<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".07-1" citation="COMAR 26.11.19.07-1" title_num="26" subtitle_num="11" chapter_num="19" heading="Control of VOC Emissions from Solid Resin Decorative Surface Manufacturing.">
  <paragraph num="A.">
    <text>Definitions. In this regulation, the following terms have the meanings indicated:</text>
    <paragraph num="(1)">
      <text>“Particle plant operation” means a SRDS operation where cured resin sheets are pulverized into particles to be used in the manufacture of decorative surfaces.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>“Related operations” means a VOC emitting installation located at a solid resin decorative surface manufacturing facility other than a particle plant operation, shaped goods plant, SRDS operation, or high pressure laminate (HPL) operation.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>“Shaped goods plant” means a process in which resins are mixed with a catalyst and other ingredients, shaped into a mold, and cured to produce a shaped product such as a sink.</text>
    </paragraph>
    <paragraph num="(4)">
      <text>“Solid resin decorative surface (SRDS) operation” means a process where resins are mixed with a catalyst and other ingredients, formed into a sheet, and cured.</text>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>Applicability. This regulation applies to a person who owns or operates a solid resin decorative surface manufacturing facility that is a major stationary source of VOC.</text>
  </paragraph>
  <paragraph num="C.">
    <text>General Requirements for SRDS Operations. A person who owns or operates an SRDS operation subject to this regulation shall:</text>
    <paragraph num="(1)">
      <text>Vent the curing oven exhaust at each SRDS operation into a VOC control system consisting of a condenser and carbon adsorber unit, or other control system that is maintained and operated to reduce VOC emissions from the curing oven exhaust by 75 percent or more; and</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Take all reasonable precautions to minimize VOC emissions from the SRDS operation mixing vessels and storage tanks including:</text>
      <paragraph num="(a)">
        <text>The use of covers on mixers to minimize evaporative losses except when adding or emptying materials,</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Operator training in procedures to minimize spills and evaporative losses during the mixing and transferring of VOC containing materials,</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Implementing programs to minimize the quantity of VOC-based materials used to clean lines or equipment,</text>
      </paragraph>
      <paragraph num="(d)">
        <text>Storing VOC-contaminated cloth or paper in closed containers, and</text>
      </paragraph>
      <paragraph num="(e)">
        <text>Implementing an effective leak inspection and maintenance program that includes monthly inspections of equipment such as storage tanks, process equipment, pumps, compressors, valves, flanges, and other pipe fittings for leaks.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>General Requirements for Particle Plant Operations. A person who owns or operates a particle plant operation subject to this regulation shall:</text>
    <paragraph num="(1)">
      <text>Vent the curing oven exhaust at each particle plant operation into a VOC control system consisting of a carbon adsorber unit or other control system that is maintained and operated to reduce VOC emissions from the curing oven exhaust by 75 percent or more; and</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Take all reasonable precautions to minimize VOC emissions from the particle plant operation mixing vessels and storage tanks as specified in §C(2) of this regulation for SRDS operations.</text>
    </paragraph>
  </paragraph>
  <paragraph num="E.">
    <text>General Requirements for Shaped Goods Plants. A person who owns or operates a shaped goods plant subject to this regulation shall take all reasonable precautions to minimize VOC emissions as specified in §C(2) of this regulation for SRDS operations.</text>
  </paragraph>
  <paragraph num="F.">
    <text>General Requirements For Related Operations. A person who owns or operates related operations subject to this regulation shall reduce VOC emissions by taking all reasonable precautions as specified in §C(2) of this regulation for SRDS operations.</text>
  </paragraph>
  <paragraph num="G.">
    <text>Additional Requirements for VOC Storage Tanks.</text>
  </paragraph>
  <paragraph num="H.">
    <text>Reporting and Record-Keeping Requirements. Reporting and record-keeping requirements for affected sources are established in the source's permit to operate.</text>
  </paragraph>
</regulation>