<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".04" citation="COMAR 26.11.06.04" title_num="26" subtitle_num="11" chapter_num="06" heading="Carbon Monoxide in Areas III and IV.">
  <paragraph num="A.">
    <text>Applicability and Exceptions.</text>
    <paragraph num="(1)">
      <text>This regulation is applicable only in Areas III and IV.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>This regulation applies to any person who owns or operates any installation that discharges carbon monoxide gas at a rate exceeding 500 pounds (227 kilograms) per day and at a concentration exceeding 12 percent by volume.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>This regulation does not apply to any person who owns or operates:</text>
      <paragraph num="(a)">
        <text>Coking process equipment used directly in the manufacture of metallurgical coke by the pyrolysis of coal in the absence of air;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Process equipment subject to COMAR 26.11.11.04B; or</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Installations subject to COMAR 26.11.10.06.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>A person is exempt from the requirements of this regulation if he demonstrates to the satisfaction of the Department that the:</text>
      <paragraph num="(a)">
        <text>Gas mixture containing the carbon monoxide will not support combustion due to the presence of noncombustible gases; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Carbon monoxide emissions will not cause or contribute to a violation of the National Ambient Air Quality Standard or Prevention of Significant Deterioration requirement for carbon monoxide.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>General Requirements.</text>
    <paragraph num="(1)">
      <text>A person may not cause or permit the discharge of carbon monoxide gas into the atmosphere from any installation unless it is burned in a direct flame afterburner with excess oxygen for at least 0.3 second at a temperature of at least 1,300°F.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>The direct flame afterburner shall be equipped with a properly functioning recording pyrometer located and positioned in the work area so that it is readily visible to the operator of the installation.</text>
    </paragraph>
  </paragraph>