retention requirements in 40 CFR §§279.44, 279.46, 279.56, 279.63, 279.66, 279.72(b), 279.74, and 279.75.</text>
      </paragraph>
      <paragraph num="D.">
        <text>A person that burns used oil in fuel-burning equipment shall comply with the annual reporting requirement in COMAR 26.11.09.10D.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Closure Requirements.">
      <paragraph num="A.">
        <text>Upon the termination of used oil operations, an owner, an operator, and a person in charge of an oil handling or oil storage facility that collects, stores, transports, transfers, processes, re-refines, recycles, burns as fuel, or otherwise manages used oil shall comply with the closure requirements of this regulation.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Facility Closure. An owner, an operator, and a person in charge an oil handling or oil storage facility described in §A of this regulation shall:</text>
        <paragraph num="(1)">
          <text>Remove or decontaminate used oil residues in storage tank systems, containers and contaminated secondary containment system components and used oil-contaminated soils, structures and equipment;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Unless determined to be nonhazardous waste under COMAR 26.13.02.15—.19 or COMAR 26.13.10.05, manage used oil residuals or used oil-contaminated material as hazardous waste; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If the owner, the operator, and the person in charge of the facility demonstrates not all contaminated soils can be practicably removed or decontaminated as required in §B(1) of this regulation, close the storage tank system and perform post-closure care at the facility in accordance with the requirements for a hazardous waste landfill in COMAR 26.13.06.22B(3).</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Underground Storage Tanks. An owner, an operator, and a person in charge of an oil handling or oil storage facility storing used oil in a UST shall comply with the temporary or permanent closure requirements in COMAR 26.10.10.</text>
      </paragraph>
      <paragraph num="D.">
        <text>Aboveground Storage Tanks. An owner, an operator, and a person in charge of an oil handling or oil storage facility storing used oil in an AST shall comply with the temporary or permanent closure requirements in COMAR 26.10.17 or 26.10.18.</text>
      </paragraph>
      <paragraph num="E.">
        <text>Containers. An owner, an operator, and a person in charge of an oil handling or oil storage facility storing used oil in containers shall:</text>
        <paragraph num="(1)">
          <text>Remove used oil residues from containers;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Remove containers that stored used oil and any used oil residues from the site; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Unless determined to be nonhazardous waste under COMAR 26.13.02.15—.19 or COMAR 26.13.10.05, manage the materials as hazardous waste.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>An owner, an operator, and a person in charge of an oil handling or oil storage facility conducting a removal or decontamination processes in accordance with this regulation that generates air emissions shall meet all applicable air quality requirements in COMAR 26.11.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-402, 4-405, and 4-410, Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: September 7, 1998 (25:18 Md. R. 1438)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.06 repealed and new Regulations .01—.07 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="16" heading="Trained Facility Operators">
    <regulation prefix="Regulation" num=".01" heading="Scope.">
      <paragraph num="A.">
        <text>This chapter applies to an owner and an operator of a UST system or group of UST systems located at a regulated substance storage facility.</text>
      </paragraph>
      <paragraph num="B.">
        <text>This chapter establishes the Class A operator, the Class B operator, and the Class C operator classifications, and the required knowledge, duties, skills, training requirements, and certification requirements for each operator classification.</text>
      </paragraph>
      <paragraph num="C.">
        <text>This chapter:</text>
        <paragraph num="(1)">
          <text>Does not apply to an owner and an operator of a UST system that stores only heating oil for consumptive use;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Does not alter the definition of an operator set forth in COMAR 26.10.01.02B;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Does not apply to an individual defined as an operator under COMAR 26.10.01.02B, unless an owner and an operator of a UST system or group of UST systems located at a regulated substance storage facility designates that individual to serve as the Class A operator, the Class B operator, or the Class C operator for the UST system or group of UST systems at the regulated substance storage facility;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Does not relieve an owner and an operator of a UST system of the duty to comply with the legal responsibilities under:</text>
          <paragraph num="(a)">
            <text>40 CFR Part 280;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Environment Article, Title 4, Annotated Code of Maryland;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Environment Article, Title 7, Annotated Code of Maryland; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>COMAR 26.10.01—26.10.12; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Does not alter or transfer the legal responsibilities for, between, or among an owner and an operator of a UST system under:</text>
          <paragraph num="(a)">
            <text>40 CFR Part 280;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Environment Article, Title 4, Annotated Code of Maryland;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Environment Article, Title 7, Annotated Code of Maryland; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>COMAR 26.10.01—26.10.12.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Definitions.">
      <paragraph num="A.">
        <text>In this chapter:</text>
        <paragraph num="(1)">
          <text>A term in §B of this regulation has the meaning indicated; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A term not defined in §B of this regulation has:</text>
          <paragraph num="(a)">
            <text>The meaning given to the term in a relevant statute or COMAR 26.10.01 or 26.10.02; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If not defined in a relevant statute or COMAR 26.10.01 or 26.10.02, the meaning attributed by common use.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>“Class A operator” means an individual who:</text>
          <paragraph num="(a)">
            <text>Has primary responsibility to operate and maintain a UST system in accordance with applicable requirements established by the Department; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Typically manages resources and personnel, such as establishing work assignments, to achieve and maintain compliance with regulatory requirements.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>“Class B operator” means an individual who:</text>
          <paragraph num="(a)">
            <text>Has day-to-day responsibility for implementing applicable regulatory requirements for a UST system established by the Department; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Typically implements in-field aspects of operation, maintenance, and associated recordkeeping for a UST system.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>“Class C operator” means an individual who:</text>
          <paragraph num="(a)">
            <text>Is responsible for initially addressing emergencies presented by a spill, release, or discharge from a UST system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Typically controls or monitors the dispensing or sale of regulated substances.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>“Training Program” means an informational course, class, or set of training instructions approved by the Department for educating and certifying a Class A operator, Class B operator, or Class C operator to comply with this chapter.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="Implementation.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system or group of UST systems shall:</text>
        <paragraph num="(1)">
          <text>Designate by a written list one or more individuals to serve as a Class A operator, a Class B operator, and a Class C operator for a UST system or group of UST systems at a regulated substance storage facility;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Ensure that Class A operators, Class B operators, and Class C operators designated under §A(1) of this regulation are trained and certified in accordance with this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Provide written instructions for the UST system or group of UST systems at the regulated substance storage facility that are readily accessible at all times to the Class A operators, the Class B operators, and the Class C operators identified under §A(1) of this regulation and that describe how to:</text>
          <paragraph num="(a)">
            <text>Respond to operational or equipment alarms, warnings, or alert mechanisms;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Implement the emergency shutoff process;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Respond to a suspected or confirmed spill, release or discharge, unusual operating conditions, emergencies, and equipment failures; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Notify the Department of a spill, release, or discharge in accordance with:</text>
            <paragraph num="(i)">
              <text>Environment Article, §4-410, Annotated Code of Maryland;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>COMAR 26.10.01.05; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>COMAR 26.10.08.01—.04;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Provide emergency telephone numbers for contacting emergency response authorities, persons responsible for the regulated substance storage facility, and the Department in the event of a suspected or confirmed spill, release or discharge, unusual operating conditions, an emergency, or an equipment failure;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Except for an approved unattended motor fuel dispensing facility, ensure that the emergency telephone numbers provided under §A(4) of this regulation are readily accessible on-site to the Class A operators, the Class B operators, and the Class C operators and other facility personnel; and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>For an approved unattended motor fuel dispensing facility, ensure that the emergency telephone numbers provided under §A(4) of this regulation are conspicuously posted on a sign as required by COMAR 26.10.01.20E.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner and an operator of a UST system or a group of UST systems at a regulated substance storage facility may not:</text>
        <paragraph num="(1)">
          <text>Dispense from or store in a UST system a regulated substance unless the Class A operators, the Class B operators, and the Class C operators have been designated, trained, and certified as required by this chapter; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Except for an approved unattended motor fuel dispensing facility, dispense a regulated substance from a UST system unless at least one Class A operator, Class B operator, or Class C operator is present at the regulated substance storage facility.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of a UST system or group of UST systems at a regulated substance storage facility shall ensure that:</text>
        <paragraph num="(1)">
          <text>A regulated substance storage facility continuously has one or more individuals designated, trained, and certified to serve as a Class A operator, a Class B operator, and a Class C operator as required by this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>New or replacement Class A operators and Class B operators are trained and certified within 30 days after assuming duties and responsibilities of the designated class;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>New or replacement Class C operators are trained and certified before assuming duties and responsibilities of the class; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The following documents are updated within 10 business days of a change:</text>
          <paragraph num="(a)">
            <text>The written list set forth in §A(1) of this regulation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The written instructions set forth in §A(3) of this regulation; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The emergency telephone numbers set forth in §A(4) of this regulation.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>An owner and an operator of a UST system or group of UST systems at an approved unattended motor fuel dispensing facility shall ensure that:</text>
        <paragraph num="(1)">
          <text>A Class A operator, a Class B operator, or a Class C operator inspects the regulated substance storage facility for suspected or confirmed spills, releases or discharges, unusual operating conditions, emergencies, and equipment failures monthly or at another frequency approved by the Department; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A written record of inspections required in §D(1) of this regulation are maintained by the owner and the operator of the UST system or group of UST systems and made available upon request by the Department or a UST system inspector certified by the Department under COMAR 26.10.06.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Requirements for Designated Operators.">
      <paragraph num="A.">
        <text>A Class A operator shall:</text>
        <paragraph num="(1)">
          <text>Successfully complete Class A operator training required by this chapter and approved by the Department;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In accordance with this chapter and COMAR 26.10.01—26.10.12, ensure that:</text>
          <paragraph num="(a)">
            <text>The installation, upgrade, and repair of a UST system is performed in the continuous on-site presence and under the direction of a UST system technician certified under COMAR 26.10.06;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The closure or a change-in-service of a UST system is performed in the continuous on-site presence and direction of a UST system technician or remover certified under COMAR 26.10.06;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A qualified person implements the operation, maintenance, testing, and recordkeeping requirements for a UST system, including requirements related to:</text>
            <paragraph num="(i)">
              <text>Spill and overfill prevention;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Release detection, reporting, and emergency response;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Corrosion protection;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Product and equipment compatibility;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Financial responsibility;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Notification and UST system registration;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>The temporary and permanent closure and change-in-service of a UST system; and</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>Class B operator and Class C operator training and certification; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(d)">
            <text>Records required to demonstrate compliance with COMAR 26.10.01—26.10.12 are maintained and made available upon request to the Department or a certified UST system inspector;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Maintain knowledge of the skills and training requirements for Class B operators and Class C operators; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Be available to respond to suspected or confirmed spills, releases or discharges, unusual operating conditions, emergencies, and equipment failures at a regulated substance storage facility by being:</text>
          <paragraph num="(a)">
            <text>Immediately accessible for consultation by telephone when the facility is operating; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>On-site at the regulated substance storage facility within 24 hours of receiving a request from emergency response personnel or the Department, or within another time period approved by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>A Class B operator shall:</text>
        <paragraph num="(1)">
          <text>Successfully complete Class B operator training required by this chapter and approved by the Department;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>In accordance with this chapter and COMAR 26.10.01—26.10.12, ensure that:</text>
          <paragraph num="(a)">
            <text>UST system release detection methods are implemented, and release detection and prevention equipment are operational and tested;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Release detection reporting requirements are met;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The inspection and testing of spill prevention, overfill prevention, and corrosion protection equipment for proper operation are conducted;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Walkthrough inspections are conducted;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>All required UST system equipment tests are conducted;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>UST equipment manufacturer and third-party performance standards are met, and the applicable standards, manuals, and instructions are available at a regulated substance storage facility;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Records required to demonstrate compliance with COMAR 26.10.01—26.10.12 are maintained and made available upon request to the Department or a certified UST system inspector; and</text>
          </paragraph>
          <paragraph num="(h)">
            <text>A Class C operator is trained in accordance with this chapter to respond properly to a suspected or confirmed spills, releases or discharges, unusual operating conditions, emergencies, and equipment failures;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Maintain knowledge of the skills and training requirements for a Class C operator; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Be available to respond to a suspected or confirmed spills, releases or discharges, unusual operating conditions, emergencies, and equipment failures at a regulated substance storage facility by being:</text>
          <paragraph num="(a)">
            <text>Immediately accessible for consultation by telephone when the facility is operating; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>On-site at the regulated substance storage facility within 24 hours of a receiving request from emergency response personnel or the Department, or within another time period approved by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>A Class C operator shall:</text>
        <paragraph num="(1)">
          <text>Successfully complete the Class C operator training required by this chapter and approved by the Department; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Control and monitor the dispensing or sale of a regulated substance;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Immediately respond to alarms, equipment failures, or other indications of emergencies caused by a spill, release, or discharge from the UST system;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Notify a Class A operator or a Class B operator, appropriate emergency response personnel, and the Department of a suspected or confirmed spill, release, or discharge in accordance with the written instructions provided by the owner and the operator of the UST system as set forth in Regulation .03A(3) of this chapter; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Be available to respond to suspected or confirmed spills, releases or discharges, unusual operating conditions, emergencies, and equipment failures at a regulated substance storage facility by:</text>
          <paragraph num="(a)">
            <text>Except for an approved unattended motor fuel dispensing facility, being on-site and readily available whenever the regulated substance storage facility is operating; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>For an approved unattended motor fuel dispensing facility:</text>
            <paragraph num="(i)">
              <text>Being immediately accessible for consultation by telephone with emergency response personnel or the Department; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Being on-site at the regulated substance storage facility within 2 hours of receiving a request from emergency response personnel or the Department, or within another time period approved by the Department.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Requirements for Operator Training.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system or a group of UST systems shall ensure each individual designated as Class A operator, Class B operator, and a Class C operator for a regulated substance storage facility is trained in accordance with the requirements of this regulation.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An individual designated for more than one operator class shall successfully complete the required training program for each operator class in which the individual is designated.</text>
      </paragraph>
      <paragraph num="C.">
        <text>An owner and an operator of a UST system or a group of UST systems shall:</text>
        <paragraph num="(1)">
          <text>Ensure any training program meets the minimum training requirements of this regulation for each operator class; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Include an evaluation through testing, a practical demonstration, or another approach approved by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Class A Operators.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system or a group of UST systems shall provide a Class A operator training program that meets the requirements in §D(2) and (3) of this regulation.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At a minimum, the training program for a Class A operator provides general knowledge and teaches a Class A operator about the purpose, methods, and functions of:</text>
          <paragraph num="(a)">
            <text>Spill and overfill prevention;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Release detection;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Corrosion protection;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Emergency response;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Product and equipment compatibility and demonstration of compatibility;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Financial responsibility;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Notification and UST system registration;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>The temporary and permanent closure and change-in-service of a UST system;</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Reporting, recordkeeping, testing, and inspections;</text>
          </paragraph>
          <paragraph num="(j)">
            <text>Environmental and regulatory consequences of releases; and</text>
          </paragraph>
          <paragraph num="(k)">
            <text>Training requirements for Class B operators and Class C operators.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>At a minimum, the training program evaluates a Class A operator to determine if the individual has the knowledge and skills in accordance with §D(2) of this regulation to:</text>
          <paragraph num="(a)">
            <text>Make informed decisions regarding regulatory compliance; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Determine whether appropriate individuals are fulfilling the operation, maintenance, testing, and recordkeeping requirements for UST systems.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Class B Operators.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system or group of UST systems shall provide a Class B operator training program that meets the requirements in §E(2)—(4) of this regulation.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At a minimum, the training program for a Class B operator covers either:</text>
