<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".29" citation="COMAR 26.11.19.29" title_num="26" subtitle_num="11" chapter_num="19" heading="Control of Volatile Organic Compounds From Distilled Spirits Facilities.">
  <paragraph num="A.">
    <text>Applicability. This regulation applies to a person who owns or operates a distilled spirits facility that has a total potential to emit VOCs of 25 tons or more per year.</text>
  </paragraph>
  <paragraph num="B.">
    <text>Definitions.</text>
    <paragraph num="(1)">
      <text>In this regulation, the following terms have the meaning indicated.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Terms Defined.</text>
      <paragraph num="(a)">
        <text>“Aging warehouse” means a building in which distilled spirits are aged in barrels before being bottled and packaged for distribution.</text>
      </paragraph>
      <paragraph num="(b)">
        <text>“Automated filling system” means an automated bottle filling system that minimizes fugitive VOC emissions by rapidly filling individual containers with the assistance of gravity and creating a vacuum or pressure during the bottling operation.</text>
      </paragraph>
      <paragraph num="(c)">
        <text>“Bottling operation” means an automated process by which empty bottles are filled with distilled spirits and sealed.</text>
      </paragraph>
      <paragraph num="(d)">
        <text>Distilled Spirits.</text>
        <paragraph num="(i)">
          <text>“Distilled spirits” means an alcoholic beverage such as rum, gin, vodka, bourbon, or whiskey.</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>“Distilled spirits” does not include beer or ale.</text>
        </paragraph>
      </paragraph>
      <paragraph num="(e)">
        <text>“Distilled spirits facility” means a process where unaged distilled spirits are received in bulk, adjusted to a designated proof, pumped into barrels, stored in an aging warehouse, bottled, and packaged.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>General Requirements.</text>
    <paragraph num="(1)">
      <text>A person who owns or operates a distilled spirits facility subject to this regulation shall:</text>
      <paragraph num="(a)">
        <text>Empty barrels using a pump-operated, bayonet-type suction device, or comparably effective device that minimizes VOC evaporative losses when emptying barrels;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Drain distilled spirits from filter plates that are located between the barrel unloading and storage tanks to either a recycling tank or to an enclosed collection system; and</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Use a gravity and vacuum or pressure filling system or comparably effective system to minimize fugitive emissions from the bottling operations.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>During the warmer weather, used barrels that are stored in the outdoors awaiting disposal shall be periodically (at least weekly) wetted down to reduce potential leakage and fugitive emissions.</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>Control of Other Fugitive Emission Sources.</text>
    <paragraph num="(1)">
      <text>A person who owns or operates a distilled spirits facility subject to this regulation shall submit to the Department for approval a good operating practices manual to minimize fugitive VOC emissions from the aging warehouse and other operations that are not subject to §D of this regulation.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>The good operating practices manual shall be submitted to the Department not later than April 30, 2001, and shall be implemented not later than 60 days after approval by the Department.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Following implementation of the approved good operating practices, a report shall be submitted to the Department which includes the following information:</text>
      <paragraph num="(a)">
        <text>An identification of the sources of fugitive emissions at which good operating practices will be implemented;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>A description of a method used to estimate emissions and estimated annual emissions for each source of fugitive emissions identified; and</text>
      </paragraph>
      <paragraph num="(c)">
        <text>A description of the method used to estimate the emission reduction resulting from implementing good operating practices and an estimate of the annual reductions achieved.</text>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>The report required in §D(3) of this regulation shall include emissions and emission reduction estimates for calendar year 2001 and shall be submitted to the Department by April 1, 2002.</text>
    </paragraph>
  </paragraph>
</regulation>