<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".18-1" citation="COMAR 26.13.05.18-1" title_num="26" subtitle_num="13" chapter_num="05" heading="Containment Buildings — Design Standards.">
  <paragraph num="A.">
    <text>The owner and operator of a containment building being used to manage hazardous waste shall assure that the containment building meets the following design standards:</text>
    <paragraph num="(1)">
      <text>The containment building is a structure completely enclosed with a floor, walls, and a roof to:</text>
      <paragraph num="(a)">
        <text>Prevent exposure of the interior to the elements, that is, precipitation, wind, and surface water run-on; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Assure containment of managed wastes;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>Except as provided in §A(3) of this regulation, the floor and containment walls of the unit, including a secondary containment system required under §B of this regulation have been designed and constructed of manmade materials in accordance with the following requirements:</text>
      <paragraph num="(a)">
        <text>The floor and containment walls are of sufficient strength and thickness to:</text>
        <paragraph num="(i)">
          <text>Support themselves, the waste contents, and any personnel and heavy equipment that operates within the unit; and</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Prevent failure due to pressure gradients, settlement, compression, uplift, physical contact with the hazardous wastes to which the materials are exposed, climatic conditions, and the stresses of daily operation, including the movement of heavy equipment within the unit and contact of heavy equipment with containment walls; and</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Have sufficient structural strength to prevent collapse or other failure; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="(b)">
        <text>All surfaces in contact with hazardous wastes or intended to be in contact with hazardous wastes are chemically compatible with those wastes;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>Lightweight doors and windows are not subject to the design requirements concerning structural strength in §A(1)—(2) of this regulation if:</text>
      <paragraph num="(a)">
        <text>The incorporation of the lightweight doors and windows into the design of the containment building is appropriate to the nature of the waste management operation to take place in the unit;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The lightweight doors and windows provide an effective barrier against fugitive dust emissions in accordance with the requirements of Regulation .18-2B(5)— (7) of this chapter; and</text>
      </paragraph>
      <paragraph num="(c)">
        <text>The containment building design and the way in which it is operated assures that wastes will not come in contact with these openings; and</text>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>The containment building has a primary barrier that is:</text>
      <paragraph num="(a)">
        <text>Designed to withstand the movement of personnel, waste, and handling equipment in the unit during the operating life of the unit; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Appropriate for the physical and chemical characteristics of the waste to be managed.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>Except as provided in §E of this regulation, the owner and operator of a containment building used to manage hazardous waste that contains free liquids or that is treated with free liquids shall assure that the containment building meets the following design standards:</text>
    <paragraph num="(1)">
      <text>The containment building includes a primary barrier designed and constructed of materials to prevent the migration of hazardous constituents into the barrier, such as, for example, a geomembrane covered by a concrete wear surface;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>The containment building includes a liquid collection and removal system to minimize the accumulation of liquid on the primary barrier of the containment building;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>The primary barrier required by §B(1) of this regulation is sloped to drain liquids to the associated collection system;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>The system required by §B(2) of this regulation provides for the collection and removal of liquids and wastes at the earliest practicable time to minimize hydraulic head on the containment system;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>The containment building includes:</text>
      <paragraph num="(a)">
        <text>A secondary containment system with a secondary barrier designed and constructed to prevent migration of hazardous constituents into the barrier; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>A leak detection system that is capable of detecting failure of the primary barrier and collecting accumulated hazardous wastes and liquids at the earliest practicable time;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(6)">
      <text>The leak detection component of the secondary containment system required by §B(5)(b) of this regulation performs at least as well as a system that is, at a minimum:</text>
      <paragraph num="(a)">
        <text>Constructed with a bottom slope of 1 percent or more; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Constructed of:</text>
        <paragraph num="(i)">
          <text>A granular drainage material with a hydraulic conductivity of 1 × 10-2 centimeters/second or more and a thickness of 12 inches (30.5 centimeters) or more; or</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Synthetic or geonet drainage materials with a transmissivity of 3 × 10-5 square meters/second or more;</text>
        </paragraph>
      </paragraph>
    </paragraph>
    <paragraph num="(7)">
      <text>If hazardous waste is to be treated in the containment building, each area in which hazardous waste treatment is conducted is designed to prevent the release of liquids, wet materials, or liquid aerosols to other portions of the building; and</text>
    </paragraph>
    <paragraph num="(8)">
      <text>The secondary containment system is constructed of materials that are:</text>
      <paragraph num="(a)">
        <text>Chemically resistant to the waste and liquids managed in the containment building; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Of sufficient strength and thickness to prevent collapse under the pressure exerted by overlaying materials and by any equipment used in the containment building.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>Determination of the Presence of Free Liquids. For the purposes of §B of this regulation, a person shall determine whether free liquids are present by:</text>
    <paragraph num="(1)">
      <text>The paint filter liquids test, Method 9095A of Test Methods for Evaluating Solid Waste, Physical/Chemical Methods EPA SW-846, which is incorporated by reference in COMAR 26.13.01.05A(4);</text>
    </paragraph>
    <paragraph num="(2)">
      <text>A visual examination; or</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Another appropriate means acceptable to the Secretary.</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>For a containment building that contains areas both with and without secondary containment, the owner or operator shall assure that each area is designed in accordance with the requirements of this regulation.</text>
  </paragraph>
  <paragraph num="E.">
    <text>Waiver of Secondary Containment Requirements. Notwithstanding any other provisions of this regulation and Regulations .18 and .18-2 of this chapter, the Secretary may waive the requirements for secondary containment for a permitted containment building if the owner or operator demonstrates that:</text>
    <paragraph num="(1)">
      <text>The only free liquids in the unit are limited amounts of liquids used to provide dust suppression required to meet occupational health and safety requirements; and</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Containment of managed wastes and liquids can be assured without a secondary containment system.</text>
    </paragraph>
  </paragraph>
  <paragraph num="F.">
    <text>Containment Building as an External Liner for a Tank. A person may use a containment building to serve as an external liner system for a tank for the purposes of providing secondary containment for the tank under Regulation .10-4D of this chapter if the containment building meets the requirements of Regulation .10-4B—C of this chapter.</text>
  </paragraph>
</regulation>