          <paragraph num="(a)">
            <text>General requirements that encompass all regulatory requirements and typical equipment used at a regulated substance storage facility; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Site-specific requirements that address only the regulatory requirements and equipment specific to a regulated substance storage facility for which the Class B operator has been designated.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>At a minimum, the training program for a Class B operator teaches the Class B operator about the purpose, methods, and functions of:</text>
          <paragraph num="(a)">
            <text>Operation and maintenance;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Spill and overfill prevention;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Release detection and related reporting;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Corrosion protection;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Emergency response;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Product and equipment compatibility and demonstration of compatibility;</text>
          </paragraph>
          <paragraph num="(g)">
            <text>Reporting, recordkeeping, testing, and inspections;</text>
          </paragraph>
          <paragraph num="(h)">
            <text>Environmental and regulatory consequences of releases; and</text>
          </paragraph>
          <paragraph num="(i)">
            <text>Training requirements for Class C operators.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>At a minimum, the training program evaluates a Class B operator to determine if the individual has the knowledge and skills in accordance with §E(2) and (3) of this regulation to implement applicable UST regulatory requirements in the field on:</text>
          <paragraph num="(a)">
            <text>The components of a typical UST system; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The site-specific equipment used at a regulated substance storage facility for which the Class B operator has been designated.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>Class C Operators.</text>
        <paragraph num="(1)">
          <text>An owner and an operator of a UST system shall provide a Class C operator training program that meets the requirements in §F(2)—(5) of this regulation and Regulation .07D of this chapter.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A certified Class A operator or a certified Class B operator designated for a regulated substance storage facility shall train each individual designated as a Class C operator for the same regulated substance storage facility.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>At a minimum, the training program for a Class C operator teaches the Class C operator to take appropriate action, including notifying appropriate authorities, in response to emergencies or alarms caused by spills, releases, and discharges resulting from the operation of a UST system.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The training program for a Class C operator is specific to a regulated substance storage facility for which the individual has been designated, and the training program is not valid for another regulated substance storage facility.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>At a minimum, the training program evaluates a Class C operator to determine if the individual has the knowledge and skills in accordance with §F(3) and (4) of this regulation to take appropriate action, including notifying appropriate authorities, in response to emergencies or alarms caused by spills, releases, and discharges from a UST system.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Training Programs.">
      <paragraph num="A.">
        <text>The Department shall:</text>
        <paragraph num="(1)">
          <text>Review and approve training programs for Class A operators, Class B operators, and Class C operators; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Make available a list of approved training programs.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The Department may not approve a training program if:</text>
        <paragraph num="(1)">
          <text>A person intending to implement a training program has demonstrated a history of noncompliance with the requirements of COMAR 26.10;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The training program does not meet the minimum requirements established in Regulation .05 of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Department-required changes to training materials are not made; or</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The person implementing the training program has not demonstrated a process to keep records in accordance with this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>A person implementing a training program shall:</text>
        <paragraph num="(1)">
          <text>Obtain approval for a training program in writing from the Department by;</text>
          <paragraph num="(a)">
            <text>Ensuring the training program meets the minimum requirements established in Regulation .05 of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Ensuring the certification requirements in Regulation .07A and B of this chapter are met;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Submitting training program materials, including a program outline, presentation materials, and testing materials to the Department for review;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Making any changes required by the Department; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Demonstrating that the recordkeeping requirements of this regulation will be met;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Provide operator training in accordance with a Department-approved training program;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Obtain approval for a change to an approved training program in writing from the Department;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Provide a dated certificate to each trainee that successfully completes a training program;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Maintain the following training records:</text>
          <paragraph num="(a)">
            <text>Date and location of training;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Names of trainers providing training;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Names of trainees in attendance;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Names of trainees certified as Class A operators, Class B operators, and Class C operators; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>A copy of the dated certificate required in §C(4) of this regulation;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>Make records available upon request by the Department or a UST system inspector certified under COMAR 26.10.06; and</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Allow the Department to audit a training program.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Reauthorization of Currently Approved Training Programs.</text>
        <paragraph num="(1)">
          <text>Upon the effectiveness of a new or revised regulation under this chapter or COMAR 26.10.01—26.10.12, the Department shall provide notice to a person implementing a currently approved training program that the person is required to update an approved training program.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Upon receiving notice from the Department, a person shall revise a currently approved training program and submit the revised training program materials to the Department for approval.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A person may not implement an updated training program that has not been approved by the Department.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Certification.">
      <paragraph num="A.">
        <text>An owner and an operator of a UST system or a group of UST systems at a regulated substance storage facility shall have:</text>
        <paragraph num="(1)">
          <text>An individual designated to be a Class A operator or a Class B operator, or both, successfully complete a training program in accordance with §B or C of this regulation; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An individual designated to be a Class C operator successfully complete a training program in accordance with §D of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>The Department shall consider an individual to have successfully completed a Class A operator or a Class B operator training program if the following requirements are met:</text>
        <paragraph num="(1)">
          <text>An individual designated as a Class A operator was trained and evaluated in accordance with Regulation .05D of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An individual designated as a Class B operator was trained and evaluated in accordance with Regulation .05E of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An individual attended 100 percent of the training program;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>An individual achieved a score of 80 percent or better on a written competency test of the information presented; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>The trainer provided a dated certificate to an individual that successfully completed the training.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>With approval from the Department, an owner and an operator of a UST system or a group of UST systems at a regulated substance storage facility may conduct a training program at the regulated substance storage facility for an individual designated to serve as the Class A operator or the Class B operator, or both, at the facility provided the following requirements are met:</text>
        <paragraph num="(1)">
          <text>An individual designated as a Class A operator is trained and evaluated in accordance with Regulation .05D of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An individual designated as a Class B operator is trained and evaluated in accordance with Regulation .05E of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An individual demonstrates to the satisfaction of the trainer:</text>
          <paragraph num="(a)">
            <text>For a Class A operator, the individual has the knowledge and skills in accordance with Regulation .05D(2) of this chapter to:</text>
            <paragraph num="(i)">
              <text>Make informed decisions regarding regulatory compliance for a UST system at the regulated substance storage facility; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Determine whether appropriate individuals are fulfilling the operation, maintenance, testing, and recordkeeping requirements for a UST system at the regulated substance storage facility;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>For a Class B operator, that the individual has the knowledge and skills in accordance with Regulation .05E(2) and (3) of this chapter to implement applicable UST system regulatory requirements for the site-specific equipment used at the facility; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>The trainer provides a dated certificate to an individual that successfully completes the on-site training.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>A certified Class A operator or a certified Class B operator designated for a regulated substance storage facility shall train and certify an individual to be a Class C operator for that regulated substance storage facility by:</text>
        <paragraph num="(1)">
          <text>Training and evaluating the individual in accordance with Regulation .05F of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Having the individual demonstrate an understanding of the written instructions required by Regulation .03A(3) of this chapter; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Upon successful completion of the training, completing and signing a form provided by the Department that certifies the Class C operator has been successfully trained.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>In addition to §D of this regulation, an owner and an operator of a UST system or group of UST systems at a regulated substance storage facility may provide an off-site or on-site training program to an individual designated to serve as a Class C operator.</text>
      </paragraph>
      <paragraph num="F.">
        <text>Reciprocity.</text>
        <paragraph num="(1)">
          <text>The Department may allow a Class A operator or a Class B operator certification from another state to satisfy the requirements of this chapter.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>An individual certified as a Class A operator or a Class B operator in another state shall request reciprocity as a Class A operator or a Class B operator on a form provided by the Department.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>An individual requesting reciprocity shall demonstrate to the satisfaction of the Department that the operator training requirements and the UST system regulations where the individual is presently certified are at least as stringent as this chapter and COMAR 26.10.01—26.10.12.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Sanctions.">
      <paragraph num="A.">
        <text>Retraining.</text>
        <paragraph num="(1)">
          <text>If the Department determines that a Class A operator or a Class B operator is not in compliance with a regulation in this chapter, or that a regulated substance storage facility is not in compliance with any regulations in COMAR 26.10.01—26.10.12, the Department shall document the deficiency.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Upon notice of a documented deficiency provided under §A(1) of this regulation, the owner and the operator of the UST system and regulated substance storage facility shall implement one or more of the following options as directed by the Department for the designated Class A operator or Class B operator, or both:</text>
          <paragraph num="(a)">
            <text>Have the Class A operator or the Class B operator complete a full training program and meet the certification requirements of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Have the Class A operator or the Class B operator complete a training program tailored to the areas the Department determined were deficient and demonstrate the duties, skills, and knowledge areas in compliance with the requirements of this chapter or in a manner specified by the Department; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Have the Class A operator or the Class B operator complete partial on-site training given by a Department representative in the areas the Department determined were deficient and demonstrate the duties, skills, and knowledge areas to the satisfaction of the Department representative.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>In providing a notice under §A(2) of this regulation, the Department may require a Class A operator or a Class B operator, or both, receive training from an alternate training program rather than the training program in which the operator originally or most recently received training from.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Not later than 30 days after receiving a notice from the Department under §A(2) of this regulation, an owner and an operator of a UST system shall ensure that a Class A operator or a Class B operator, or both, completes the retraining required by the Department, unless the Department waives the retraining requirement for either the Class A operator or the Class B operator, or both.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Within 60 days of the Department’s directive to retrain a Class A operator or a Class B operator, or both, an owner and an operator of a UST system shall submit written verification to the Department that retraining was completed.</text>
        </paragraph>
        <paragraph num="(6)">
          <text>In addition to the retaining requirements in §A(1)—(5) of this regulation, the Department may require an owner and an operator of a UST system and a regulated substance storage facility to retrain designated Class C operators.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Training Programs. The Department may suspend or revoke its approval of a training program if the Department determines that a person implementing a training program or a trainer for the training program has done one or more of the following:</text>
        <paragraph num="(1)">
          <text>Demonstrated a willful or negligent disregard or repeated violations of the regulations in COMAR 26.10; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Willfully or negligently submitted false information to the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>A person violating a provision of this chapter is subject to sanctions under:</text>
        <paragraph num="(1)">
          <text>Environment Article, Title 4, Subtitle 4, Annotated Code of Maryland;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Environment Article, Title 7, Subtitle 2, Part VIII, Annotated Code of Maryland; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Any other sanctions provided by federal or State statutes or regulations.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".09" heading="Recordkeeping.">
      <text>An owner and an operator of a UST system or a group of UST systems at a regulated substance storage facility shall:</text>
      <paragraph num="A.">
        <text>Maintain records in accordance with COMAR 26.10.04.05 that demonstrate compliance with this chapter;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Maintain the following records:</text>
        <paragraph num="(1)">
          <text>A list of certified Class A operators, Class B operators, and Class C operators designated for a regulated substance storage facility by the owner and the operator as required by Regulation .03A(1) of this chapter that:</text>
          <paragraph num="(a)">
            <text>Identifies all Class A operators, Class B operators, and Class C operators currently designated for the facility; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Includes for each currently designated operator:</text>
            <paragraph num="(i)">
              <text>The operator’s name, mailing address, and emergency contact number;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The date the operator assumed duties for the operator class at the facility; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The name of the initial training program and any required retraining programs and the date of completion for each training program;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Paper or electronic records verifying the completion of a training or a retraining program for each currently designated Class A operator, Class B operator, and Class C operator that:</text>
          <paragraph num="(a)">
            <text>Identifies the name of the trainee, the date trained, and the name of the operator training class that was completed;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Lists the name of the trainer and the training company name, address, and telephone number; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Includes a copy of the training certificate issued to the operator;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Written verification from the Class A operator or the Class B operator that designates a Class C operator demonstrating the Class C operator’s understanding of the written instructions required by Regulation .03A(3) of this chapter; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Copies of the inspection records required in Regulation .03D(2) of this chapter;</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Ensure compliance with the following training record requirements:</text>
        <paragraph num="(1)">
          <text>A trainer shall sign records from classroom or field training programs, including Class C operator training provided by a Class A operator or a Class B operator;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Records from computer-based training programs, at a minimum, indicate the name of the training program and the web address; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Records of retraining include those areas on which the Class A operator or the Class B operator, or both, were retrained;</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Keep the records required by §B of this regulation at a location designated by the owner for the following durations:</text>
        <paragraph num="(1)">
          <text>Records required by §B(1)—(3) of this regulation for as long as a Class A operator, Class B operator, and Class C operator is designated; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Records required by §B(4) of this regulation for 5 years; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Ensure the records required to be maintained under this chapter are available upon request by the Department or a UST system inspector certified by the Department under COMAR 26.10.06.</text>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401, 4-402, 4-405, 4-408&lt;MA&gt;4-411.1, 4-412, 4-415-1—4-419, and 7-201 et seq., Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: April 19, 2010 (37:8 Md. R. 621)</annotation>
      <annotation type="History" subtype="Administrative History">Regulations .01—.08 repealed and new Regulations .01—.09 adopted effective June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="17" heading="Shop-Fabricated Aboveground Storage Tanks">
    <regulation prefix="Regulation" num=".01" heading="Scope.">
      <paragraph num="A.">
        <text>This chapter applies to an owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that is used or may be used to store oil at an oil storage facility or oil handling facility.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system subject to the requirements in this chapter shall meet all applicable requirements under COMAR 26.10.01 for an oil storage facility or oil handling facility.</text>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST used for storing asphalt only is exempt from the following requirements of this chapter:</text>
        <paragraph num="(1)">
          <text>Unless otherwise directed by the Department, the secondary containment requirements in Regulation .07 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The spill and overfill prevention requirements in Regulation .08 of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The release detection requirements in Regulation .09 of this chapter; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>The emergency venting requirement in Regulation .11B of this chapter if the AST system has a capacity greater than 12,000 gallons and is not located in:</text>
          <paragraph num="(a)">
            <text>A secondary containment dike with another AST system storing a Class I liquid or Class II liquid; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The drainage path of another AST system storing a Class I liquid or Class II liquid.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Definitions.">
      <paragraph num="A.">
        <text>In this chapter:</text>
        <paragraph num="(1)">
          <text>A term in §B of this regulation has the meaning indicated; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A term not defined in §B of this regulation has:</text>
          <paragraph num="(a)">
            <text>The meaning given to the term in a relevant statute or COMAR 26.10.01 or 26.10.02; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If not defined in a relevant statute or COMAR 26.10.01 or 26.10.02, the meaning attributed by common use.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>“AST” has the meaning stated in COMAR 26.10.01.02B.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>“AST system” has the meaning stated in COMAR 26.10.01.02B.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>“Certified inspector” includes one of the following individuals certified to perform an inspection on a shop-fabricated AST:</text>
          <paragraph num="(a)">
