<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".22" citation="COMAR 26.11.19.22" title_num="26" subtitle_num="11" chapter_num="19" heading="Control of Volatile Organic Compounds from Vinegar Generators.">
  <paragraph num="A.">
    <text>Applicability. This regulation applies to a person who owns or operates a vinegar generator at a premises that has total actual VOC emissions of 20 pounds or more per day from all vinegar generators at the premises.</text>
  </paragraph>
  <paragraph num="B.">
    <text>Definitions. In this regulation, the following terms have the meanings indicated:</text>
    <paragraph num="(1)">
      <text>“Scrubber-absorber system” means equipment used to strip VOC from the exhaust gases of a vinegar generator by means of direct contact between the effluent gases and the scrubbing medium.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Vinegar Generator.</text>
      <paragraph num="(a)">
        <text>“Vinegar generator” means a fermenting reactor in which a solution of ethanol, wood chips, and nutrients are fermented aerobically under controlled conditions to produce vinegar.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>“Vinegar generator” includes an acetator.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>General Requirements. A person subject to this regulation may not operate a vinegar generator unless the unit is equipped with a scrubber-absorber system or other emission reduction system that has an overall VOC control efficiency of 85 percent or greater.</text>
  </paragraph>
  <paragraph num="D.">
    <text>Testing Requirements. A person who owns or operates a vinegar generator subject to this regulation shall:</text>
    <paragraph num="(1)">
      <text>Demonstrate compliance by performing an initial stack test by not later than September 15, 1997;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Perform additional compliance demonstration stack tests at a frequency of not less than once each 5 years beginning 5 years from the date of the initial compliance test, or at the Department's request; and</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Submit stack test reports to the Department within 60 days after completing each test.</text>
    </paragraph>
  </paragraph>
  <paragraph num="E.">
    <text>Monitoring and Records.</text>
    <paragraph num="(1)">
      <text>A person who owns or operates a vinegar generator subject to this regulation shall:</text>
      <paragraph num="(a)">
        <text>Install and operate a water flow meter on each scrubber-absorber system; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Continuously monitor the water flow.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>The water flow rate to the scrubber-absorber system is as prescribed in the source's permit to operate issued by the Department.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Water flow data shall be recorded and maintained for at least 3 years and made available to the Department on request.</text>
    </paragraph>
  </paragraph>
</regulation>