<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".02" citation="COMAR 26.11.13.02" title_num="26" subtitle_num="11" chapter_num="13" heading="Applicability and Exemptions.">
  <paragraph num="A.">
    <text>A source which is subject to the provisions of this chapter is also subject to the provisions of any other chapter. However, when this chapter establishes an emission standard for a specific installation which differs from the general emission standard in COMAR 26.11.01—.09, this chapter takes precedence.</text>
  </paragraph>
  <paragraph num="B.">
    <text>This chapter applies throughout the State. The NSPS requirements under 40 CFR Part 60, Subpart K (effective June 11, 1973), Subpart Ka (effective May 18, 1978), Subpart Kb (effective July 23, 1984), and Subpart XX apply throughout the State.</text>
  </paragraph>
  <paragraph num="C.">
    <text>Exemptions for Large Storage Tanks.</text>
    <paragraph num="(1)">
      <text>A welded tank is exempt from the secondary seal requirements of Regulation .03B(2)(a) of this chapter if it contains gasoline or VOC with a TVP less than 4 psia (2.75 kilonewton/square meter) and has a primary seal.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>The secondary seal requirements under Regulation .03A(1)(b)(i) of this chapter do not apply if the storage tank is equipped with a liquid mounted seal.</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>The provisions of this chapter do not apply to the filling of a motor vehicle's fuel tank.</text>
  </paragraph>
  <paragraph num="E.">
    <text>If a source becomes subject to any requirement in this chapter because it exceeds a regulation applicability level, the source shall continue to be subject to all applicable requirements, regardless of whether future throughput is below the regulation threshold.</text>
  </paragraph>
</regulation>