            <text>An authorized inspector, as defined in COMAR 26.10.18.02B, with an adjunct certification, as specified in STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A certified AST tank system inspector, as specified in STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>“Double-walled AST” means an AST that:</text>
          <paragraph num="(a)">
            <text>Is manufactured as a storage tank within a storage tank; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Has an interstitial space between the primary storage tank and secondary storage tank walls that allows for:</text>
            <paragraph num="(i)">
              <text>Tightness testing of both storage tank walls; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Monitoring of the interstitial space for a release from the primary storage tank.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>“Elevated AST” means an AST that is not in direct contact with soil by either:</text>
          <paragraph num="(a)">
            <text>Being raised above the surface of the ground or bottom of a vault using supports designed to secure and support the AST from collapse when containing oil; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Resting on a surface material that does not allow moisture penetration or corrosion, such as concrete or steel.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>“Existing” means the installation or construction of an AST, an AST system, or a secondary containment dike was complete before June 13, 2022.</text>
        </paragraph>
        <paragraph num="(7)">
          <text>“External inspection” means a formal inspection of an AST conducted by a certified inspector in accordance with STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks” to assess the condition of the AST to determine its suitability for continued service without entry into the AST interior.</text>
        </paragraph>
        <paragraph num="(8)">
          <text>“Formal inspection” means a documented external inspection or internal inspection of an AST conducted by a certified inspector in accordance with STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”.</text>
        </paragraph>
        <paragraph num="(9)">
          <text>Internal Inspection.</text>
          <paragraph num="(a)">
            <text>“Internal inspection” means a formal inspection of an AST conducted by a certified inspector in accordance with STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks” to assess the internal and external condition of the AST to determine its suitability for continued service.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Internal inspection” includes the requirements of an external inspection in STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(10)">
          <text>Interstitial Space.</text>
          <paragraph num="(a)">
            <text>“Interstitial space” means:</text>
            <paragraph num="(i)">
              <text>The space in a double-walled AST between the primary and secondary storage tank walls; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The space in a double-bottom AST that provides an open or closed void to allow monitoring for a release between two storage tank bottoms.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>“Interstitial space” includes an interstice and an annular space.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(11)">
          <text>“Maximum working level” means the liquid level of a shop-fabricated AST that should not be exceeded during normal filling procedures and is below the activation level of any overfill prevention equipment.</text>
        </paragraph>
        <paragraph num="(12)">
          <text>“New” means the installation or construction of an AST, an AST system, or a secondary containment dike was complete on or after June 13, 2022.</text>
        </paragraph>
        <paragraph num="(13)">
          <text>Out-of-Service.</text>
          <paragraph num="(a)">
            <text>“Out-of-service” means an AST system in which the owner, the operator, and the person in charge of the AST system has:</text>
            <paragraph num="(i)">
              <text>Emptied the AST system of all oil and sludge; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Designated the AST system as out-of-service in accordance with Regulation .13 of this chapter.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>“Out-of-service” includes a change-in-service in which an AST system is emptied of all oil and sludge in order to store a non-oil product.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(14)">
          <text>“Overfill” means an occurrence when an AST is filled beyond the overfill level and may result in a spill, release, or discharge of oil.</text>
        </paragraph>
        <paragraph num="(15)">
          <text>“Overfill level” means the maximum design capacity of a shop-fabricated AST as determined by the AST manufacturer.</text>
        </paragraph>
        <paragraph num="(16)">
          <text>“Repair” means work necessary to maintain or restore an AST system to a safe operating condition using industry approved standards.</text>
        </paragraph>
        <paragraph num="(17)">
          <text>Secondary Containment Dike.</text>
          <paragraph num="(a)">
            <text>“Secondary containment dike” means a secondary containment system that confines a spill, release, or discharge of oil from an AST or piping within the secondary containment system.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Secondary containment dike” includes diking and a dike.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(18)">
          <text>“Secured area” means an area of an oil storage facility or oil handling facility where the owner, the operator, and the person in charge of the facility protects oil storage operations and oil handling operations from unauthorized access by:</text>
          <paragraph num="(a)">
            <text>Providing appropriate security around an AST system, including fencing;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Marking an AST system with the fire hazard category for the type of product stored;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Posting “No Trespassing” signs; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Providing an adequate security lighting system to:</text>
            <paragraph num="(i)">
              <text>Prevent acts of vandalism; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Assist in the detection of spills, releases, and discharges.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(19)">
          <text>“Shop-fabricated AST” means a welded carbon steel or stainless steel AST fabricated in a manufacturing facility, or an AST not otherwise identified as field-erected.</text>
        </paragraph>
        <paragraph num="(20)">
          <text>“Vault” means an enclosure that:</text>
          <paragraph num="(a)">
            <text>May be located above or below grade;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Consists of four walls, a floor, and a top for the purpose of containing an AST;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Allows for the inspection, repair, or maintenance of the vault and an AST; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Is not intended to be occupied by an individual for an extended period of time.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(21)">
          <text>“Vaulted AST” means an AST enclosed within a vault.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="General Requirements.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of a new or relocated AST system with a shop-fabricated AST shall ensure the new or relocated AST system meets the requirements of this chapter.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Unless otherwise specified in this chapter, an owner, an operator, and a person in charge of an existing AST system with a shop-fabricated AST shall ensure the existing AST system meets the requirements of this chapter not later than:</text>
        <paragraph num="(1)">
          <text>2 years after June 13, 2022; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Another time period approved by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall comply with the following permit, license, or approval requirements, when applicable:</text>
        <paragraph num="(1)">
          <text>Obtain an Individual Oil Operations Permit or comply with the General Oil Operations Permit conditions, in accordance with COMAR 26.10.01.09;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Obtain a State discharge permit or National Pollution Discharge Elimination System permit, in accordance with COMAR 26.08.04;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Obtain an Oil Transfer License, in accordance with COMAR 26.10.01.08;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Obtain an Air Quality Permit to Construct, in accordance with COMAR 26.11.02;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Obtain a State Air Quality Permit to Operate, in accordance with COMAR 26.11.02; and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Comply with any other applicable federal, State, or local government permit, license, or approval requirements.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Notwithstanding the compliance schedule in §B of this regulation, an owner, an operator, and a person in charge of an AST system shall register and maintain up-to-date registration of the AST system with the Department in accordance with the procedures and schedule in COMAR 26.10.01.10.</text>
      </paragraph>
      <paragraph num="E.">
        <text>Wetlands and Waterways. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
        <paragraph num="(1)">
          <text>Prior to installing a new or replacement AST system or secondary containment dike, obtain any applicable wetland and waterways authorization stated in COMAR 26.10.01.04E; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If installing the AST system in a location subject to flooding, protect the shop-fabricated AST from flotation by anchoring the storage tank in accordance with NFPA 30A “Code for Motor Fuel Dispensing Facilities and Repair Garages”.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Performance Standards for Vaulted Shop-Fabricated ASTs.">
      <text>An owner, an operator, and a person in charge of an AST system that installs a shop-fabricated AST in a vault shall:</text>
      <paragraph num="A.">
        <text>Construct a UL listed vault;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Ensure the vault and the vaulted AST comply with the design, construction, installation, and operation requirements of:</text>
        <paragraph num="(1)">
          <text>This regulation;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>NFPA 30 “Flammable and Combustible Liquids Code”;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>If the vaulted AST is used as part of a motor fuel dispensing facility, NFPA 30A “Code for Motor Fuel Dispensing Facilities and Repair Garages”; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>NFPA 70 “National Electrical Code” for all electrical wiring;</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Ensure the vaulted AST is:</text>
        <paragraph num="(1)">
          <text>UL listed for aboveground use and for the type of product being stored;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Completely enclosed in the vault; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Not partially or entirely covered by backfill;</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Provide venting for the vault and the vaulted AST according to the following requirements:</text>
        <paragraph num="(1)">
          <text>If the AST stores a Class I liquid, vent the vault in accordance with NFPA 30 “Flammable and Combustible Liquids Code”;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Terminate a normal vent for the vaulted AST:</text>
          <paragraph num="(a)">
            <text>Outside of the vault;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>At least 12 feet above ground level; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>At least 5 feet from a building opening;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>A normal vent for the vaulted AST may not terminate in a location that allows vapors to be trapped by the eaves of a building;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Ensure that an emergency vent for the vaulted AST is vapor-tight and allows for the venting of vapors inside of the vault; and</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Do not use a long-bolt manhole cover as an emergency vent for the vaulted AST;</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Install vapor and liquid detection systems in the vault that meet the following requirements:</text>
        <paragraph num="(1)">
          <text>The vapor detection system:</text>
          <paragraph num="(a)">
            <text>Is equipped with an on-site alarm that has a battery backup;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Has vapor detectors located not higher than 12 inches above the lowest point in the vault; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Is set to alarm when vapors reach or exceed 25 percent of the lower flammable limit of the oil stored;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The liquid detection system is:</text>
          <paragraph num="(a)">
            <text>Set to alarm upon detection of a liquid; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Located in accordance with the liquid detection system manufacturer’s instructions; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>The vapor and liquid detection systems required under §E(1) and (2) of this regulation are designed so that if either system alarms, a signal alerts the owner, the operator, and the person in charge of the AST system:</text>
          <paragraph num="(a)">
            <text>At a constantly attended location where the vaulted AST is located; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>At another location that is continually monitored; and</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>Ensure the vaulted shop-fabricated AST complies with the spill and overfill prevention requirements in Regulation .08 of this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Performance Standards for AST Systems with a Shop-Fabricated AST.">
      <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
      <paragraph num="A.">
        <text>Ensure the AST system is:</text>
        <paragraph num="(1)">
          <text>Properly selected for the oil storage application and type of oil stored; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Constructed to an industry standard, including a UL, STI or API standard;</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Ensure the foundation for a stationary shop-fabricated AST is:</text>
        <paragraph num="(1)">
          <text>Constructed to:</text>
          <paragraph num="(a)">
            <text>Support the AST;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Prevent movement and uneven settlement of the foundation and the AST; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Provide positive drainage of water away from the foundation;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Capable of supporting the soil-bearing pressure of the AST and its contents; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Designed by a qualified professional engineer using field and laboratory testing and analyses, if the AST system is located in an area subject to flooding;</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Install an elevated AST system, unless:</text>
        <paragraph num="(1)">
          <text>An alternate AST system is approved by the Department in writing; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The owner, the operator, and the person in charge of the alternate AST system installs, tests, and maintains a cathodic protection system in accordance with Regulation .10 of this chapter; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Test a new, repaired, or relocated AST system for tightness in accordance with NFPA 30 “Flammable and Combustible Liquids Code”:</text>
        <paragraph num="(1)">
          <text>Upon completing the installation or repair of the AST system; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Before placing the AST system in-service.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Performance Standards for Piping.">
      <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
      <paragraph num="A.">
        <text>If installing or relocating a shop-fabricated AST on or after June 13, 2022, install piping that does not penetrate a secondary containment dike, unless otherwise approved by the Department;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Ensure an existing shop-fabricated AST meets the following requirements:</text>
        <paragraph num="(1)">
          <text>For piping connected to an AST penetrating a secondary containment dike:</text>
          <paragraph num="(a)">
            <text>Obtain approval from the Department to leave the piping in place; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Properly abandon and replace the piping not later than 1 year after June 13, 2022 with piping that does not penetrate the secondary containment dike; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>For underground piping connected to an AST, ensure the piping complies with the underground piping requirements in §E of this regulation not later than 1 year after June 13, 2022;</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Ensure an aboveground piping system connected to a shop-fabricated AST is:</text>
        <paragraph num="(1)">
          <text>Constructed of carbon steel, alloy steel, or stainless steel piping;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Compatible with the type of oil transferred in the piping;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Designed and constructed in accordance with recognized industry standards;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Liquid tight;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Properly supported by permanent bracing to prevent structural weaknesses; and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Protected against physical damage;</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Ensure a piping system installed aboveground or inside of a building is not constructed with:</text>
        <paragraph num="(1)">
          <text>Low melting point materials, such as aluminum, copper, or brass;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Materials that soften on fire exposure, such as plastics; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Non-ductile materials, such as cast iron;</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>If installing an underground piping system, comply with the following requirements:</text>
        <paragraph num="(1)">
          <text>Install the piping system, including containment sumps, in accordance with the performance standards in COMAR 26.10.03.02 and .03A(3);</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Installation of the piping system is performed in the continuous on-site presence and under the direction of a certified UST system technician, as required under COMAR 26.10.02.03D;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Test the piping system for tightness in accordance with COMAR 26.10.03.05 and 26.10.05.02D;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Test the containment sumps for tightness in accordance with COMAR 26.10.03.03A(3);</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Provide a method of leak detection in accordance with COMAR 26.10.05.02D;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Maintain the containment sumps clean and free of liquid; and</text>
        </paragraph>
        <paragraph num="(7)">
          <text>If a test for tightness conducted in accordance with §E(3) or (4) of this regulation results in a failed test result or a leak is found:</text>
          <paragraph num="(a)">
            <text>Report the failed test result to the Department within 2 hours in accordance with COMAR 26.10.08.01; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Follow the investigation and confirmation procedures in COMAR 26.10.08.03, including making repairs and retesting the piping system and containment sumps for tightness.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Secondary Containment.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall surround the AST system with a continuous secondary containment dike that meets the requirements of this regulation if:</text>
        <paragraph num="(1)">
          <text>The shop-fabricated AST is a single-walled AST with a capacity of 10,000 gallons or greater;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The shop-fabricated AST is a double-walled AST with a capacity of 10,000 gallons or greater, unless the double-walled shop-fabricated AST meets the conditions in §B of this regulation; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The Department determines that the AST system poses a water pollution hazard due to its size, nature, or location.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a double-walled shop-fabricated AST is exempt from the requirement to install a secondary containment dike around the double-walled shop-fabricated AST provided the AST system:</text>
        <paragraph num="(1)">
          <text>Has overfill prevention equipment in accordance with Regulation .08 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Has a method of release detection in accordance with Regulation .09 of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Is located within a secured area; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Meets one of the following conditions:</text>
          <paragraph num="(a)">
            <text>The AST system is part of a motor fuel dispensing facility, has a storage capacity not greater than 12,000 gallons, and stores a Class I liquid;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The AST system is part of a motor fuel dispensing facility, has a storage capacity not greater than 15,000 gallons, and stores a Class II liquid; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The AST system is not part of a motor fuel dispensing facility, has a storage capacity not greater than 20,000 gallons, and stores a Class II liquid or Class III liquid.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Compliance Schedule.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has a new secondary containment dike shall meet the requirements in §§D—J of this regulation upon installation of the secondary containment dike.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Unless otherwise provided in this regulation, an owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has an existing secondary containment dike shall meet the requirements in §§D—J of this regulation not later than:</text>
          <paragraph num="(a)">
            <text>2 years after June 13, 2022; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Another time period approved by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST required under §A of this regulation to have a secondary containment dike shall ensure the secondary containment dike:</text>
        <paragraph num="(1)">
          <text>Can contain a spill, release, or discharge from an AST and connected piping within the secondary containment dike surrounding the AST until the spill, release, or discharge is detected and removed;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Is designed by a professional engineer;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Is approved by the Department;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Is designed with consideration given to the soil and groundwater conditions at the oil storage facility or oil handling facility;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Prevents movement of oil into, near, or in an area likely to pollute waters of the State;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Provides safe ingress and egress for an individual;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Prevents water accumulation at an AST foundation;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>If the secondary containment dike surrounds two or more ASTs, is subdivided in accordance with NFPA 30 “Flammable and Combustible Liquids Code”;</text>
