<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".04" citation="COMAR 26.11.39.04" title_num="26" subtitle_num="11" chapter_num="39" heading="General Requirements and Standards.">
  <paragraph num="A.">
    <text>VOC Content Limits.</text>
    <paragraph num="(1)">
      <text>Except as provided in this regulation, a person may not manufacture, blend, repackage for sale, supply, sell, offer for sale, or apply within the State an architectural coating with a VOC content in excess of the corresponding limit specified in Regulation .05 of this chapter.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Limits are expressed as VOC content, thinned to the manufacturer’s maximum thinning recommendation, excluding any colorant added to tint bases.</text>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>Most Restrictive VOC Limit. If anywhere on the container of an architectural coating, label or sticker affixed to the container, or in any sales, advertising, or technical literature supplied by a manufacturer or anyone acting on behalf of a manufacturer, any representation is made that indicates that the coating meets the definition of or is recommended for use for more than one of the coating categories listed in Regulation .05 of this chapter, then the most restrictive VOC content limit applies.</text>
  </paragraph>
  <paragraph num="C.">
    <text>The provisions of §B of this regulation do not apply to the following coating categories:</text>
    <paragraph num="(1)">
      <text>Aluminum roof coatings;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Bituminous roof primers;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>High-temperature coatings;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Industrial maintenance coatings;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>Low-solids coatings;</text>
    </paragraph>
    <paragraph num="(6)">
      <text>Metallic pigmented coatings;</text>
    </paragraph>
    <paragraph num="(7)">
      <text>Pretreatment wash primers;</text>
    </paragraph>
    <paragraph num="(8)">
      <text>Shellacs;</text>
    </paragraph>
    <paragraph num="(9)">
      <text>Specialty primers, sealers, and undercoaters;</text>
    </paragraph>
    <paragraph num="(10)">
      <text>Wood coatings;</text>
    </paragraph>
    <paragraph num="(11)">
      <text>Wood preservatives;</text>
    </paragraph>
    <paragraph num="(12)">
      <text>Zinc-rich primers</text>
    </paragraph>
    <paragraph num="(13)">
      <text>Calcimine recoaters;</text>
    </paragraph>
    <paragraph num="(14)">
      <text>Impacted immersion coatings;</text>
    </paragraph>
    <paragraph num="(15)">
      <text>Nuclear coatings;</text>
    </paragraph>
    <paragraph num="(16)">
      <text>Thermoplastic rubber coatings and mastic; and</text>
    </paragraph>
    <paragraph num="(17)">
      <text>Concrete surface retarders.</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>Sell-Through of Coatings.</text>
    <paragraph num="(1)">
      <text>A coating manufactured before the effective date of January 1, 2017, that complied with the standards in effect at the time the coating was manufactured may be sold, supplied, or offered for sale until January 1, 2020.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>A coating that complies with the standards in effect in this State at the time of manufacture may be applied at any time.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>The provisions of this section do not apply to a coating that does not display a date or date code representing the date of manufacture.</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Notwithstanding §D(2) of this regulation, a person may not apply any rust preventative coating manufactured before January 1, 2017 for industrial use, unless such a rust preventative coating complies with the industrial maintenance coating limit specified in Regulation .05 of this chapter.</text>
    </paragraph>
  </paragraph>
  <paragraph num="E.">
    <text>Painting Practices.</text>
    <paragraph num="(1)">
      <text>All architectural coating containers used to apply the contents therein to a surface by pouring, siphoning, brushing, rolling, padding, ragging, or other means, shall be closed when not in use.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Architectural coatings containers include, but are not limited to drums, buckets, cans, pails, trays, or other application containers.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Containers of any VOC-containing materials used for thinning and cleanup shall also be closed when not in use.</text>
    </paragraph>
  </paragraph>
  <paragraph num="F.">
    <text>Thinning. A person may not apply any architectural coating if the coating is thinned to exceed the applicable VOC limit specified in Table 1 of Regulation .05 of this chapter.</text>
  </paragraph>
  <paragraph num="G.">
    <text>Coatings Not Listed in Regulation .05 of this Chapter. A coating that does not meet the definitions for the specialty coatings categories listed in Regulation .05 of this chapter is subject to the VOC content limit for either a flat, non-flat, or non-flat high gloss coating based on its gloss as determined in Regulation .02B(2) of this chapter.</text>
  </paragraph>
  <paragraph num="H.">
    <text>New Coatings Categories. Beginning May 1, 2016, the following new coatings categories shall be considered in compliance if the coating meets the applicable VOC limit specified in Table 1 of Regulation .05 of this chapter and the other provisions of this chapter:</text>
    <paragraph num="(1)">
      <text>Aluminum roof coatings;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Basement specialty coatings;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Concrete/masonry sealers;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Conjugated oil varnish;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>Driveway sealers;</text>
    </paragraph>
    <paragraph num="(6)">
      <text>Reactive penetrating sealer;</text>
    </paragraph>
    <paragraph num="(7)">
      <text>) Reactive penetrating carbonate stone sealers;</text>
    </paragraph>
    <paragraph num="(8)">
      <text>Stone consolidant;</text>
    </paragraph>
    <paragraph num="(9)">
      <text>Tub and tile refinishing coating;</text>
    </paragraph>
    <paragraph num="(10)">
      <text>Waterproofing membranes;</text>
    </paragraph>
    <paragraph num="(11)">
      <text>Wood coatings; and</text>
    </paragraph>
    <paragraph num="(12)">
      <text>Zinc-rich primers.</text>
    </paragraph>
  </paragraph>
</regulation>