<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".02-8" citation="COMAR 26.13.07.02-8" title_num="26" subtitle_num="13" chapter_num="07" heading="Specific Information Requirements for Landfills.">
  <paragraph num="A.">
    <text>In addition to complying with the requirements of Regulation .02 of this chapter, a person seeking a CHS facility permit for a hazardous waste management facility that uses, or is proposed to use, a landfill to manage hazardous waste shall provide the Secretary with the specific information required by §B of this regulation.</text>
  </paragraph>
  <paragraph num="B.">
    <text>For facilities that dispose of hazardous waste in landfills, except as otherwise provided in COMAR 26.13.05.01, the permit applicant shall provide the following information:</text>
    <paragraph num="(1)">
      <text>A list of the hazardous wastes placed or to be placed in each landfill or landfill cell;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>A detailed plan and an engineering report that:</text>
      <paragraph num="(a)">
        <text>Describe how the landfill is or will be designed, constructed, operated, and maintained to comply with the requirements of COMAR 26.13.05.02-2 and 14B; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Provide information on the following items as specified in COMAR 26.13.05.14B:</text>
        <paragraph num="(i)">
          <text>The liner system and leachate collection and removal system, except for an existing portion of landfill;</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>If an exemption from the requirements for a liner and a leachate collection and removal system is sought as provided by COMAR 26.13.05.14B(2) or (4), detailed plans and engineering hydrogeologic reports as appropriate, describing alternate design and operating practices that will, in conjunction with location aspects, prevent the migration of any hazardous constituents into the ground water or surface water at any future time;</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Control of run-on;</text>
        </paragraph>
        <paragraph num="(iv)">
          <text>Control of run-off;</text>
        </paragraph>
        <paragraph num="(v)">
          <text>Management of collection and holding facilities associated with run-on and run-off control systems; and</text>
        </paragraph>
        <paragraph num="(vi)">
          <text>Control of wind dispersal of particulate matter, when applicable;</text>
        </paragraph>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>A description of how each landfill, including the double liner system, leachate collection and removal system, leak detection system, cover system, and appurtenances for control of run-on and run-off will be inspected in order to meet the requirements of COMAR 26.13.05.14C(1)—(4) as part of the inspection plan submitted under Regulation .02D(19) of this chapter;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>Detailed plans and an engineering report describing the final cover which will be applied to each landfill or landfill cell at closure in accordance with COMAR 26.13.05.14J(1), and a description of how each landfill will be maintained and monitored after closure in accordance with COMAR 26.13.05.14J(2) as part of the closure and post-closure plans submitted under Regulation .02D(29) of this chapter;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>If food-chain crops are to be grown, and cadmium is present in the land treated waste, a description of how the requirements of COMAR 26.13.05.13G(5) will be complied with;</text>
    </paragraph>
    <paragraph num="(6)">
      <text>A description of the vegetative cover to be applied to closed portions of the facility, and a plan for maintaining the cover during the post-closure care period, as required under COMAR 26.13.05.13K(1)(h) and (3)(b). This information should be included in the closure plan and, when applicable, the post-closure care plan submitted under Regulation .02D(29) of this chapter;</text>
    </paragraph>
    <paragraph num="(7)">
      <text>If ignitable or reactive wastes will be placed in or on the treatment zone, an explanation of how the requirements of COMAR 26.13.05.13L will be complied with;</text>
    </paragraph>
    <paragraph num="(8)">
      <text>A waste management plan for EPA Hazardous Waste Nos. F020, F021, F022, F023, F026, and F027 that:</text>
      <paragraph num="(a)">
        <text>Describes how a landfill is or will be designed, constructed, operated, and maintained to meet the requirements of COMAR 26.13.05.14P; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Addresses the:</text>
        <paragraph num="(i)">
          <text>Volume, physical characteristics, and chemical characteristics of the wastes, including their potential to migrate through soil or to volatilize or escape into the atmosphere;</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Attenuative properties of underlying and surrounding soils or other materials;</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Mobilizing properties of other materials co-disposed with these wastes; and</text>
        </paragraph>
        <paragraph num="(iv)">
          <text>Effectiveness of additional treatment, design, or monitoring techniques;</text>
        </paragraph>
      </paragraph>
    </paragraph>
    <paragraph num="(9)">
      <text>If the leak detection system is located in a saturated zone, detailed plans and an engineering report explaining the leak detection system's design and operation, and the location of the saturated zone in relation to the leak detection system;</text>
    </paragraph>
    <paragraph num="(10)">
      <text>The construction quality assurance plan required by COMAR 26.13.05.02-2;</text>
    </paragraph>
    <paragraph num="(11)">
      <text>If required under COMAR 26.13.05.14E, a proposed action leakage rate with rationale and supporting information; and</text>
    </paragraph>
    <paragraph num="(12)">
      <text>If required under COMAR 26.13.05.14F, a response action plan.</text>
    </paragraph>
  </paragraph>
</regulation>