        </paragraph>
        <paragraph num="(9)">
          <text>If the secondary containment dike is exposed to precipitation, is designed and constructed to effectively hold 110 percent of the maximum capacity of the largest AST in the area enclosed by the secondary containment dike; and</text>
        </paragraph>
        <paragraph num="(10)">
          <text>Is constructed so that the secondary containment dike, upon testing, meets one of the following permeability criteria:</text>
          <paragraph num="(a)">
            <text>A permeability of less than 10-4 centimeters per second; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A product level drop rate of less than 1 centimeter per 3 hours.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Within 90 days of conducting a permeability test on a secondary containment dike or another time period approved by the Department, an owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall repair or replace a secondary containment dike that does not meet one of the permeability criteria listed in §D(10) of this regulation.</text>
      </paragraph>
      <paragraph num="F.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has an earthen secondary containment dike shall conduct permeability testing on the earthen secondary containment dike according to the following requirements:</text>
        <paragraph num="(1)">
          <text>For an existing earthen secondary containment dike that has not been previously tested for permeability, test the existing earthen secondary containment dike for permeability using an industry standard approved by the Department not later than 1 year after June 13, 2022;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Test a new earthen secondary containment dike for permeability using an industry standard approved by the Department upon completing the construction of the earthen secondary containment dike and prior to placing the AST in-service; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Submit the results of the permeability testing to the Department not later than 60 days after the test.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has a secondary containment dike shall maintain written verification that the secondary containment dike meets the applicable requirements in §D—F of this regulation in accordance with Regulation .14 of this chapter.</text>
      </paragraph>
      <paragraph num="H.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has a secondary containment dike shall ensure a drain valve installed in the secondary containment dike is:</text>
        <paragraph num="(1)">
          <text>Not a flapper-type valve; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Except when being used to drain trapped water in accordance with §I of this regulation, kept completely closed and locked at all times.</text>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>When draining trapped water from a secondary containment dike, an owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has the secondary containment dike shall:</text>
        <paragraph num="(1)">
          <text>Ensure the drainage leaving the secondary containment dike does not have any visible evidence of oil sheen;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Designate a representative to supervise, monitor, and document each drainage event from the secondary containment dike;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Keep a log that includes the following information for each secondary containment dike drainage event:</text>
          <paragraph num="(a)">
            <text>The name of the employee supervising, monitoring, and documenting the drainage;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The date of drainage event;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The time the drainage event started and ended;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The estimated volume of water drained; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>A description of the water quality, such as the presence of an oil sheen; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Maintain the log required by §I(3) of this regulation in accordance with Regulation .14 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="J.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has a secondary containment dike shall maintain the secondary containment dike clear and free of:</text>
        <paragraph num="(1)">
          <text>Vegetation; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Flammable and combustible materials, including oil.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Spill and Overfill Prevention.">
      <paragraph num="A.">
        <text>To prevent a spill, release, or discharge of oil due to an overfill of a shop-fabricated AST, an owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
        <paragraph num="(1)">
          <text>Establish written procedures for filling the AST and maintain the procedures at the oil storage facility or oil handling facility;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Ensure the AST is:</text>
          <paragraph num="(a)">
            <text>Normally filled to a level that does not exceed the maximum working level of the AST; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Never filled to the overfill level of the AST; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>If required under NFPA 30 “Flammable and Combustible Liquids Code” or §G of this regulation, install, operate, inspect, maintain, and test overfill prevention equipment in accordance with:</text>
          <paragraph num="(a)">
            <text>The requirements of this regulation and Regulation .12 of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>NFPA 30 “Flammable and Combustible Liquids Code”; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>PEI RP 600 “Recommended Practices for Overfill Prevention for Shop-Fabricated Aboveground Tanks”.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST may not use overfill prevention equipment:</text>
        <paragraph num="(1)">
          <text>To control AST filling operations at an oil storage facility or oil handling facility; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>That restricts or interferes with the functioning of the normal or emergency vent of the AST.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>In accordance with COMAR 26.10.08.04, an owner, an operator, and a person in charge of an AST system with a shop-fabricated AST and a responsible party shall:</text>
        <paragraph num="(1)">
          <text>Report and investigate a spill, release, or discharge from the AST system or an overfill; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Remediate the spill, release, or discharge or the overfill.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Delivery and Transfer Operations. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
        <paragraph num="(1)">
          <text>Confirm that the ullage available in the AST is greater than the volume of oil to be transferred to the AST before a delivery or transfer begins;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>During a delivery or transfer operation, ensure:</text>
          <paragraph num="(a)">
            <text>A spill, release, or discharge of oil does not occur due to overfilling the AST or spilling oil during the transfer; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The delivery or transfer operation is constantly monitored to prevent overfilling of the AST and spilling of oil;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Ensure the delivery or transfer operation is conducted in accordance with the requirements in COMAR 26.10.01.16—.18 and NFPA 385 “Standard for Tank Vehicles for Flammable and Combustible Liquids”; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>If the delivery is by truck tank or transport with a cargo tank capacity of 500 gallons or greater, confirm the company making an oil delivery or transfer holds a valid Individual Oil Operations Permit from the Department in accordance with COMAR 26.10.01.09.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Liquid Level Measurements. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
        <paragraph num="(1)">
          <text>Gauge the liquid level and record the measurements in writing before filling the AST; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Maintain the records required under §E(1) of this regulation in accordance with Regulation .14 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>Tank Gauge. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
        <paragraph num="(1)">
          <text>Equip the shop-fabricated AST with a tank gauge or other equivalent monitoring device that is:</text>
          <paragraph num="(a)">
            <text>Directly visible during a transfer operation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Accurately measures the level or quantity of oil in the AST;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Independent of any overfill prevention equipment; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Maintained in working order;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Install and maintain the tank gauge or other equivalent monitoring device in accordance with the manufacture’s specifications; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Inspect and calibrate the tank gauge or other equivalent monitoring device at least once per year.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has a storage capacity of 10,000 gallons or greater and is not located within a secondary containment dike shall install the following overfill prevention equipment on the AST system:</text>
        <paragraph num="(1)">
          <text>An overfill alarm that:</text>
          <paragraph num="(a)">
            <text>Has a test function to allow the operability of the device to be confirmed prior to each delivery or transfer of oil;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Consists of a visual alarm and an audible alarm that alerts an individual involved in the oil delivery or transfer operation; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Goes into alarm when the liquid level in the AST reaches 90 percent of the overfill level and upon failure or malfunction of the overfill device; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An automatic shut-off device that:</text>
          <paragraph num="(a)">
            <text>Has a test function to allow the operability of the device to be confirmed prior to each delivery or transfer of oil;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Automatically shuts off the flow of oil into the AST when the liquid level reaches 95 percent of the overfill level; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Is equipped with a fail-safe mechanism that will trigger an alarm and shut off the flow of oil into the AST in the event of a device failure or malfunction.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST using overfill prevention equipment shall:</text>
        <paragraph num="(1)">
          <text>At least monthly, inspect and perform maintenance of overfill protection equipment in accordance with the manufacturer’s instructions; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At least annually, perform functional testing of overfill protection equipment in accordance with the manufacturer’s instructions.</text>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>Labeling. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
        <paragraph num="(1)">
          <text>Provide the following labeling on the AST system:</text>
          <paragraph num="(a)">
            <text>The storage capacity of the AST in gallons;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The type of oil stored or last stored in the AST prior to being placed out-of-service;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A proper NFPA 704 “Standard System for the Identification of the Hazards of Materials for Emergency Response” placard; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>If the AST system was placed out-of-service in accordance with Regulation .13 of this chapter, the words “OUT-OF-SERVICE” or “EMPTY”; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Permanently and clearly mark the shop-fabricated AST with the information listed in §I(1) of this regulation on, not less than two sides of the AST and in locations that are highly visible to employees of an oil storage facility or oil handling facility, contractors, government representatives, and emergency response personnel.</text>
        </paragraph>
      </paragraph>
      <paragraph num="J.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall maintain records related to spill and overfill prevention measures required under this regulation in accordance with Regulation .14 of this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".09" heading="Release Detection.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall provide a method or combination of release detection methods that detect a spill, release, or discharge from the AST system through:</text>
        <paragraph num="(1)">
          <text>Visual inspections of the AST system in accordance with Regulation .12 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A continuous electronic release detection system; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A continuous mechanical release detection system.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST using a continuous electronic or mechanical release detection system shall:</text>
        <paragraph num="(1)">
          <text>Install, calibrate, operate, and maintain the release detection system in accordance with the manufacturer’s instructions; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At least annually:</text>
          <paragraph num="(a)">
            <text>Perform routine maintenance on the release detection system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Check the release detection system for operability at scheduled service checks; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Per the manufacturer’s specifications, inspect, field-test, or calibrate the release detection system to verify that the selected release detection method is being maintained and operated properly to detect a spill, release, or discharge.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall monitor underground piping connected to the AST for spill, releases, and discharges in accordance with COMAR 26.10.05.02D.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".10" heading="Corrosion Protection.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has a capacity less than 10,000 gallons shall install an elevated AST so that the storage tank is not in direct contact with soil or another material that may allow moisture penetration or corrosion.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST that has a capacity of 10,000 gallons or greater, is not an elevated AST, and in direct contact with soil or another material that may allow moisture penetration or corrosion shall:</text>
        <paragraph num="(1)">
          <text>Provide one of the following cathodic protection systems:</text>
          <paragraph num="(a)">
            <text>An impressed current system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A galvanic system; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Subject to the approval of the Department, an alternative method of corrosion protection that is:</text>
            <paragraph num="(i)">
              <text>Designed to prevent a spill, release, or discharge of oil or a threatened spill, release, or discharge of oil in a manner determined by the Department to be not less protective of human health and the environment than the methods in §B(1)(a) and (b) of this regulation; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Approved by a corrosion expert; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Provide a cathodic protection system that is:</text>
          <paragraph num="(a)">
            <text>Designed by a corrosion expert;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Designed and tested, at a minimum, in accordance with the following industry standards and recommended practices:</text>
            <paragraph num="(i)">
              <text>NACE SP0169-2013 “Control of External Corrosion on Underground or Submerged Metallic Piping Systems”;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>NACE SP0193-2016 “Application of Cathodic Protection to Control External Corrosion of Carbon Steel On-Grade Storage Tank Bottoms”;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>NACE TM0497-2018 “Measurement Techniques Related to Criteria for Cathodic Protection on Underground or Submerged Metallic Piping Systems”; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>API Recommended Practice 651 “Cathodic Protection of Aboveground Petroleum Storage Tanks”;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Designed and installed to provide continuous corrosion protection to the external portion of the AST and other metal components of the AST system in contact with soil or other materials that may allow corrosion;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Installed with easily identifiable test stations, access points, or other methods to monitor the operation and functionality of the cathodic protection system; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Continuously operated and maintained for the in-service and out-of-service life of the AST system.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Impressed Current System. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST system protected by an impressed current system shall:</text>
        <paragraph num="(1)">
          <text>Install, operate, maintain, inspect, and test the impressed current system in accordance with the requirements of this section;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Ensure the impressed current source is not de-energized at any time except to perform service work on the AST system;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Ensure the impressed current source is equipped with a continuously operating meter that displays the voltage, amperage, and operating (run) time;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>At least once every 60 days:</text>
          <paragraph num="(a)">
            <text>Inspect the impressed current system to ensure the cathodic protection system is functioning properly by:</text>
            <paragraph num="(i)">
              <text>Verifying the power source to the impressed current system is on; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Recording the voltage, amperage, and operating time; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Record and maintain the inspection results in accordance with Regulation .14 of this chapter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>At least annually:</text>
          <paragraph num="(a)">
            <text>Have a cathodic protection tester inspect and test:</text>
            <paragraph num="(i)">
              <text>The impressed current system for electrical shorts, ground connections, meter accuracy, and circuit resistance; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The condition of the impressed current system’s isolating devices, continuity bonds, and insulators; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Record and maintain the results of the inspection and test in accordance with Regulation .14 of this chapter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>Have a corrosion expert inspect the impressed current system in accordance with an industry standard or recommended practice listed in §B(2) of this regulation:</text>
          <paragraph num="(a)">
            <text>When the impressed current system is 5 years of age; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Every 5 years thereafter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>Provide a complete report for an inspection performed pursuant to §C(6) of this regulation to the Department and maintain a copy of the report in accordance with Regulation .14 of this chapter;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Except as provided in §C(9) of this regulation, if the protection provided by an impressed current system is determined to be inadequate to properly protect the AST system:</text>
          <paragraph num="(a)">
            <text>Employ a corrosion expert to determine the cause of the inadequacy within 30 days of the discovery; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Either:</text>
            <paragraph num="(i)">
              <text>Complete repairs of the impressed current system within 60 days of the discovery or on a schedule approved by the Department; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If repairs cannot return the impressed current system to adequate performance, replace the impressed current system within 120 days of the discovery or on a schedule approved by the Department; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(9)">
          <text>If an impressed current system determined to be inadequate to provide proper protection to the AST system cannot be repaired or replaced in accordance with §C(8) of this regulation:</text>
          <paragraph num="(a)">
            <text>Empty all oil in contact with the portion of the AST system inadequately protected by the impressed current system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Place the AST system out-of-service in accordance with Regulation .13 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Galvanic System. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST system protected by a galvanic system shall:</text>
        <paragraph num="(1)">
          <text>Install, operate, maintain, inspect, and test the galvanic system in accordance with the requirements of this section;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Comply with the following inspection and test requirements:</text>
          <paragraph num="(a)">
            <text>A cathodic protection tester shall inspect and test the galvanic system in accordance with an industry standard or recommended practice listed in §B(2) of this regulation:</text>
            <paragraph num="(i)">
              <text>Within 6 months of installing the galvanic system; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>At least annually thereafter;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>A cathodic protection tester conducting an annual inspection shall make and record a sufficient number of AST-to-soil and underground piping-to-soil potential measurements to determine if the AST system is completely protected in accordance with an industry standard or recommended practice listed in §B(2) of this regulation; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Maintain records of the AST-to-soil and underground piping-to-soil potential measurements in accordance with Regulation .14 of this chapter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Except as provided under §D(4) of this regulation, if the protection provided by a galvanic system is determined to be inadequate to properly protect the AST system:</text>
          <paragraph num="(a)">
            <text>Employ a corrosion expert to determine the cause of the inadequacy within 30 days of the discovery; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Either:</text>
            <paragraph num="(i)">
              <text>Complete repairs of the galvanic system within 60 days of the discovery or on a schedule approved by the Department; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If repairs cannot return the galvanic system to adequate performance, replace the galvanic system within 120 days of the discovery or on a schedule approved by the Department; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>If a galvanic system determined to be inadequate to provide proper protection to the AST system cannot be repaired or replaced in accordance with §D(3) of this regulation:</text>
          <paragraph num="(a)">
            <text>Empty all oil in contact with the portion of the AST system inadequately protected by the galvanic system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Place the AST system out-of-service in accordance with Regulation .13 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".11" heading="Normal and Emergency Venting.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall ensure the normal venting for the shop-fabricated AST meets the following requirements:</text>
