<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".16-1" citation="COMAR 26.13.10.16-1" title_num="26" subtitle_num="13" chapter_num="10" heading="Small Quantity Handlers of Universal Waste Aerosol Cans — Specific Management Standards.">
  <paragraph num="A.">
    <text>A small quantity handler of universal waste shall manage universal waste aerosol cans in a way that prevents any releases of universal waste or a component of universal waste to the environment.</text>
  </paragraph>
  <paragraph num="B.">
    <text>A small quantity handler of universal waste shall:</text>
    <paragraph num="(1)">
      <text>Accumulate universal waste aerosol cans in a container that is:</text>
      <paragraph num="(a)">
        <text>Structurally sound;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Compatible with the contents of the aerosol cans;</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Lacking evidence of:</text>
        <paragraph num="(i)">
          <text>Leakage;</text>
        </paragraph>
        <paragraph num="(ii)">
          <text>Spillage; or</text>
        </paragraph>
        <paragraph num="(iii)">
          <text>Damage that could cause leakage under reasonably foreseeable conditions; and</text>
        </paragraph>
      </paragraph>
      <paragraph num="(d)">
        <text>Protected from sources of heat;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(2)">
      <text>Manage a universal waste aerosol can that show evidence of leakage by:</text>
      <paragraph num="(a)">
        <text>Packaging the aerosol can in a separate closed container;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Overpacking the aerosol can in a container with absorbents; or</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Immediately puncturing and draining the aerosol can in accordance with the requirements of §D of this regulation.</text>
      </paragraph>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>A small quantity handler of universal waste may conduct the following activities if each individual aerosol can is not breached and remains intact:</text>
    <paragraph num="(1)">
      <text>Sorting aerosol cans by type;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Commingling intact aerosol cans in one container; and</text>
    </paragraph>
    <paragraph num="(3)">
      <text>Removing actuators to reduce the risk that an accidental release will occur.</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>A small quantity handler of universal waste aerosol cans who punctures and drains a universal waste aerosol can shall:</text>
    <paragraph num="(1)">
      <text>Recycle the empty punctured aerosol can;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Conduct puncturing and draining activities using a device specifically designed to:</text>
      <paragraph num="(a)">
        <text>Safely puncture aerosol cans; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Effectively contain the residual contents from the punctured can and any related emissions;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(3)">
      <text>Establish and follow a written procedure that specifies how to safely puncture and drain the universal waste aerosol can, including details about the following topics:</text>
      <paragraph num="(a)">
        <text>Proper assembly, operation, and maintenance of the device used for the activity;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Segregation of incompatible wastes generated; and</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Proper waste management practices to prevent fires and releases;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(4)">
      <text>Maintain, on site, a copy of the manufacturer’s operating instructions and specifications for the device that is being used for puncturing and draining;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>Ensure that persons performing puncturing and draining activities are trained in the proper procedures for conducting the activities.</text>
    </paragraph>
    <paragraph num="(6)">
      <text>Ensure that puncturing of the can is done in a manner that:</text>
      <paragraph num="(a)">
        <text>Is designed to prevent fires and prevent the release of any component of universal waste to the environment; and</text>
      </paragraph>
      <paragraph num="(b)">
        <text>In addition to other appropriate measures to satisfy the requirements of §D(6(a) of this regulation, includes locating the puncturing equipment on a solid, flat surface in a well-ventilated area;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(7)">
      <text>Immediately transfer the contents from the waste aerosol can or puncturing device, if applicable, to a container or tank that meets the applicable requirements in:</text>
      <paragraph num="(a)">
        <text>COMAR 26.13.02.05;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>COMAR 26.13.03.03-3; or</text>
      </paragraph>
      <paragraph num="(c)">
        <text>COMAR 26.13.03.03-4 —.03-11, .05E, .05-1, and .05-2;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(8)">
      <text>Conduct a hazardous waste determination in accordance with the requirements of COMAR 26.13.03.02—.02-2 on:</text>
      <paragraph num="(a)">
        <text>The contents emptied from the aerosol can;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>The punctured, drained aerosol can if the aerosol can does not meet the criteria of COMAR 26.13.02.07B to be considered “empty”; and</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Any other solid waste generated in connection with the puncturing and draining of the aerosol can;</text>
      </paragraph>
    </paragraph>
    <paragraph num="(9)">
      <text>Manage any hazardous waste generated as a result of puncturing and draining the aerosol can in accordance with all applicable requirements of COMAR 26.13.01—.10, with the universal waste handler being considered the generator of the hazardous waste and subject to the requirements of COMAR 26.13.03;</text>
    </paragraph>
    <paragraph num="(10)">
      <text>Manage nonhazardous waste generated as a result of puncturing and draining the aerosol can in accordance with applicable State, federal, and local solid waste regulations; and</text>
    </paragraph>
    <paragraph num="(11)">
      <text>Satisfy the following requirements concerning emergency preparedness and response:</text>
      <paragraph num="(a)">
        <text>Have in place a written procedure on how to respond in the event of a spill or leak to minimize risks to human health and the environment;</text>
      </paragraph>
      <paragraph num="(b)">
        <text>Have a spill cleanup kit readily available; and</text>
      </paragraph>
      <paragraph num="(c)">
        <text>Promptly clean up any spill or leak of the contents of an aerosol can.</text>
      </paragraph>
    </paragraph>
  </paragraph>
</regulation>