<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".05" citation="COMAR 26.11.14.05" title_num="26" subtitle_num="11" chapter_num="14" heading="Monitoring and Reporting Requirements for Total Reduced Sulfur.">
  <paragraph num="A.">
    <text>TRS emissions from kraft pulp mill recovery boilers shall be monitored continuously, using Method 16B of the Department's Technical Memorandum 91-01, “Test Methods and Equipment Specifications for Stationary Sources” (January 1991), which is incorporated by reference in COMAR 26.11.01.04C.</text>
  </paragraph>
  <paragraph num="B.">
    <text>TRS emissions from smelt tanks will be sampled once a month using grab samples collected and analyzed using Method 16B of the Department's Technical Memorandum 91-01, “Test Methods and Equipment Specifications for Stationary Sources” (January 1991), which is incorporated by reference in COMAR 26.11.01.04C.</text>
  </paragraph>
  <paragraph num="C.">
    <text>Quarterly reports shall be submitted to the Department summarizing the monitoring data.</text>
  </paragraph>
</regulation>