        <paragraph num="(1)">
          <text>Design and construct the normal venting in accordance with one of the following industry standards:</text>
          <paragraph num="(a)">
            <text>UL 142 “Standard for Safety, Steel Aboveground Tanks for Flammable and Combustible Liquids”; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>API Standard 2000 “Venting Atmospheric and Low-pressure Storage Tanks”;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The normal venting requirements for ASTs listed in NFPA 30 “Flammable and Combustible Liquids Code”; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Vent an atmospheric pressure AST to prevent the development of vacuum or pressure above a 1.0 psi (6.9 kPa) maximum operating pressure.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall ensure the emergency venting for the shop-fabricated AST meets the following requirements:</text>
        <paragraph num="(1)">
          <text>Design and construct emergency venting in accordance with one of the following industry standards:</text>
          <paragraph num="(a)">
            <text>UL 142 “Standard for Safety, Steel Aboveground Tanks for Flammable and Combustible Liquids”; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>API Standard 2000 “Venting Atmospheric and Low-pressure Storage Tanks”; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Emergency venting meets the requirements in NFPA 30 “Flammable and Combustible Liquids Code”.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".12" heading="Inspection Requirements for an AST System.">
      <paragraph num="A.">
        <text>Periodic Visual Inspections.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall conduct periodic visual inspections in accordance with:</text>
          <paragraph num="(a)">
            <text>The inspection procedures under §A(2) or (3) of this regulation; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The recordkeeping requirements under §A(4) and (5) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST may meet the visual inspections requirement in §A(1) of this regulation by, at a minimum:</text>
          <paragraph num="(a)">
            <text>Inspecting for the following conditions monthly:</text>
            <paragraph num="(i)">
              <text>Signs of spills, releases, or discharges from any portion of the AST system;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Water in the secondary containment dike and AST or, if a double-walled AST, the primary storage tank and interstice;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The condition of the secondary containment dike, including drain valves;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Signs of shell distortion;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Signs of settlement;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Signs of corrosion;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>The condition of the AST foundation or supports;</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>The condition of the exterior coating of the AST system;</text>
            </paragraph>
            <paragraph num="(ix)">
              <text>The condition of seams, rivets, and nozzle connections;</text>
            </paragraph>
            <paragraph num="(x)">
              <text>The condition of valves, pumps, piping, and other appurtenances directly connected to the AST;</text>
            </paragraph>
            <paragraph num="(xi)">
              <text>The condition of the tank gauge or an equivalent monitoring device;</text>
            </paragraph>
            <paragraph num="(xii)">
              <text>The condition of release detection systems; and</text>
            </paragraph>
            <paragraph num="(xiii)">
              <text>The condition of overfill protection equipment;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Inspecting containment sumps associated with an underground piping system monthly by:</text>
            <paragraph num="(i)">
              <text>Checking for evidence of a spill, release or discharge; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Removing any liquid or debris; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Removing any water found during the monthly inspection from the secondary containment dike and AST or, if a double-walled AST, the primary storage tank and interstice.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST may meet the periodic visual inspections requirement in §A(1) of this regulation by conducting periodic AST inspections in accordance with STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall maintain the following records related to periodic visual inspections:</text>
          <paragraph num="(a)">
            <text>If the AST system was inspected in accordance with §A(2) of this regulation, a written log or electronic record that includes:</text>
            <paragraph num="(i)">
              <text>The date of the inspection;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The name and title of the individual performing the inspection;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A description of each deficiency found;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The name and title of the individual notified of the deficiencies found; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>A record of how and when the deficiencies were corrected; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>If the AST system was inspected in accordance with §A(3) of this regulation, the completed monthly and annual inspection checklists in STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall maintain the records required in §A(4) of this regulation in accordance with Regulation .14 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall conduct corrosion protection system inspections in accordance with Regulation .10 of this chapter.</text>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
        <paragraph num="(1)">
          <text>Inspect and clean normal and emergency vents for the shop-fabricated AST annually; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Maintain records of the vent inspection and cleaning required in §C(1) of this regulation in accordance with Regulation .14 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Formal Inspections and Leak Testing. In accordance with the procedures in STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”, an owner, an operator, and a person in charge of an oil storage facility or oil handling facility operating under an Individual Oil Operations Permit required under COMAR 26.10.01.09A shall:</text>
        <paragraph num="(1)">
          <text>As described in Section 5.0 of STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”, determine the formal inspection and leak testing schedule by the shop-fabricated AST size and category;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Have a certified inspector conduct formal external inspections and formal internal inspections on a shop-fabricated AST;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Have properly trained personnel conduct leak tests on a shop-fabricated AST in conjunction with a certified inspector conducting formal inspections on the shop-fabricated AST; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Comply with the formal inspection report requirements under §E of this regulation.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Formal Inspection Report.</text>
        <paragraph num="(1)">
          <text>The certified inspector that conducts a formal external inspection or formal internal inspection of a shop-fabricated AST in accordance with §D of this regulation shall complete a final report for the formal inspection that, at a minimum:</text>
          <paragraph num="(a)">
            <text>Includes field data, measurements, pictures, drawings, tables, and an inspection summary;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Identifies unacceptable conditions and recommends corrective actions;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Determines the suitability of the AST for continued service per Section 10.0 of STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Includes the date of the next scheduled formal external inspection or formal internal inspection; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Includes the name and STI SP001 certification number of the certified inspector.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner, an operator, and a person in charge of an oil storage facility described in §D of this regulation shall:</text>
          <paragraph num="(a)">
            <text>Include the leak test results and supporting data in the final report for a shop-fabricated AST required under §E(1) of this regulation; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Maintain the final reports completed for each formal inspection and leak test conducted on a shop-fabricated AST in accordance with Regulation .14 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".13" heading="Out-of-Service and Permanent Closure.">
      <paragraph num="A.">
        <text>The requirements of this regulation apply to an owner, an operator, and a person in charge of an AST system with a shop-fabricated AST required under COMAR 26.10.01.10 to register the AST system with the Department.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Out-of-Service. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall complete each of the following steps to place the AST system out-of-service:</text>
        <paragraph num="(1)">
          <text>Remove all oil from the AST system;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Isolate all piping connected to the AST;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Remove all waste materials from the AST system, including storage tank-bottom sludge, and dispose of these materials in compliance with applicable federal, State, and local laws;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Purge all petroleum vapors and maintain the AST system vapor free;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Secure the AST system to prevent unauthorized entrance or tampering;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Protect the AST system from flotation;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Continue the operation and maintenance of corrosion protection on the AST system in accordance with Regulation .10 of this chapter;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Lock the fill port;</text>
        </paragraph>
        <paragraph num="(9)">
          <text>Label the AST using lettering at least 3 inches high, in a readily visible location on the AST, with the following information:</text>
          <paragraph num="(a)">
            <text>Date the AST was placed out-of-service;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Name of product last stored; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The words “OUT-OF-SERVICE” or “EMPTY”; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(10)">
          <text>Notify the Department in writing 30 days before placing the AST system out-of-service.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Return to In-Service. An owner, an operator, and a person in charge of an out-of-service AST system with a shop-fabricated AST shall complete each of the following steps prior to placing the AST system in-service:</text>
        <paragraph num="(1)">
          <text>If a formal inspection and leak test was due to occur while the AST system was out-of-service, conduct a formal inspection and leak test of the AST system in accordance with Regulation .12 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Test all connected piping and appurtenances to ensure a spill, release, or discharge will not occur;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Maintain a copy of all corrosion protection system and formal inspection and testing reports, including the findings of inspections and tests and repairs performed, and provide a copy to the Department upon request; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Notify the Department in writing 30 days before placing the AST system in-service.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Permanent Closure. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall permanently close the AST system in accordance with the following requirements:</text>
        <paragraph num="(1)">
          <text>At least 30 days before beginning the permanent closure of the AST system:</text>
          <paragraph num="(a)">
            <text>Notify the Department in writing of the planned AST system permanent closure; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Submit to the Department for approval a proposed sampling plan for a site assessment to determine if there is evidence of a spill, release, or discharge where contamination is most likely to be present, which includes the sampling of, at a minimum, the following areas of the AST site:</text>
            <paragraph num="(i)">
              <text>Within and immediately outside of the secondary containment dike, if present;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Within the footprint of the removed AST; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Beneath underground piping associated with the removed AST;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Place the AST system out-of-service in accordance with §B of this regulation;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Comply with PEI RP 1700 “Recommended Practices for the Closure of Underground Storage Tank and Shop-Fabricated Aboveground Storage Tank Systems”;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Disconnect and remove all aboveground piping associated with the AST system;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Disconnect and remove all underground piping associated with the AST system:</text>
          <paragraph num="(a)">
            <text>Under the continuous on-site presence and direction of a certified UST system technician or remover; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In accordance with the UST system permanent closure procedures in COMAR 26.10.10.02D;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>Remove the AST and associated piping from the site; and</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Within 45 days of completing the permanent closure and approved site assessment, submit a closure report to the Department detailing:</text>
          <paragraph num="(a)">
            <text>The AST closure activities; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The results of the sampling event, including a map identifying sample locations, laboratory results, summary of findings, and conclusions.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Change-in-Service. An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST placing the AST system out-of-service in order to store a non-oil product in the AST system shall:</text>
        <paragraph num="(1)">
          <text>Notify the Department in writing at least 30 days before placing the AST system out-of-service; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Place the AST system out-of-service in accordance with the requirements of the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>Upon completing an out-of-service activity specified §§B—E of this regulation, an owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
        <paragraph num="(1)">
          <text>Within 30 days, amend the AST system registration with the Department in accordance with COMAR 26.10.01.10; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If the oil storage facility or oil handling facility is required under COMAR 26.10.01.09 to be operated under an Individual Oil Operation Permit, submit a request to modify the Individual Oil Operations Permit in accordance with COMAR 26.10.01.12.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".14" heading="Recordkeeping.">
      <text>An owner, an operator, and a person in charge of an AST system with a shop-fabricated AST shall:</text>
      <paragraph num="A.">
        <text>Maintain the records required under this chapter at the oil storage facility or oil handling facility, or another a readily accessible location;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Provide the records to the Department upon request;</text>
      </paragraph>
      <paragraph num="C.">
        <text>Retain the following records for a minimum of 5 years:</text>
        <paragraph num="(1)">
          <text>Records of periodic visual inspections conducted in accordance with Regulation .12A of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Records of annual normal and emergency vent inspections and cleaning conducted in accordance with Regulation .12C of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Inventory control records;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Overfill prevention equipment testing records;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Release detection records;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Secondary containment dike drainage logs;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Tank gauging device calibration records; and</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Testing records for aboveground and underground piping; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Retain the following AST system records for the operational life of an AST system and for at least 5 years after an AST system was permanently closed in accordance with Regulation .13 of this chapter:</text>
        <paragraph num="(1)">
          <text>Construction records, including records of:</text>
          <paragraph num="(a)">
            <text>The AST name plate information;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The original as-built specifications and drawings and any modifications made to the AST system during the operational life of the AST system;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Applicable manufacturer’s documentation for ancillary equipment;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Tests conducted upon completing an installation or repair of an AST system component, including hydrostatic testing and pressure tightness testing;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Material tests and analyses, including secondary containment dike permeability tests; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>The names of the companies performing construction activities and a description of the work performed;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Cathodic protection system inspections records for impressed current and galvanic systems, including records of:</text>
          <paragraph num="(a)">
            <text>Cathodic protection system design description;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Inspection findings and conclusions;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Recommendations; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Testing and repair records;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>A complete copy of each final report for a formal inspection;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Records of AST system repairs and alteration history, including names of companies completing repair work;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Records of secondary containment dike testing and evaluation;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Records of spills, releases, and discharges and written reports of the occurrences required by COMAR 26.10.01.05E; and</text>
        </paragraph>
        <paragraph num="(7)">
          <text>A closure report for an AST system permanently closed in accordance with Regulation .13 of this chapter.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401—4-403, 4-405, 4-406, 4-408, 4-410—4-412, 4-415-1—4-418, 4-501, and 4-502, Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>
  <chapter num="18" heading="Field-Erected Aboveground Storage Tanks">
    <regulation prefix="Regulation" num=".01" heading="Scope.">
      <paragraph num="A.">
        <text>This chapter applies to an owner, an operator, and a person in charge of an AST system with a field-erected AST that is used or may be used to store oil at an oil storage facility or oil handling facility.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system subject to the requirements in this chapter shall meet all applicable requirements under COMAR 26.10.01 for an oil storage facility or an oil handling facility.</text>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST used for storing asphalt only is exempt from the following requirements of this chapter:</text>
        <paragraph num="(1)">
          <text>The spill and overfill prevention requirements in Regulation .07 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>The release detection requirements in Regulation .08 of this chapter; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>The emergency venting requirement in Regulation .10B of this chapter if the AST system larger than 12,000 gallon capacity and is not located in:</text>
          <paragraph num="(a)">
            <text>A secondary containment dike with another AST system storing a Class I liquid or Class II liquid; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The drainage path of another AST system storing a Class I liquid or Class II liquid.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".02" heading="Definitions.">
      <paragraph num="A.">
        <text>In this chapter:</text>
        <paragraph num="(1)">
          <text>A term in §B of this regulation has the meaning indicated; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A term not defined in §B of this regulation has:</text>
          <paragraph num="(a)">
            <text>The meaning given to the term in a relevant statute or COMAR 26.10.01 or 26.10.02; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If not defined in a relevant statute or COMAR 26.10.01 or 26.10.02, the meaning attributed by common use.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Terms Defined.</text>
        <paragraph num="(1)">
          <text>“AST” has the meaning stated in COMAR 26.10.01.02B.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>“AST system” has the meaning stated in COMAR 26.10.01.02B.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>“Authorized inspector” means an individual qualified and certified to inspect an AST under API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction”.</text>
        </paragraph>
        <paragraph num="(4)">
          <text>“Coating” means a protective material applied to or bonded to an internal or external AST surface, including paint, protective metals, adhered plastic, or polyolefin materials.</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Critical High Level.</text>
          <paragraph num="(a)">
            <text>“Critical high level” means the highest level in a field-erected AST that oil can reach without detrimental impacts, such as an overflow of oil from the AST or damage to the AST.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Critical high level” includes the design liquid level of a field-erected AST as determined by the AST manufacturer.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>“Existing” means the installation or construction of an AST, an AST system, or a secondary containment dike was complete before June 13, 2022.</text>
        </paragraph>
        <paragraph num="(7)">
          <text>“External inspection” means a formal inspection of an AST to assess all aspects of the storage tank possible without suspending operations or requiring an AST shutdown, performed by or under the supervision of an authorized inspector in accordance with API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction” and Regulation .11F of this chapter.</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Field-erected AST.</text>
          <paragraph num="(a)">
            <text>“Field-erected AST” means an AST that is:</text>
            <paragraph num="(i)">
              <text>Welded carbon steel or stainless steel;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Erected or constructed by assembling the AST on-site at an oil storage facility; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Erected or constructed for the purpose of storing oil.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>“Field-erected AST” includes an AST that:</text>
