<?xml version='1.0' encoding='utf-8'?>
<regulation prefix="Regulation" num=".07" citation="COMAR 26.16.07.07" title_num="26" subtitle_num="16" chapter_num="07" heading="Standard Sampling Method.">
  <paragraph num="A.">
    <text>Schools shall collect samples in accordance with the following procedures:</text>
    <paragraph num="(1)">
      <text>Collect 250 mL first-draw samples in prelabeled sampling bottles.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Collect samples from the cold water tap.</text>
    </paragraph>
    <paragraph num="(3)">
      <text>If the outlet has an aerator, leave the aerator in place during sampling.</text>
    </paragraph>
    <paragraph num="(4)">
      <text>If the outlet has a filter, sample without the filter.</text>
    </paragraph>
    <paragraph num="(5)">
      <text>Determine if one chiller serves more than one fountain; if it does, collect first-draw samples from each fountain.</text>
    </paragraph>
    <paragraph num="(6)">
      <text>Follow all laboratory or Department instructions for collecting, handling, and submitting water samples.</text>
    </paragraph>
    <paragraph num="(7)">
      <text>Samples must be acidified within 14 days of collection unless sample bottles are pre-acidified by the laboratory.</text>
    </paragraph>
  </paragraph>
  <paragraph num="B.">
    <text>Schools shall ensure that samples have appropriate water age in the following ways:</text>
    <paragraph num="(1)">
      <text>Collect samples of water that have been sitting in pipes for at least 8 hours but not more than 18 hours.</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Samples may be collected from outlets in which the water exceeds the 18 hour stagnation period if these outlets are used infrequently, and this stagnation period represents normal use patterns.</text>
    </paragraph>
  </paragraph>
  <paragraph num="C.">
    <text>Schools shall ensure that samples are analyzed:</text>
    <paragraph num="(1)">
      <text>By a laboratory certified by the Department for lead analysis;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>Within 6 months of preservation; and</text>
    </paragraph>
    <paragraph num="(3)">
      <text>In accordance with EPA method 200.8, EPA method 200.9, or current method approved in 40 CFR §141.23 or COMAR 26.04.01.01-1.</text>
    </paragraph>
  </paragraph>
  <paragraph num="D.">
    <text>Schools shall complete the following records for each sample collected:</text>
    <paragraph num="(1)">
      <text>Record the type of sample;</text>
    </paragraph>
    <paragraph num="(2)">
      <text>The building address;</text>
    </paragraph>
    <paragraph num="(3)">
      <text>The location within the building;</text>
    </paragraph>
    <paragraph num="(4)">
      <text>The specific tap tested;</text>
    </paragraph>
    <paragraph num="(5)">
      <text>The date and time the water was last used;</text>
    </paragraph>
    <paragraph num="(6)">
      <text>The date and time the sample was collected;</text>
    </paragraph>
    <paragraph num="(7)">
      <text>The name and contact information of the sample collector for each sample collected, as indicated in guidance developed by the Department; and</text>
    </paragraph>
    <paragraph num="(8)">
      <text>The completed chain of custody form.</text>
    </paragraph>
  </paragraph>
</regulation>