<chapter num="25" heading="Control of Glass Melting Furnaces" title_num="26" subtitle_num="11">
  <regulation prefix="Regulation" num=".01" heading="Definitions.">
    <paragraph num="A.">
      <text>“All-electric melter” means a glass melting furnace in which all the heat required for melting is provided by electric current from electrodes submerged in the molten glass, although some fossil fuel may be charged to the furnace as raw material.</text>
    </paragraph>
    <paragraph num="B.">
      <text>“Glass melting furnace” means a unit comprising a refractory vessel in which raw materials are charged, melted at high temperature, refined, and conditioned to produce molten glass. The unit includes raw material charger systems, heat exchangers, melter cooling systems, exhaust system, fuel supply and electrical boosting equipment, integral control systems, and instrumentation and appendages for conditioning and distributing molten glass to forming apparatuses.</text>
    </paragraph>
    <paragraph num="C.">
      <text>“Opal recipe” means raw material formulation of the following approximate proportions:</text>
      <paragraph num="(1)">
        <text>72 percent silica;</text>
      </paragraph>
      <paragraph num="(2)">
        <text>15 percent soda;</text>
      </paragraph>
      <paragraph num="(3)">
        <text>10 percent lime and magnesia;</text>
      </paragraph>
      <paragraph num="(4)">
        <text>2 percent alumina; and</text>
      </paragraph>
      <paragraph num="(5)">
        <text>1 percent miscellaneous materials.</text>
      </paragraph>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".02" heading="Applicability and Exemptions.">
    <paragraph num="A.">
      <text>The requirements of this chapter do not apply to frit manufacturing furnaces, flat glass furnaces, and all-electric melters.</text>
    </paragraph>
    <paragraph num="B.">
      <text>Any installation or source which is subject to the provisions of this chapter is also subject to the provisions of any other chapter. However, when this chapter establishes an emission standard for a specific installation which differs from a general emission standard in COMAR 26.11.06.01—.09, this chapter takes precedence.</text>
    </paragraph>
    <paragraph num="C.">
      <text>This regulation applies only in Areas III and IV.</text>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".03" heading="Visible Emissions from Glass Melting Furnaces.">
    <paragraph num="A.">
      <text>General Requirements.</text>
      <paragraph num="(1)">
        <text>A person may not cause or permit the discharge of emissions of greater than 20 percent opacity from a glass melting furnace.</text>
      </paragraph>
      <paragraph num="(2)">
        <text>A person may not cause or permit the discharge of fugitive emissions of greater than 20 percent opacity from a building containing forming and post-forming equipment.</text>
      </paragraph>
    </paragraph>
    <paragraph num="B.">
      <text>Exceptions.</text>
      <paragraph num="(1)">
        <text>The provisions of §A(1) and (2) of this regulation do not apply to emissions that occur during process modifications or adjustments and that are not greater than 40 percent opacity for a period of not more than 6 consecutive minutes in any 60 minutes.</text>
      </paragraph>
      <paragraph num="(2)">
        <text>A person who owns or operates a gas-fired installation subject to this chapter other than an opal recipe glass melting furnace is not eligible for a visible emission exception under COMAR 26.11.06.02B for that installation.</text>
      </paragraph>
    </paragraph>
  </regulation>
  <regulation prefix="Regulation" num=".04" heading="Particulate Matter Emissions from Glass Melting Furnaces.">
    <paragraph num="A.">
      <text>General Requirements. A person may not cause or permit the discharge of particulate matter into the outdoor atmosphere from a glass melting furnace in excess of the amount determined using the following equation:</text>
      <paragraph num="(1)">
        <text>E = 5 + 0.48 (P)</text>
      </paragraph>
      <paragraph num="(2)">
        <text>E = 2.27 + 0.24 (P)</text>
      </paragraph>
      <aftertext>where:</aftertext>
    </paragraph>
    <paragraph num="B.">
      <text>Exception. A person who owns or operates an opal recipe glass melting furnace with an interruptible gas service, as defined in COMAR 26.11.09.01C, may exceed the requirements in Regulation .03A of this chapter and §A of this regulation when gas service is interrupted by the utility if maximum available electric boosting is used in conjunction with an alternative fuel.</text>
    </paragraph>
  </regulation>
  <annotations>
    <annotation type="Authority">Environment Article, §§1-101, 1-404, 2-101—2-103, 2-301—2-303, 10-102, and 10-103, Annotated Code of Maryland</annotation>
    <annotation type="History" subtype="Administrative History">Effective date: September 24, 1984 (11:17 Md. R. 1492)</annotation>
    <annotation type="History" subtype="Administrative History">Regulation .03B amended effective July 2, 1985 (12:11 Md. R. 1050)</annotation>
    <annotation type="History" subtype="Administrative History">Chapter recodified from COMAR 10.18.16 to COMAR 26.11.16</annotation>
    <annotation type="History" subtype="Administrative History">Chapter recodified from COMAR 26.11.16 to COMAR 26.11.25 effective October 5, 1998 (25:20 Md. R. 1533)</annotation>
  </annotations>