            <paragraph num="(i)">
              <text>Has a nameplate or other identifier that indicates it is a field-erected AST; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Is not identified as a shop-fabricated AST.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(9)">
          <text>“Formal inspection” means a documented external inspection or internal inspection of an AST conducted by or under the supervision of an authorized inspector in accordance with API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction” and Regulation .11 of this chapter.</text>
        </paragraph>
        <paragraph num="(10)">
          <text>“High-high level” means a level in a field-erected AST established under Regulation .07 of this chapter that:</text>
          <paragraph num="(a)">
            <text>Is sufficiently below the critical high level of the AST; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Enables the termination of an oil delivery or transfer before the critical high level in the AST is reached.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(11)">
          <text>“Internal inspection” means a formal and complete inspection of an emptied and cleaned AST performed under the supervision of an authorized inspector in accordance with API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction” and Regulation .11H of this chapter.</text>
        </paragraph>
        <paragraph num="(12)">
          <text>Maximum Working Level.</text>
          <paragraph num="(a)">
            <text>“Maximum working level” means a liquid level of a field-erected AST that should not be exceeded during normal filling procedures and is at least 3 inches below the high-high level of the AST.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Maximum working level” includes the normal fill level.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(13)">
          <text>“New” means the installation or construction of an AST, an AST system, or a secondary containment dike was complete on or after June 13, 2022.</text>
        </paragraph>
        <paragraph num="(14)">
          <text>Out-of-Service.</text>
          <paragraph num="(a)">
            <text>“Out-of-service” means an AST system in which the owner, the operator, and the person in charge of the AST system has:</text>
            <paragraph num="(i)">
              <text>Emptied the AST system of all oil and sludge; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Designated the AST system as out-of-service in accordance with Regulation .12 of this chapter.</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>“Out-of-service” includes a change-in-service in which an AST system is emptied of all oil and sludge in order to store a non-oil product.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(15)">
          <text>“Overfill” means an occurrence when an AST is filled beyond its critical high level and may result in a spill, release, or discharge of oil.</text>
        </paragraph>
        <paragraph num="(16)">
          <text>Repair.</text>
          <paragraph num="(a)">
            <text>“Repair” means work necessary to maintain or restore an AST system to a safe operating condition using industry approved standards.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Repair” may include</text>
            <paragraph num="(i)">
              <text>Removing and replacing the roof, shell, or bottom material to maintain AST integrity or ancillary AST equipment;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Re-leveling of an AST’s shell, bottom, or roof;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Adding or replacing reinforcing plates to existing shell penetrations; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Correcting flaws, such as tears or gouges, by grinding or gouging followed by welding.</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(17)">
          <text>Secondary Containment Dike.</text>
          <paragraph num="(a)">
            <text>“Secondary containment dike” means a secondary containment system that confines a spill, release, or discharge of oil from an AST or piping within the secondary containment system.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“Secondary containment dike” includes diking and a dike.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(18)">
          <text>“Storage tank strapping record” means a current, up-to-date storage tank record for a field-erected AST that:</text>
          <paragraph num="(a)">
            <text>Is developed by an owner, an operator, and a person in charge of an AST system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Identifies, by calculations, the following levels of concern:</text>
            <paragraph num="(i)">
              <text>Maximum working level;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>High-high level; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Critical high level.</text>
            </paragraph>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".03" heading="General Requirements.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of a new or relocated AST system with a field-erected AST shall ensure that the AST system meets the requirements of this chapter.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Unless otherwise specified in this chapter, an owner, an operator, and a person in charge of an existing AST system with a field-erected AST shall ensure the AST system meets the requirements of this chapter not later than:</text>
        <paragraph num="(1)">
          <text>2 years after June 13, 2022; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Another time period approved by the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall comply with the following permit, license, or approval requirements, when applicable:</text>
        <paragraph num="(1)">
          <text>Obtain an Individual Oil Operations Permit or comply with the General Oil Operations Permit conditions, in accordance with COMAR 26.10.01.09;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Obtain a State discharge permit or National Pollution Discharge Elimination System permit, in accordance with COMAR 26.08.04;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Obtain an Oil Transfer License, in accordance with COMAR 26.10.01.08;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Obtain an Air Quality Permit to Construct, in accordance with COMAR 26.11.02;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Obtain a State Air Quality Permit to Operate, in accordance with COMAR 26.11.02; and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Comply with any other applicable federal, State, or local government permit, license, or approval requirements.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Notwithstanding the compliance schedule in §B of this regulation, an owner, an operator, and a person in charge of an AST system with a field-erected AST shall register and maintain up-to-date registration of the AST system with the Department in accordance with the procedures and schedule in COMAR 26.10.01.10.</text>
      </paragraph>
      <paragraph num="E.">
        <text>Wetlands and Waterways. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Prior to installing a new or replacement AST system or secondary containment dike, obtain any applicable wetland and waterways authorization stated in COMAR 26.10.01.04E; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If installing the AST system in a location subject to flooding, protect the field-erected AST from flotation by anchoring the storage tank in accordance with NFPA 30A “Code for Motor Fuel Dispensing Facilities and Repair Garages”.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".04" heading="Performance Standards for a Field-Erected AST System.">
      <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
      <paragraph num="A.">
        <text>Ensure the field-erected AST is:</text>
        <paragraph num="(1)">
          <text>Properly designed for the oil storage application and type of oil to be stored;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Constructed of welded carbon steel or stainless steel; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Constructed to an industry standard, including an API standard for field-erected ASTs incorporated by reference in COMAR 26.10.01.03;</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Ensure the foundation of the field-erected AST:</text>
        <paragraph num="(1)">
          <text>Is designed and constructed in accordance with Annexes B and I of API Standard 650 “Welded Tanks for Oil Storage” to prevent settlement of the foundation and the AST due to soil bearing capacity and other site conditions using:</text>
          <paragraph num="(a)">
            <text>Field and laboratory testing; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Analyses and other sound engineering practices performed by a professional engineer;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Is capable of supporting the load of the AST and its contents without excessive differential settlement; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Provides positive drainage of water away from the AST base; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Test a new, repaired, or relocated AST system for tightness in accordance with NFPA 30 “Flammable and Combustible Liquids Code”:</text>
        <paragraph num="(1)">
          <text>Upon completion of the installation or repair of the AST system; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Before placing the AST system in-service</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".05" heading="Performance Standards for Piping.">
      <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
      <paragraph num="A.">
        <text>If installing or relocating a field-erected AST on or after June 13, 2022, install piping that does not penetrate a secondary containment dike, unless otherwise approved by the Department;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Ensure an existing field-erected AST meets the following requirements:</text>
        <paragraph num="(1)">
          <text>For piping connected to an AST penetrating a secondary containment dike:</text>
          <paragraph num="(a)">
            <text>Obtain approval of the Department to leave the piping in place; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Properly abandon and replace the piping not later than 1 year after June 13, 2022 with piping that does not penetrate the secondary containment dike; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>For underground piping connected to an AST, ensure the piping complies with the underground piping requirements in §E of this regulation not later than 1 year after June 13, 2022;</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Ensure an aboveground piping system connected to a field-erected AST is:</text>
        <paragraph num="(1)">
          <text>Constructed of carbon steel, alloy steel, or stainless steel piping;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Compatible with the type of oil being transferred;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Designed and constructed in accordance with industry recognized standards;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Liquid tight;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Properly supported by permanent bracing to prevent structural weaknesses; and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Protected against physical damage;</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Ensure a piping system installed aboveground or inside of a building is not constructed with:</text>
        <paragraph num="(1)">
          <text>Low melting point materials, such as aluminum, copper, or brass;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Materials that soften on fire exposure, such as plastics; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Non-ductile materials, such as cast iron; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>If installing an underground piping system, comply with the following requirements:</text>
        <paragraph num="(1)">
          <text>Install the piping system, including containment sumps, in accordance with the performance standards in COMAR 26.10.03.02 and .03A(3);</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Installation of the piping system is performed in the continuous on-site presence and under the direction of a certified UST system technician, as required under COMAR 26.10.02.03D;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Test the piping system for tightness in accordance with COMAR 26.10.03.05 and 26.10.05.02D;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Test the containment sumps for tightness in accordance with COMAR 26.10.03.03A(3);</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Provide a method of leak detection in accordance with COMAR 26.10.05.02D;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Maintain the containment sumps clean and free of liquid; and</text>
        </paragraph>
        <paragraph num="(7)">
          <text>If a test for tightness conducted in accordance with §E(3) or (4) of this regulation results in a failed test result or a leak is found:</text>
          <paragraph num="(a)">
            <text>Report the failed test result to the Department within 2 hours in accordance with COMAR 26.10.08.01; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Follow the investigation and confirmation procedures in 26.10.08.03, including making repairs and retesting the piping system and containment sumps for tightness.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".06" heading="Secondary Containment.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall surround the AST system with a continuous secondary containment dike that meets the requirements of this regulation.</text>
      </paragraph>
      <paragraph num="B.">
        <text>Compliance Schedule.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST that has a new secondary containment dike shall meet the requirements in §§C—H of this regulation upon installation of the secondary containment dike.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Unless otherwise provided in this regulation, an owner, an operator, and a person in charge of an AST system with a field-erected AST that has an existing secondary containment dike shall meet the requirements in §§C—H of this regulation not later than:</text>
          <paragraph num="(a)">
            <text>2 years after June 13, 2022; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Another time period approved by the Department.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall ensure a secondary containment dike:</text>
        <paragraph num="(1)">
          <text>Can contain a spill, release, or discharge from an AST and connected piping within the secondary containment dike surrounding the AST until the spill, release, or discharge is detected and removed;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Is designed by a professional engineer;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Is approved by the Department;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Is designed with consideration given to the soil and groundwater conditions at the oil storage facility or oil handling facility;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Prevents movement of oil into, near, or in an area likely to pollute waters of the State;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Provides safe ingress and egress for an individual;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Prevents water accumulation at an AST foundation;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>If the secondary containment dike surrounds two or more ASTs, is subdivided in accordance with NFPA 30 “Flammable and Combustible Liquids Code”;</text>
        </paragraph>
        <paragraph num="(9)">
          <text>If a secondary containment dike for an AST is exposed to precipitation, is designed and constructed to effectively hold 110 percent of the maximum capacity of the largest AST in the area enclosed by the secondary containment dike; and</text>
        </paragraph>
        <paragraph num="(10)">
          <text>Is constructed so that the secondary containment dike, upon testing, meets one of the following permeability criteria:</text>
          <paragraph num="(a)">
            <text>A permeability of less than 10-4 centimeters per second; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A product level drop rate of less than 1 centimeter per 3 hours.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Within 90 days of conducting a permeability test on a secondary containment dike or another time period approved by the Department, an owner, an operator, and a person in charge of an AST system with a field-erected AST shall repair or replace a secondary containment dike that does not meet the permeability criteria listed in §C(10) of this regulation.</text>
      </paragraph>
      <paragraph num="E.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST that has an earthen secondary containment dike shall conduct permeability testing on the earthen secondary containment dike according to the following requirements:</text>
        <paragraph num="(1)">
          <text>For an existing earthen secondary containment dike that has not been previously tested for permeability, test the existing earthen secondary containment dike for permeability using an industry standard approved by the Department not later than 1 year after June 13, 2022;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Test a new earthen secondary containment dike for permeability using an industry standard approved by the Department upon completing the construction of the earthen secondary containment dike and prior to placing the AST in-service; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Submit the results of the permeability testing to the Department not later than 60 days after the test.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall maintain written verification that a secondary containment dike meets the requirements in §§C—E of this regulation in accordance with Regulation .13 of this chapter.</text>
      </paragraph>
      <paragraph num="G.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall ensure a drain valve installed in a secondary containment dike is:</text>
        <paragraph num="(1)">
          <text>Not a flapper-type valve; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Except when being used to drain trapped water in accordance with §H of this regulation, kept completely closed and locked at all times.</text>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>When draining trapped water from a secondary containment dike, an owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Ensure the drainage leaving the secondary containment dike does not have any visible evidence of oil sheen;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Designate an individual to supervise, monitor, and document each drainage event from the secondary containment dike;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Keep a log that includes the following information for each secondary containment dike drainage event:</text>
          <paragraph num="(a)">
            <text>The name of employee supervising, monitoring, and documenting the drainage event;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The date of the discharge event;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The time discharge event started and ended;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The estimated volume of water drained; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>A description of the water quality, such as the presence of an oil sheen; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Maintain the log required by §H(3) of this regulation in accordance with Regulation .13 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall maintain a secondary containment dike clear and free of:</text>
        <paragraph num="(1)">
          <text>Vegetation; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Flammable and combustible materials, including oil.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".07" heading="Spill and Overfill Prevention.">
      <paragraph num="A.">
        <text>To prevent a spill, release, or discharge of oil due to an overfill of a field-erected AST, an owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Establish written procedures for filling the AST and maintain the procedures at the oil storage facility or oil handling facility;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Ensure the AST is:</text>
          <paragraph num="(a)">
            <text>Normally filled to a level that does not exceed the maximum working level of the AST;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>If filled to or in excess of the high-high level, emptied to the maximum working level as soon as practical; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Never filled to the critical high level; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Install, operate, inspect, maintain, and test overfill prevention equipment in accordance with:</text>
          <paragraph num="(a)">
            <text>The requirements of this regulation and Regulation .11 of this chapter;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>NFPA 30 “Flammable and Combustible Liquids Code”; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>If an oil storage facility meets the conditions in §H of this regulation, ANSI/API Standard 2350 “Overfill Prevention for Storage Tanks in Petroleum Facilities”.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST may not use overfill prevention equipment:</text>
        <paragraph num="(1)">
          <text>To control AST filling operations at an oil storage facility or oil handling facility; or</text>
        </paragraph>
        <paragraph num="(2)">
          <text>That restricts or interferes with the functioning of the AST’s normal or emergency vent.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>In accordance with COMAR 26.10.08.04, an owner, an operator, and a person in charge of an AST system with a field-erected AST and a responsible party shall:</text>
        <paragraph num="(1)">
          <text>Report and investigate a spill, release, or discharge from the AST system or an overfill; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Remediate the spill, release, or discharge or the overfill.</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Delivery and Transfer Operations. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Confirm that the ullage available in the AST is greater than the volume of oil to be transferred to the AST before a delivery or transfer begins;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>During a delivery or transfer operation, ensure:</text>
          <paragraph num="(a)">
            <text>A spill, release, or discharge of oil does not occur due to overfilling the AST or spilling oil during the transfer; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The delivery or transfer operation is constantly monitored to prevent overfilling of the AST and spilling of oil;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Ensure the delivery or transfer operation is conducted in accordance with the requirements in COMAR 26.10.01.16—.18 and NFPA 385 “Standard for Tank Vehicles for Flammable and Combustible Liquids”; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>If the delivery is by truck tank or transport with a cargo tank capacity of 500 gallons or greater, confirm the company making an oil delivery or transfer holds a valid Individual Oil Operations Permit from the Department in accordance with COMAR 26.10.01.09.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Liquid Level Measurements. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Gauge the liquid level and record the measurements in writing before filling the AST; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Maintain the records required under §E(1) of this regulation in accordance with Regulation .13 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>Tank Gauge. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Equip the field-erected AST with a tank gauge or other equivalent monitoring device that is:</text>
          <paragraph num="(a)">
            <text>Directly visible during a transfer operation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Accurately measures the level or quantity of oil in the AST;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Independent of any overfill prevention equipment; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Maintained in working order;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Install and maintain the tank gauge or other equivalent monitoring device in accordance with manufacture’s specifications; and</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Inspect and calibrate the tank gauge or other equivalent monitoring device at least once per year.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>Overfill Prevention Equipment. Except as provided in §H of this regulation, an owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Install the following overfill prevention equipment on the AST:</text>
          <paragraph num="(a)">
            <text>A high-high level alarm that:</text>
            <paragraph num="(i)">
              <text>Has a test function to allow the operability of the device to be confirmed prior to each delivery or transfer of oil;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Consists of a visual alarm and an audible alarm that alerts an individual involved in the oil delivery or transfer; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Goes into alarm when the liquid level reaches the high-high level of the AST established in §G(2) of this regulation and upon the failure or malfunction of the device; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>An automatic shut-off device that:</text>
            <paragraph num="(i)">
              <text>Has a test function to allow the operability of the device to be confirmed prior to each delivery or transfer of oil;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Automatically shuts off the flow of oil into an AST when the liquid level reaches the automatic shut off level of the AST established in §G(2) of this regulation; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Is equipped with a fail-safe mechanism that will trigger an alarm and shut off the flow of oil into an AST in the event of a device failure or malfunction;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Set the levels at which the overfill prevention equipment activates as follows:</text>
          <paragraph num="(a)">
            <text>For a field-erected AST with a capacity of less than 200,000 gallons:</text>
            <paragraph num="(i)">
              <text>The high-high level may not be greater than 90 percent of the critical high level of the AST; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The automatic shut off level may not be greater than 95 percent of the critical high level of the AST;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>For a field-erected AST with a capacity of 200,000 gallons or greater but less than 1,000,000 gallons:</text>
            <paragraph num="(i)">
              <text>The high-high level may not be greater than 95 percent of the critical high level of the AST; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The automatic shut off level may not be greater than 98 percent of the critical high level of the AST; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>For a field-erected AST with a capacity of 1,000,000 gallons or greater:</text>
            <paragraph num="(i)">
              <text>The high-high level may not be less than 6 inches below the critical high level of the AST; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The automatic shut off level may not be less than 3 inches below the critical high level of the AST;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>At least monthly, inspect and perform maintenance of overfill protection equipment in accordance with the manufacturer’s instructions; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>At least annually, perform functional testing of overfill protection equipment in accordance with the manufacturer’s instructions.</text>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>Overfill Prevention System.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of the following AST systems with a field-erected AST shall comply with the requirements of this section:</text>
          <paragraph num="(a)">
            <text>An AST system that receives Class I liquids or Class II liquids by interstate pipeline, intrastate pipeline, or marine vessel transfers; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An AST system that is otherwise subject to the requirements of ANSI/API Standard 2350 “Overfill Prevention for Storage Tanks in Petroleum Facilities”.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>In accordance with ANSI/API Standard 2350 “Overfill Prevention for Storage Tanks in Petroleum Facilities”, an owner, an operator, and a person in charge of a AST system with a field-erected AST listed in §H(1) of this regulation shall create and implement a comprehensive overfill prevention system that incorporates the following components:</text>
          <paragraph num="(a)">
            <text>A documented management system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A risk assessment for each AST subject to an overfill;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Defined operational parameters, including levels of concern within the AST, response times, and periodic reviews of the levels of concern and response times;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Written procedures for:</text>
            <paragraph num="(i)">
              <text>Receiving and terminating transfers;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Emergencies and abnormal conditions;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Training personnel on the overfill prevention system;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Testing, inspecting, and maintaining overfill prevention equipment and associated training of personnel; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Maintenance of records, including records for testing and maintenance of overfill prevention equipment, storage tank alarm history, actuation of overfill prevention equipment, and overfills; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(e)">
            <text>The physical overfill prevention equipment.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="I.">
        <text>Labeling. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Provide the following labeling on the AST system:</text>
          <paragraph num="(a)">
            <text>The storage capacity of the AST in gallons;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The type of oil stored or last stored in the AST prior to being placed out-of-service;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A proper NFPA 704 “Standard System for the Identification of the Hazards of Materials for Emergency Response” placard; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>If the AST system was placed out-of-service in accordance with Regulation .12 of this chapter, the words “OUT-OF-SERVICE” or “EMPTY”; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Permanently and clearly mark the field-erected AST with the information listed in §I(1) of this regulation on, not less than two sides of the AST and in locations that are highly visible to employees of the oil storage facility or oil handling facility, contractors, government representatives, and emergency response personnel.</text>
        </paragraph>
      </paragraph>
      <paragraph num="J.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall maintain records related to spill and overfill prevention measures required under this regulation in accordance with Regulation .13 of this chapter.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".08" heading="Release Detection.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall provide a method or combination of release detection methods that detect a spill, release, or discharge from the AST system through:</text>
        <paragraph num="(1)">
          <text>Visual inspections of the AST system in accordance with Regulation .11 of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>A continuous electronic release detection system; or</text>
        </paragraph>
        <paragraph num="(3)">
          <text>A continuous mechanical release detection system.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST using a continuous electronic or mechanical release detection system shall:</text>
        <paragraph num="(1)">
          <text>Install, calibrate, operate, and maintain the release detection system in accordance with the manufacturer’s instructions; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>At least annually:</text>
          <paragraph num="(a)">
            <text>Perform routine maintenance on the release detection system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Check the release detection system for operability at scheduled service checks; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Per the manufacturer’s specifications, inspect, field-test, or calibrate the release detection system to verify that the selected release detection method is being maintained and operated properly to detect a spill, release, or discharge.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall monitor underground piping connected to the AST for spill, releases, and discharges in accordance with COMAR 26.10.05.02D.</text>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".09" heading="Corrosion Protection.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST that has a capacity less than 10,000 gallons shall install an elevated AST so that the storage tank is not in direct contact with soil or another material that may allow moisture penetration or corrosion.</text>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST that has a capacity of 10,000 gallons or greater, is not an elevated AST, and in direct contact with soil or another material that may allow moisture penetration or corrosion shall:</text>
        <paragraph num="(1)">
          <text>Provide one of the following cathodic protection systems:</text>
          <paragraph num="(a)">
            <text>An impressed current system;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A galvanic system; or</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Subject to the approval of the Department, an alternative method of corrosion protection that is:</text>
            <paragraph num="(i)">
              <text>Designed to prevent a spill, release, or discharge of oil or a threatened spill, release, or discharge of oil in a manner determined by the Department to be not less protective of human health and the environment than the methods in §B(1)(a) and (b) of this regulation; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Approved by a corrosion expert; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Provide a cathodic protection system that is:</text>
          <paragraph num="(a)">
            <text>Designed by a corrosion expert;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Designed and tested, at a minimum, in accordance with the following industry standards and recommended practices:</text>
            <paragraph num="(i)">
              <text>NACE SP0169-2013 “Control of External Corrosion on Underground or Submerged Metallic Piping Systems”;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>NACE SP0193-2016 “Application of Cathodic Protection to Control External Corrosion of Carbon Steel On-Grade Storage Tank Bottoms”;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>NACE TM0497-2018 “Measurement Techniques Related to Criteria for Cathodic Protection on Underground or Submerged Metallic Piping Systems”; and</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>API Recommended Practice 651 “Cathodic Protection of Aboveground Petroleum Storage Tanks”;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Designed and installed to provide continuous corrosion protection to the external portion of the AST and other metal components of the AST system in contact with soil or other materials that may allow corrosion;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Installed with easily identifiable test stations, access points, or other methods to monitor the operation and functionality of the cathodic protection system; and</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Continuously operated and maintained for the in-service and out-of-service life of the AST system.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Impressed Current System. An owner, an operator, and a person in charge of an AST system with a field-erected AST protected by an impressed current system shall:</text>
        <paragraph num="(1)">
          <text>Install, operate, maintain, inspect, and test the impressed current system in accordance with the requirements of this section;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Ensure the impressed current source is not de-energized at any time except to perform service work on the AST system;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Ensure the impressed current source is equipped with a continuously operating meter that displays the voltage, amperage, and operating (run) time;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>At least once every 60 days:</text>
          <paragraph num="(a)">
            <text>Inspect the impressed current system to ensure the cathodic protection system is functioning properly by:</text>
            <paragraph num="(i)">
              <text>Verifying the power to the impressed current system is on; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Recording the voltage, amperage, and operating time; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Record and maintain the inspection results in accordance with Regulation .13 of this chapter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>At least annually:</text>
          <paragraph num="(a)">
            <text>Have a cathodic protection tester inspect and test:</text>
            <paragraph num="(i)">
              <text>The impressed current system for electrical shorts, ground connections, meter accuracy, and circuit resistance; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The condition of the impressed current system’s isolating devices, continuity bonds, and insulators; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Record and maintain the results of the inspection and test in accordance with Regulation .13 of this chapter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>Have a corrosion expert inspect the impressed current system in accordance with an industry standard or recommended practice listed in §B(2) of this regulation:</text>
          <paragraph num="(a)">
            <text>When the impressed current system is 5 years of age; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Every 5 years thereafter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(7)">
          <text>Provide a completed report for an inspection performed pursuant to §C(6) of this regulation to the Department and maintain a copy of the report in accordance with Regulation .13 of this chapter;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Except as provided in §C(9) of this regulation, if the protection provided by an impressed current system is determined to be inadequate to properly protect the AST system:</text>
          <paragraph num="(a)">
            <text>Employ a corrosion expert to determine the cause of the inadequacy within 30 days of the discovery; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Either:</text>
            <paragraph num="(i)">
              <text>Complete repairs of the impressed current system within 60 days of the discovery or on a schedule approved by the Department; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If repairs cannot return the impressed current system to adequate performance, replace the impressed current system within 120 days of the discovery or on a schedule approved by the Department; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(9)">
          <text>If an impressed current system determined to be inadequate to provide proper protection to the AST system cannot be repaired or replaced in accordance with §C(8) of this regulation:</text>
          <paragraph num="(a)">
            <text>Empty all oil in contact with the portion of the AST system inadequately protected by the impressed current system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Place the AST system out-of-service in accordance with Regulation .13 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Galvanic System. An owner, an operator, and a person in charge of an AST system with a field-erected AST protected by a galvanic system shall:</text>
        <paragraph num="(1)">
          <text>Install, operate, maintain, inspect, and test the galvanic system in accordance with the requirements of this section;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Comply with the following inspection and test requirements:</text>
          <paragraph num="(a)">
            <text>A cathodic protection tester shall inspect and test the galvanic system in accordance with an industry standard or recommended practice listed in §B(2) of this regulation:</text>
            <paragraph num="(i)">
              <text>Within 6 months of installing the galvanic system; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>At least annually thereafter;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>A cathodic protection tester conducting an annual inspection shall make and record a sufficient number of AST-to-soil and underground piping-to-soil potential measurements to determine if the AST system is completely protected in accordance with an industry standard or recommended practice listed in §B(2) of this regulation; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Maintain records of the AST-to-soil and underground piping-to-soil potential measurements in accordance with Regulation .13 of this chapter;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Except as provided under §D(4) of this regulation, if the protection provided by a galvanic system is determined to be inadequate to properly protect the AST system:</text>
          <paragraph num="(a)">
            <text>Employ a corrosion expert to determine the cause of the inadequacy within 30 days of the discovery; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Either:</text>
            <paragraph num="(i)">
              <text>Complete repairs of the galvanic system within 60 days of the discovery or on a schedule approved by the Department; or</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>If repairs cannot return the galvanic system to adequate performance, replace the galvanic system within 120 days of the discovery or on a schedule approved by the Department; and</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>If a galvanic system determined to be inadequate to provide proper protection to the AST system cannot be repaired or replaced in accordance with §D(3) of this regulation:</text>
          <paragraph num="(a)">
            <text>Empty all oil in contact with the portion of the AST system inadequately protected by the galvanic system; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Place the AST system out-of-service in accordance with Regulation .12 of this chapter.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".10" heading="Normal and Emergency Venting.">
      <paragraph num="A.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall ensure the normal venting for the field-erected AST meets the following requirements:</text>
        <paragraph num="(1)">
          <text>Design and construct normal venting in accordance with the following industry standards:</text>
          <paragraph num="(a)">
            <text>NFPA 30 “Flammable and Combustible Liquids Code”; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An API standard applicable to field-erected ASTs incorporated by reference in COMAR 26.10.01.03; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Vent an atmospheric pressure AST to prevent the development of vacuum or pressure above a 1.0 psi (6.9 kPa) maximum operating pressure.</text>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall ensure the emergency venting for the field-erected AST meets the following requirements:</text>
        <paragraph num="(1)">
          <text>Design and construct emergency venting in accordance with the following industry standards:</text>
          <paragraph num="(a)">
            <text>NFPA 30 “Flammable and Combustible Liquids”; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>API Standard 2000 “Venting Atmospheric and Low-pressure Storage Tanks”; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>The field-erected AST has one of the following emergency relief venting designs:</text>
          <paragraph num="(a)">
            <text>A floating roof;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A lifter roof;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>A weak roof-to-shell seam; or</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Another industry approved pressure-relieving device.</text>
          </paragraph>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".11" heading="Inspection Requirements for an AST System.">
      <paragraph num="A.">
        <text>Definitions.</text>
        <paragraph num="(1)">
          <text>In this regulation, the following terms have the meanings stated.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Terms Defined.</text>
          <paragraph num="(a)">
            <text>“Remaining corrosion allowance” or “RCA” means the difference between the measured shell thickness and the minimum required thickness of an AST, measured in millimeters.</text>
          </paragraph>
          <paragraph num="(b)">
            <text>“N” means the shell corrosion rate of an AST, measured in millimeters per year.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Periodic Visual Inspections.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall conduct periodic visual inspections in accordance with:</text>
          <paragraph num="(a)">
            <text>The inspection procedures under §B(2) or (3) of this regulation; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The recordkeeping requirements under §B(4) and (5) of this regulation.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST may meet the visual inspections requirement in §B(1) of this regulation by, at a minimum:</text>
          <paragraph num="(a)">
            <text>Inspecting for the following conditions monthly:</text>
            <paragraph num="(i)">
              <text>Signs of spills, releases, or discharges from any portion of the AST system;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Water in the secondary containment dike and AST or, if a double-walled AST, the primary storage tank and interstice;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>The condition of the secondary containment dike, including drain valves;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>Signs of shell distortion;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>Signs of settlement;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Signs of corrosion;</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>The condition of the AST foundation or supports;</text>
            </paragraph>
            <paragraph num="(viii)">
              <text>The condition of the exterior coating of the AST system;</text>
            </paragraph>
            <paragraph num="(ix)">
              <text>The condition of seams, rivets, and nozzle connections;</text>
            </paragraph>
            <paragraph num="(x)">
              <text>The condition of valves, pumps, piping, and other appurtenances directly connected to the AST;</text>
            </paragraph>
            <paragraph num="(xi)">
              <text>The condition of the tank gauge or an equivalent monitoring device;</text>
            </paragraph>
            <paragraph num="(xii)">
              <text>The condition of release detection systems; and</text>
            </paragraph>
            <paragraph num="(xiii)">
              <text>The condition of overfill protection equipment;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Inspecting containment sumps associated with an underground piping system monthly by:</text>
            <paragraph num="(i)">
              <text>Checking for evidence of a spill, release or discharge; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Removing any liquid or debris; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Removing any water found during the monthly inspection from the secondary containment dike and AST or, if a double-bottomed AST, the primary storage tank and interstice.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST may meet the periodic visual inspections requirement in §B(1) of this regulation by conducting periodic AST inspections in accordance with:</text>
          <paragraph num="(a)">
            <text>STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks” if the AST does not exceed:</text>
            <paragraph num="(i)">
              <text>30 feet in diameter; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>40 feet in height; or</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>Tank In-service Inspection Checklist in Annex C of API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction”.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall maintain the following records related to periodic visual inspections:</text>
          <paragraph num="(a)">
            <text>If the AST system was inspected in accordance with §B(2) of this regulation, a written log or electronic record that includes:</text>
            <paragraph num="(i)">
              <text>The date of the inspection;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The name and title of the individual performing the inspection;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>A description of each deficiency found;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The name and title of the individual notified of the deficiencies found; and</text>
            </paragraph>
            <paragraph num="(v)">
              <text>A record of how and when the deficiencies were corrected; and</text>
            </paragraph>
          </paragraph>
          <paragraph num="(b)">
            <text>If the AST system was inspected in accordance with §B(3) of this regulation, the completed monthly and annual inspection checklists in STI/SPFA SP001 “Standard for the Inspection of Aboveground Storage Tanks”.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall maintain the records required in §B(4) of this regulation in accordance with Regulation .13 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall conduct corrosion protection system inspections in accordance with Regulation .10 of this chapter.</text>
      </paragraph>
      <paragraph num="D.">
        <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Inspect and clean normal and emergency vents for the field-erected AST annually; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Maintain records of the vent inspection and cleaning required in §D(1) of this regulation in accordance with Regulation .13 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Ultrasonic Thickness Inspections. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall use ultrasonic thickness measurements of the external AST shell to determine shell integrity according to the following requirements:</text>
        <paragraph num="(1)">
          <text>If the corrosion rate is unknown for a field-erected AST, complete an initial ultrasonic thickness inspection not later than 2 years after June 13, 2022;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Perform ultrasonic thickness inspections at the lesser of the following intervals:</text>
          <paragraph num="(a)">
            <text>RCA/2N years; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>15 years;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Include the following information in the inspection records for each ultrasonic thickness inspection performed on an AST:</text>
          <paragraph num="(a)">
            <text>The date of the inspection;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The name and title of individual performing the inspection; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The ultrasonic thickness measurements; and</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>Maintain the records for ultrasonic thickness inspections required under §E(3) of the regulation in accordance with Regulation .13 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="F.">
        <text>External Inspections. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall have an external inspection performed on the field-erected AST according to the following requirements:</text>
        <paragraph num="(1)">
          <text>An authorized inspector conducts external inspection on the field-erected AST.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Perform external inspections at the lesser of the following intervals:</text>
          <paragraph num="(a)">
            <text>RCA/4N years; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>5 years;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Inspect the following components of a field-erected AST during an external inspection:</text>
          <paragraph num="(a)">
            <text>The AST foundation;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The shell and roof of the AST, including shell and roof appurtenances;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The AST accessways;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The AST grounding system;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>The wall and roof of an AST having an insulated covering;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Connected aboveground piping; and</text>
          </paragraph>
          <paragraph num="(g)">
            <text>The secondary containment dike;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(4)">
          <text>At a minimum, the authorized inspector conducting an external inspection of the field-erected AST shall complete the Tank In-service Inspection Checklist in Annex C of API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction”;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Submit a copy of the final external inspection report to the Department within 60 days of completing the external inspection; and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Maintain records of completed external inspections in accordance with Regulation .13 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="G.">
        <text>Risk-based Inspection Program.</text>
        <paragraph num="(1)">
          <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST may implement a risk-based inspection program to develop an inspection plan for conducting internal inspections on the field-constructed AST.</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If implementing a risk-based inspection program, an owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
          <paragraph num="(a)">
            <text>Establish and implement the risk-based inspection program in accordance with API Recommended Practice 580 “Risk-based Inspection”;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Prior to implementation, have the risk-based inspection program, including the risk-based inspection assessment and inspection plan, reviewed and approved by an authorized inspector and a storage tank engineer.</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall maintain records related to the risk-based inspection program, including copies of the risk-based inspection assessment, inspection plan, and authorized inspector and storage tank engineer approvals, in accordance with the recordkeeping requirements in Regulation .13 of this chapter.</text>
        </paragraph>
      </paragraph>
      <paragraph num="H.">
        <text>Internal Inspections. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall have an internal inspection of a field-erected AST performed on the field-erected AST according to the following requirements:</text>
        <paragraph num="(1)">
          <text>An authorized inspector shall complete an internal inspection of a field-erected AST;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Complete an initial internal inspection on a new field-erected AST not later than:</text>
          <paragraph num="(a)">
            <text>10 years from the date the AST first contained oil; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A maximum inspection interval established in accordance with API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction” if the following conditions are met:</text>
            <paragraph num="(i)">
              <text>The maximum interval is determined under a risk-based inspection program; and</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>The AST has one or more of the leak prevention, detection, corrosion mitigation, or containment safeguards listed in Table 6.1–Tank Safeguard in API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction”;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>Complete an initial internal inspection on an existing field-erected AST that contains oil not later than 2 years after June 13, 2022;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Complete subsequent internal inspections on a new or existing field-erected AST not later than:</text>
          <paragraph num="(a)">
            <text>20 years after the date the initial internal inspection required in §H(2) or (3) of this regulation was completed; or</text>
          </paragraph>
          <paragraph num="(b)">
            <text>A maximum inspection interval determined in accordance with the corrosion rate procedures and the additional risk-based inspection requirements in API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction”;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>An internal inspection of a field-erected AST includes:</text>
          <paragraph num="(a)">
            <text>An evaluation of, at a minimum, 75 percent of the storage tank bottom plates using magnetic flux leakage scanning;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>An evaluation of 100 percent of floor plate welds and shell-to-floor welds using one or more of the following testing methods:</text>
            <paragraph num="(i)">
              <text>Vacuum box;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Magnetic particle; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Liquid penetrant;</text>
            </paragraph>
          </paragraph>
          <paragraph num="(c)">
            <text>Verification of a storage tank bottom’s integrity to ensure the storage tank bottom is not severely corroded or there is evidence of a spill, release, or discharge;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>The collection of data necessary to assess the minimum storage tank bottom and shell thickness, including evaluating data from previous inspections;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Identification and evaluation of any storage tank bottom settlement; and</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Assessment of all external and internal aspects of an AST while the storage tank is out-of-service, including an examination and test of the following AST components:</text>
            <paragraph num="(i)">
              <text>Storage tank exterior and interior;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Storage tank bottom, including the liquid side and soil side;</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Shell seams, plates, and overflows;</text>
            </paragraph>
            <paragraph num="(iv)">
              <text>The fixed roof interior, including the surface, support structure, and appurtenances;</text>
            </paragraph>
            <paragraph num="(v)">
              <text>A floating roof, including the deck, pontoons, cutouts and supports, seal assemblies, and appurtenances;</text>
            </paragraph>
            <paragraph num="(vi)">
              <text>Common AST appurtenances; and</text>
            </paragraph>
            <paragraph num="(vii)">
              <text>Access structures;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(6)">
          <text>At a minimum, an authorized inspector conducting an internal inspection of an AST shall complete the Tank Out-of-service Inspection Checklist in Annex C of API Standard 653 “Tank Inspection, Repair, Alteration, and Reconstruction” in addition to other forms used;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Submit a copy of the final internal inspection report to the Department within 60 days of completing the internal inspection; and</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Maintain records of each internal inspection conducted for on a field-erected AST in accordance with Regulation .13 of this chapter.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".12" heading="Out-of-Service and Permanent Closure.">
      <paragraph num="A.">
        <text>Out-of-Service. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall complete each of the following steps to place the AST system out-of-service:</text>
        <paragraph num="(1)">
          <text>Notify the Department in writing 30 days before placing the AST system out-of-service;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Remove all oil from the AST system;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Isolate all piping connected to the AST;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Remove all waste materials from the AST system, including storage tank-bottom sludge, and dispose of these materials in compliance with applicable federal, State, and local laws;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Purge all petroleum vapors and maintain the AST system vapor free;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Secure the AST system to prevent unauthorized entrance or tampering;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Protect the AST system from flotation;</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Continue the operation and maintenance of corrosion protection on the AST system in accordance with Regulation .09 of this chapter;</text>
        </paragraph>
        <paragraph num="(9)">
          <text>Lock the fill port; and</text>
        </paragraph>
        <paragraph num="(10)">
          <text>Label the AST using lettering at least 3 inches high, in a readily visible location on the AST, with the following information:</text>
          <paragraph num="(a)">
            <text>Date the AST system was placed out-of-service;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Name of product last stored; and</text>
          </paragraph>
          <paragraph num="(c)">
            <text>The words “OUT-OF-SERVICE” or “EMPTY”.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="B.">
        <text>Return to In-Service. An owner, an operator, and a person in charge of an out-of-service AST system with a field-erected AST shall complete the following steps prior to placing the AST system in-service:</text>
        <paragraph num="(1)">
          <text>Notify the Department in writing 30 days before placing the AST system in-service;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If an external or internal inspection required under Regulation .11 of this chapter was due to occur while the AST system was out of service, conduct the external or internal inspection of the AST system in accordance with the inspection procedures in Regulation .11F or H of this chapter.</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Test all connected piping and appurtenances to ensure a spill, release, or discharge will not occur; and</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Maintain a copy of all corrosion protection system and formal inspection and testing reports, including the findings of inspections and tests and repairs performed, and provide a copy to the Department upon request.</text>
        </paragraph>
      </paragraph>
      <paragraph num="C.">
        <text>Permanent Closure. An owner, an operator, and a person in charge of an AST system with a field-erected AST shall permanently close the AST system in accordance with the following requirements:</text>
        <paragraph num="(1)">
          <text>At least 30 days before permanently closing the AST system:</text>
          <paragraph num="(a)">
            <text>Notify the Department in writing of the planned AST system permanent closure; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Submit to the Department for approval a proposed sampling plan for a site assessment to determine if there is evidence of a spill, release, or discharge where contamination is most likely to be present, including sampling of, at a minimum, the following areas of the AST site:</text>
            <paragraph num="(i)">
              <text>Within and immediately outside of the secondary containment dike, if present;</text>
            </paragraph>
            <paragraph num="(ii)">
              <text>Within the footprint of the removed AST; and</text>
            </paragraph>
            <paragraph num="(iii)">
              <text>Beneath underground piping associated with the removed AST;</text>
            </paragraph>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Place the AST system out-of-service in accordance with §A of this regulation;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Disconnect and remove all aboveground piping associated with the AST system;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Disconnect and remove all underground piping associated with the AST system:</text>
          <paragraph num="(a)">
            <text>Under the continuous on-site presence and direction of a certified UST system technician or remover; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>In accordance with the procedures in COMAR 26.10.10.02D;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(5)">
          <text>Remove the AST and associated piping from the site; and</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Within 45 days of completing the permanent closure and approved site assessment, submit a closure report to the Department detailing:</text>
          <paragraph num="(a)">
            <text>The AST closure activities; and</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The results of the sampling event, including a map identifying sample locations, laboratory results, summary of findings, and conclusions.</text>
          </paragraph>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Change-in-Service. An owner, an operator, and a person in charge of an AST system with a field-erected AST placing the AST system out-of-service in order to store a non-oil product shall:</text>
        <paragraph num="(1)">
          <text>Notify the Department in writing at least 30 days before placing the AST system out-of-service; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Place the AST system out-of-service in accordance with the requirements of the Department.</text>
        </paragraph>
      </paragraph>
      <paragraph num="E.">
        <text>Upon completing an out-of-service activity specified §§A—D of this regulation, an owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
        <paragraph num="(1)">
          <text>Within 30 days, amend the AST system registration with the Department in accordance with COMAR 26.10.01.10; and</text>
        </paragraph>
        <paragraph num="(2)">
          <text>If the oil storage facility or oil handling facility is required under COMAR 26.10.01.09 to be operated under an Individual Oil Operation Permit, submit a request to modify the Individual Oil Operations Permit in accordance with COMAR 26.10.01.12.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <regulation prefix="Regulation" num=".13" heading="Recordkeeping.">
      <text>An owner, an operator, and a person in charge of an AST system with a field-erected AST shall:</text>
      <paragraph num="A.">
        <text>Maintain the records required under this chapter at the oil storage facility or oil handling facility, or another a readily accessible location;</text>
      </paragraph>
      <paragraph num="B.">
        <text>Provide the records to the Department upon request;</text>
      </paragraph>
      <paragraph num="C.">
        <text>Retain the following records for a minimum of 5 years:</text>
        <paragraph num="(1)">
          <text>Records of periodic visual inspections conducted in accordance with Regulation .11B of this chapter;</text>
        </paragraph>
        <paragraph num="(2)">
          <text>Records of annual normal and emergency vent inspections and cleaning conducted in accordance with Regulation .11D of this chapter;</text>
        </paragraph>
        <paragraph num="(3)">
          <text>Inventory control records;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>Overfill prevention equipment testing records;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Release detection records;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Secondary containment dike drainage logs;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Storage tank gauging device calibration records; and</text>
        </paragraph>
        <paragraph num="(8)">
          <text>Testing records for aboveground and underground piping; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="D.">
        <text>Retain the following AST system records for the operational life of an AST system and for at least 5 years after an AST system has been permanently closed in accordance with Regulation .12 of this chapter:</text>
        <paragraph num="(1)">
          <text>Construction records, including records of:</text>
          <paragraph num="(a)">
            <text>The AST name plate information;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>The original as-built specifications and drawings and any modifications made to the AST system during the operational life of the AST system;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Applicable manufacturer’s documentation for ancillary equipment;</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Tests conducted upon completing an installation or repair of an AST system component, including hydrostatic testing and pressure tightness testing;</text>
          </paragraph>
          <paragraph num="(e)">
            <text>Material tests and analyses, including secondary containment dike permeability tests;</text>
          </paragraph>
          <paragraph num="(f)">
            <text>Tank strapping record; and</text>
          </paragraph>
          <paragraph num="(g)">
            <text>The names of the companies performing construction activities and a description of the work performed;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(2)">
          <text>Cathodic protection system inspections records for impressed current and galvanic systems, including records of:</text>
          <paragraph num="(a)">
            <text>Cathodic protection system design description;</text>
          </paragraph>
          <paragraph num="(b)">
            <text>Inspection findings and conclusions;</text>
          </paragraph>
          <paragraph num="(c)">
            <text>Recommendations; and</text>
          </paragraph>
          <paragraph num="(d)">
            <text>Testing and repair records;</text>
          </paragraph>
        </paragraph>
        <paragraph num="(3)">
          <text>A complete copy of each final formal inspection report;</text>
        </paragraph>
        <paragraph num="(4)">
          <text>A complete copy of each ultrasonic thickness inspection report;</text>
        </paragraph>
        <paragraph num="(5)">
          <text>Records of AST system repairs and alteration history, including names of companies completing repair work;</text>
        </paragraph>
        <paragraph num="(6)">
          <text>Records of secondary containment dike testing and evaluation;</text>
        </paragraph>
        <paragraph num="(7)">
          <text>Records of spills, releases, and discharges and written reports of the occurrences required by COMAR 26.10.01.05E; and</text>
        </paragraph>
        <paragraph num="(8)">
          <text>A closure report for an AST system permanently closed in accordance with Regulation .12 of this chapter.</text>
        </paragraph>
      </paragraph>
    </regulation>
    <annotations>
      <annotation type="Authority">Environment Article, §§4-401—4-403, 4-405, 4-406, 4-408, 4-410—4-412, 4-415-1—4-418, 4-501, and 4-502, Annotated Code of Maryland</annotation>
      <annotation type="History" subtype="Administrative History">Effective date: June 13, 2022 (49:12 Md. R. 642)</annotation>
    </annotations>
  </chapter>